• Title/Summary/Keyword: Esthetics, dental

Search Result 315, Processing Time 0.022 seconds

A Survey on Preliminary Dental Hygienists' Senses of Employment (예비치과위생사의 취업에 관한 의식 조사)

  • Han, Su-Jin;Lee, Sun-Mi;Lim, Mi-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.4
    • /
    • pp.583-594
    • /
    • 2007
  • The purpose of this study was to conduct a survey on the senses that preliminary dental hygienists have on employment, who applied for the National Dental Hygienist Examination, so that it could provide a basic reference required for fostering good human resources specializing in oral health with a sense of mission and responsibility as professional. To meet these goals, a self-administered questionnaire survey was conducted for participants in a refresher education meeting for preliminary dental hygienists across three major regions(Seoul, Daejeon and Busan), which was held by the Korean Dental Hygienists Association(KDHA) on Jan. 15, 2006. Total 289 sheets of questionnaire were collected, and 262 sheets except invalid or incomplete ones were used for examination and analysis. As a result, this study came to the following conclusions: First, it was found that 40.4% respondents wanted to be employed in dental clinic or hospital. Most respondents(90.1%) answered that faithfulness is most valued as prerequisite qualification for employment in hospital, and highest percentage of respondents(39.3%) wanted to earn 16 to 17 million Korean won annually. For internship opportunities, 61.9% respondents replied that they could willingly accept the internship, provided that basic pay and switchover to regular employee are all assured. Second, as the results of survey on employment circumstances around respondents, it was found that most respondents(58.3%) were employed in dental clinic or hospital, and highest percentage of respondents(35.0%) earned 15 to 16 million Korean won. Third, it was found that interpersonal relationships among employees had most significant effects(4.81) on selection of employment, which was followed by in-house welfare benefits 1(monthly/annual vacation, resting room, etc; 4.56). For possible influential factors on the selection of employment depending on whether employed or not, it was found that there were Significant differences in pay, welfare benefit 2(seminar, orientation, refresher training opportunities, etc), post-wedding continued employment and merit system between employees and non-employees(pE0.05). Fourth, the survey on respondents' occupational senses of dental hygienist showed that major tasks of dental hygienists were represented by oral disease prevention(92.6%), case management(71.5%), oral health education(66.3%), hospital/clinic management and dental management support(10.4%) and public oral health activities(6.7%) respectively. For job satisfaction, it was found that almost half respondents(48.9%) showed satisfaction at their job and 32.6% felt satisfied at and proud of their job. That is, majority of respondents(81.5%) felt satisfied at their job as dental hygienist. For follow-up requirements to qualify for dental hygienists, it was found that 73.3% felt it necessary to give more investments to self-development, 62.2% respondents considered protection of membership's rights as one of future assignments that KDHA should be more committed to. For future social awareness about dental hygienists as occupation, 69.2% respondents expected that they would be better developed and treated as professional. And desired training courses as a part of qualification for professional dental hygienists were represented by case management(services, manners, etc; 33.3%), implant(28.9%), esthetics(correction, prosthesis, whitening; 18.9%) and so on. For an item on working years, it was noted that 75.9% respondents would keep working as dental hygienists as long as they could.

  • PDF

Spontaneous teeth migration after periodontal treatment in the patients with drug-induced gingival enlargement (약물성 치은비대로 인한 병적인 치아 이동이 있는 환자에서 치주치료 이후 자발적 치아 이동을 보인 증례)

