• Title/Summary/Keyword: Erosion control line

Search Result 14, Processing Time 0.024 seconds

Erosion Control Line (ECL) Establishment Using Coastal Erosion Width Prediction Model by High Wave Height (고파랑 해안 침식폭 예측모델을 이용한 침식한계선(ECL) 설정)

  • Park, Seung-Min;Park, Seol-Hwa;Lee, Jung-Lyul;Kim, Tae-Kon
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.526-534
    • /
    • 2019
  • The average coastline and the erosion control line introduced as the management coastline, and the average shoreline (MSL) was established from the observed coastline. Also, the median grain size and the wave height of 30-years return period were applied. The erosion control line (ECL) was established through the model, HaeSaBeeN. These two lines set the coastline for evaluation. Based on the observed monitoring data along the coastline, the 1-day variation according to the normal distribution was used to estimate the regional variation, and the width of the erosion was calculated by applying the median grain size (D50) and the wave height of 30-years return period through the high-wave coastal erosion width model, i.e., HaeSaBeeN.

Cause Analysis of Flow Accelerated Corrosion and Erosion-Corrosion Cases in Korea Nuclear Power Plants

  • Lee, Y.S.;Lee, S.H.;Hwang, K.M.
    • Corrosion Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.182-188
    • /
    • 2016
  • Significant piping wall thinning caused by Flow-Accelerated Corrosion (FAC) and Erosion-Corrosion (EC) continues to occur, even after the Mihama Power Station unit 3 secondary pipe rupture in 2004, in which workers were seriously injured or died. Nuclear power plants in many countries have experienced FAC and EC-related cases in steam cycle piping systems. Korea has also experienced piping wall thinning cases including thinning in the downstream straight pipe of a check valve in a feedwater pump line, the downstream elbow of a control valve in a feedwater flow control line, and failure of the straight pipe downstream of an orifice in an auxiliary steam return line. Cause analyses were performed by reviewing thickness data using Ultrasonic Techniques (UT) and, Scanning Electron Microscope (SEM) images for the failed pipe, and numerical simulation results for FAC and EC cases in Korea Nuclear Power Plants. It was concluded that the main cause of wall thinning for the downstream pipe of a check valve is FAC caused by water vortex flow due to the internal flow shape of a check valve, the main cause of wall thinning for the downstream elbow of a control valve is FAC caused by a thickness difference with the upstream pipe, and the main cause of wall thinning for the downstream pipe of an orifice is FAC and EC caused by liquid droplets and vortex flow. In order to investigate more cases, additional analyses were performed with the review of a lot of thickness data for inspected pipes. The results showed that pipe wall thinning was also affected by the operating condition of upstream equipment. Management of FAC and EC based on these cases will focus on the downstream piping of abnormal or unusual operated equipment.

Cause Analysis for the Wall Thinning and Leakage of a Small Bore Piping Downstream of an Orifice (주증기계통 오리피스 후단 소구경 배관의 감육 및 누설 발생)

  • Hwang, Kyeong Mo
    • Corrosion Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.227-232
    • /
    • 2013
  • A number of components installed in the secondary system of nuclear power plants are exposed to aging mechanisms such as FAC (Flow-Accelerated Corrosion), Cavitation, Flashing, and LDIE (Liquid Droplet Impingement Erosion). Those aging mechanisms can lead to thinning of the components. In April 2013, one (1) inch small bore piping branched from the main steam line experienced leakage resulting from wall thinning in a 1,000 MWe Korean PWR nuclear power plant. During the normal operation, extracted steam from the main steam line goes to condenser through the small bore piping. The leak occurred in the downstream of an orifice. A control valve with vertical flow path was placed on in front of the orifice. This paper deals with UT (Ultrasonic Test) thickness data, SEM images, and numerical simulation results in order to analyze the extent of damage and the cause of leakage in the small bore piping. As a result, it is concluded that the main cause of the small bore pipe wall thinning is liquid droplet impingement erosion. Moreover, it is observed that the leak occurred at the reattachment point of the vortex flow in the downstream side of the orifice.

