• 제목/요약/키워드: Ergonomic factors

검색결과 222건 처리시간 0.027초

Ergonomic Approaches to Content Creation for 3D Displays

  • Kawai, Takashi;Kishi, Shinsuke;Kim, Sang-Hyun;Yamazoe, Takashi;Shibata, Takashi;Inoue, Tetsuri;Sakaguchi, Yusuke;Okabe, Kazushige;Yasuhiro, Kuno
    • Journal of Information Display
    • /
    • 제8권1호
    • /
    • pp.26-31
    • /
    • 2007
  • This paper presents ergonomic approaches to editing and evaluating content for 3D displays. Two systems, a nonlinear editing system and an evaluation system, were developed to improve viewing safety and comfort for 3D content observers and provide better usability for the creators from the viewpoint of ergonomics.

QFD와 불편도 실험을 통한 겨드랑 목발의 인간공학적 분석 및 디자인 (Ergonomic analysis and Design of an Axilla Crutch Through QFD and Discomfort Experiments)

  • 박희석;옥동민
    • 대한인간공학회지
    • /
    • 제27권4호
    • /
    • pp.103-108
    • /
    • 2008
  • The aim of this paper is to improve the design of a pair of axilla crutches through quality function deployment(QFD) and discomfort experiments. User needs for the crutches, as well as the engineering characteristics which have influence on the ergonomic quality of crutches were determined from the interview with many users. This information was entered in the house of quality, and the results show that the axillary pad and grip are the most important quality factors. And the results from the discomfort experiments confirmed the QFD output. A prototype reflecting the QFD results was proposed. The present study demonstrated how QFD approach can be a methodological tool geared to greater ergonomics consideration in product design.

기동헬기 음성 경고음의 인간공학적 설계에 관한 연구 (Ergonomic Design of Voice Warning Sounds Used in Utility Helicopter)

  • 정종혁;김태곤;고진환
    • 전기전자학회논문지
    • /
    • 제17권2호
    • /
    • pp.189-201
    • /
    • 2013
  • 본 논문은 연관된 합성기로부터 생성된 음성 경고음의 모델링에 관한 실험적 연구이다. 112명의 피실험자를 대상으로 심리적-육체적인 접근방법으로 4가지의 실험이 수행 되었다. 첫 번째 실험은 함성 경고음의 위급도를 지각하는 것을 모델링하여 6개의 음성-비음성 요소들을 구분하였다. 두 번째부터 네 번째의 실험은 위급도 지각의 주관적 변화와 객관적으로 계량화 할 수 있는 파라미터를 수치화 하였다. 이 논문은 응급성의 정도를 구분하는 것이 필요한 음성 합성 경고시스템의 설계에 적용될 수 있다.

An Instrumented Workstation to Evaluate Weight-Bearing Distribution in the Sitting Posture

  • Moriguchi, Cristiane S.;Sato, Tatiana O.;Coury, Helenice J.C.G.
    • Safety and Health at Work
    • /
    • 제10권3호
    • /
    • pp.314-320
    • /
    • 2019
  • Background: Sitting posture may be related to risk factors, including inadequate weight-bearing support, particularly when maintained for long periods. Considering that body weight is loaded in a closed support system composed of the seat, backrest, floor and working surface, the aims of the present study were to describe the development of an ergonomic sitting workstation to continuously record weight-bearing at the seat, chair, backrest, work surface, and floor and to test its measurement properties: reproducibility, criterion-related validity, and sensitivity. Methods: Rigid bodies (1 to 30 kg) and participant weights were recorded to evaluate the workstation measurement properties. Results: Rigid body tests showed variation values less than 0.050 kg on reproducibility test and errors below 5% of measured value on criterion validity tests. Participant tests showed no statistically significant differences between repeated measures ($p{\geq}0.40$), errors were less than 2% of participant weights an sensitivity presented statistically significant changes (p = 0.007). Conclusion: The sitting workstation proposed showed to be reliable, valid and sensitive for use in future ergonomic studies to evaluate the sitting posture.

How to Enhance Perceived Usefulness, Ease of Use, and Fit of Wearables: An Exploratory Study about the Physical Attributes of Smart Wristbands and Smartwatches

  • Shim, Soo In;Yu, Heejeong
    • International Journal of Advanced Culture Technology
    • /
    • 제11권4호
    • /
    • pp.302-309
    • /
    • 2023
  • Wearable devices, attached to the human body, track and enhance users' activities, health, and communication. Therefore, considering ergonomic factors in product design is crucial. However, previous research has somewhat overlooked the importance of integrating ergonomic design elements into a broad spectrum of design factors. This study aims to examine the impact of physical attributes inherent in smart wristbands and smartwatches on the perceived functional value, specifically, perceived usefulness, ease of use, and fit. A survey was conducted among 289 US adults who had experience using smart wristbands or smartwatches. The collected data were analyzed using descriptive statistics, factor analysis, Cronbach's alpha, t-test, MANOVA, and regression analysis in SPSS version 29. The results showed that the shape of the front display significantly influenced perceived ease of use, and the product's weight had a substantial impact on both perceived ease of use and fit. Furthermore, distinct technical features on the front display had varied effects on perceived usefulness, ease of use, and fit. Notably, the presence of activity tracking, alarm, and calendar functionalities led to distinct differences in ease of use and fit. Features such as distance tracking, phone call, social media notifications, text messaging, and time display functions showed significant influences on the perception of fit. These findings provide insights into the physical values of smart wristbands and smartwatches as perceived by users.