  • Choi, Youn-Kyung;Jung, Kyoung-Hwa;Kim, So-Yeun;Jeon, Hye-Mi;Choi, Jeomil;Lee, Ju-Youn;Joo, Ji-Young;Kwon, Eun-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.1
    • /
    • pp.34-41
    • /
    • 2017
  • Anticonvulsants, calcium channel blockers and immunosuppressants are representative drugs related with gingival enlargement. Clinical signs and symptoms caused by drug-induced gingival enlargment frequently appear within 1 to 3 months after medication. At initial stage, it is limited to attached gingiva but may extend coronally and interfere with esthetics, mastication and speech. Interproximal spaces are common beginning area and pathologic teeth migration could be occurred by the lesion. Withdrawal or substitution of medication would be the most effective treatment of drug-induced gingival enlargement. However, periodontal treatment and further supportive periodontal therapy should be provided where change in medication is impossible. The present study reports the cases which show the resolution of inflammation with spontaneous teeth migration without change in medication. In all cases discussed in this report could be efficiently managed with proper periodontal treatment and further supportive periodontal therapy.

Digital intraoral impression for immediate provisional restoration of maxillary single implant: A case report (구강 내 디지털 인상채득을 통한 상악 전치부 임플란트 즉시 임시 보철 수복 증례)

  • Chang, Yun-Jeong;Kim, Hong-Jun;Song, Mi-Kyoung;Moon, Ji-Eun;Lee, Hal-La;Park, Chan-Ik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.234-243
    • /
    • 2015
  • Developing of digital technique, it is possible to fabricate implant prostheses for edentulous area using intraoral 3-dimentional information throughout implant diagnosis and treatment process. It is being changed that from the method using CAD/CAM, producing prostheses by model scanning after conventional impression and model processing, to the method of fabricating implant provisional restorations and customized abutments by digital impression after connecting digital impression copings (scanbody) and implant fixtures without models. But, this digital method has not been actively used for implant prostheses not yet. Specially, it is short of intraoral digital impression cases for immediate provisional restorations of the maxillary anterior implants. The gingival contour impression of maxillary anterior area is very important for esthetic restorations. Accordingly, in this case report, the using a digital impression coping (scanbody) and digital impression by CEREC Omnicam (Sirona, Bensheim, Germany) or Trios (3shape, Copenhagen, Denmark) were introduced for immediate provisional restorations in 3 cases needed a single implant restoration in maxillary anterior area. The clinical results were satisfactory on the convenience and accuracy of digital impression technique and the good esthetics of final restorations.

A simple approach to preserve keratinized mucosa around implants using a pre-fabricated implant-retained stent: a report of two cases

  • Park, Jung-Chul;Yang, Ki-Bin;Choi, You-Na;Kim, Yong-Tae;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.4
    • /
    • pp.194-200
    • /
    • 2010
  • Purpose: There is no consensus regarding the relationship between the width of keratinized mucosa and the health of periimplant tissues, but clinicians prefer to provide enough keratinized mucosa around dental implants for long-term implant maintenance. An apically positioned flap during second stage implant surgery is the chosen method of widening the keratinized zone in simple procedures. However, the routine suture techniques used with this method tend to apply tension over the provisional abutments and decrease pre-existing keratinized mucosa. To overcome this shortcoming, a pre-fabricated implant-retained stent was designed to apply vertical pressure on the labial flap and stabilize it in a bucco-apical direction to create a wide keratinized mucous zone. Methods: During second stage implant surgery, an apically displaced, partial thickness flap with a lingualized incision was retracted. A pre-fabricated stent was clipped over the abutments after connecting to the provisional abutment. Vertical pressure was applied to displace the labial flap. No suture was required and the stent was removed after 10 days. Results: A clinically relevant amount of keratinized mucosa was achieved around the dental implants. Buccally displaced keratinized mucosa was firmly attached to the underlying periosteum. A slight shrinkage of the keratinized zone was noted after the healing period in one patient, but no discomfort during oral hygiene was reported. Clinically healthy gingiva with enough keratinized mucosa was achieved in both patients. Conclusions: The proposed technique is a simple and time-effective technique for preserving and providing keratinized tissue around dental implants.

