• 제목/요약/키워드: Equilibrium Air

검색결과 301건 처리시간 0.021초

Study on the Equilibrium Point of Heat and Mass Transfer between Liquid Desiccant and Humid Air with in the Solar Air Conditioning System

  • Sukmaji, I.C.;Rahmanto, H.;Agung, B.;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.161-167
    • /
    • 2009
  • The liquid solar air conditioning system is introduced as an alternative solution to control air condition and to save electrical energy consumption. The heat and mass transfer performances of dehumidifier/regenerator in liquid solar air conditioning system are influenced by air and desiccant condition. The application of this system, the thermal energy from the sun and inlet air are unable to control, but operation parameter of other components such as pump, fan and sensible cooling unit are able to control. The equilibrium point of heat and mass transfer are the liquid desiccant and inlet air conditions, where, the heat and mass are not transferred between the liquid desiccant and vapor air. By knowing equilibrium point of heat and mass transfer, the suitable optimal desiccant conditions for certain air condition are funded. This present experiment study is investigated the equilibrium point heat and mass transfer in various air and desiccant temperature. The benefit of equilibrium point heat and mass transfer will be helpful in choose and design proper component to optimize electrical energy consumption.

  • PDF

초음속 습공기 유동에서 비정상 공동유동의 진동 (The Unsteady Cavity Flow Oscillation in Supersonic Moisture Air Stream)

  • 신춘식;이종성;김희동
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.341-344
    • /
    • 2008
  • Numerical simulations have been carried out for a supersonic two-dimensional flow over open, rectangular cavities (length-to-depth ratios are L/D = 1.0) in order to investigate the effect of non-equilibrium condensation of moist air on supersonic flows around the cavity for the flow Mach number 1.83 at the cavity entrance. In the present computational investigation, a condensing flow was produced by an expansion of moist air in a Laval nozzle. The results obtained showed that in the case with non-equilibrium condensation for L/D = 1.0, amplitudes of oscillation in the cavity became smaller than those without the non-equilibrium condensation. Furthermore, the occurrence of the non-equilibrium condensation reduced the peaks of power spectrum density and the frequency of the flow field oscillation increased in comparison with the case of $S_0$ = 0.

  • PDF

유기염소계 살충제의 대기-토양간 분배 (Distribution between Air-Soil Concentration of Organochlorine Pesticides)

  • 최민규;천만영
    • Environmental Analysis Health and Toxicology
    • /
    • 제22권4호
    • /
    • pp.299-304
    • /
    • 2007
  • This paper was studied to investigate the equilibrium state between organochlorine pesticides (OCPs) concentration of air and soil, and to know whether soil is a secondary pollution source of OCPs in air or not. The OCPs concentration of air ($C_{air}$) and soil ($C_{soil}$) is not related to molecular weight, vapor pressure ($P_L$) and octanol-air partition coefficient ($K_{oa}$). The slope of the regression line between soil-air partition coefficient ($K_{sa}$) and scavenging coefficient ($C_{soil}/C_{air}$) was 0.2952, which the OCPs concentration between air and soil did not reached to the equilibrium state. The soil/air fugacity quotients ($f_{soil}/f_{air}$) of p, p'-DDT/DDD/DDE and ${\beta}-HCH\;(0.30{\sim}0.67$), which is smaller than 1, means the deposit of OCPs from air to soil. However, $f_{soil}/f_{air}$ of heptachlor, heptachlor epoxide, ${\alpha}/{\gamma}-chlordane$, trans-nonachlor, endosulfan sulfate and ${\alpha}/{\gamma}-HCH\;(1.90{\sim}73.25)$, which is greater than 1, means that soil is secondary pollution source of OCPs in air.

에어로졸 중화기의 나노 입자 하전 특성 (Nano Particle Charging Characteristics of Aerosol Charge Neutralizers)

