• 제목/요약/키워드: Equivalent section

검색결과 355건 처리시간 0.025초

배골형단면(背骨型斷面) 주상체(柱狀體)의 자유수면(自由水面)하에서의 비틂진동(振動)에 대(對)한 이차원적(二次元的) 부가관성(附加慣性)모우먼트의 계산(計算) (A Note on the Two-Dimensional Added Mass Moment of Inertia in Torsional Vibration of Cylinders of Curvilinear-Element Sections with Chines.)

  • 이기표;양영순
    • 대한조선학회지
    • /
    • 제11권2호
    • /
    • pp.41-44
    • /
    • 1974
  • A calculation of the two dimensional added mass moment of inertia for the Kim's chine form sections is made with a special consideration of a location of a axis of rotation. The results are compared with those of Lewis form section equivalent to the above chine form sections calculated by Kumai.

  • PDF

폐색구간 결정을 위한 기법연구 (A Study on Decision method of block section)

  • 이종우;황종규;정의진;정철범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.316-323
    • /
    • 2000
  • In railway train operations, a braking distance between two trains must be controlled on their speeds to avoid rear end collisions. The distance is decided by some parameters such that propulsion and braking performance of trains, gradient and etc. When determining this block distance, it is important to consider the two aspects that safety insurance at train running and increase of train running frequency. In this paper, we showed a methodologies of equiblock by consideration gradients and calculated optimal block speeds on the basis of the equivalent block distance.

  • PDF

천공된 기판 집적 도파관 다단 E-Plane 변환기 (Punched-SIW Multi-Section E-Plane Transformer)

  • 조희진;변진도;이해영
    • 한국전자파학회논문지
    • /
    • 제24권3호
    • /
    • pp.259-269
    • /
    • 2013
  • 본 논문에서는 다양한 기판 집적 도파관 전송선 두께를 가지는 시스템에 적용을 위해서 천공된 기판 집적 도파관 다단 E-plane 변환기를 제안한다. 본 제안 구조는 ${\lambda}_g/4$ 임피던스 변환기 원리를 적용하여 ${\lambda}_g/4$ 길이 내에 천공을 삽입한다. 천공된 기판 집적 도파관은 도파관 내부의 낮아진 capacitance를 통해 특성 임피던스가 증가되어 E-plane 변환기로 구현된다. 또한, 체비셰프 다항식을 적용하여 구현한 천공된 기판 집적 도파관 다단 E-plane 변환기는 대역폭을 개선하였다. 천공된 기판 집적 도파관 2단 E-plane 변환기는 11.45~13.6 GHz의 주파수 대역에서 삽입 손실 $1.57{\pm}0.11$ dB, 입력 반사 손실은 15 dB 이상으로 나타났다.

제왕절개술후 통증조절을 위해 PCA를 이용한 Morphine과 Meperidine의 제통효과 비교 (Comparison on Analgesic Effect of Morphine and Meperidine with Patient-Controlled Analgesia for the Pain Relief after Cesarean Section)

  • 이병호;이철우;김창재;정미영;박동숙;채준석
    • The Korean Journal of Pain
    • /
    • 제9권1호
    • /
    • pp.166-171
    • /
    • 1996
  • The purpose of this study is to compare the postoperative analgesic effect of morphine and meperidine, employing intravenous patient controlled analgesia after cesarean section. Among fifty nine parturients undergoing cesarean section with general anesthesia, 32 were administered morphine designated as 'morphine group', and 27 parturient administered meperidine as 'meperidine' group, during 48 hours after commencement of PCA. Doses administered, based on potency for this setting, were equivalent to 1 mg morphine or 10 mg meperidine. Loading dose was administered when parturient first complained of pain after cesarean section. This was followed with bolus dose, 1 mg for morphine group and 10 mg for meperidine group, with a lockout interval of 8 minutes between doses wherever parturient requested additional analgesia. Visual analog scale(VAS) pain scores during rest were significantly lower at only 1 and 2 hour for the meperidine group, than morphine group. Loading dose and cumulative dose at 1, 2 and 3 hours were significantly lower for meperidine group than the morphine group. There were no significant difference in total dose and hourly dose for 48 hours and cumulative dose at 6, 12, 24, and 48 hours between both groups. More than 90% of the parturients from both groups were satisfied with the analgesic effects of pain relief. Morphine group experienced side effects such as: pruritus, sedation and dizziness. Meperidine group had sedation, dizziness, nausea and local irritation. Neither group required any specific treatment for any of the above side effects. We conclude that meperidine had greater analgesic effect at early stage of post-operative period.