Implants in conjunction with removable partial denture (임플란트를 이용한 국소의치 수복)

  • Kim, Seong-Kyun;Yoo, Soo-Yeon;Park, In-Phil;Lee, Joo-Hee
    • The Journal of the Korean dental association
    • /
    • v.49 no.2
    • /
    • pp.77-84
    • /
    • 2011
  • The benefits of implant supported overdenture are readily apparent for the fully edentulous patients and have been well documented, however, there is deficiency of the studies regarding the combination of implants with removable partial dentures for partially edentulous patients. The purpose of this article is to review the literature concerning implants with removable partial dentures and evaluate the evidence for this clinical approach. Through many clinical case reports and studies we have searched from a broad variety of journals, we present the six considerations needed to contemplate respecting implants with removable partial denture in partially edentulous patients. First, the connection between abutment tooth and removable partial denture has to be rigid and the link between implant and removable partial denture should be hinged. Second, a mesial rest acts better in the point of force distribution for distal extension removable partial denture and splinting between implants is also a favorable choice. Third, T bar has an advantage for implants which are used as abutments in distal extension removable partial denture. Forth, as we all known functional impression is better way to reproduce movement for distal extension removable partial denture. Fifth, indirect retainer and guiding plane on the proximal surfaces of terminal abutment teeth are important in preventing denture base lifting. Sixth, implants in conjunction with removable partial denture is superior in the esthetic and phonetic as well as cost-effective point of view. We also suggest that which place we should install implants for force distribution and which diameter and length of implants should be used. in this review article, we recommend to locate the implant near of the abutment tooth for esthetics or near of first molar position for good stress distribution. The diameter and length of implant also influence to stress distribution. When we compare to conservative partial denture, patients go for removable partial denture using implants due to convenience, better support and retention according to several studies. But it is true that we need to study more on this subject and collect long term follow up cases before we discuss on it. So it is enough to bring this subject into the surface of prosthetic treatment by this article.

CLINICAL STUDY OF AUGMENTATION MALARPLASTY WITH POROUS POLYETHYLENE (Porous polyethylene을 이용한 관골증대술의 임상연구)

  • Kook, Min-Suk;An, Jin-Suk;Kim, Young-Joon;Park, Hong-Ju;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.3
    • /
    • pp.283-291
    • /
    • 2008
  • The malar mound defines the contour of the lateral face between the inferior orbital rim and the mandible, and hypoplasia or asymmetry of this region is readily noticeable. A flat, hypoplastic malar eminence can make the face blunt and wearisome, which contributes to a premature aged appearance. Patients with congenital or traumatic flattening of the malar eminence can obtain esthetic improvement with implants. Indications for placement of malar implants to improve the appearance of subtle flattening or to enhance the esthetic harmony of a patient's face have been suggested in several studies. Many augmentation materials, such as silicone, proplast, polyamide, and porous polyethylene implants have been used. Many methods of localization have been described, the key to proper placement of the implants lies in a through understanding of the esthetics of the malar mound. From August 2001 to June 2007, 12 patients with malar depression who visited the Department of Oral and Maxillofacial Surgery, Chonnam National University Hospital were treated by augmentation malarplasty with Porous polyethylene. The location and amount of augmentation are determined by preoperative interview, physical examinations, facial models and radiographic findings. 12 patients were satisfied with the results of augmentation malarplasty and severe complications were not occurred.

The Effect of Veneering Techniques on the Color Parameters of Y-TZP Based All Ceramic Restoration of Varying Ceramic Core Thickness (지르코니아 코어 두께에 따른 전부도재관의 상부도재 축성방법이 보철물 색조에 미치는 영향)

