• Title/Summary/Keyword: Ergonomic solution

Search Result 15, Processing Time 0.019 seconds

Ergonomic Optimization of the Handle Height and Distance for the Two-Vertical Type Handles of the 4-Wheel Cart (4륜 운반차 수직형 손잡이에서 인간공학적 최적 높이 및 간격 결정)

  • Song, Young Woong
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.4
    • /
    • pp.123-129
    • /
    • 2013
  • Among various manual materials handling tasks, pushing/pulling was known to be one of the risk factors for the low back and shoulder musculoskeletal disorders (MSDs). This study was conducted to find out an optimal solution set of the handle height and distance for 4-wheel cart with two vertical handles. Ten male college students participated in the pushing force measurement experiment. The face-centered cube design, one of the central composite designs, was applied for the experiment, and the isometric voluntary pushing force was measured in 9 treatment conditions. The second order response surface model was predicted by using the pushing strength as a response variable, and the handle height and distance as independent factors. According to the 2nd order response model, the handle height and distance showed nonlinear relationship with the isometric pushing strength. To maximize the 2nd order response model (pushing force), the handle height and distance were optimized. The optimal handle height was 'xyphoid process height - stature', and the optimal handle distance was '$1.25{\times}shoulder$ width'. When calculated using the anthropometric data of the subjects of this study, the optimal handle height was $115.4{\pm}3.4$ cm, slightly higher than the elbow height, and the handle distance was $52.9{\pm}2.3$ cm.

Analytical Design Methodology for Recommending VDT Workstation Settings and Computer Accessories Layout

  • Rurkhamet, Busagarin;Nanthavanij, Suebsak
    • Industrial Engineering and Management Systems
    • /
    • v.3 no.2
    • /
    • pp.140-150
    • /
    • 2004
  • Repetitive stress injury at the wrist has been reported as a common injury among visual display terminal (VDT) users (i.e., computer users). Adjusting a VDT workstation (computer table and chair) to maintain a correct seated posture while operating a keyboard is perhaps the most frequently recommended preventive solution. This paper proposes an analytical design methodology based on ergonomic design principles for recommending appropriate VDT workstation settings and layout of individual computer accessories on the computer table. The proposed design methodology consists of two interrelated phases: (1) determination of VDT workstation settings, and (2) design of computer accessories layout. Based on the information about the VDT user, dominant task to be performed, typing skill, and degrees of physical and visual interactions between the user and computer accessories, adjustment and layout solutions are recommended to allow having a correct seated posture while minimizing both physical and visual movements. The results from an experiment show that when adjusting the workstation and locating the computer accessories according to the recommendations given by the proposed design methodology, the user's hand movements can be significantly reduced.

Design and Development of an Ergonomic Trolley-Lifter for Sheet Metal Handling Task: A Preliminary Study

  • Radin Umar, Radin Zaid;Ahmad, Nadiah;Halim, Isa;Lee, Poh Yan;Hamid, Malek
    • Safety and Health at Work
    • /
    • v.10 no.3
    • /
    • pp.327-335
    • /
    • 2019
  • Background: There have been some concerns related to manual handling of large items in industry. Manual handling operations of large sheet metal may expose workers to risks related to efficiency as well as occupational safety and health. Large sheet metals are difficult to move and burdensome to lift/transfer, and handling the sharp sheet edges may result in contact stress and/or cut injuries on the workers. Methods: Through observation, interview, and immersive simulation activities, a few problems related to current handling of sheet metals were identified. A sheet metal trolley-lifter was then designed and fabricated to address these issues. A pilot study on the use of the developed trolley-lifter for handling sheet metals was conducted to compare between the new and traditional handling methods. Results: The pilot study of the trolley-lifter showed promising results in terms of improving the cycle time, manpower utilization, and working postures compared with the traditional handling method. Conclusion: The trolley-lifter offers an alternative solution to automation and a mechanized assistive device by providing a simple mechanism to assist the handling of sheet metals effectively and safely.

A Study on the Construction Specification and Quality Assurance Criteria in Clay Paver (점토바닥벽돌의 품질 및 시공기준 연구)

  • Park, Dae-Gun;Lee, Sang-Yum;Kim, Kyoon-Tai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.6
    • /
    • pp.111-121
    • /
    • 2010
  • As the customer's interest for sidewalk block in the street or apartment complex is increasing, the materials of block which had been a concrete block exclusively are varied to clay paver, native rock and wood etc. Especially, the sales volume of clay paver which is environment-friendly and ergonomic is dramatically increasing every year with two digits growth rate, however, many problems like "Edge Cracking" "Freezing Breakage" "Bending Breakage" "Joint Gap" are happening frequently within a couple of hours after installation due to the durabilities. Because of the characteristics of Ceramic products, clay pavers are very easy to be broken when they are bumped against each other. In addition, they are relatively fragile by a freezing expansion breakage when exposed to water due to hydrophilic property as well as the intensity and absorptance of the products are varied with small difference from the production process such as production equipment and process control. Therefore, it costs a lot of money to repair the breakdown unless production and installation is carried out according to the strict criteria of the quality control. In this study, the symptoms of breakdown frequently happened in clay paver are classified by each type and finally the solution for this problem in the production of brick, installation and criteria of quality control through compressive strength and absorptance test is suggested.

Summative Usability Assessment of Software for Ventilator Central Monitoring System (인공호흡기 중앙감시시스템 소프트웨어의 사용적합성 총괄평가)

  • Ji-Yong Chung;You Rim Kim;Wonseuk Jang
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.363-376
    • /
    • 2023
  • According to the COVID-19, development of various medical software based on IoT(Internet of Things) was accelerated. Especially, interest in a central software system that can remotely monitor and control ventilators is increasing to solve problems related to the continuous increase in severe COVID-19 patients. Since medical device software is closely related to human life, this study aims to develop central monitoring system that can remotely monitor and control multiple ventilators in compliance with medical device software development standards and to verify performance of system. In addition, to ensure the safety and reliability of this central monitoring system, this study also specifies risk management requirements that can identify hazardous situations and evaluate potential hazards and confirms the implementation of cybersecurity to protect against potential cyber threats, which can have serious consequences for patient safety. As a result, we obtained medical device software manufacturing certificates from MFDS(Ministry of Food and Drug Safety) through technical documents about performance verification, risk management and cybersecurity application.The purpose of this study is to conduct a usability assessment to ensure that ergonomic design has been applied so that the ventilator central monitoring system can improve user satisfaction, efficiency, and safety. The rapid spread of COVID-19, which began in 2019, caused significant damage global medical system. In this situation, the need for a system to monitor multiple patients with ventilators was highlighted as a solution for various problems. Since medical device software is closely related to human life, ensuring their safety and satisfaction is important before their actual deployment in the field. In this study, a total of 21 participants consisting of respiratory staffs conducted usability test according to the use scenarios in the simulated use environment. Nine use scenarios were conducted to derive an average task success rate and opinions on user interface were collected through five-point Likert scale satisfaction evaluation and questionnaire. Participants conducted a total of nine use scenario tasks with an average success rate of 93% and five-point Likert scale satisfaction survey showed a high satisfaction result of 4.7 points on average. Users evaluated that the device would be useful for effectively managing multiple patients with ventilators. However, improvements are required for interfaces associated with task that do not exceed the threshold for task success rate. In addition, even medical devices with sufficient safety and efficiency cannot guarantee absolute safety, so it is suggested to continuously evaluate user feedback even after introducing them to the actual site.