  • PDF

Effects of types of bridge decks on competitive relationships between aerostatic and flutter stability for a super long cable-stayed bridge

  • Hu, Chuanxin;Zhou, Zhiyong;Jiang, Baosong
    • Wind and Structures
    • /
    • 제28권4호
    • /
    • pp.255-270
    • /
    • 2019
  • Aerodynamic configurations of bridge decks have significant effects on the aerostatic torsional divergence and flutter forsuper long-span bridges, which are onset for selection of suitable bridge decksfor those bridges. Based on a cable-stayed bridge with double main spans of 1500 m, considering typical twin-box, stiffening truss and closed-box section, which are the most commonly used form of bridge decks and assumed that the rigidity of those section is completely equivalent, are utilized to investigate the effects of aerodynamic configurations of bridge decks on aerodynamic instability performance comprised of the aerostatic torsional divergence and flutter, by means of wind tunnel tests and numerical calculations, including three-dimensional (3D) multimode flutter analysis and nonlinear aerostatic analysis. Regarding the aerostatic torsional divergence, the results obtained in this study show twin-box section is the best, closed-box section the second-best, and the stiffening truss section the worst. Regarding the flutter, the flutter stability of the twin-box section is far better than that of the stiffening truss and closed-box section. Furthermore, wind-resistance design depends on the torsional divergence for the twin-box and stiffening truss section. However, there are obvious competitive relationships between the aerostatic torsional divergence and flutter for the closed-box section. Flutter occur before aerostatic instability at initial attack angle of $+3^{\circ}$ and $0^{\circ}$, while the aerostatic torsional divergence occur before flutter at initial attack angle of $-3^{\circ}$. The twin-box section is the best in terms of both aerostatic and flutter stability among those bridge decks. Then mechanisms of aerostatic torsional divergence are revealed by tracking the cable forces synchronous with deformation of the bridge decksin the instability process. It was also found that the onset wind velocities of these bridge decks are very similar at attack angle of $-3^{\circ}$. This indicatesthat a stable triangular structure made up of the cable planes, the tower, and the bridge deck greatly improves the aerostatic stability of the structure, while the aerodynamic effects associated with the aerodynamic configurations of the bridge decks have little effects on the aerostatic stability at initial attack angle of $-3^{\circ}$. In addition, instability patterns of the bridge depend on both the initial attack angles and aerodynamic configurations of the bridge decks. This study is helpful in determining bridge decksfor super long-span bridges in future.

인체 상 위치를 고려한 다양한 WBAN 안테나 설계 (Design of Various WBAN Antennas Considering for the Location on a Human Body)

  • 탁진필;최재훈
    • 한국전자파학회논문지
    • /
    • 제25권11호
    • /
    • pp.1095-1103
    • /
    • 2014
  • WBAN은 다양한 응용 가능성 때문에 최근 들어 많은 관심을 받고 있다. 본 논문에서는 기기의 위치에 따른 WBAN 통신 환경에 적합한 몇 가지 안테나와 모의 인체 제작에 대하여 소개하고자 한다. WBAN 시스템은 인체 내부 및 인체 표면에서 동작하므로 고유전율 및 고도전율을 갖는 인체 매질에 대한 영향을 고려해야 하며, 특히 안테나는 근역장 매질 특성에 따라 안테나의 방사 특성 및 반사 손실 특성이 변하게 되므로, 이를 고려한 안테나 설계가 요구된다. 또한, 안테나의 인체 영향을 고려하기 위해 모의 인체를 이용해 안테나를 설계하고 측정하였다. 서론에서는 WBAN 통신 채널의 분류를 소개하고, 각각의 통신 채널에 적합한 안테나의 특성에 대해 간단히 언급하였다. 제안된 몇 가지 안테나 사례 및 모의 인체 구현에 대하여 논의하였다. 결론에서는 안테나 설계 시 고려해야 할 사항과 향후 연구에 대해 언급하였다.

다양한 보강상세를 갖는 CFRP로 표면매립 보강된 철근콘크리트 보의 보강효과 (Strengthening Effect of Reinforced Concrete Beams Strengthened with NSM CFRP Reinforcements and Various Reinforcement Details)

  • 정우태;박영환;박종섭;김철영
    • 콘크리트학회논문집
    • /
    • 제23권6호
    • /
    • pp.781-790
    • /
    • 2011
  • 이 연구는 다양한 보강상세를 갖는 CFRP(carbon fiber reinforced polymer)로 표면매립 보강된 철근콘크리트보의 보강효과에 관한 실험연구이다. 다양한 보강상세를 갖는 표면매립공법의 보강효과를 분석하기 위해 실험변수로 CFRP 보강재의 단면형상, 보강량, 매립 개수 및 위치 등의 다양한 보강상세를 적용하여 총 14개의 실험체를 제작하였다. 실험 결과, 표면매립보강의 파괴모드는 보강재 단면형상에 상관없이 보강재와 충전재가 하나로 거동하는 부착파괴 및 보강재 파단을 보였고, 홈 간격에 따라 홈 주변 콘크리트의 파괴면이 중첩되어 조기 부착파괴가 발생하는 것으로 나타났다. 등가 단면을 고려하여 부착상세를 개선한 기계적 맞물림(MI) 실험체의 파괴모드는 기존 부착파괴에서 CFRP 보강재 파단으로 개선되었고, CFRP 효율은 83%에서 100%로 향상되었다.

