• Title/Summary/Keyword: Error Variance

Search Result 727, Processing Time 0.023 seconds

Bioequivalence of Tagamet Tablet to Sinil CIMETIDINE Tablet (cimetidine 400 mg) (타가메트정 400 mg에 대한 신일시메티딘정 400 mg의 생물학적동등성시험)

  • Yoon, Mi-Kyeong;Lee, Byoung-Moo;Lee, Sung-Jae;Kim, Sun-Kyu;Lee, Jae-Hwi;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.6
    • /
    • pp.521-527
    • /
    • 2004
  • Cimetidine is a histamine $H_2-receptor$ antagonist, used for the treatment of endoscopically or radiographically comfirmed duodenal ulcer, pathologic GI hypersecretory conditions, and active, benign and gastric ulcer. Simple method for determining cimetidine in human plasma has been developed and validated. The analytical procedure for cimetidine showed a linear relationship in the concentration ranges from $0.05\;to\;5\;{\mu}g/ml$. Coefficient of variance (CV, %) for intraday and interday validation and relative error (RE, %) were less than ${\pm}15%$. Based on this analytical method, the bioequivalence of two cimetidine 400 mg tablets, reference (Tagamet 400 mg) and test drug (Sinil CIMETIDINE 400 mg) was evaluated according to the guidelines set by the Korea Food and Drug Administration (KFDA). Release of cimetidine from the tablets in vitro was tested using KP VIII Apparatus II with various dissolution media (pH 1.2, 4.0, 6.8 buffer solutions and water). Twenty-four healthy volunteers, $21.38{\pm}1.86$ years in age and $68.71{\pm}8.68\;kg$ in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was performed. After oral administration of a tablet containing 400 mg of cimetidine, blood samples were taken at predetermined time intervals and concentrations of cimetidine in plasma were determined using HPLC equipped with UV detector. The dissolution profiles of the two tablet formulations were very similar at all dissolution media. In addition, pharmacokinetic parameters such as $AUC_t$ and $C_{max}$ were calculated and ANOVA was employed for the statistical analysis of parameters. The results were revealed that the differences in $AUC_t$ and $C_{max}$ between the two tablets were 4.17 % and 0.97% respectively. At 90% confidence intervals, the differences in these parameters were also within ${\pm}20%$. All of the above mentioned parameters have met the criteria of KFDA guidelines for bioequivalence, indicating that the test drug tablet (Sinil CIMETIDINE tablet) is bioequivalent to Tagamet 400 mg tablet.

Impacts of Chemical Heterogeneities in Landfill Subsurface Formations on the Transport of Leachate (매립지반의 화학적 불균질성이 침출수 이동에 미치는 영향)

  • Lee Kun-Sang
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.5
    • /
    • pp.1-8
    • /
    • 2006
  • The objective of this study is to assess impacts of sorption heterogeneity on the transport of leachate leaked from unlined landfill sites and is accomplished by examining the results from a series of Monte-Carlo simulations. For random distribution coefficient ($K_{d}$) fields with four different levels of heterogeneity ranging from homogeneous to highly heterogeneous, the transport of leachate was investigated by linking a saturated flow model with a contaminant transport model. Impacts of a chemical heterogeneity were evaluated using point statistics values such as mean, standard deviation, and coefficient of variation of the concentration obtained at monitoring wells from 100 Monte-Carlo trials. Inspection of point statistics shows that the distribution of distribution coefficient in the landfill site proves to be an important parameter in controlling leachate concentrations. In comparison to homogeneous sorption, heterogeneous $K_{d^-}$ fields produce the variability in the leachate concentration for different realizations. The variability increases significantly as the variance in the $K_{d^-}$ field and the travel time between source and monitoring well increase. These outcomes indicate that use of a constant homogeneous $K_{d}$ value for predicting the transport of leachate can result in significant error, especially when variability in $K_{d}$ is high.