Enhanced Salt Stress Tolerance in Transgenic Potato Plants Expressing IbMYB1, a Sweet Potato Transcription Factor

  • Cheng, Yu-Jie;Kim, Myoung-Duck;Deng, Xi-Ping;Kwak, Sang-Soo;Chen, Wei
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.12
    • /
    • pp.1737-1746
    • /
    • 2013
  • IbMYB1, a transcription factor (TF) for R2R3-type MYB TFs, is a key regulator of anthocyanin biosynthesis during storage of sweet potatoes. Anthocyanins provide important antioxidants of nutritional value to humans, and also protect plants from oxidative stress. This study aimed to increase transgenic potatoes' (Solanum tuberosum cv. LongShu No.3) tolerance to environmental stress and enhance their nutritional value. Transgenic potato plants expressing IbMYB1 genes under the control of an oxidative stress-inducible peroxidase (SWPA2) promoter (referred to as SM plants) were successfully generated through Agrobacterium-mediated transformation. Two representative transgenic SM5 and SM12 lines were evaluated for enhanced tolerance to salinity, UV-B rays, and drought conditions. Following treatment of 100 mM NaCl, seedlings of SM5 and SM12 lines showed less root damage and more shoot growth than control lines expressing only an empty vector. Transgenic potato plants in pots treated with 400 mM NaCl showed high amounts of secondary metabolites, including phenols, anthocyanins, and flavonoids, compared with control plants. After treatment of 400 mM NaCl, transgenic potato plants also showed high DDPH radical scavenging activity and high PS II photochemical efficiency compared with the control line. Furthermore, following treatment of NaCl, UV-B, and drought stress, the expression levels of IbMYB1 and several structural genes in the flavonoid biosynthesis such as CHS, DFR, and ANS in transgenic plants were found to be correlated with plant phenotype. The results suggest that enhanced IbMYB1 expression affects secondary metabolism, which leads to improved tolerance ability in transgenic potatoes.

Topographical Changes in Torrential Stream After Dredging in Erosion Control Dam - Using Terrestrial LiDAR Data - (사방댐 준설이 계류의 지형변화에 미치는 영향 - 지상 LiDAR 자료를 이용하여 -)

  • Seo, Junpyo;Woo, Choongshik;Lee, Changwoo;Kim, Kyongha;Lee, HeonHo
    • Journal of Korean Society of Forest Science
    • /
    • v.103 no.3
    • /
    • pp.392-401
    • /
    • 2014
  • This research was carried out to understand the impact of mountainous torrent on topographical change of slope and sediment volume within a deposit line by dredging of soil erosion control dam. Terrestrial LiDAR surveys were conducted at dredged and non-dredged sites. Terrestrial LiDAR has an advantage on detecting topographical changes easily without demanding workmanship and technical skill for users. The distribution of erodible slope ($20^{\circ}-40^{\circ}$) was higher in non-dredged site than that of dredged site. However, the distribution was higher in dredged site than that of non-dredged site after rainy season. Erosion and deposition appeared regularly in a dredged site, but those occurred irregularly in the non-dredged site. The inflow of soil per square meter was 1.7 times higher in dredged site than that of non-dredged site after rainy season. The difference of rainfall in each site did not affect to soil erosion. The distribution of erodible slope was increased in dredged site than that of non-dredged site after rainy season due to inflow of soil from upper stream caused by dredging.

A study on the relationship between Schmidt Hammer's 'R' and bedrock microforms (기반암 하상 미지형과 슈미트 해머 반발 값과의 관계에 대한 연구)

  • KIM, Jong Yeon
    • Journal of The Geomorphological Association of Korea
    • /
    • v.19 no.3
    • /
    • pp.51-69
    • /
    • 2012
  • Physical strength of the rock is the most important factor of resistance to erosion and has been measured through various way. Bedrock microforms, like potholes and grooves, are the forms sculpted by the erosional processes of flow and the location and morphology are strongly affected by the differential erosion. It also assumed that the physical strength of the rock controls the erosion rate and mode of erosion. The schmidt hammer has been used to measure the rock strength in the field for the geomorphological research. To find the relationship between the rock strength and microforms, Schmidt hammer's R(rebound) were measured in the Baeksuktan, middle reach of Gilancheon, Cheongsong, Gyungsangbuk do. The overall values of rebound of the local sandstone showed over 65 in most cases, so it can be regarded as 'very strong'. It is found that the rebound values of the rock surface decreased towards current water level. It also, however, found that there was no systematic differences in rebound values among the topographically high and lows in the bedrock surface. There was no statistically significant difference in rebound values of the area with well developed microforms and others. The values of R from the exposed faces and inside of the microforms are similar. In the case of conglomerate, the part with the gravel showed higher values that the parts with sands. The rebound values are decreased near of(<1cm) the geological discontinuities(including joint and faults), so this line of weakness could be the point of initiation of active erosion to form microforms. However there is large variations in rebound values within this part. It also should be mentioned that topological relation between the strike of the geologic discontinuities and flow direction looks control the mode of erosional processes.

