• Title/Summary/Keyword: Equation for frost penetration depth

Search Result 4, Processing Time 0.016 seconds

Analysis of Penetration Depths in Pavement in Korea (포장도로에서의 동결심도 조사분석)

  • Kim, Young-Chin;Hong, Seung-Seo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.475-482
    • /
    • 2005
  • Many public facilities including roadway, railway, and embedded pipe lines in this country have been damaged by the repeated freezing and thawing of the soil during winter and spring every year. However, there are only few research results in field of frozen ground in this country. Also, there are no the formulation of the reasonable equation for frost penetration depths and of the criterion for identifing potentially frost-susceptible soil in design manual of pavement yet. Through this study it is anticipated to asses the frost action problem in roadway, railway, and water suppply lines and to establish the design criterion about pavement in seasonal cold region.

  • PDF

The Relationship Between Freezing Index and Frost Penetration Depths in Korea National Road (동결지수와 전국 포장국도에서 실측한 동결깊이의 관계)

  • Kim, Youngchin;Hong, Seungseo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.4
    • /
    • pp.15-24
    • /
    • 2009
  • Korea is known to have seasonal frost during winter and the effect of low temperatures and water may cause a weakening of pavements. For that reason, frost protection layers have been constructed in pavements to avoid damage caused by frost action. The practies established in USA and Japan have been adopted as anti-frost design methods in Korea. However, the characteristics of Korean soils are different. Additionally, there is no formulation of a reasonable equation for frost penetration depth and the criterion to identify potentially frost-susceptible soils in present pavement design manuals in Korea. Therefore, adequate pavement design procedures in seasonal frost areas, as well as construction and maintenance practices are required. In this paper, frost penetration depths along national roads in Korea were measured and analyzed over several years. The frost penetration depth was analyzed with respect to the provinces of Korea and sunny/ shaded areas. Additionally, measurement results were compared to the formula of the US Army Corps of Engineers and Ifukube in Japan.

  • PDF

The Control of the Ground Frost Heave by Using the Scrap Tire (폐타이어를 이용한 지반동상 방지)

  • 김영진;강병희
    • Geotechnical Engineering
    • /
    • v.14 no.1
    • /
    • pp.49-58
    • /
    • 1998
  • It was investigated whether the scrap tire can be recycled as a construction material for controlling the frost heave of the ground. Some frost heave tests and a frost penetration depth test in the laboratory were performed on the weathered granite soil mitred with variable amount of scrap tire powder under the atmospheric temperature at -$17^{\circ}$ to find the basic effects of the scrap tire on the control of frost. The frost heave control layer of the crushed stone mixed with scrap tire chips directly below thin subbass in the bituminous pavement was found to be effective for practical use. And the equation for the required thickness of this frost heave control layer with freezing index was suggested.

  • PDF

Computing Procedure of Daily Average Air Temperature using Field Data and Frost Index Calibration for Anti-Frost Heave Layer Design (현장계측 데이터를 이용한 일평균 대기온도 산정방법과 동상방지층 설계를 위한 동결지수 보정)

  • Cho, Myung-Hwan;Kim, Nakseok;Shim, Jaepill
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3D
    • /
    • pp.433-439
    • /
    • 2011
  • The frost depth(frost penetration) is used to install anti-frost heave layers in pavement designs. The freezing index is calculated by an annual accumulated value of multiplying the period of time with temperatures below zero, and the corresponding temperature. Therefore, the DAAT(daily average air temperature) calculation method may play an effect on the FI(freezing index). The Weather Observatory used to supply 4 average air temperatures per day, but currently supplies 8 per day. With this study, we divided the southern part(below FI=$350^{\circ}C{\cdot}day$) of the Korean peninsula into 6 areas according to site conditions(low embankment, embankment-cutting slope, and the cutting slope) and established a field measurement system for 15 positions to check the effects on the result of FI according to differing DAAT calculation methods. The air temperatures obtained by the field measurement system was used to calculate and compare the FI. As a result, the freezing index calculated based on the $DAAT_4(T_4)$ is normally greater by 3% than the one on $DAAT_8(T_8)$. In addition, the calibration equation for the freezing index using air temperatures was proposed through the research.