주행 진동 모드와 시트 진동을 고려한 추행 안락감 분석 (Evaluation of Ride Comfort Considering Seat and Ride Vibration Modes)

  • 김명규;유완석;김정훈
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.93-99
    • /
    • 2002
  • Ride comfort, one of the most important performances of a car, is affected by vibration, noise, dynamic movement, and ergonomic factors. Among these factors, ride comfort vibration is heavily affected by the seat system, tire, suspension, and body structure. In this study, vibration characteristics of seat, tire, suspension, and body structure are analyzed. The vibration transfer function from the road input to the human body is also investigated.

누적외상성질환 위험 요인의 정량적 평가 및 관리를 위한 점검표 개발 -자동차 조립 작업을 중심으로- (The Development of a Checklist for Quantitative Assessment of Risk Factors and Management of Cumulative Trauma Disorders : Application to Automobile Assembly Lines)

  • 이윤근;김현욱;임상혁;박희석
    • 한국산업보건학회지
    • /
    • 제11권1호
    • /
    • pp.56-69
    • /
    • 2001
  • Objectives : This study was designed to develop and standardize a checklist for ergonomic risk factors, and to provide ergonomic guidelines for managing cumulative trauma disorders (CTDs) in automobile assembly lines. Methods : The Checklist for Ergonomic Risk Factors (CERF-1) was developed based on the results of previous studies, and then modified after performing pilot study. Information on the symptoms possibly related with CTDs was obtained using a self-reported Questionnaire from 465 automobile assembly workers. Their job conditions were examined to assess risk factors through both direct observation and video analysis. Results : Rate of detecting risky job through CERF-1 was 85.6%, and was similar to that (88.8%) by Occupational Safety and Health Adminstration(OSHA) checklist but higher than that (63.7%) by American National Standards Institute(ANSI) Z-365. Relationship of the exposure scores derived from CERF-1 with levels of symptom was greater (r=0.49) than OSHA (r=0.28) and ANSI Z-365 (r=0.22). Considering the relationship, jobs scoring higher than 16 could be classified as the Risk Job. and lower than 16 as the Low Risk Job. Sensitivity and specificity of the Risk Job were 92.5 % and 31.5 %, respectively. Odds ratio (OR) after age adjustment was 5.69 (95 % confidence interval 3.15-10.29) for the Risk Job, and these ORs were significantly different from those of the Low Risk Job. The exposure scores were Quite valid, in that the scores at the main survey were significantly correlated with those at the follow-up survey, as suggested by test-retest(r=0.88) and inter-rater reliability(r=0.80). Conclusions : The CERF-1, developed in this study, will be an efficient tool for evaluation of risk jobs for CTDs in automobile assembly lines, and can be used easily by health care providers.

  • PDF

Ergonomic Design of Medic Work Table (MWT) for Medical Technologist

  • Choi, Kyeong-Hee;Lee, Sung-Yong;Lee, Jun-Hyub;Kong, Yong-Ku
    • 대한인간공학회지
    • /
    • 제35권6호
    • /
    • pp.595-609
    • /
    • 2016
  • Objective: The purpose of this study was to develop and validate the guidelines for Medic Work Table (MWT) based on the anthropometric data of medical technologists. Background: Users' anthropometric data such as sitting height, sitting elbow height, knee height, and so on are significant factors for designing comfortable and useful furniture. Thus, many guidelines for different types of desks and chairs based on the users' anthropometric data have been suggested to many researchers. However, few researches have been conducted to provide design guidelines for MWT for blood collecting task. Medical technologists often use their upper extremities to perform blood collecting task with high repetitions. These repeated motions could be a critical factor in the prevalence rate of Work-related Musculoskeletal Disorders (WMSDs). Therefore, a study on ergonomic design of MWT would be essential in preventing the WMSDs and improving the quality of the working environment of medical technologists. Method: This study suggested design guidelines for ergonomic MWT by focusing on the heights of the upper side and underside, depths of the inside and outside, and width of MWT through anthropometric studies and literature reviews. Afterwards, a new MWT was made using the suggested design guidelines for this study. Five healthy medical technologists participated to evaluate the original MWT and new MWT. All participants took part in the range of motion (ROM) test, electromyography (EMG) muscle activity test, and usability test to validate the suggested guidelines in this study. EMG signals of related muscles (Flexor Carpi Ulnaris, Extensor Carpi Ulnaris, Deltoid Anterior, and Biceps Branchii) were recorded through the surface electromyography system from both the original MWT and the new MWT. The ROM test of the shoulder and elbow flexion was also assessed using motion sensors. Results: The newly designed MWT showed decreased ROMs of the shoulder and elbow up to 22% and 18% compared to the original MWT. The muscle activities in the new MWT also showed a decrease of 13% in Anterior Deltoid, 6% in Biceps Brachii, 5% in Flexor Carpi Ulnaris, and 8% in Extensor Carpi Ulnaris muscle groups, compared to the original MWT. In the usability test, the satisfaction score of the new MWT was also 56.1% higher than that of the original MWT. Conclusion: This study suggested guidelines for designing MWT and validating the guidelines through qualitative and quantitative analyses. The results of motion analysis, muscle activity, and usability tests demonstrated that the newly designed MWT may lead to less physical stress, less awkward posture, and better physical user interface. Application: The recommended guidelines of the MWT would be helpful information for designing an ergonomic MWT that reduces physical loads and improves the performance of many medical technologists.