Analytical Study on the Potential Risks from Right-Handled Vehicle Drivers (우측핸들차량 운전자의 잠재적 위험성 분석연구)

  • Park, Jun-Tae;Kim, Jeong-Hyun;Kang, Young-Kyun;Kim, Jang-Wook
    • Journal of Korean Society of Transportation
    • /
    • v.30 no.2
    • /
    • pp.67-78
    • /
    • 2012
  • The current traffic regulations in Korea stipulate that traffic should keep to the right according to the Road Traffic Act; thus, customarily, the 'seat-on-the-left' system has been maintained. However, an increased number of 'seat-on-the-right' vehicles are being imported via a variety of routes from foreign countries, especially from Japan. According to the data from July 2004, 1,343 cargo vehicles and 593 passenger vehicles (for diplomats, etc.) were currently being driven on domestic road. As these 'seat-on-the-right' vehicles are not compatible with the domestic transportation system of driving on the right side of the road, there is a high risk of accidents. Experiments show that such system-driver mismatch causes longer operation time for directional signals, higher error frequency in yielding due to additional mental adjustments for 'seat-on-the-right' vehicle drivers. These are, therefore, influential factors which can lead to possible accidents. Furthermore, when the experiments test the visual range during overtaking maneuvers, the visual range of the drivers in the 'seat-on-the-left' vehicle was 2.95 meters as opposed to 1.7 meters for the drivers in the 'seat-on-the-right' vehicle. (In the experiment, the drivers were instructed to look at the paper cup 10 meters away from the back of drivers' seat.) The results demonstrate that it is necessary to have additional safety measures be implemented for the 'seat-on-the-right' vehicles.

Evaluation and Intercomparisons of the Estimated TOVS Precipitable Waters for the Tropical Plume (Tropical Plume 에 대한 TOVS 추정 가강수량의 평가와 상호비교)

  • 정효상;신동인
    • Korean Journal of Remote Sensing
    • /
    • v.9 no.2
    • /
    • pp.51-69
    • /
    • 1993
  • Precipitable Water(PW) are retrieved over the tropical and subtropical Pacific Ocean from TOVS infrared and microwave channel brightness temperature and OLR observations by means of stepwise linear regression. The retrieved TOVS PW fields generated by PW$_{sfc}$(71.1 % of the variance and 0.62 g cm$^{-2}$ standard error over the surface) and PW$_{700500}$(71.7 % and 0.17 g cm$^{-2}$ over the 700 - 500 hPa layer) revealed more evolving synoptic signals over the tropical and subtropical Pacific Ocean. The PW$_{sfc}$ dose not show significantly the TP feature because of the representation of the lower PW for high-level clouds not associated with deep convection. There exists some elusion to trace the TP on the PW$_{sfc}$ field if any supplementary information does not provide. But ECMWF analysis has a general tendency of drying the subtropics and moistening the ITCZ (InterTropical Convergence Zone) and SPCZ(South Pacific Convergence Zone). However, although ECMWF analysis is fairly successful in capturing mean patterms, it is unsuccessful in following active synoptic signal like a tropical plume. Similarly, SMMR-PW does not represent the TP well which consists of the highand middle-level clouds, but PW$_{sfc}$ shows underestimated moistness of TP and does not depict significant signal of TP. In the PW field derived from microwave observations, the TP can not be recognized well. Furthermore, the signature of PW$_{sfc}$ was different from OLR for the TP, which implies the presence of high- and middle-layer thin clouds, but in a closer agreement for deep and active convection areas which contain thick middle- and lower-layer clouds; though OLR represented the cloudiness in the tropics well. In synoptically active regions, it differed from OLR analysis, primarily bacause of actual differences in water vapor and cloud features. The signature of PW$_{sfc}$ was different from OLR for the TP.

