• Title/Summary/Keyword: Error Control

Search Result 6,594, Processing Time 0.039 seconds

Improvement of the Result Related to Tumor Marker Test Through the OCS QC Program (OCS QC 프로그램을 통한 건진 센터 종양검사의 결과보고 개선)

  • Back, Song-Ran;Kim, Sung-Ho;Yoo, So-Yeon;Kim, Nyun-Ok;Moon, Hyoung-Ho;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.185-188
    • /
    • 2009
  • Purpose: Standard of retests were discrepant and inconsistent due to inaccuracy and lack of standardization within normal range limit of tumor marker test. To enhance the standardization of retests set standard value below normal range and the Order Communication System Quality Control (OCS QC) program was put in place. This program enables managing the results within lower limit of normal range which were used for tumor marker test in Health Center. Materials and Methods: At present the tumor marker study for AFP, CEA, CA19-9, CA125, and PSA included outpatients in Asan Medical Center from February to March, 2009. The standard value was obtained by using the percentage of CV of Inter Assay according to the normal range of each tumor test. The results were confirmed by using the OCS QC program via formatted assessment of screening test such as test items, standard value and medical department. The number of out-of-range results within plus and minus 30 percents regarding the five primary items of tumor marker test was assessed. The next step was to obtain the number of AFP, CEA, and CA125 according to the ratio of comparison between prior and post test result, 60%, 50%, and 40% within normal range, respectively. In addition, set standard value below normal range. Results: The first screening test with percentage of sample number was resulted between 30%-40% and the second one was AFP 26.1%, CEA 18.9%, CA19-9 17.3%, CA125 18.7%, and PSA 21.0% obtained screening percentage of average 20 percents. The limited value of retest was AFP less than 5.0 and more than 10.0, CEA less than 1.0 and more than 3.0, CA19-9 less than 10.0 and more than 30.0, and PSA less than 1.0 and more than 2.0 to set and the number of retest was obtained by applying to the limited value of retest to screening percentage of average 20 percents For two months, the number of retest was AFP 0, CEA 15, CA19-9 3, CA125 2, and PSA 5. Conclusions: Through using the OCS QC program in establishing the standard of retest systemically, there appeared to be reduced discrepancy among the examiners and to be expected improvement in relation to the error of results.

  • PDF

Effect of Night and Daytime Temperatures on Growth and Yield of Paprika 'Fiesta' and 'Jubilee' (${\cdot}$야 온도가 착색단고추의 생육 및 수량에 미치는 영향)

  • Choi Young Hah;Kwon Joon Kook;Lee Jae Han;Kang Nam Jun;Cho Myeong Whan;Kang Jum Soon
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.226-232
    • /
    • 2004
  • This experiment was conducted to investigate the effect of night and daytime temperatures on growth and yield of paprika 'Fiesta' and 'Jubilee' under soil culture experiment in the vinyl houses during the 2003 and 2004 season. Total fruit yield was greater in 'Fiesta' than 'Jubilee' Marketable yield was not different between two cultivars, due to lower $\%$ marketable fruits in 'Fiesta'. mean Fruit weight was not different between two cultivars. Difference of yield between cultivars was due to fruit number, harves time and root condition. It was caused by cracked fruits to decrease $\%$ marketable fruits. Total yield was greater in nighttime temperature of $18^{\circ}C\;than\;15^{\circ}C$ and marketable yield was considerably greater because of $\%$ marketable fruits was higher. Mean fruit weight was slightly greater in nighttime temperature of $15^{\circ}C\;than\;18^{\circ}C$. Difference of fruit yield in treatments of nighttime temperature was due to fruit number and harvest time. There was not significant difference of yield between daytime temperature of $28^{\circ}C\;and\;31^{\circ}C$, but in $34^{\circ}C$, total and marketable yields were the least and mean fruit weight was the smallest because of decreased $CO_2$ concentration in the house, accerated vegetative growth, and the least chlorophyll content. There were no significant difference in photosynthetic rate, transpiration rate, maximal photochemical efficiency and antioxidant enzyme activities of all temperature treatments in this experiment. However it was clear that a little difference in error range of these results affects the source of crops in any case. It was not acknowledged that compensation effect by high temperature in daytime to the low temperature treatment in nighttime.

