• Title/Summary/Keyword: Error monitoring system

검색결과 589건 처리시간 0.033초

무선데이타 통신을 이용한 실시간 타공사 감시 시스템 개발 (Development of Real Time Monitoring System for third party damage Detection Using Wireless Data Communicating)

  • 박승수;조성호;유휘룡;김동규;전경수;박대진;구성자;노용우
    • 한국가스학회지
    • /
    • 제4권3호
    • /
    • pp.59-64
    • /
    • 2000
  • 배관에 가해지는 충격을 실시간으로 모니터링하고, 충격위치를 산출 할 수 있는 모니터링 시스템을 무선데이타 통신을 이용하여 개발하였고, 마산만 해저배관에 현장적용 후 충격실험을 통하여 유용성을 검증하였다. 실험에 사용된 배관은 총 길이 1365m, 운용압력 8.6kgf/cm^2$$, 직경 12inch인 실제 운용중인 해저가스배관을 사용하였다. 충격실험에서 충격위치 계산오차는 배관내에서 충격음파 속도의 $1\%$정도의 거리였다.

  • PDF

아크 점용접 구조물의 정밀 용접 열변형 해석에 관한 연구 (II) - 변위 모니터링 및 변형 모델 정립 - (The Analysis of Welding Deformation in Arc-spot Welded Structure (II) - Displacement Monitoring and Deformation Analysis -)

  • 장경복;조상명
    • Journal of Welding and Joining
    • /
    • 제21권4호
    • /
    • pp.80-86
    • /
    • 2003
  • Arc-spot welding is generally used in joining of precise parts such as case and core in electric compressor. It is important to control joining deformation in electric compressor because clearance control of micrometer order is needed for excellent airtightness and anti-nose. The countermeasures for this deformation in field have mainly been dependent on rule of try and error by operator's experience because of productivities. For control this deformation problem without influence on productivities, development of exact simulation model should be needed. In this study, on the basis of previous study, the analysis model io predict deformation of precise order in arc-spot welded structure with non-uniform stiffness is brought up through feedback and tuning between monitoring data and analysis results. For this, deformation monitoring system was built and boundary condition considering mechanical melting temperature was applied.

아두이노 기반의 효율적인 홈 시큐리티 모니터링 시스템 설계 및 구현 (Design and Implementation of Arduino-based Efficient Home Security Monitoring System)

  • 이형로;인치호
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권2호
    • /
    • pp.49-54
    • /
    • 2016
  • 본 논문에서는 아두이노 기반의 효율적인 홈 시큐리티 모니터링 시스템을 제안한다. 제안하는 홈 시큐리티 모니터링 시스템은 비교적 가격이 저렴한 메인 프로세서인 아두이노와 초음파 센서, 인체 감지 센서를 이용하여 침입여부를 판단하도록 홈 시큐리티 시스템을 구성하였고, 초음파 센서와 인체 감지 센서의 데이터는 아두이노에 연결된 이더넷 쉴드를 통해 웹 서버로 전송하도록 설계하였다. 그리고 웹 서버에서는 저장된 초음파 센서와 인체 감지 센서 데이터를 이용하여 침입여부를 확인하고, JQuery를 이용하여 연결되어 있는 웹캠으로 스냅 샷을 촬영하도록 하였으며, 촬영 된 스냅 샷은 웹 서버에 이미지 파일로 저장되며, HTML5와 CSS, Canvas를 사용하여 사용자는 웹 또는 스마트 디바이스 환경에서 모니터링이 가능하도록 설계하였다. 제안된 홈 시큐리티 모니터링 시스템을 실제 구현함으로서 효율성 검증 결과 기존 홈 시큐리티 시스템에 비해 구성이 쉬워 도면을 보고 쉽게 제작이 가능하였으며, 아두이노를 이용하여 구성과 설치비에 대한 가성비가 뛰어났고, 개인이 오류에 대한 직접적인 대처가 가능해 비용에 대한 효율성과 편리성을 입증하였으며, 신뢰도 높은 데이터를 이용하여 안정적인 시스템 운영이 가능하였다.

기어피치분석 및 공정관측을 위한 PC기반시스템 구축 (A PC-Based System for Gear Pitch Analysis and Monitoring in Gear Manufacturing Process)

  • 김성준;지용수
    • 품질경영학회지
    • /
    • 제30권3호
    • /
    • pp.111-119
    • /
    • 2002
  • Gears are essential elements for mechanical power transmission. Geometric precision is the main factor for characterizing gear grade and qualify. Gear pitch is one of the crucial measurements, which is defined as a distance between two adjacent gear teeth. It is well-known that variability in gear pitches may causes wear-out and vibration noise. Therefore maintaining pitch errors at a low level plays a key role in assuring the gear quality to customers. This paper is concerned with a case study, which presents a computerized system for Inspecting pitch errors in a gear machining process. This system consists of a PC and window-based programs. Although the start and stop is manually accomplished, the process of measuring and analyzing pitch data is automatically conducted in this system. Our purpose lies in reducing inspection cost and time as well as Increasing test reliability. Its operation is briefly illustrated by example. Sometimes a strong autocorrelation is observed from pitch data. We also discuss a process monitoring scheme taking account of autocorrelations.