An Analysis on Export Behavior to China of Container Port (국내 컨테이너항만의 대중국 수출행태 분석)

  • Son, Yong-Jung
    • Journal of Korea Port Economic Association
    • /
    • v.25 no.2
    • /
    • pp.115-128
    • /
    • 2009
  • This study aims to identify the influence of exchange rate and national economy on Export through container ports (Busan Port, Incheon Port, Gwangyang Port, and Pyeongtaek Port) from January 2001 to October 2007. This study carried a unit root test on the results of the analysis and failed to reject the null hypothesis that level variables have a unit root at the level of 1%. However, it carried out a unit root test on the variables by the first order difference and succeeded in rejecting the null hypothesis aforementioned at the level of 1%. As a result of the cointegration test, it was found that the model is stable. When this study carried out a variance decomposition on the prediction error of export at container various container ports, it found 89% for Busan Port, 83% for Incheon Port, 86% for Gwangyang Port, and 84% for Pyeongtaek Port. These figures indicate that such variables significantly account for export at container ports. For Busan Port, Step 2 of exchange rate showed negative (-) effect, and Step 3 shows an extreme transition into a positive (+) effect. The national economy showed an extreme change from Steps 2 to Step 7, and then a positive effect has been maintained. The Incheon Port, Gwangyang Port and Pyeongtaek Port showed similar trends to Busan Port. From Step 7, it seems that they have Shifted to more stable trends.

  • PDF

The Inter-correlation Analysis between Oil Prices and Dry Bulk Freight Rates (유가와 벌크선 운임의 상관관계 분석에 관한 연구)

  • Ahn, Byoung-Churl;Lee, Kee-Hwan;Kim, Myoung-Hee
    • Journal of Navigation and Port Research
    • /
    • v.46 no.3
    • /
    • pp.289-296
    • /
    • 2022
  • The purpose of this study was to investigate the inter-correlation between crude oil prices and Dry Bulk Freight rates. Eco-friendly shipping fuels has being actively developed to reduce carbon emission. However, carbon neutrality will take longer than anticipated in terms of the present development process. Because of OVID-19 and the Russian invasion of Ukraine, crude oil price fluctuation has been exacerbated. So we must examine the impact on Dry Bulk Freight rates the oil prices have had, because oil prices play a major role in shipping fuels. By using the VAR (Vector Autoregressive) model with monthly data of crude oil prices (Brent, Dubai and WTI) and Dry Bulk Freight rates (BDI, BCI and (BP I) 2008.10~2022.02, the empirical analysis documents that the oil prices have an impact on Dry bulk Freight rates. From the analysis of the forecast error variance decomposition, WTI has the largest explanatory relationship with the BDI and Dubai ranks seoond, Brent ranks third. In conclusion, WTI and Dubai have the largest impact on the BDI, while there are some differences according to the ship-type.

Comparisons between Micro-Kjeldahl and Near Infrared Reflectance Spectroscopy for Protein Content Analysis of Malting Barley Grain (근적외분광분석법과 Micro-Kjeldahl 법 간의 맥주보리 종실의 단백질함량 분석 비교)

  • Kim, Byung-Joo;Suh, Duck-Yong;Suh, Hyung-Soo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.39 no.5
    • /
    • pp.489-494
    • /
    • 1994
  • Near Infrared Reflectance Spectroscopy(NIRS) has been used as a tool for the rapid, accurate, protein assay of malting barley. NIRS used in this study was filter type instruments, Neotec 102. The objective of this study was to obtain the best calibration equation, for the rapid, ease and accurate protein content analysis of malting barley using NIRS system. The optimum wavelength for protein content analysis used NIRS were 2095nm, 2095/1941nm, 2095/1941/2282nm, 2905/1941/2282/2086nm, respectively. Mean protein content with this calibration equation in NIRS analysis was 10.59%, while 10.60% in Micro-Kjeldahl one. The range of protein content in Micro-Kjeldahl was 8.66~12.66% and that in NIRS was 8.80~12.35%. When 18 other varieties produced in 1992 were analysed with 2095nm, 2095/1941nm, 2095/1941/2282nm, 2095/1941/2282/2086nm equation, standard deviation of difference (SDD)and standard error of performence(SEP) and $R^2$ values were 0.47, 0.43, 0.95, respectively. Both the mean protein content by Micro-Kjeldahl and by NIRS was 10.25%. With this equation, analysied 31 varities produced in 1993, SDD and SEP and r values were 0.69, 0.67, 0.91, respectively, and that bias value was 0.65. In this analysis, mean protein content by Micro-Kjeldahl was 10.17% and by NIRS was 10.81%. The range of protein content in Micro-Kjeldahl was 7.58~14.29%, What that in NIRS was 8.63~13.93%. After adjusted bias in the best calibration equation, mean protein content of Micro-Kjeldahl was 10.17% and that of NIRS was 10.09%, without variance of SDD, SEP and r values.

