• Title/Summary/Keyword: Equivalent Area

Search Result 847, Processing Time 0.024 seconds

Biomechanical Test for Repair Technique of Full-thickness Rotator Cuff Tear

  • Lim, Chae-Ouk;Park, Kyoung-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.51-58
    • /
    • 2016
  • The arthroscopic rotator cuff repair is now considered a mainstream technique with highly satisfactory clinical results. However, concerns remain regarding healing failures for large and massive tears and high revision rate. In recent decades, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. The focus of biomechanical test in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. Recent studies have shown that a transosseous tunnel technique provides improved contact area and pressure between rotator cuff tendon and insertion footprint, and the technique of using double rows of suture anchors to recreate the native footprint attachment has been recently described. The transosseous equivalent suture bridge technique has the highest contact pressure and fixation force. In this review, the biomechanical tests about repair techniques of rotator cuff tear will be reviewed and discussed.

Petrochemical and Fluid Inclusion Study on the Porphyritic Granite in the Yonghwa-Seolcheon Area (용화(龍化)-설천(雪川) 지역(地域)에 분포하는 백악기 반상화강암(斑狀花崗岩)의 암석화학(岩石化學) 및 유체포유물(流體包有物)에 관한 연구(硏究))

  • Youn, Seok-Tai;Park, Hee-In
    • Economic and Environmental Geology
    • /
    • v.28 no.5
    • /
    • pp.445-454
    • /
    • 1995
  • The petrochemical data of the porphyritic granites of Cretaceous age in the Yonghwa-Seolcheon area show the trend of subalkaline magma, calc-alkaline magma, I-type granitoid and magnetite series. This granite is the relevant igneous rock of gold-silver mineralization in this mining district Fluid inclusions have been studied in phenocryst quartz from the Cretaceous porphyritic granite. Three main types of fluid inclusion were found : liquid-rich inclusion(I type), gas-rich inclusion(II type) and solid-bearing inclusions(III-A, III-B). The solid-bearing inclusions(III-A,B) represent the earliest trapped fluids. They have salinities between 41.0 and 67.5 wt% equivalent to NaCl. These are high saline inclusions containing NaCl and KCl daughter crystals. Homogenization temperature inferred from the fluid inclusion study ranges from 650 to $75^{\circ}C$ Type I and II inclusions were observed within the same fracture. This cause for these differences in degree of filling is evidence of boiling. Salinities of type I and II inclusions range from 9.87 wt% to 15.29 wt%, from 8.40 wt% to 14.64 wt% NaCl equivalent, respectively.

  • PDF

Wind-resistant performance of cable-supported bridges using carbon fiber reinforced polymer cables

  • Zhang, Xin-Jun;Ying, Lei-Dong
    • Wind and Structures
    • /
    • v.10 no.2
    • /
    • pp.121-133
    • /
    • 2007
  • To gain understanding of the applicability of carbon fiber reinforced polymer (CFRP) cable in cable-supported bridges, based on the Runyang Bridge and Jinsha Bridge, a suspension bridge using CFRP cables and a cable-stayed bridge using CFRP stay cables are schemed, in which the cable's cross-sectional area is determined by the principle of equivalent axial stiffness. Numerical investigations on the dynamic behavior, aerostatic and aerodynamic stability of the two bridges are conducted by 3D nonlinear analysis, and the effect of different cable materials on the wind resistance is discussed. The results show that as CFRP cables are used in cable-supported bridges, (1) structural natural frequencies are all increased, and particularly great increase of the torsional frequency occurs for suspension bridges; (2) under the static wind action, structural deformation is increased, however its aerostatic stability is basically remained the same as that of the case with steel cables; (3) for suspension bridge, its aerodynamic stability is superior to that of the case with steel cables, but for cable-stayed bridge, it is basically the same as that of the case with steel stay cables. Therefore as far as the wind resistance is considered, the use of CFRP cables in cable-supported bridges is feasible, and the cable's cross-sectional area should be determined by the principle of equivalent axial stiffness.

A study on stormwater fee imposition for sustainable rainwater management (지속가능한 빗물관리를 위한 강우유출수 부담금 도입방안 검토)

  • Kim, Gil-Bok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.103-110
    • /
    • 2019
  • Management of stormwater runoff is considered a nationwide challenge. To deal with this challenge, many researches have been conducted to study initial stage of stormwater fee imposition. The objective of this study was to recommend a framework for stormwater fee imposition not only for funding the stormwater management programs but also for encouraging people to decrease impervious area. This study focused on, regulations, financial resources and international cases related to stormwater runoff management. Polluter pays principle, which is generally recognized environmental policy principle is regarded the basis of stormwater fee imposition. Three components suggested for the stormwater rate structure are 1) stormwater utility revenue requirement, 2) billable equivalent stormwater unit, 3) system unit cost. The key point of stormwater rate structure is the "Equivalent Residential Unit(ERU)". The concept of an ERU is one residential area with a runoff coefficient. The runoff coefficient is that portion of rainfall that becomes runoff rather than infiltrating into the ground. In addition to this, this study took into account the observed data simulation for the separation of stormwater treatment expenditure from the comprehensive wastewater treatment cost.