Design Factor Analysis of End-Effector for Oriental Melon Harvesting Robot in Greenhouse Cultivation (시설재배 참외 수확 로봇용 엔드이펙터의 설계 요인 분석)

  • Ha, Yu Shin;Kim, Tae Wook
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.284-290
    • /
    • 2013
  • This study analyzed the geometric, compressive, cutting and friction properties of oriental melons in order to design a gripper capable of soft handling and a cutter for cutting oriental melon vine among the end effector of oriental melon as a preliminary step for developing the end effector of the robot capable of harvesting oriental melons in protected cultivation. As a result, the average length, diameter at the midpoint, weight, volume and roundness of the oriental melons were 108 mm, 70 mm, 188 g, 333 mL and 3.8 mm. Nonlinear regression analysis was performed on the equation $W=L^a{\times}D_2^b$ with variation of the length (L) and diameter (D2) of the weight (W) of the oriental melons. As a result, it was shown that there was a correlation between a of 2.0279 and b of -0.9998 as a constant value. The average diameter of the oriental melon vine was 3.8 mm, and most vines were distributed within a radius of 5 mm from the center. The average yield value, compressive strength and hardness of the oriental melons were $36.5N/cm^2$, $185.7N/cm^2$ and $636.7N/cm^2$, respectively. The average cutting force and shear strength of the oriental melon vines were $2.87{\times}10^{-2}\;N$ and $5.60N/cm^2$, respectively. The maximum friction coefficient of the oriental melons was rubber of 0.609, followed by aluminium of 0.393, stainless steel of 0.177 and teflon of 0.079. It was considered possible to apply it to the size of the gripper and cutter, turning radius, dynamics of drive motor and selection of materials and their quality in light of the position error and safety factor according to the movement when designing end effector based on the analyzed data.

Comparison of Radioactivity Measurement with Radionuclide Calibrators in Nuclear Medicine Centers (의료용 방사능측정기의 측정 정확도 평가)

  • Son, Hye-Kyung;Kim, Ji-Hye;Lim, Chun-Il;Yang, Hyun-Kyu;Park, Ki-Jung;Oh, Heon-Jin;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.16-21
    • /
    • 2010
  • To acquire good image quality and to minimize unnecessary radiation dose to patients, it is important to ensure that the radiopharmaceutical administered is accurately measured. Quality control of radionuclide calibrators should be performed to achieve these goals. The purpose of this study is to support the quality control of radionuclide calibrators in nuclear medicine centers and to investigate the level of measurement accuracy of the radionuclide calibrators. 58 radionuclide calibrators from 45 nuclear medicine centers, 74 radionuclide calibrators from 58 nuclear medicine centers, and 60 radionuclide calibrators from 45 nuclear medicine centers were tested with I-131, Tc-99m and I-123, respectively. The results showed that 81% of calibrators for I-131, 61% of calibrators for Tc-99m and 67% of calibrators for I-123 were within ${\pm}5%$. 17% of calibrators for I-131, 20% of calibrators for Tc-99m and 15% of calibrators for I-123 had a deviation in the range 5%< $|{\Delta}|{\leq}10%$. 2% of calibrators for I-131, 19% of calibrators for Tc-99m and 18% of calibrators for I-123 had a deviation of $|{\Delta}|$ >10%. Follow-up measurements were performed on the calibrators whose error exceeded the ${\pm}10%$ limit. As a result, some of the calibrator showed an improvement and their deviation decreased below the ${\pm}10%$ limit. The results have shown that such comparisons are necessary to improve the accuracy of the measurement and to identify malfunctioning radionuclide calibrators.