지중강판 박스구조물을 위한 파형강판 해석 모델 (Analysis Model of Corrugated Steel Plates for Soil-Metal Box Culverts)

  • 최동호;이종선;나호성
    • 한국지반환경공학회 논문집
    • /
    • 제11권11호
    • /
    • pp.5-18
    • /
    • 2010
  • 본 연구에서는 지간 15m 이하의 지중파형강판 박스구조물의 3차원 해석 시 적용 가능한 3차원 보강판 모델을 제안하고 검증하였다. 3차원 보강판 모델은 실제 파형강판의 단면계수와 종방향과 길이방향의 단면특성을 고려하여 지중강판 박스구조물을 모델링함으로써, 3차원 해석 시 모델링을 간편하게 하고 해석시간을 단축할 수 있는 유용한 해석 모델이다. 이 모델을 검증하기 위해 3단계의 시공과정(정점부까지의 뒷채움, 토피고까지의 뒷채움, 활하중재하)에 따른 거동분석으로부터 최대 변위와 최대모멘트를 유발하는 재하상태를 도출하였고, 제안된 단면을 통해 파형강판의 거동을 분석하였다. 분석 결과를 3차원 등가판 모델, 2차원 모델, 실제파형강판 구조물과 동일하게 모델링한 3차원 Corrugated 판 모델과 비교 검증하였다. 해석결과 2차원 모델과 3차원 등가판 모델은 활하중 조건에서 3차원 Corrugated 판 모델과 큰 차이를 나타내었으나, 3차원 보강판 모델은 모든 해석 결과에서 3차원 Corrugated 판 모델과 일치하는 결과를 나타내었다.

78 kW급 농업용 트랙터의 로타리 경운 작업에 따른 등가 토크 분석 (Analysis of Equivalent Torque of 78 kW Agricultural Tractor during Rotary Tillage)

  • 백승민;김완수;박성운;김용주
    • 한국정보전자통신기술학회논문지
    • /
    • 제12권4호
    • /
    • pp.359-365
    • /
    • 2019
  • 본 연구는 트랙터 변속기의 성능평가, 내구성 향상 및 최적 설계 등을 위한 기초 연구로써 로타리 작업에 따른 78 kW급 농업용 트랙터의 엔진 토크를 CAN 통신을 이용하여 수집하고, 등가 토크를 분석하였다. 신뢰성 높은 트랙터 개발을 위해서는 실제 농작업 환경에서 발생하는 부하를 등가 토크로 변환하여, 분석하는 것이 필요하다. 등가 토크는 대표적인 누적 손상법인 Palmgren-Miner 식으로 작업 및 선회구간에 대하여 계산되었으며, 각각 229.2, 136.7 Nm로 나타났다. 로타리 작업구간에서 최대 및 평균 토크는 각각 336.0, 234.4 Nm로 나타났으며, 선회구간의 최대 및 평균 토크는 288.0, 134.6 Nm로 나타났다. 로타리 작업구간에서의 엔진 토크는 PTO를 통해 토양을 경운하기 때문에 선회구간보다 높게 나타났다. 엔진의 최대 및 정격 토크는 각각 387.0, 323.0 Nm로, 로타리 작업 및 선회구간의 등가 토크보다 각각 183%, 136% 높게 나타났다. 국내 트랙터 회사는 일반적으로 엔진의 정격 토크를 기준으로 변속기를 설계하기 때문에, 실제 작업 토크와 다소 차이가 있다. 그러므로 최적 설계를 위해 실제 작업 토크를 고려하는 것이 필요할 것으로 판단된다.

Pre-stress를 도입한 Steel Beam에 관한 실험적 연구 (Experimental Study on Pre-Stresses Steel Beam)

  • 조진구;박병기
    • 한국농공학회지
    • /
    • 제17권4호
    • /
    • pp.3921-3930
    • /
    • 1975
  • This research was carried out to investigate several mechanical characteristics of pre-stressed steel beams. The configuration of specimens used for this study were as follows; a cover plate having permissible fiber stress of 4,000 kg/$\textrm{cm}^2$ was welded at bottom having the allowable bending stress 2500 kg/$\textrm{cm}^2$ steel beam, the section ratios of pre-stressed steel beam and cover plate were 0.5 and 0.6. Adopted pre-stresses were 0%, 50%, and 100% of an allowable fiber stress of a steel beam. The results obtained from the study may be summarized as follows; 1. The elastic range of a beam was increased by the application of pre-stress to the beam, which leads to a lighter section. 2. The permissible moment capacity of a pre-stressed steel beam was greated than that of a steel beam without pre-stressing. 3. The equivalent allowable stress induced by adopting the different section ratio of pre-stressed beam to cover plate were figured out 4. The optimum value of section ratio of beam and cover plate was 0.3 to 0.4 in case of a 1.5m span composite beam, a combination of an allowable stress 2,500kg/$\textrm{cm}^2$ steel beam and a permissible fiber stress 4,000 kg/$\textrm{cm}^2$ steel cover plate, was used. 5. The magnitude of the pre-stress was desirable to be same as the allowable stress of a steel beam. 6. It was concluded that if the construction techniques in the field are developed and improved, the practicing of pre-stress to the steel structure has a promising future.

  • PDF