• Title/Summary/Keyword: Erythrocyte Sedimentation Rate(ESR)

Search Result 98, Processing Time 0.027 seconds

Electrophoretic analysis of the major proteins of race horse erythrocyte membrane: Their relation to fast erythrocyte sedimentation rate (경주 적혈구막 단백의 전기영동법에 의한 분석 -빠른 적혈구 침강 속도와의 관계-)

  • Bahk, Yeong-woo;Lee, Si-yeong
    • Korean Journal of Veterinary Research
    • /
    • v.31 no.3
    • /
    • pp.259-264
    • /
    • 1991
  • The proteins of the race horse erythrocyte membrane were analysed by polyacrylamide gel electrophoresis in sodium dodecyl sulfate(SDS-PAGE), and their relations to the fast erythrocyte sedimentation rate(ESR) of the race horse were investigated. The erythrocyte sedimentation rate of race horse were very fast compared with the human one(33 times <$90^{\circ}-plastic-ESR/30m$> and 25 times <$90^{\circ}-micro-ESR/30m$> as fast as the human one) are reported previously. Although the general protein profiles of the race horse erythrocyte membranes were almost similar to that of human, band 3 content was showing higher in race horse (34.7%) than in human (25.3%). The glycoprotein profiles of the race horse erythrocyte membranes revealed by periodic acid Schiff's(PAS) stain showed a marked difference from that of human. The PAS-1(glycophorin) and PAS-2(sialoglycoprotein) present in human erythrocyte memo brane were almost absent from the Holstein and race horse erythrocyte membranes, but PAS-2 was more in only race horse from that of human. Instead, the bovine erythrocyte membranes showed a strong PAS-B near the origin of the electrophorograms and the race horse erythrocyte membranes showed a strong PAS-negative band near the end of the electrophorograms, which is named as PAS-E in this study. These results suggest that the fast sedimentation rate of race horse erythrocyte is due in part to the presence of more band 3 protein fraction and PAS-E glycoproteins in the race horse erythrocytes.

  • PDF

Study on the Erythrocyte Sedimentation Rate by Angled Tube Method during Pregnant Period in Holstein (Holstein의 임신기간별 경사시험관법에 의한 적혈구 침강율 연구)

  • 신종욱;김형욱
    • Journal of Veterinary Clinics
    • /
    • v.16 no.1
    • /
    • pp.8-12
    • /
    • 1999
  • The erythrocyte sedimentation rate (ESR) test could be applied well in clinic of men, horses or dogs. But the ESR test was not applied to clinic ruminants except for buffaloes since it was too low measure. To overcome this problem angled tube method was developed. This method was found to be useful for making diagnosis and prognosis. The results were summarized as follows. 1. In the early pregnancy condition, corrected ESR did not changed when compared with normal valures. 2. In the middle pregnancy condition, corrected ESR was increased when compeared with normal valures. 3. In the latter pregnancy condition, corrected ESR was increased when compeared with normal valures. 4. After parturition condition, corrected ESR did not changed when compeared with normal valures.

  • PDF

Erythrocyte Sedimentation Rate: Its Determinants and Relationship with Risk Factors Involved in Ischemic Stroke

  • Kaur, Kirandeep;Kaur, Amandeep;Kaur, Anupam
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • Erythrocyte sedimentation rate (ESR) evaluation is a useful tool for monitoring disease activity in various inflammatory and non-inflammatory conditions. ESR is known to be influenced by a multitude of confounding factors. The present study aimed to assess the possible determinants of the ESR and its relationship with various risk factors involved in ischemic stroke. ESR and other hematological and biochemical parameters were investigated in 163 ischemic stroke patients (107 males and 56 females) selected based on imaging techniques including magnetic resonance imaging (MRI) or computed tomography (CT) scans. Statistical analysis was performed using the SPSS 16.0 software. Linear regression analysis showed a significant inverse relationship of hemoglobin (Hb) and hematocrit or packed cell volume (PCV) (P<0.001 for females; P<0.01 for males) with the ESR. It was observed that the red blood cell (RBC) count was not strongly correlated with the ESR (P<0.05 for both males and females). It was also observed that sex significantly affected the variables determining the ESR levels, whereas age had no effect. Gender differences were also observed with respect to Hb, RBC, PCV, mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), and ESR. The possible determinants of higher ESR levels in ischemic stroke may be sex, Hb, hematocrit, and RBC count, but the role of other clinical and laboratory parameters cannot be underestimated.

