• Title/Summary/Keyword: Error level

Search Result 2,511, Processing Time 0.028 seconds

Enhancement of Sound Image Localization on Vertical Plane for Three-Dimensional Acoustic Synthesis (3차원 음향 합성을 위한 수직면에서의 음상 정위 향상)

  • 김동현;정하영;김기만
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.3
    • /
    • pp.541-546
    • /
    • 1999
  • The head-related transfer function (HRTF), which expresses the acoustic process from the sound source to the human ears in the free field, contains critical informations which the location of the source can be traced. It also makes it possible to realize multi-dimensional acoustic system that can approximately generate non-existing sound source. The use of non-individual, common HRTF brings performance degradation in localization ability such as front-back judgment error, elevation judgment error. In this paper, we have reduced the error on vertical plane by increasing the spectral notch level. The performance of the proposed method was Proved through subjective test that it is Possible to improve the ability to locate stationary/moving source.

  • PDF

Optimized Integer Cosine Transform (최적화 정수형 여현 변환)

  • 이종하;김혜숙;송인준;곽훈성
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.9
    • /
    • pp.1207-1214
    • /
    • 1995
  • We present an optimized integer cosine transform(OICT) as an alternative approach to the conventional discrete cosine transform(DCT), and its fast computational algorithm. In the actual implementation of the OICT, we have used the techniques similar to those of the orthogonal integer transform(OIT). The normalization factors are approximated to single one while keeping the reconstruction error at the best tolerable level. By obtaining a single normalization factor, both forward and inverse transform are performed using only the integers. However, there are so many sets of integers that are selected in the above manner, the best OICT matrix obtained through value minimizing the Hibert-Schmidt norm and achieving fast computational algorithm. Using matrix decomposing, a fast algorithm for efficient computation of the order-8 OICT is developed, which is minimized to 20 integer multiplications. This enables us to implement a high performance 2-D DCT processor by replacing the floating point operations by the integer number operations. We have also run the simulation to test the performance of the order-8 OICT with the transform efficiency, maximum reducible bits, and mean square error for the Wiener filter. When the results are compared to those of the DCT and OIT, the OICT has out-performed them all. Furthermore, when the conventional DCT coefficients are reduced to 7-bit as those of the OICT, the resulting reconstructed images were critically impaired losing the orthogonal property of the original DCT. However, the 7-bit OICT maintains a zero mean square reconstruction error.

  • PDF

A Novel MPPT Control of PV MIC System Considering the Shaded Effect (그림자 영향을 고려한 PV MIC 시스템의 새로운 MPPT 제어)

  • Choi, Jung-Sik;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.21-33
    • /
    • 2012
  • This paper presents the new maximum power point tracking(MPPT) control of the photovoltaic(PV) module integrated converter(MIC) system considering the shadow influence. The output characteristics of the solar cell is a nonlinear and affected by a temperature, the solar radiation and influence of a shadow. Particularly, MIC system is very sensitive to the shadow influence because the capacity is very small. In order to increase an output and efficiency of the solar power generation, the maximum power point(MPP) obeying control are necessary. Conventional perturbation and observation(PO) and Incremental conductance(IC) are the method finding MPP by the continued self-excitation vibration. The MPPT control is unable to be performed by rapid output change affected by the shadow. To solve this problem, the new control algorithm of the multi-level in which the step value changes by output change is presented. In case there are the solar radiation, a temperature and shadow influence, the presented algorithm treats and compares the conventional control algorithm and output error. In addition, the validity of the algorithm is proved. through the output error response characteristics.

A Study on Efficient Packet Design for Underwater Acoustic Communication (수중음향통신에서 효율적인 패킷 설계에 관한 연구)

  • Park, Tae-Doo;Jung, Ji-Won
    • Journal of Navigation and Port Research
    • /
    • v.36 no.8
    • /
    • pp.631-635
    • /
    • 2012
  • Underwater acoustic communication has multipath error because of reflection by sea-level and sea-bottom. The multipath of underwater channel causes signal distortion and error floor. In this paper, in order to design an efficient packet structure, we employ channel coding scheme and phase recovery algorithm. For channel coding scheme, half rate LDPC channel coding scheme with N=1944 and K=972 was used. Also, decision directed phase recovery was used for correcting phase offset induced by multipath. Based on these algorithms, we propose length of data for optimal packet structure in the environment of oceanic experimentation.

A Study on Hardened Properties and Durability of Concrete according to Unit-Water Content (배합수량 변동에 따른 콘크리트의 경화성상 및 내구성에 관한 연구)

  • Koo, Kyung-Mo;Lim, Chang-Hyuck;Lee, Eui-Bae;Kim, Young-Sun;Kim, Young-Duck;Kim, Gyu-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.45-48
    • /
    • 2009
  • The performance of concrete mainly depend upon its water-cement ratio. If water percentage is excess in concrete, it may cause the degradation of performance. Because of these reasons, the change of water content is managed by using various evaluation method of unit water content. And criterion for the change of water content is regulated and used. However the criterion is set only considering production error and measurement error but criterion does not consider performance degradation of concrete. Therefore this study tries to investigate degradation of performance while adding extra water by artificial manipulation or management error in concrete, The contents of extra water for tests are set as 0, 20, 40, 60kg/m3, to examine the performance degradation of concrete, strength, shrinkage, cracks, carbonation are tested This study conclude that, when extra water content is excess than 20kg/m3 in concrete, then performance level of concrete declined rapidly. 80 it is very important to maintain quality of concrete for its better performance.

