• 제목/요약/키워드: Equivalent Parameter

검색결과 611건 처리시간 0.029초

5상 농형 유도전동기의 정수 추정 (Parameters Estimation of Five-phase Squirrel-Cage Induction Motor)

  • 김민회
    • 전기학회논문지P
    • /
    • 제61권4호
    • /
    • pp.199-205
    • /
    • 2012
  • This paper propose a improved parameter estimations of five-phase squirrel-cage induction motor(IM) for speed control system on field oriented control(FOC). In order to high performance control of ac the motors using a FOC and DTC(direct torque control) algorithm, there are required precise motor parameters for slip calculation, flux observer, controller gain, rotor position and speed estimation, and so on. We are suggest a estimation method of the motor parameters that developing five-phase squirrel-cage IM have a stator of concentrated winding for experimental. There are results of stator winding test, no-load test, locked rotor test, and obtained equivalent circuits using manufactured experimental apparatus. For presenting the superior performance of the speed control system in adapted the parameters, experimental results are presented using a 32-bit fixed point TMS320F2812 DSP with 1.5[KW] IM.

주파수 변화에 따른 5상 농형 유도전동기의 정수 추정 (Parameters Estimation of Five-Phase Squirrel-Cage Induction Motor in Changing Variable Frequency)

  • 김민희
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.241-247
    • /
    • 2014
  • This paper propose a variable parameter estimations of five-phase squirrel-cage induction motor(IM) for speed control system. In order to high performance control of AC motor using a field oriented control(FOC) and direct torque control(DTC) algorithm, there are required precise motor parameters for slip calculation, flux observer, controller gain, rotor position, speed estimation, and so on. We are suggest a analyzed estimation results of the motor parameters that developing five-phase squirrel-cage IM have a stator of concentrated winding for experimental of variable input power frequency. There are results of stator winding test, no-load test, locked-rotor test, variable actual load test, and estimated parameters of equivalent circuits using manufactured experimental apparatus by IEEE Standard Test Procedure for Polyphase Induction Motors and Generators 112-2004.

그림자식 모아레를 이용한 형상측정법의 정확도 개선에 관한 연구 (A Study on the Improvement of Accuracy of Shape Measurement in the Shadow Moire Method)

  • 박경근;박윤창;정경민
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 춘계학술대회 논문집
    • /
    • pp.175-180
    • /
    • 1999
  • Generally, When we measure of object 3D surfaces with phase shifting shadow moire method, it is use of optical system consist of light source, grating, and ccd camera. At this time, it is important parameter that vertical distance of grating and camera, grating and light source, and horizontal distance of camera and light source. When use camera consist of complex lens vertical distance of grating and camera is unknown parameter. From this cause equivalent wave length of moire fringe is uncertain. In this study, We exactly obtain a vertical distance of grating and camera so improve on measurement accuracy.

  • PDF

GaAs SBGFET의 잡음동작에 관한 연구 (Study on Noise Behavior of GaAs SBGFET)

  • 박한규
    • 대한전자공학회논문지
    • /
    • 제14권3호
    • /
    • pp.6-11
    • /
    • 1977
  • GaAs Schottky Barrier Gate 전계효과트랜지스터의 잡음동작을 잡음등가회로를 사용하여 연구하였으며, 부가구인 잡음근원은 pinch-off영역에서 GaAs FET bias에 의하여 구현되었다. 이것이 바로 intervalley 산란잡음과 hot electron에 의한 잡음이었다. 본 논문의 잡음등가회로에서는 carrier의 포화속도와 기생저항의 영향을 고려한 parameter를 정하였다.

  • PDF

DC/DC 컨버터를 이용한 DC Bus 커패시터의 간단한 ESR 측정 기법 (A Simple ESR Measurement Method for DC Bus Capacitor Using DC/DC Converter)

  • 손진근;김진식
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.372-376
    • /
    • 2010
  • Electrolytic capacitors have been widely used in power electronics system because of the features of large capacitance, small size, high-voltage, and low-cost. Electrolytic capacitors, which is most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. Therefore it is important to estimate the parameter of an electrolytic capacitor to predict the failure. The estimation of the equivalent series resistance(ESR) is important parameter in life condition monitoring of electrolytic capacitor. This paper proposes a simple technique to measure the ESR of an electrolytic capacitor. This method uses a switching DC/DC boost converter to measure the DC Bus capacitor ESR of power converter. Main advantage of the proposed method is very simple in technique, consumes very little time and requires only simple instruments. Simulation results are shown to verify the performance of the proposed method.

등가 자기 회로를 이용한 단상 유도형 동기 릴럭턴스 전동기의 인덕턴스 산정에 관한 연구 (A Study on Inductance calculation of Line start Synchronous Reluctance Motor using Equivalent Magnetic Circuit Method)

  • 하승형;이지영;홍정표;남혁;강규홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1117-1119
    • /
    • 2005
  • The inductance is an important parameter in order to analyze steady state of LSRM(Line-start Synchronous Reluctance Motor). If FEM(Finite Element Method) is used to compute the parameter according to the change of flux barriers and conductor bars, less analysis time is required. Therefore, this paper adopts equivalent magnetic circuit method to simply calculates inductance, and the result is verified by comparing with the results by FEM.