  • Huh, Sung-Yoon;Son, Ho-Jung;Kim, Hae-Young;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.12 no.2
    • /
    • pp.123-129
    • /
    • 2012
  • The aim of study was to compare the color parameters and mean color difference of porcelain specimens by different veneering technique in order to examine the effect of veneering technique on esthetics of yttria-stabilized tetragonal zirconia polycrystalline(Y-TZP) all ceramic restoration. Three groups of square-shaped core ceramic specimens(14mm in diameter and 0.3, 0.5, 0.7 mm) and two groups of veneering ceramic specimen were prepared for analysis. Color parameter($L^*,a^*,b^*$) and color difference of zirconia core squares and core-veneer specimens were measured with ShadeEye $NCC^{(R)}$ spectrophotometer, respectively. Mean color difference(${\Delta}E^*$)were calculated using color difference formula. Two-way analysis of variance(ANOVA) combined with a Tukey multiple-range test were used to analysis the data(${\alpha}=0.05$). ${\Delta}E^*$ values were not significantly affected by core thickness and veneering porcelain(p=0.083). The color differences(${\Delta}E^*$) of core-veneer specimens with 0.5, 0.7 mm-A1,A2,A3.5 shade were mostly below 3.7 which was within the clinically acceptable range, while color differences between 0.3 mm-A1,A2 showed more than 3.7. All-ceramic system has color characteristics that clinicians have to consider when selecting materials. Also, manufacturers of different porcelain systems must make every effort to achieve color reproducibility.

A STUDY ON THE BOND STRENGTH OF REINFORCED INDIRECT COMPOSITE RESINS TO DENIAL ALLOYS (강화형 간접복합레진과 치과용 합금의 결합강도에 관한 연구)

  • Yoon, Dong-Joo;Shin, Sang-Wan;Lim, Ho-Nam;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.620-639
    • /
    • 1999
  • Indirect composite resins are used as an popular effective esthetic material in prosthetic dentistry, often with metallic substructure that provides support for restorations. Recently, new indirect composite resins as a substitute of ceramic have been developed. These resins provide good esthetics, with a wide range of hue and chroma. And the flexural strength of those is in the range of 120-150MPa, Which is higher than that of feldspathic Ceramic, and similar th that of Dicor. Although it has many merits, one of the major clinical problems of composite resins is the bond failure between metal and resin due to insufficient interfacial bond strength. The purpose of this study was to evaluate shear bond strength of the reinforced indirect composite resin to dental alloys. Three different composite resin systems($Artglass^{(R)},\;Sculpture^{(R)},\;Targis^{(R)}$) as test groups and ceramic($VMK\;68^{(R)}$) as control group were bonded to Ni-Cr-Be alloy($Rexillium\;III^{(R)}$) and gold alloy(Deva 4). All specimens were stored at $^37{\circ}C$ distilled water for 24 hours and the half of specimens were thermocycled 2000 times at temperature from $5^{\circ}C\;to\;60^{\circ}C$. The shear bond strengths of reinforced indirect composite resins to dental alloys were measured by using the universal testing machine, and modes of debonding were observed by stereoscope and scanning electron microscope. The results were as follows: 1 The shear bond strengths of reinforced indirect composite resins to dental alloys were approximately half those of ceramic to dental alloys(P<0.01). 2. There was no significant difference between the shear bond strength of several reinforced indirect composite resins to metal. 3. Alloy type did not affect on the shear bond strengths of resin to metal, but the shear bond strengths of ceramic to gold alloys were higher than those of ceramic to Ni-Cr alloys(P<0.05). 4. The shear bond strengths of Artglass and Targil to gold alloys were significantly decreased after thermocycling treatment(P<0.01). 5. Sculpture showed cohesive, adhesive, and mixed failure modes, but Artglass and Targis showed adhesive or mixed failures. And ceramic showed cohesive and mixed failures.