Hydrogeochemistry of groundwaters in Boeun Area, Korea

  • Park, Seong-Sook;Yun, Seong-Taek;Kim, Kyoung-Ho;Kweon, Jang-Soon;Sung, Ig-Hwan;Lee, Byeong-Dae
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.519-519
    • /
    • 2003
  • We performed a hydrochemical study on a total of 89 bedrock groundwaters collected from preexisting wells (30 to 300 m deep) in the Boeun area. Hydrochemical data showed significant variations in the area, due to varying degrees of anthropogenic pollution. The waters were mostly enriched in Ca and HCO$_3$ but locally contained significant concentrations of anthropogenic constituents in the general order of Cl >NO$_3$>SO$_4$. In particular, about 11% of the examined wells exceeded the drinking water standard with respect to nitrate. We consider that aquifers in the area are locally highly susceptible to the contamination related to agricultural activities. Diagrams showing the relationships between the summation of cations (∑cations) and the concentration of several anions with different origin (natural versus anthropogenic) were used to estimate the relative role of anthropogenic contamination. A good correlation was observed for the relationship between ∑cations and bicarbonate, indicating that water-rock interaction (namely, hydrolysis of silicate minerals) is most important to control the water quality. Thus, we made an assumption that the equivalent of dissolved cations for a water should be equal to the alkalinity, if the chemistry were controlled solely by a set of natural weathering reactions. If we excluded the equivalent quantities of cations and bicarbonate (natural origin) from the acquired data for each sample, the remainder therefore could be considered to reflect the degree of anthropogenic contamination. Finally, we performed a multiple regression approach for hydrochemical data using the ∑cations as a dependent variable and the concentration data of each anion (natural or anthropogenic) as an independent variable. Using this approach, we could estimate the relative roles of anthropogenic and natural processes. Rather than the conventional evaluation scheme based on water quality criteria, this approach will be more useful and reasonable for the evaluation of groundwater quality in a specific region and also can be used for planning appropriate protection and remedial actions.

  • PDF

Use of measuring gauges for in vivo accuracy analysis of intraoral scanners: a pilot study

  • Iturrate, Mikel;Amezua, Xabier;Garikano, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.191-204
    • /
    • 2021
  • PURPOSE. The purpose of this study is to present a methodology to evaluate the accuracy of intraoral scanners (IOS) used in vivo. MATERIALS AND METHODS. A specific feature-based gauge was designed, manufactured, and measured in a coordinate measuring machine (CMM), obtaining reference distances and angles. Then, 10 scans were taken by an IOS with the gauge in the patient's mouth and from the obtained stereolithography (STL) files, a total of 40 distances and 150 angles were measured and compared with the gauge's reference values. In order to provide a comparison, there were defined distance and angle groups in accordance with the increasing scanning area: from a short span area to a complete-arch scanning extension. Data was analyzed using software for statistical analysis. RESULTS. Deviations in measured distances showed that accuracy worsened as the scanning area increased: trueness varied from 0.018 ± 0.021 mm in a distance equivalent to the space spanning a four-unit bridge to 0.106 ± 0.08 mm in a space equivalent to a complete arch. Precision ranged from 0.015 ± 0.03 mm to 0.077 ± 0.073 mm in the same two areas. When analyzing angles, deviations did not show such a worsening pattern. In addition, deviations in angle measurement values were low and there were no calculated significant differences among angle groups. CONCLUSION. Currently, there is no standardized procedure to assess the accuracy of IOS in vivo, and the results show that the proposed methodology can contribute to this purpose. The deviations measured in the study show a worsening accuracy when increasing the length of the scanning area.

Measurement of the vocal tract area of vowels By MRI and their synthesis by area variation (MRI에 의한 모음의 성도 단면적 측정 및 면적 변이에 따른 합성 연구)

  • Yang, Byung-Gon
    • Speech Sciences
    • /
    • v.4 no.1
    • /
    • pp.19-34
    • /
    • 1998
  • The author collected and compared midsagittal, coronal, coronal oblique, and transversal images of Korean monophthongs /a, i, e, o, u, i, v/ produced by a healthy male speaker using 1.5 T MR, VISION. Area was measured by computer software after tracing the cross-section at different points along the tract. Results showed that the width of the oral and pharyngeal cavities varied compensatorily from each other on the midsagittal dimension. Formant frequency values estimated from the area functions of the seven vowels showed a strong correlation (r=0.978) with those analyzed from the spoken vowels. Moreover, almost all of 35 students who listened to the synthesized vowels from area data perceived the synthesized vowels as equivalent to the spoken ones. Movement of constriction points of vowel /u/ with wider lip opening sounded /i/ and led to slight changes in vowel quality. Jaw and tongue movement led to major volume variation with an anatomical limitation. Each comer vowel varied systematically from a somewhat constant volume of the average area. Thus, the author proposed that any simulation studies related to vocal tract area variation should reflect its constant volume. The results may be helpful to verify exact measurement of the vocal tract area through vowel synthesis and a simulation study before having any operation of the vocal tract.