  • PDF

점용접시편의 극한하중과 피로특성에 관한 실험적 고찰 (An Experimental Investigation of Limit Loads and Fatigue Properties of Spot Welded Specimens)

  • 이형일;김남호;이태수
    • 대한기계학회논문집A
    • /
    • 제24권1호
    • /
    • pp.38-51
    • /
    • 2000
  • The study on the mechanical behavior of a spot-welded specimen is largely divided into the quasi-static overload failure analysis and the fatigue failure prediction. The main issue in an overload analysis is to examine the critical loads, thereby providing a generalized overload failure criterion. As the welding spot forms a singular geometry of an external crack type, fatigue failure of spot-welded specimens can be evaluated by means of a fracture parameter. In this study, we first present the limit loads of 4 representative types of single spot-welded specimens in terms of the base metal yield strength and specimen geometries. Recasting the load vs. fatigue life relationships experimentally, obtained here, we then predict the fatigue life of spot-weld specimens with a single parameter denoted the equivalent stress intensity factor. This crack driving parameter is demonstrated to successfully describe the effects of specimen geometry and loading type in a comprehensive manner. The suggested fatigue life formula for a single spot weld can play a key, role in the design and assessment of spot-welded panel structures, in that the fatigue strength of multi-spots is eventually determined by the fatigue strength of each single spot.

수퍼 커패시터의 고장진단을 위한 파라미터의 측정기법과 순시전압강하 보상장치에의 응용사례 (Parameter Measurement Method for Super Capacitor Failure Diagnosis and Application of Voltage Sag Compensation System Using Super Capacitor)

  • 손진근
    • 한국ITS학회 논문지
    • /
    • 제8권6호
    • /
    • pp.173-179
    • /
    • 2009
  • 본 논문에서는 순시전압강하 보상장치 등의 전력변환시스템에 사용되는 수퍼 커패시터(또는 전기이중층콘덴서; EDLC)의 고장진단을 위한 파라미터의 측정기법에 관한 연구를 수행하였다. 직류 에너지의 저장을 위한 기존의 장치에는 납축전지 또는 전해 커패시터를 사용하여 왔으나 환경문제 및 에너지밀도의 측면에서 불리하여 최근에는 수퍼 커패시터의 사용이 주목을 받고 있다. 따라서 본 논문에서는 이러한 수퍼 커패시터의 내부 특성 및 고장 마모 등을 분석하기 위한 커패시터의 등가직렬저항(ESR) 및 정전용량을 측정하는 기법을 제시하여 고장진단의 주요한 데이터에 활용이 가능토록 하였으며, 또한 수퍼 커패시터를 적용한 순간전압강하에 대한 응용 실험을 수행하여 그 결과를 함께 제시하였다.

  • PDF

Extraction of Passive Device Model Parameters Using Genetic Algorithms

  • Yun, Il-Gu;Carastro, Lawrence A.;Poddar, Ravi;Brooke, Martin A.;May, Gary S.;Hyun, Kyung-Sook;Pyun, Kwang-Eui
    • ETRI Journal
    • /
    • 제22권1호
    • /
    • pp.38-46
    • /
    • 2000
  • The extraction of model parameters for embedded passive components is crucial for designing and characterizing the performance of multichip module (MCM) substrates. In this paper, a method for optimizing the extraction of these parameters using genetic algorithms is presented. The results of this method are compared with optimization using the Levenberg-Marquardt (LM) algorithm used in the HSPICE circuit modeling tool. A set of integrated resistor structures are fabricated, and their scattering parameters are measured for a range of frequencies from 45 MHz to 5 GHz. Optimal equivalent circuit models for these structures are derived from the s-parameter measurements using each algorithm. Predicted s-parameters for the optimized equivalent circuit are then obtained from HSPICE. The difference between the measured and predicted s-parameters in the frequency range of interest is used as a measure of the accuracy of the two optimization algorithms. It is determined that the LM method is extremely dependent upon the initial starting point of the parameter search and is thus prone to become trapped in local minima. This drawback is alleviated and the accuracy of the parameter values obtained is improved using genetic algorithms.

  • PDF

냉간압연강 판재 기계적 접합부의 십자형 인장 하중하에서의 피로강도 (Fatigue Strength Evaluation of Mechanical Press Joints of Cold Rolled Steel Sheet under Cross-Tension Loading)

  • 김종봉;김택영;강세형;김호경
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.1-7
    • /
    • 2014
  • In this study, for the evaluation of the static and fatigue joining strength of the joint, the geometry of the cross-tension specimen was adopted. The specimens were produced with optimal joining force and fatigue life of the clinch joint specimens was evaluated. The material selected for use in this study was cold rolled mild steel (SPCC) with a thickness of 0.8 mm. The maximum tensile load was 708 N for the specimen with single point. The fatigue endurance limit (=42.6 N) per point approached to 6% of the maximum tensile strength at a load ratio of 0.1, suggesting that the joints are vulnerable to cross-tension loading during fatigue. Compared to equivalent stress and maximum principal stress, the SWT fatigue parameter and equivalent strain can properly predict the current experimental fatigue life. The SWT parameter can be expressed as $SWT=2497.5N^{-0.552)_f$.