Relationships Between Rounded Shoulder Posture and Biceps Brachii Muscle Length, Elbow Joint Angle, Pectoralis Muscle Length, Humeral Head Anterior Translation, and Glenohumeral Range of Motion

  • Choi, Sil-ah;Cynn, Heon-seock;Lee, Ji-hyun;Kim, Da-eun;Shin, A-reum
    • 한국전문물리치료학회지
    • /
    • 제24권2호
    • /
    • pp.48-57
    • /
    • 2017
  • Background: Rounded shoulder posture (RSP), a postural abnormality, might cause shoulder pain and pathologic conditions. Although most previous research has investigated RSP focusing on the proximal structures of the shoulder, such as the scapula and pectoralis muscles, the relationship between RSP and anterior distal structures of the upper extremity, such as the biceps brachii muscle and elbow joint, is not clearly understood. Objects: This study aimed to investigate the correlations between RSP and the biceps brachii length, elbow joint angle (EJA), pectoralis minor length, general pectoralis major length, humeral head anterior translation (HHAT), glenohumeral internal rotation (IR), external rotation (ER), and horizontal adduction (HAD). Methods: Twelve subjects with RSP (6 male, 6 female) were recruited. All subjects fulfilled the RSP criteria indicated by a distance ${\geq}2.5cm$ from the posterior aspect of the acromion to the table in the supine position. The examiner measured each of the following parameters twice: RSP, biceps brachii length, EJA, pectoralis minor length, pectoralis major length, HHAT, glenohumeral IR, ER, and HAD. Pearson's correlation coefficient(r) was used to assess the correlation between RSP and all the variables. Results: There was a significant moderate positive correlation between RSP and biceps brachii length (r=.55, p=.032), moderate negative correlation between RSP and pectoralis minor length (r=-.62, p=.015), and moderate positive correlation between RSP and HHAT (r=.53, p=.038). Conclusion: The biceps brachii length, pectoralis minor length, and HHAT could be used to evaluate patients with RSP. Better understanding of the correlation between these factors and RSP could help in the development of effective methods to treat patients with this condition in clinical management.

사회심리적 스트레스 및 작업특성 요인이 직업성요통에 미치는 영향 (The Effects of Psychosocial Stress and Job Characteristics on Low Back Injury)

  • 허국강;박동현
    • 대한인간공학회지
    • /
    • 제19권2호
    • /
    • pp.15-31
    • /
    • 2000
  • The aim was to evaluate the prevailing ergonomic and psychosocial conditions regarding low back injury in an automobile assembly system. This study consisted of two parts. In the first part of the study, analytic biomechanical model and NIOSH guidelines were applied to evaluate risk levels of low back injury for automobile assembly jobs. Total of 246 workers were analysed. There were 20 jobs having greater back compressive forces than 300kg at L5/S1. Also, there were 44 jobs over Action Limit with respect to 1981 NIOSH guidelines. This might in part be explained by the ergonomic conditions of the company analysed generally being good, with a relatively low duration of 'combined' extreme work posture. The relationship between psychosocial factors and low back injury was examined in the second part of the study. It has recently been recognized that overall reaction to working conditions was influenced by a range of factors, some of which were physical and some psychosocial. The psychosocial environment surrounding the work place may contribute to the perception of risk and eventual ill-health. A battery of questionnaires concerning the psychosocial stress based on PWI(Psychosocial Well-being Index) and musculoskeletal pain symptoms at low back was completed by 246 workers at the same plant. Results showed that 207 out 246 workers experienced the symptoms and 27 workers were diagnosed as patients. Two groups(low stressed, high stressed) based on PWI score had no significant relationships with both symptoms and results of diagnosis. However, sensitivities for symptoms and diagnosis by PWI were 91.3% and 92.6% respectively. Finally, relationships between physical work load and psychosocial stress were analysed. Specifically, some postural factors {vertical deviation angle of forearm, horizontal deviation angle of upperarm, vertical deviation angle of thigh, etc) were highly correlated with psychosocial stress. The results illustrated that PWI scores were associated with some physical workloads. However, psychosocial stress levels couldn't be well related with the pain symptom as well as the actual incidence of low back injury since pain or discomfort regarding low back injury were more complex than that of other musculoskeletal disorders.

  • PDF