Comparative Evaluation of Erythrocyte Sedimentation Rate by the Test 1 Analyzer and Westergren method in Patients with Anemia (빈혈환자에서 자동 ESR 기기인 Test 1과 Westergren법의 비교)

  • Kim, Il Taek;Kim, Jong Seok;Park, Yeon Bo;Lim, Jae Sil
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.137-143
    • /
    • 2004
  • Erythrocyte sedimentation rate(ESR) measurements were performed in a total of 191 blood samples from patients below a hematocrit of 35% by both the Test-1(SIRE Analytical Systems, Udine, Italy) and the Westergren method, endorsed as the reference method for ESR by the International Council for Standardization in Hematology(ICSH). The corrected Westergren ESR values were also obtained applying the formula of Fabry (corrected ESR = ESR measured x 15/55-Hct). Linear regression analysis showed a close correlation (r=0.85) between the two methods both before and after ESR correction in total samples. There was no significant correlation difference between two methods in both two groups with hemoglobin $${\geq_-}9g/dl$$ and <9g/dl before and after ESR correction (r=0.873, r=0.827 respectively before correction and r=0.867, r=0.830 respectively after correction). Also, for two groups with hematocrit $${\geq_-}24%$$ and <24%, no significant difference was observed (r=0.859, r=0.792 respectively before correction and r=0.782, r=0.842 respectively after correction). However, for samples with <60mm of Westergren ESR before correction, a better correlation coefficient was obtained than samples with $${\geq_-}60mm$$(r=0.701, r=0.541 respectively). In corrected Westergren ESR, also samples that were obtained with <40mm showed better correlation than samples with $${\geq_-}40mm$$ (r=0.690, r=0.347 respectively). In conclusion, we found a good correlation between Test-1 and Westergren measurements in patients with anemia but an expert group discussion is required to solve discrepancy between two methods in blood samples with very high ESR.

  • PDF

Investigation of High-Sensitivity C-reactive Protein and Erythrocyte Sedimentation Rate in Low Back Pain Patients

  • Park, Chan-Hong;Lee, Sang-Ho
    • The Korean Journal of Pain
    • /
    • v.23 no.2
    • /
    • pp.147-150
    • /
    • 2010
  • Background: Chronic low back pain can be a manifestation of lumbar degenerative disease, herniation of intervertebral discs, arthritis, or lumbar stenosis. When nerve roots are compromised, low back pain, with or without lower extremity involvement, may occur. Local inflammatory processes play an important role in patients with acute lumbosciatic pain. The purpose of this study was to assess the value of erythrocyte sedimentation rate (ESR) and high sensitivity C-reactive protein (hsCRP) measurements in patients with chronic low back pain or radiculopathy. Methods: ESR and hsCRP were measured in 273 blood samples from male and female subjects with low back pain and/or radiculopathy due to herniated lumbar disc, spinal stenosis, facet syndrome, and other diseases. The hsCRP and ESR were measured prior to lumbar epidural steroid injection. Results: The mean ESR was 18.8 mm/h and mean hsCRP was 1.1 mg/L. ESR had a correlation with age. Conclusions: A significant systemic inflammatory reaction did not appear to arise in patients with chronic low back pain.