  • PDF

Multi-Access Points Transmit Power Control Algorithm in Consideration of the Channel Estimation Error and the Multi Rate Service (채널추정 에러와 다중 전송률 서비스를 고려한 다수 개의 엑세스포인트 전송전력제어 알고리즘)

  • Oh, Changyoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.4
    • /
    • pp.39-47
    • /
    • 2020
  • We propose a multi-access points transmit power control algorithm in consideration of the channel estimation error and the multi-rate service. In the real communication systems, the channel estimation at the receiver side is imperfect due to limited number of pilot symbol usage. Furthermore, the multi-rate service is supported. We theoretically prove the uniqueness and the convergence of the proposed algorithm in multi-rate service environment. The proposed algorithm composes of one inner loop part and one outer loop part. Simulation results show that 1) the inner loop algorithm guarantees convergence of the transmit power level and the multi-rate service, 2) the outer loop algorithm compensates for the channel estimation error.

Bus Clamping PWM Based Hysteresis Current Controlled VSI Fed Induction Motor Drive with Nearly Constant Switching Frequency

  • Peter, Joseph;Mohammed Shafi, KP;Ramchand, Rijil
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1523-1534
    • /
    • 2017
  • A Current Error Space Phasor (CESP) based hysteresis controller with online computation of the boundary for two-level inverter fed Induction Motor (IM) drives is presented in this paper. The stator voltages estimated along the ${\alpha}$-and ${\beta}$-axes and the orthogonal current error components of the motor are used in the online computation of the hysteresis boundary. All of the inherent benefits of space phasor based hysteresis controllers such as its quick dynamic response and nearby voltage vector switching are present in the proposed scheme with the added benefit of suppressing switching frequency variations. The similarity in the frequency spectrum of the phase voltage obtained at the output of the inverter using the proposed scheme and Bus Clamping Pulse Width Modulation (BCPWM) based drive is justified with the help of extensive MATLAB SIMULINK simulations. The controller is experimentally verified with a three phase, 2.2 kW IM drive for steady state and transient conditions and the obtained results match the simulation results.

A study for the Error performance of M-FSK system on the Low frequency band (저주파 대역에서 M레벨 FSK시스템의 오율에 관한 연구)

  • Kim, Seong-Cheol;Park, Kyung-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.9
    • /
    • pp.1672-1678
    • /
    • 2007
  • The communication systems and characteristics of transmit are very importance a serious view of ubiquitores society. The high rate systems have to construct for data of voice, graphics and moving-video with the multimedia to transmit on the low frequency band. The rate of data are relation that there are the bandwidth of line and channels, the bit per second and communication-systems. This paper study for the error performance of 2, 4 8 level FSK to transmit amount of data in the communication systems and design to FDM system.

Effects of Bank Macroeconomic Indicators on the Stability of the Financial System in Indonesia

  • VIPHINDRARTIN, Sebastiana;ARDHANARI, Margaretha;WILANTARI, Regina Niken;SOMAJI, Rafael Purtomo;ARIANTI, Selvi
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.1
    • /
    • pp.647-654
    • /
    • 2021
  • This study examines the non-performing loans of rural banks and macroeconomic factors in Indonesia, including inflation, exchange rates, and interest rates. Theoretically, the existence of erratic macroeconomic conditions can affect the level of non-performing credit risk in rural credit banks in Indonesia. The effect of macroeconomic conditions on non-performing loans has a different response for each economic sector. The main objective of this study is to determine the effect of macroeconomic factors (inflation, exchange rates, and interest rates) and bank-specific factors (credit) on the Non-Performing Loans (NPL) of Rural Banks in Indonesia for the period from January 2015 to December 2018. This study uses a Vector Error Correction Model (VECM) estimation to determine the effect of independent variables consisting of macroeconomic factors and bank-specific factors. Based on the estimation results of the Vector Error Correction Model, three variables that have a positive and significant effect on long-term non-performing loans are credit, inflation, and interest rates. Meanwhile, in the short term, there are only two variables that have a positive and significant effect on non-performing loans, namely, credit and interest rates. Inflation and exchange rate variables have a negative and insignificant effect on bad credit in the short term.

Performance Analysis of Electricity Demand Forecasting by Detail Level of Building Energy Models Based on the Measured Submetering Electricity Data (서브미터링 전력데이터 기반 건물에너지모델의 입력수준별 전력수요 예측 성능분석)

  • Shin, Sang-Yong;Seo, Dong-Hyun
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.627-640
    • /
    • 2018
  • Submetering electricity consumption data enables more detail input of end use components, such as lighting, plug, HVAC, and occupancy in building energy modeling. However, such an modeling efforts and results are rarely tried and published in terms of the estimation accuracy of electricity demand. In this research, actual submetering data obtained from a university building is analyzed and provided for building energy modeling practice. As alternative modeling cases, conventional modeling method (Case-1), using reference schedule per building usage, and main metering data based modeling method (Case-2) are established. Detail efforts are added to derive prototypical schedules from the metered data by introducing variability index. The simulation results revealed that Case-1 showed the largest error as we can expect. And Case-2 showed comparative error relative to Case-3 in terms of total electricity estimation. But Case-2 showed about two times larger error in CV (RMSE) in lighting energy demand due to lack of End Use consumption information.