  • PDF

A Study on the Shear Bond Strength of the Reinforced Composite Resin to Dental Alloys (강화형 복합레진과 수종의 치과용 합금간의 전단결합강도에 관한 연구)

  • Kim, Jung-Hee;Jo, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.113-122
    • /
    • 2000
  • The reinforced composte resin as the esthetic operative material continuously has been studied because the porcelain fused metal prosthesis is widely used for its excellent esthetics, rigidity and marginal integrity, but it has low fracture resistance against the tensile strength and stress, attrition of the opposite teeth. The reinforced composite resin is well adapt with the dental alloy but it is low the shear bond strength with the dental alloy vs the porcelain fused metal prosthesis, and then has been studied continuously. The purpose of the study was to examine how metal was the higher shear bond strength among the dental alloy was used to the reinforced composite resin and to find the effect that the particle size of sandblasting influenced the shear bond strength. We built up the reinforced composite resin with 4 mm in diameter, 3 mm in height on circular alloy with 5 mm in diameter, 2 mm in height. Type II gold, type IV gold, and Ag-Pd alloy was used as alloys and $50{\mu}m$, $110{\mu}m$, $250{\mu}m$ of the particle size was sandblasted at each alloy in bonding between alloy and resin. We made 90 secimens of 10 per each group and we measured the shear bond strength using the Instron($M100EC^{(R)}$, Mecmesin Co., England). The obtained results were as follows : 1. In comparison among each alloys, Ag-Pd alloy had the highest shear bond strength and the shear bond strength was decreased significantly in the sequence of the type II gold and type IV gold(P<0.001). 2. In comparison according to the size of sandblasting particle, (1) In Ag-Pd alloy, shear bond strength was decreased in the sequence of $110{\mu}m$, $250{\mu}m$, $50{\mu}m$ and there were significant difference in all the group. (P<0.05) (2) In type II gold, it was decreased in the sequence of $250{\mu}m$, $50{\mu}m$, $110{\mu}m$ and there were significant difference. (P<0.05) (3) In type IV gold, it was decreased in the sequence of $110{\mu}m$, $50{\mu}m$, $250{\mu}m$. There were significant difference between the group of $110{\mu}m$ and $50{\mu}m$, the group of $110{\mu}m$ and 250, but there were no significant difference in the group of $50{\mu}m$ and $250{\mu}m$. 3. The highest shear bond strength according to the size of sandblasting particle was $110{\mu}m$ in Ag-Pd alloy and type IV gold, $250{\mu}m$ in type II gold.

  • PDF

Diagnostic keys of the overcoming risk factors and achieving predictable esthetics in anterior single implant

  • Choi, Geun-Bae;Yang, Jong-Sook
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.16 no.2
    • /
    • pp.7-18
    • /
    • 2007
  • There is now an increased demand for harmony between the peri-implant gingiva and adjacent dentition. In the event of a pending loss of a single tooth in the aesthetic zone with healthy periodontium, expectation for optimal gingival and prosthodontic aesthetics are often very high. Unfortunately, bone resorption is common following the removal of an anterior tooth, compromising the gingival tissue levels for the eventual implant restoration. Also, improper implant placement and inadequate osseous-gingival support potentially deleterious aesthetic result. The creation of an esthetic implant restoration with gingival architecture that harmonizes with the adjacent dentitionis formidable challenge. The predictability of the peri-implant esthetic outcome may ultimately be determined by the patient's own presenting anatomy rather than the clinician's ability to manage state-of-the-art procedures. To more accurately predict the peri-implant esthetic outcome before removing a failing tooth, a considering of diagnostic keys is essential. This presentation addresses the useful diagnostic keys that affect the predictability of peri-implant gingival aesthetics and the overcoming of the risk factors in anterior single-tooth replacement; it also describes a surgical and prosthodontic technique in achieving a long term successful esthetic outcome. Proper diagnosis and understanding of the biological and periodontal variables of failing dentition and their response to surgical and prosthodontic procedures are the essence of predictability. Using a smart protocol that alters the periodontium toward less risk and more favorable assessment of the diagnostic keys before implant placement will provide the most predictable esthetic outcome. Simple diagnostic keys suggested this presentation are useful method to evaluate the overcoming of the risk factors in anterior single implant restoration.

  • PDF