  • PDF

Genetic parameters of milk and lactation curve traits of dairy cattle from research farms in Thailand

  • Pangmao, Santi;Thomson, Peter C.;Khatkar, Mehar S.
    • Animal Bioscience
    • /
    • v.35 no.10
    • /
    • pp.1499-1511
    • /
    • 2022
  • Objective: This study was aimed to estimate the genetic parameters, including genetic and phenotypic correlations, of milk yield, lactation curve traits and milk composition of Thai dairy cattle from three government research farms. Methods: The data of 25,789 test-day milk yield and milk composition records of 1,468 cattle from lactation 1 to 3 of Holstein Friesian (HF) and crossbred HF dairy cattle calved between 1990 and 2015 from three government research farms in Thailand were analysed. 305-day milk yield was estimated by the Wood model and a test interval method. The Wood model was used for estimating cumulative 305-day milk yield, peak milk yield, days to peak milk yield and persistency. Genetic parameters were estimated using linear mixed models with herd, breed group, year and season of calving as fixed effects, and animals linked to a pedigree as random effects, together with a residual error. Univariate models were used to estimate variance components, heritability, estimated breeding values (EBVs) and repeatability of each trait, while pairwise bivariate models were used to estimate covariance components and correlations between traits in the same lactation and in the same trait across lactations. Results: The heritability of 305-day milk yield, peak milk yield and protein percentage have moderate to high estimates ranging from 0.19 to 0.45 while days to peak milk yield, persistency and fat percentage have low heritability ranging from 0.08 to 0.14 in lactation 1 cows. Further, heritability of most traits considered was higher in lactation 1 compared with lactations 2 and 3. For cows in lactation 1, high genetic correlations were found between 305-day milk yield and peak milk yield (0.86±0.07) and days to peak milk yield and persistency (0.99±0.02) while estimates of genetic correlations between the remaining traits were imprecise due to the high standard errors. The genetic correlations within the traits across lactation were high. There was no consistent trend of EBVs for most traits in the first lactation over the study period. Conclusion: Both the Wood model and test interval method can be used for milk yield estimates in these herds. However, the Wood model has advantages over the test interval method as it can be fitted using fewer test-day records and the estimated model parameters can be used to derive estimates of other lactation curve parameters. Milk yield, peak milk yield and protein percentage can be improved by a selection and mating program while days to peak milk yield, persistency and fat percentage can be improved by including into a selection index.