  • 지준호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제27권10호
    • /
    • pp.1489-1497
    • /
    • 2003
  • Aerosol charge neutralizers with various radioactive sources have been used to apply an equilibrium charge distribution to aerosols of unknown charge distribution. However, the performance of aerosol charge neutralizers is not well known, especially for highly charged particles. Measurements of highly charged particles are needed in air cleaning devices, e.g. electrostatic precipitator, bag filter with a pre-charger, and electrical cyclone. In this study, the particle charging characteristics of two different aerosol charge neutralizers were experimentally investigated for singly charged monodisperse particles and highly charged polydisperse particles. One has radioactive source of $^{85}$ Kr (beta source, 2 mCi) and the other has $^{210}$ Po (alpha source, 0,5 mCi). The air flow rate passing through each aerosol charge neutralizer was changed from 0.2 to 2.5 L/min. The results show that the charge distribution of singly charged monodisperse particles passing through the $^{85}$ Kr aerosol charge neutralizer is well agreed with the Boltzmann equilibrium charge distribution at an air flow rate of 0.3 L/min, However, it deviates from the equilibrium charge distribution when the air flow rates are 0.6, 1,0, and 1,5 L/min, On the other hands, the effect of air flow rate is insignificant for the $^{210}$ Po aerosol charge neutralizer. The non-equilibrium character in charge distribution of highly charged polydisperse particles passing through the $^{85}$ Kr aerosol charge neutralizer greatly depends on the air flow rate, however it is insensitive to the air flow rate for the $^{210}$ Po aerosol charge neutralizer.

보리의 상온 통풍건조 시뮬레이션(I) -실험치와 예측치의 비교- (Simulation of Natural Air Drying of Barley -Comparison of Experimental and Simulated Results-)

  • 금동혁;이선덕
    • Journal of Biosystems Engineering
    • /
    • 제15권1호
    • /
    • pp.44-51
    • /
    • 1990
  • Four models in current use for cereal grain drying, equilibrium model, Morey model, partial differential equation model and simplified partial differential equation model, were modified to be suitable for natural air drying of barley. The predicted by the four models and experimental results were compared. Three models except equilibrium model predicted moisture comtent and grain temperature very well. But equilibrium model overpredicted moisture content and grain temperature of bottom layer. The degree of prediction of the four models for relative humidities of exhaust air didn't differ much from one another and equally the four models predicted relative humidity statisfatorily. Morey model took much shorter computing time than any other models. Therefore, considering the degree of prediction and computing time Morey model was the most suitable for natural air drying of barley.

  • PDF

HFC125/134a계의 기-액상평형에 관한 연구 (Investigation of vapor-liquid equilibrium of HFC125/134a system)

  • 김창년;박영무
    • 설비공학논문집
    • /
    • 제10권2호
    • /
    • pp.238-250
    • /
    • 1998
  • Vapor-liquid equilibrium apparatus is designed and set up. The vapor-liquid equilibrium data of the binary system HFC125/134a are measured in the range between 268.15 and 283.15K at five compositions. Twenty-five equilibrium data are obtained. To verify consistency of these data, they are tested for thermodynamic consistency. Based upon the present data, the binary interaction parameter for CSD and RKS equation of state is calculated at five isotherms and comparison with the data in the open literatures is made. Results of Nagel and Bier are in very good agreements with those from this study within 0.32∼1.11% for bubble point pressure and -0.66∼0.18% for vapor mole fraction.

  • PDF

HFC32/134a 계의 기-액상평형에 관한 연구 (Investigation of vapor-liquid equilibrium of HFC32/134a system)

  • 김창년;박영무;이병권;안병성
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.527-535
    • /
    • 1997
  • Vapor-liquid equilibrium apparatus is designed and set up. The vapor-liquid equilibrium data of the binary system HFC32/134a are measured in the range between 258.15 and 283.15K at compositions of 0.2, 0.4, 0.6 and 0.8 mole fraction of HFC32. Twenty-two equilibrium data are obtained. Based upon the present data, the binary interaction parameter for Carnahan-Starling-De Santis equation of state is calculated. Temperature range of data is extended to 313.04K using the data in the open literatures. Interaction parameters are determined at nine isotherms.

  • PDF

HFC125+Propane 혼합냉매의 기-액 평형에 관한 실험적 연구 (An Experimental Study of Vapor-Liquid Equilibrium for HFC12S+Propane Refrigerant Mixtures)

  • 강준원;박영무;유재석;이종화
    • 설비공학논문집
    • /
    • 제15권7호
    • /
    • pp.563-571
    • /
    • 2003
  • The forty vapor-liquid equilibrium data of the binary system, HFC125+Propane, were measured between 273.15 and 313.15 K at 10 K interval and the composition range 0.2∼0.75, respectively. Experiments were performed in a circulation type apparatus in which the vapor phase was forced through the liquid phase. The composition at equilibrium were mea-sured by gas chromatography, and its response was calibrated using gravimetrically prepared mixtures. Vapor-liquid equilibrium data were calculated by using CSD equation of state and compared with the experimental data.