Review on Usefulness of EPID (Electronic Portal Imaging Device) (EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰)

  • Lee, Choong Won;Park, Do Keun;Choi, A Hyun;Ahn, Jong Ho;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.57-67
    • /
    • 2013
  • Purpose: Replacing the film which used to be used for checking the set-up of the patient and dosimetry during radiation therapy, more and more EPID equipped devices are in use at present. Accordingly, this article tried to evaluated the accuracy of the position check-up and the usefulness of dosimetry during the use of an electronic portal imaging device. Materials and Methods: On 50 materials acquired with the search of Korea Society Radiotherapeutic Technology, The Korean Society for Radiation Oncology, and Pubmed using "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", and "In vivo dosimetry" as indexes, the usefulness of EPID was analyzed by classifying them as history of EPID and dosimetry, set-up verification and characteristics of EPID. Results: EPID is developed from the first generation of Liquid-filled ionization chamber, through the second generation of Camera-based fluoroscopy, and to the third generation of Amorphous-silicon EPID imaging modes can be divided into EPID mode, Cine mode and Integrated mode. When evaluating absolute dose accuracy of films and EPID, it was found that EPID showed within 1% and EDR2 film showed within 3% errors. It was confirmed that EPID is better in error measurement accuracy than film. When gamma analyzing the dose distribution of the base exposure plane which was calculated from therapy planning system, and planes calculated by EDR2 film and EPID, both film and EPID showed less than 2% of pixels which exceeded 1 at gamma values (r%>1) with in the thresholds such as 3%/3 mm and 2%/2 mm respectively. For the time needed for full course QA in IMRT to compare loads, EDR2 film recorded approximately 110 minutes, and EPID recorded approximately 55 minutes. Conclusion: EPID could easily replace conventional complicated and troublesome film and ionization chamber which used to be used for dosimetry and set-up verification, and it was proved to be very efficient and accurate dosimetry device in quality assurance of IMRT (intensity modulated radiation therapy). As cine mode imaging using EPID allows locating tumors in real-time without additional dose in lung and liver which are mobile according to movements of diaphragm and in rectal cancer patients who have unstable position, it may help to implement the most optimal radiotherapy for patients.

  • PDF

Analysis of Growth Response by Non - destructive, Continuous Measurement of Fresh Weight in Leaf Lettuce 1. Effect of Nutrient Solution and Light Condition on the Growth of Leaf Lettuce (비파괴 연속 생체중 측정장치의 개발 및 이에 의한 상추의 생장반응 분석 l. 양액의 이온 농도 및 명ㆍ암 처리가 생장에 미치는 영향)

  • 남윤일;채제천
    • Journal of Bio-Environment Control
    • /
    • v.4 no.1
    • /
    • pp.50-58
    • /
    • 1995
  • These studies were carried out to develop a system for non -destructive and continuous measurement of fresh weight and to analyse the growth response of leaf lettuce under the different nutrient solution and light condition with this system. The developed measurement system was consisted of four load cells and a microcomputer. The output from the system was highly positive correlation with the plant fresh weight above the surface of the hydroponic solution. The top fresh weight of plant could be measured within the error $\pm$ 1.0g in the range of 0 - 2000g. The top fresh weight of leaf lettuce increased 44 times at 18th day after transferring to the nutrient solution, and the maximum growth rate was observed at 13th day after transferring. The growth rate was 10.7- 29.6% per day during 18 days. Optimum concentration of the nutrient solution for the growth of lettuce was 1.4 - 2.2 mS/cm of EC level. When the light condition was changed from dark to light, the fresh weight was temporarily decreased, but the fresh weight increased under the opposite condition. Top fresh weight of leaf lettuce in the darkness normally increased within 12 hours after darkness treatment, and then slowly increased until 78 hours under continuous dark condition. After that times, the fresh weight began to decrease.

  • PDF

Beam Shaping by Independent Jaw Closure in Steveotactic Radiotherapy (정위방사선치료 시 독립턱 부분폐쇄를 이용하는 선량분포개선 방법)