Environmental Evaluation and Final Reclamation Design for the Friar Tuck Abandonded Coal Mine Site, Southwestern Indiana, U.S.A. (미국 인디아나주 남서부 Friar Tuck 폐탄광에 대한 환경평가 및 최종 복구설계)

  • ;Terry R.West
    • The Journal of Engineering Geology
    • /
    • v.6 no.2
    • /
    • pp.65-81
    • /
    • 1996
  • Friar Tuck, an Abandoned Mine Lands (AML) site, is located on the Greene-Sullivan county line in southwest Indiana. Prior to the on-going reclamation, Friar Tuck was one of the Indiana's largest and most environmentally adverse abandoned mine lands. The direct vegetation method was used to reclaim tailing ponds. Grading, capping, and revegetalon using agricultural limestone, fertilizer, mulch and seed were applied to the gob piles to abate acid mine drainage (AMD) and off-side sedimentaion. Erosion control structures such as terrace, diversion ditch, and gabion structures were also constructed to minimize erosion at slopes. A new method for treatment of AMD using apatite was tested in the laboratory and field. Apatite effectively removed iron, aluminum and sulfate while maintaining an almost constant pH. Apparently, this method can be applied to control AMD from mining refuse materials, even those containing high concentrations of iron and aluminum ions.

  • PDF

Detection of Ridges and Ravines using Fuzzy Logic Operations

  • Kim, Kyoung-Min;Park, Joong-Jo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.5
    • /
    • pp.943-949
    • /
    • 2000
  • In object analysis, line and curve finding plays a universal role. And, it can be accomplished by detecting ridges and ravines in digital gray-scale images. In this paper, we present a new method of detecting ridges and ravines by using local min and max operations. This method uses erosion and dilation properties of these fuzzy logic operations and requires no information of ridge or ravine direction, so that the method is simple and easy in comparison with the conventional analytical methods. The experimental results show that the technique has a strong ability in finding ridges and ravines.

  • PDF

Malfunction Detection of High Voltage Equipment Using Microphone Array and Infrared Thermal Imaging Camera (Microphone Array와 열화상 카메라를 이용한 고압설비 고장검출)

  • Han, Sun-Sin;Choi, Jae-Young;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • The paper proposes a hierarchical fault detection method for the high voltage equipment using a microphone array which detects the location of fault and the thermal imaging and CCD cameras which verifies the fault and stores the image, respectively. There are partial arc discharges on the faulty insulators, which generates a specific pattern of sound. Detecting the signal using the microphone array, the location of the faulty insulator can be estimated. The 6th band-pass filter was applied to remove noise signal from wind or external influence. When the mobile robot carries the thermal and CCD cameras to the possible place of the fault insulator, the fault insulators or power transmission wires can be detected by the thermal images, which are caused by the aging or natural erosion. Finally, the CCD camera captures the image of the fault insulator for the record. The detection scheme of fault location using the microphone array and the thermal images have been proved to be effective through the real experiments. As a result of this research, it becomes possible to use a mobile robot with the integrated sensors to detect the fault insulators instead of a human being.

Optimization of Fugitive Dust Control System for Meteorological Conditions (기상조건별 비산먼지 관리체계 최적화 연구)

  • Kim Hyun-Goo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.573-583
    • /
    • 2005
  • Fugitive dust, which is emitted in the ambient air without first passing through a stack or duct designed to control flow, is frequently generated by means of wind erosion from storage yards at Pohang Steel Wokrs. The size distribution of fugitive dust is mostly in the range of coarse particulate which is deposited as soon as emitted and less harm to human health; however $20\%$ of fugitive dust contains PM 10 known as one of most harmful airborne pollutant. Consequently, effective control and reduction of fugitive dust is strongly requested by the local society, but it is not easy so far because the generation and dispersion of fugitive dust highly depends on meteorological conditions, and it being occurred for irregularity. This research presented a fugitive dust control system for each meteorological condition by providing statistical prediction data obtained from a statistical analysis on the probability of generating the threshold velocity at which the fugitive dust begins to occur, and the frequency occurring by season and by time of the wind direction that can generate atmospheric pollution when the dispersed dust spreads to adjacent residential areas. The research also built a fugitive dust detection system which monitors the weather conditions surrounding storage yards and the changes in air quality on a real-time basis and issues a warning message by identifying a situation where the fugitive dust disperses outside the site boundary line so that appropriate measures can be taken on a timely basis. Furthermore, in respect to the spraying of water to prevent the generation of fugitive dust from the storage piles at the storage yard, an advanced statistical meteorological analysis on the weather conditions in Pohang area and a case study of fugitive dust dispersion toward outside of working field during $2002\∼2003$ were carried out in order to decide an optimal water-spraying time and the number of spraying that can prevent the origin of fugitive dust emission. The results of this research are expected to create extremely significant effects in improving surrounding environment through actual reduction of the fugitive dust produced from the storage yard of Pohang Steel Works by providing a high-tech warning system capable of constantly monitoring the leakage of fugitive dust and water-spray guidance that can maximize the water-spraying effects.