  • PDF

Effect of Weight Loads Applied to the Ankle on Walking Factors of a Stroke Patient (발목에 적용한 무게 부하가 뇌졸중 환자의 보행요소에 미치는 영향)

  • Lee, Su-Kyoung
    • PNF and Movement
    • /
    • v.16 no.2
    • /
    • pp.179-185
    • /
    • 2018
  • Purpose: This study aimed to analyze the visual and spatial elements of the gait of a stroke patient who had diverse ankle weight loads applied, according to weight changes. Methods: The subject was a 57-year-old stroke patient diagnosed and hospitalized with a left intracerebral hemorrhage. A weight equivalent to 0%, 1%, and 2% of his body weight was applied to the area 5cm upward from the ankle using a Velcro strap. He was then trained on a treadmill, receiving a six-minute walk test to evaluate his gait ability. A gait analyzer was used to collect visual and spatial elements, such as gait distance, gait velocity, cadence, step length, stride length, and swing phase, according to a weight load equivalent to 0%, 1%, and 2% of his body weight. Results: According to the results of applying 0%, 1%, and 2% of his body weight on the ankle, except for gait velocity, his gait distance, cadence, step length, stride length, and swing phase were higher when 1% of his body weight was applied compared to 0% or 2% of his body weight. Conclusion: Applying a weight equivalent to 1% of the body weight to the ankle positively affected the visual and spatial element of the gait and heightened the efficiency of exercise during treadmill training, a gait-training tool generally used for stroke patients. However, the result is difficult to generalize because the number of subjects was small with only one subject.

Finite Element Analysis and Validation for Dimpled Tube Type Intercooler Using Homogenization Method (균질화 기법을 이용한 딤플 튜브형 인터쿨러의 유한요소해석 및 검증)

  • Lee, Hyun-Min;Heo, Seong-Chan;Song, Woo-Jin;Ku, Tae-Wan;Kang, Beom-Soo;Kim, Jeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.2
    • /
    • pp.153-161
    • /
    • 2009
  • Three-dimensional finite-element methods(FEM) have been used to analyze the thermal stress of an exhaust gas recirculation(EGR) cooler due to thermal and pressure load. Since efficiency and capability of the heat exchanger are mainly dependent on net heat transferring area of the EGR cooler system, the tube inside the system has a numerous dimples on the surface. Thus for finite element analysis, firstly the dimple-typed tube is modeled as a plain element without the dimple, and then the equivalent thermal conductivities and elastic modulus are calculated. This work describes the numerical homogenization procedure of the dimple-typed tube and verifies the equivalent material properties by comparison of a single unit and the actual full model. Finally, the homogenization scheme presented in this study can be efficiently applied to finite element analyses for the thermal stress and deformation behavior of the EGR cooler system with the dimple-typed tube.

The Study on the Mechanical Behavior of the Anastomosis with respect to the Thickness Variation of Elastic Foundation Using Simplified Suturing Model (단순봉합모델을 이용한 문합에서 탄성경계층의 두께 변화에 따른 기계역학적 거동에 관한 연구)

  • 이성욱;한근조;심재준;한동섭;김태형
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.8
    • /
    • pp.188-195
    • /
    • 2004
  • In this paper we analyzed the mechanical behavior with respect to the thickness variation of elastic foundation(fatty tissue) in end-to-end anastomosis. This study considered the preliminary deformed shape induced by suturing in the anastomosis of coronary artery and PTFE with different diameters using simplified suturing model and the fatty tissue surrounding heart and coronary artery for more accurate result using finite element method. Area compliance(CA) was used to analyze the final deformed shape of the anastomotic part with respect to the thickness variation of fatty tissue under mean blood pressure, 100mmHg(13.3㎪). And Equivalent and circumferential stresses in the anastomosis were also analyzed with respect to the change of initial diameter ratio( $R_1$) and fatty tissue thickness( $T_{F}$). The results obtained were as follows : 1 When the elastic foundation, assumed to be incompressive material, surrounded the grafts in anastomosis, the compliance mismatch of artery and PTFE was reduced by 47 -72%. 2. As the initial diameter ratio( $R_1$) became larger, the higher difference of compliance was induced in spite of elastic foundation surrounding grafts. 3. The maximum nondimensional circumferential stress is twice or three times as high as the maximum nondimensional equivalent stress in the anastomotic part.t.