Indirect calculation for volume of packed red cell(VPRC) by means of erythrocyte sedimentation rate (ESR) of blood diluted with isotonic dextrose solution in cattle (소에 있어서 등장 dextrose액으로 희석한 혈액의 적혈구 침강율(ESR) 측정에 의한 적혈구 침층용적(VPRC)치의 간접계산법)

  • Lee, Bang-whan;Bahk, Young-woo;Min, Byeong-man
    • Korean Journal of Veterinary Research
    • /
    • v.30 no.1
    • /
    • pp.107-112
    • /
    • 1990
  • The purpose of this study is to derive indirect values of volume of packed red cell(VPRC), without centrifugation, from erythrocyte sedimentation rate(ESR) of blood diluted with isotonic dextrose solution in cattle. Each of ten blood samples taken from apprently healthy Korean cows and Holstein cows was used to produce eight different mixture of autologous plasma and blood corpuscles such that their values of VPRC lay between 15 to 50ml/100ml, and then each of the blood mixture was again diluted with 5% dextrose solution. The measurements of ESR using 45 degree-angled capillary hematocrit tube, 1.1~1.2mm bore, ($45^{\circ}$-micro-ESR) were practised for the diluted blood of various levels of VPRC under the ambient temperature of $10^{\circ}$, $20^{\circ}$ and $30^{\circ}C$. Reliable values of VPRC on the basis of the correlating linear regressive equation to the ESR could be derived from the values of $45^{\circ}$-micro-ESR/hr in the mixture of one part of whole blood and one part of 5% dextrose solution(1:1). For an aid of practical use, authors suggested a list of the $45^{\circ}$-micro-ESR/hr values of the diluted blood equivalent to VPRC of whole blood.

  • PDF

Evaluation of erythrocyte sedimentation rate in racehorse measured by westergren method (경주마(競走馬)에서 Westergren법(法)에 의한 적혈구 침강속도(沈降速度) 측정의 평가(評價))

  • Kim, Byoung-jin;Lee, Bang-whan;Lee, Chai-yong
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.3
    • /
    • pp.421-427
    • /
    • 1992
  • The study was basically carried out to establish the appropriate condition for applying the Westergren method for erythrocyte sedimentation rate(W-ESR) in Throughbred racehorses at recess. To do this, we examined the correlationship among some factors including the kind of anticoagulants, optimal ambient temperature and reading time for W-ESR in healthy racehorses. The difference between the blood samples treated with only 3.8% solution of sodium citrate(SC) and both EDTA and SC as a coagulant, there was not recognized any significant difference(p<0.05) in the levels of W-ESR irrespective of the ambient temperature of $20^{\circ}C$ or $30^{\circ}C$. The best optimal ambient temperature for W-ESR in horses was proved at $30^{\circ}C$ resulting from the tendency of the most reduced dispersion in mean values analyaed from repeatly 4 times to the same blood samles compared with those of $10^{\circ}C$ and $20^{\circ}C$. The optimal reading time was determined as 60 minutes(Y=237.2~4.1X, $r^2=0.998$) and 70 minutes(Y=247.8~4.2X, $r^2=0.999$) under the same temperature of $30^{\circ}C$; the latter showed the better result on the basis of the correlation of packed cell volume(PCV) and ESR values. About 13 healthy racehorses, we compared the real values of W-ESR respectively obtained at 60 minutes and 70 minutes at $30^{\circ}C$ with the anticipated values of PCV by means of the analysis of linear regression equitation. As the result of this, the strong correlation between both of them was confirmed. For practical use of W-ESR in Thoroughbred racehorese, we can recommend the condition of 60 or 70 minutes for the optimal reading time as well as $30^{\circ}C$ for the best ambient temperature.