  • Ahn Yong Chan;Cho Byung Chul;Choi Dong Rock;Kim Dae Yong;Huh Seung Jae;Oh Do Hoon;Bae Hoonsik;Yeo In Hwan;Ko Young Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.150-156
    • /
    • 2000
  • Purpose : Stereotactic radiation therapy (SRT) can deliver highly focused radiation to a small and spherical target lesion with very high degree of mechanical accuracy. For non-spherical and large lesions, however, inclusion of the neighboring normal structures within the high dose radiation volume is inevitable in SRT This is to report the beam shaping using the partial closure of the independent jaw in SRT and the verification of dose calculation and the dose display using a home-made soft ware. Materials and Methods : Authors adopted the idea to partially close one or more independent collimator jaw(5) in addition to the circular collimator cones to shield the neighboring normal structures while keeping the target lesion within the radiation beam field at all angles along the arc trajectory. The output factors (OF's) and the tissue-maximum ratios (TMR's) were measured using the micro ion chamber in the water phantom dosimetry system, and were compared with the theoretical calculations. A film dosimetry procedure was peformed to obtain the depth dose profiles at 5 cm, and they were also compared with the theoretical calculations, where the radiation dose would depend on the actual area of irradiation. Authors incorporated this algorithm into the home-made SRT software for the isodose calculation and display, and was tried on an example case with single brain metastasis. The dose-volume histograms (DVH's) of the planning target volume (PTV) and the normal brain derived by the control plan were reciprocally compared with those derived by the plan using the same arc arrangement plus the independent collimator jaw closure. Results : When using 5.0 cm diameter collimator, the measurements of the OF's and the TMR's with one independent jaw set at 30 mm (unblocked), 15.5 mm, 8.6 mm, and 0 mm from th central beam axis showed good correlation to the theoretical calculation within 0.5% and 0.3% error range. The dose profiles at 5 cm depth obtained by the film dosimetry also showed very good correlation to the theoretical calculations. The isodose profiles obtained on the home-made software demonstrated a slightly more conformal dose distribution around the target lesion by using the independent jaw closure, where the DVH's of the PTV were almost equivalent on the two plans, while the DVH's for the normal brain showed that less volume of the normal brain receiving high radiation dose by using this modification than the control plan employing the circular collimator cone only. Conclusions : With the beam shaping modification using the independent jaw closure, authors have realized wider clinical application of SRT with more conformal dose planning. Authors believe that SRT, with beam shaping ideas and efforts, should no longer be limited to the small spherical lesions, but be more widely applied to rather irregularly shaped tumors in the intracranial and the head and neck regions.

  • PDF

Strategies about Optimal Measurement Matrix of Environment Factors Inside Plastic Greenhouse (플라스틱온실 내부 환경 인자 다중센서 설치 위치 최적화 전략)

  • Lee, JungKyu;Kang, DongHyun;Oh, SangHoon;Lee, DongHoon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.161-170
    • /
    • 2020
  • There is systematic spatial variations in environmental properties due to sensitive reaction to external conditions at plastic greenhouse occupied 99.2% of domestic agricultural facilities. In order to construct 3 dimensional distribution of temperature, relative humidity, CO2 and illuminance, measurement matrix as 3 by 3 by 5 in direction of width, height and length, respectively, dividing indoor space of greenhouse was designed and tested at experimental site. Linear regression analysis was conducted to evaluate optimal estimation method in terms with horizontal and vertical variations. Even though sole measurement point for temperature and relative humidity could be feasible to assess indoor condition, multiple measurement matrix is inevitably required to improve spatial precision at certain time domain such as period of sunrise and sunset. In case with CO2, multiple measurement matrix could not successfully improve the spatial predictability during a whole experimental period. In case with illuminance, prediction performance was getting smaller after a time period of sunrise due to systematic interference such as indoor structure. Thus, multiple sensing methodology was proposed in direction of length at higher height than growing bed, which could compensate estimation error in spatial domain. Appropriate measurement matrix could be constructed considering the transition of stability in indoor environmental properties due to external variations. As a result, optimal measurement matrix should be carefully designed considering flexibility of construction relevant with the type of property, indoor structure, the purpose of crop and the period of growth. For an instance, partial cooling and heating system to save a consumption of energy supplement could be successfully accomplished by the deployment of multiple measurement matrix.