A simulation study for various propensity score weighting methods in clinical problematic situations (임상에서 발생할 수 있는 문제 상황에서의 성향 점수 가중치 방법에 대한 비교 모의실험 연구)

  • Siseong Jeong;Eun Jeong Min
    • The Korean Journal of Applied Statistics
    • /
    • v.36 no.5
    • /
    • pp.381-397
    • /
    • 2023
  • The most representative design used in clinical trials is randomization, which is used to accurately estimate the treatment effect. However, comparison between the treatment group and the control group in an observational study without randomization is biased due to various unadjusted differences, such as characteristics between patients. Propensity score weighting is a widely used method to address these problems and to minimize bias by adjusting those confounding and assess treatment effects. Inverse probability weighting, the most popular method, assigns weights that are proportional to the inverse of the conditional probability of receiving a specific treatment assignment, given observed covariates. However, this method is often suffered by extreme propensity scores, resulting in biased estimates and excessive variance. Several alternative methods including trimming, overlap weights, and matching weights have been proposed to mitigate these issues. In this paper, we conduct a simulation study to compare performance of various propensity score weighting methods under diverse situation, such as limited overlap, misspecified propensity score, and treatment contrary to prediction. From the simulation results overlap weights and matching weights consistently outperform inverse probability weighting and trimming in terms of bias, root mean squared error and coverage probability.

RELIABILITY OF SPIRAL TOMOGRAPHY FOR IMPLANT SITE MEASUREMENT OF THE MANDIBLE (하악골 매식 부위 계측을 위한 나선형 단층촬영술의 신뢰도)

  • Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.27-47
    • /
    • 1997
  • The purpose of this study was to evaluate the accuracy and usefulness of spiral tomography through the comparison and analysis of SCANORA cross-sectional tomographs and DentaScan computed tomographic images of dry mandibles taken by a SCANORA spiral tomographic machine and a computed tomographic machine. Thirty-one dry mandibles with full or partial edentulous areas were used. To evaluate the possible effect of location in the edentulous area, it was divided into 4 regions of Me (region of mental foramen), MI (the midportion between Me and M2), M2 (the midportion between mental foramen and mandibular foramen) and S (the midportion of the mandibular symphysis). A ZPC column (sized 4 mm x 5 mm) was seated on the edentulous regions of Me, MI, M2 and S using the acrylic stent. Then SCANORA spiral tomography and computed tomography were taken on the edentulous regions which contained the ZPC column. The ZPC columns and cross-sectional images of the mandible were measured in the radiographs by three observers and the differences between the two imaging modalities were analysed. The results were as follows: 1. In comparing the actual measurements of the ZPC column and measurements in the radiographs, the mean error of the DentaScan computed tomography was 0.07 mm in vertical direction and -0.06 mm in horiwntal direction, while the mean error of the SCANORA spiral tomography was 0.06 mm in vertical direction and -0.12 mm in horizontal direction. There was a significant difference between the two radiographic techniques in the horizontal measurement of the ZPC column of the symphysis region (p<0.05). But there was no significant difference in the measurements of other regions (p>0.05). 2. In measurements of the distance from the alveolar crest to the inferior border of the mandible (H), and of the distance from the alveolar crest to the superior border of the mandibular canal (Y), there was no significant difference between the two radiographic techniques (p>0.05). 3. In measurements of the distance from the lingual border of the mandible to the buccal border of the mandible (W), and of the distance from the lingual border of the mandible to the lingual border of the mandibular canal (X), there was a significant difference between the two radiographic techniques in measurements of the midportion between the mental foramen and the mandibular foramen (M2) (p<0.05). But there were no significant differences in measurements of the other regions of symphysis (S), mental foramen (Me), the first one-fourth portion between the mental foramen and the mandibular foramen (M1) (p>0.05). 4. Considering the mean range of measurements between observers, the measurements of SCANORA spiral tomography showed higher value than those of DentaScan computed tomography, except in measurements of symphysis (S). 5. On the detectability of the mandibular canal, there was no significant difference between the two radiographic techniques (p>0.05). In conclusion, SCANORA spiral tomography demonstrated a higher interobserver variance than that of DentaScan computed tomography for implant site measurements in the posterior edentulous area of the mandible. These differences were mainly the result of difficulty in the detection of the border of the mandible in SCANORA spiral tomography. But considering the cost and the radiation exposure, SCANORA spiral tomography can be said to be a relatively good radiographic technique for implant site measurement.

  • PDF