  • PDF

Forecasting of erythrocyte sedimentation rate using gated recurrent unit (GRU) neural network (Gated recurrent unit (GRU) 신경망을 이용한 적혈구 침강속도 예측)

  • Lee, Jaejin;Hong, Hyeonji;Song, Jae Min;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.1
    • /
    • pp.57-61
    • /
    • 2021
  • In order to determine erythrocyte sedimentation rate (ESR) indicating acute phase inflammation, a Westergren method has been widely used because it is cheap and easy to be implemented. However, the Westergren method requires quite a long time for 1 hour. In this study, a gated recurrent unit (GRU) neural network was used to reduce measurement time of ESR evaluation. The sedimentation sequences of the erythrocytes were acquired by the camera and data processed through image processing were used as an input data into the neural network models. The performance of a proposed models was evaluated based on mean absolute error. The results show that GRU model provides best accurate prediction than others within 30 minutes.

Relative Anticipated Erythrocyte Sedimentation Rate of Cattle Blood, as Measured by 45 Degree-Angled Capillary Hematocrit Tube, for Ambient Temperature and PCV Value (소 혈액의 45도 경사 모세관에 의한 ESR측정에 있어서 환경온도 및 PCV에 상관하는 관계적 예기ESR치)

  • Lee, Bang-whan
    • Korean Journal of Veterinary Research
    • /
    • v.27 no.2
    • /
    • pp.339-345
    • /
    • 1987
  • Each of twenty blood samples taken from apparently healthy Korean Cows was used to produce five different mixtures of autologous plasma and blood corpuscles such that their values of packed cell volume (PCV) lay between 10 to 50ml/l00ml. The measurements of erythrocyte sedimentation rate (ESR) using 45 degree-angled capillary hematocrit tube, 1.1-1.2mm bore, ($45^{\circ}-micro-ESR$) were practised for the blood of various levels of PCV under the ambient temperature of ${10^{\circ}C}$, ${20^{\circ}C}$ and ${30^{\circ}C}$. Correlation of ESR to ambient temperature showed linear regression each in five levels of PCV. ESR increased with ascending ambient temperature, and magnitude of the increase of ESR became greater as the level of PCV lowered. Correlation of ESR, of which values were transformed by the linear regression equation correlated to ambient temperature to PCV showed curvilinear regression each in three levels of ambient temperature, and ESR was increased with decreasing PCV. The data were statistically analysed and a list of relative anticipate $45^{\circ}-micro-ESR$ values for PCV and ambient temperature was presented.

  • PDF

Indirect calculation for volume of packed red cell(VPRC) by means of erythrocyte sedimentation rate(ESR) of diluted blood in dogs (개 회석혈의 적혈구침강율(ESR)에 의한 적혈구 침층용적(VPRC)치의 간접계산법)

  • Lee, Bang-whan;Park, Young-jun
    • Korean Journal of Veterinary Research
    • /
    • v.29 no.2
    • /
    • pp.41-49
    • /
    • 1989
  • The study was undertaken to obtain indirect values of volume of packed red cell (VPRC) without centrifugation, using the erythrocyte sedimentation rate (ESR) of diluted blood in dogs. ESRs of diluted blood using the diluent of autologous plasma in which formed numerous RBC-rouleau clumps, autologous serum in which formed a few RBC-rouleau clumps, and 5% dextrose or 6% sucrose solutions in which formed numerous RBC-aggregation clumps, were accelerated. But, ESR of diluted blood using the 0.9% saline, D-S, ACD-B, CDP or D-PBS solutions were sluggish, because erythrocytes were dispersed in these diluents. Reliable values of VPRC on the basis of the correlating regressive equation to the ESR could be derived from values of$60^{\circ}$-angled-micro-ESR/40 min in the mixture, four parts of 5% dextrose solution and one part of whole blood. In the ESR values of diluted blood with low ratio, 1:1~3:1, $60^{\circ}$-micro-ESR was higher than $60^{\circ}$-Wintrobe-ESR. But, in the diluted blood with high ratio, 4:1~5:1, there was no different ESR values. For an aid of practical use, authers suggested a list of the $60^{\circ}$-micro-ESR/40 min in the diluted blood with equivalent VPRC of whole blood.

  • PDF