A Proposal to Control System and the Problems of the Problems of the Report about Supply and Demand for Medical Technicians and Management Policy ("의료기사인력수급에 관한 보고서"의 문제점과 관리제도의 개선방안)

  • Kim, Sang-Hyun;Lim, Yongmoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.25-30
    • /
    • 2008
  • Purpose: In this paper, we have analyzed the problems of the Oh's report which is used to the basic data for supply and demand of medical technicians and studied a proposal for improvement to control system and supply and demand of korean optometrists. Methods: We have analyzed errors of Oh's report including supply and demand for medical technicians and management policy, expecting number for future optician, inaccurate estimation by limited data (employment rate, retirement rate, mortality rate) and an incorrect method of measurement for future supply and demand. Results: Oh's report showed the 18% error for estimation of supply which exclude the irregular entrance students. The estimation of supply was calculated by graduation rate 62.6% (college and University of Technology are 78.9% and 85.98% respectively), employment rate 65.8% (the average employment between 2002 and 2007 is 73.96%) and retirement rate is 2.3% (the retirement of pharmacists is 1.3%) but it showed the significant differences to objective data. For estimate the suitable ratio of optometrists to the population, the ratio use of medical facilities by an age group was used, and suggested spectacle wearers 1,280 persons (populations 2,928 persons) per optometrist but the different from reference of Germany (4,706 persons), America (1,789 persons) and Korea (1,825 persons/an optometrist) are applied to estimation on supply. This report applied the low employment rate and argued that maintain the present situation, but claimed that utilize unemployment persons. The above result has induced double weighting effect on estimation of supply. Conclusions: To solve the related problems of supply and demand, we have to make a search for exact data and optimum application model, have to take an example of nation similar job category as Germany and the research result of the job satisfaction into consideration. After we get the integrated research result, we must carried out the policy with fairness and balance for the estimation of supply and demand. Therefore exact research is required prior to beginning policy establishment, government and related group have to make a clear long-term plan and permanent organization for medical technician to establish supply and demand of medical technician.

  • PDF

Legislative Study on the Mitigation of the Burden of Proof in Hospital Infection Cases - Focusing on the revised Bürgerliches Gesetzbuch - (병원감염 사건에서 증명책임 완화에 관한 입법적 고찰 - 개정 독일민법을 중심으로 -)

  • Yoo, Hyun Jung
    • The Korean Society of Law and Medicine
    • /
    • v.16 no.2
    • /
    • pp.159-193
    • /
    • 2015
  • Owing to causes such as population aging, increased use of various medical devices, long-term hospitalization of various patients with reduced immune function such as cancer, diabetes, and organ transplant patients, and the growing size of hospitals, hospital infections are continuing to increase. As seen in the MERS crisis of 2015, hospital infections have become a social and national problem. In order to prevent damage due to such hospital infections, it is necessary to first strictly implement measures to prevent hospital infections, while, on the other hand, providing proper relief of damage suffered due to hospital infections. However, the mainstream attitude of judicial precedents relating to hospital infection cases has been judged to in fact shift responsibility over damages due to hospital infections on the patient. In light of the philosophy of the damage compensation system, whose guiding principle if the fair and proper apportionment of damages, there is a need to seek means of drastically relaxing the burden of proof on the patient's side relative to conventional legal principles for relaxing the burden of proof, or the theory of de facto estimation. In relation to such need, the German civil code (Burgerliches Gesetzbuch), which defines contracts of medical treatment as typical contracts under the civil code, and has presumption of negligence provisions stipulating that, in cases such as hospital infections which were completely under the control of the medical care providers, if risks in general medical treatment have been realized which cause violations of the life, body, or health of patients, error on the part of the person providing medical care is presumed, was examined. Contracts of medical treatment are entered into very frequently and broadly in the everyday lives of the general public, with various disputes owing thereto arising. Therefore, it is necessary to, by defining contracts of medical treatment as typical contracts under the civil code, regulate the content of said contracts, as well as the proof of burden when disputes arise. If stipulations in the civil code are premature as of yet, an option may be to regulate through a special act, as is the case with France. In the case of hospital infection cases, it is thought that 'legal presumption of negligence' relating to 'negligence in the occurrence of hospital infections,' which will create a state close to equality of arms, will aid the resolution of the realistic issue of the de facto impossibility of remedying damages occurring due to negligence in the process of occurrence of hospital infections. Also, even if negligence is presumed by law, as the patient side is burdened with proving the causal relationships, such drastic confusion as would occur if the medical care provider side is found fully liable if a hospital infection occurs may be avoided. It is thought that, alongside such efforts, social insurance policy must be improved so as to cover the expenses of medical institutions having strictly implemented efforts to prevent hospital infections in the event that they have suffered damages due to a hospital infection accident, and that close future research and examination into this matter will be required.

  • PDF