지중 금속구조물의 전기방식 원격감시시스템 개발 (The development of On-Line Cathodic Protection Monitoring System)

  • 임헌호;정성우;하희천
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 춘계학술대회 논문집
    • /
    • pp.213-218
    • /
    • 2001
  • These days, corrosion condition of a underground objects is measured by the electric potential between the subject and ground. But this method is implemented by means of manual work with analog voltmeter, which is uneconomic and inefficient. So, We developed real-time On-Line cathodic protection monitoring system that is able to detect corrosion potential conditions of metal objects or various steel structures in the ground continuously, display them with the graphic screen, construct a database, and analyze them simultaneously. Since the data of corrosion and corrosion protection of all underground objects is processed automatically, not manually in this system, It is possible to reduce the manipulated error, and perform precise safety management, maintenance and inspection. As as result, this system can not only guarantee long-life operation, reduction of manpower and cost, but prevent large accidents in advance.

  • PDF

무인 설비 감시용 레일 가이드 구동장치에서 BLDC 전동기의 위치 제어 (A Position Control of BLDC Motor in a Rail Guided System for the Un-maned Facility Security)

  • 배종남;이동희
    • 전력전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.223-230
    • /
    • 2017
  • A low-cost BLDC motor with hall sensor is used to drive the position control of a facility security monitoring system in this paper. Low measurable frequency of the hall sensor signal in low-speed regions results in difficulty in obtaining accurate speed detection and position control. To improve system control performance, we propose a variable gain of position controller and stop mode control scheme according to the motor speed and error position with pre-set deceleration time. The proposed stop mode control scheme is activated around the stop position to forcibly move the BLDC motor to the stop position in low speed. In the proposed stop mode, the motor current is controlled by the actual speed with the reference rotating angle. The control performance of the proposed position control is verified through experiments at the actual rail guided facility security monitoring system.

Monitoring QZSS CLAS-based VRS-RTK Positioning Performance

  • Lim, Cheolsoon;Lee, Yebin;Cha, Yunho;Park, Byungwoon;Park, Sul Gee;Park, Sang Hyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제11권4호
    • /
    • pp.251-261
    • /
    • 2022
  • The Centimeter Level Augmentation Service (CLAS) is the Precise Point Positioning (PPP) - Real Time Kinematic (RTK) correction service utilizing the Quasi-Zenith Satellite System (QZSS) L6 (1278.65 MHz) signal to broadcast the Global Navigation Satellite System (GNSS) error corrections. Compact State-Space Representation (CSSR) corrections for mitigating GNSS measurement error sources such as satellite orbit, clock, code and phase biases, tropospheric error, ionospheric error are estimated from the ground segment of QZSS CLAS using the code and carrier-phase measurements collected in the Japan's GNSS Earth Observation Network (GEONET). Since the CLAS service begun on November 1, 2018, users with dedicated receivers can perform cm-level precise positioning using CSSR corrections. In this paper, CLAS-based VRS-RTK performance evaluation was performed using Global Positioning System (GPS) observables collected from the refence station, TSK2, located in Japan. As a result of performing GPS-only RTK positioning using the open-source software CLASLIB and RTKLIB, it took about 15 minutes to resolve the carrier-phase ambiguities, and the RTK fix rate was only about 41%. Also, the Root Mean Squares (RMS) values of position errors (fixed only) are about 4cm horizontally and 7 cm vertically.

잡음영향의 저감을 위한 두 디지털 필터들의 사용에 의한 DFT 기반의 계통주파수 추정 (DFT-based Power System Frequency Estimation using Two Digital Filters for Noise Effect Reduction)

  • 황진권
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.891-897
    • /
    • 2013
  • The power system frequency plays an important role in monitoring and controlling the power system. The frequency can be measured through discrete Fourier transform (DFT) coefficients of its positive fundamental frequency. The accuracy of the frequency estimate is severely affected by noise in the power system signal and the leakage effect of the negative fundamental frequency in DFT. This paper proposes a DFT-based frequency estimation algorithm to cope with the noise as well as the leakage effect. In this algorithm, two suitable digital filters are introduced to reduce efficiently frequency estimate error due to the noise. These filters are designed to use a digital bandpass filter and a second-degree integrator. The effectiveness of the proposed algorithm in reduction of frequency estimate error is verified through simulations on noise, harmonics and frequency deviation.

지중 금속구조물 부식감시를 위한 영구매설용 기준전극 개발 (Development of Permanent Reference Electrode for Corrosion Monitoring of Underground Metallic Structures)

  • 하윤철;배정효;하태현;이현구;이재덕;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.532-534
    • /
    • 2004
  • The advancement of electronics and telecommunication technologies has forced the risk management system for underground metallic structures to evolve into the remote monitoring and control system. Especially, facilities such as gas pipelines, oil pipelines and water distribution lines might make hazardous effect on human safety without continuous monitoring and control. As a result, pipeline engineers have applied cathodic protection system to prevent the degradation of their facilities by corrosion and carried out a periodic monitoring of the pipe-to-soil (P/S) potentials at numberous test boxes along their pipelines. The latter action on a road in downtowns, however, is so much dangerous that the inspectors should be ready to suffer the threatening of their lives and maintenance. In order to minimize these social costs and hazards, a stand-alone type corrosion monitoring equipment which can be installed in test box, store the P/S data for given Belied and send the data by wired/wireless telecommunications is under development. In order to obtain the exact P/S data, however, a reference electrode should be located as close to the pipeline as possible. Actually, the measured potential by a conventional portable reference electrode contain inevitably an IR drop portion caused by the current flow from the cathodic protection rectifier or the subway railroad. To minimize this error, it is recommended that the reference electrode should be buried within 10 cm from the pipeline. In this paper, we describe the design parameters for fabricating the permanent type reference electrode and the characteristics of the developed reference electrode.

  • PDF