• Title/Summary/Keyword: Equal pressure method

Search Result 89, Processing Time 0.03 seconds

The Study on the Sweating Responses of Adult Female according to Garment types (의복형태에 따른 성인여성의 발한반응에 관한 연구)

  • Yeom Hee Gyong;Choi Jeong Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.4 s.44
    • /
    • pp.405-416
    • /
    • 1992
  • This study was performed to investigate correlation between total body weight loss and local sweat rate and to find out any possible method that can estimate total body weight loss judging from local sweat rate. Twelve adult females were kept at 44 $\pm1^{\circ}C$, 50 ${\pm}5\%$ R.H. (1) Physiological responses such as total body weight loss, local sweat rate, rectal temperature, skin temperature, blood pressure and pulse, (2) micro climate inside garment and (3) subjective sensation were examined. Two types of garment such as long-sleeves with long pants (Type I) and half·sleeves with short pants (Type II) were used to observe the effect of garment types on sweating response. Both clothing weight was equal (132$\pm$3 g/$m^{2}$). The results were as follows: 1. Regardless of the different types, total body weight loss was more interrelated with the sweat rate on forehead than any other parts of the body. Except the forehead, different parts of body with different types of garment influenced on body weight loss quite differently. 2. Total body weight loss was more interrelated with the weight gain of garment than the local sweat rate. 3. Under the environment of 44$\pm1^{\circ}C,\;50{\pm}5\%$R.H., body weight loss during 1 hour of subject clothed and silted was 275.2 g/hr and weight loss per body surface area was 178.9 g/$m^{2}/hr$ Garment types have no influences on total body weight loss. 4. Local sweat rate (mg/7.07 $cm^{2}/hr$) was 208.0,191.0, 133.0, 115.0,81 0, 75.1 and 66.3 on scruff, breast, forehead, forearm, thigh, upper arm, leg respectively No evidence has been found that garment types influenced on local sweat rate (p<0.1). 5. No interrelationships between rectal temperature and total body weight loss, local skin temperature and total body weight loss, and local skin temperature and local sweat rate were found. From this study, some possible method that we can estimate total body' weight loss judging from weight loss of garment. But considering the fact that clothing design factor, the physical characteristics of fabric and environmental factor such as humidity and wind velocity should be concerned in weight loss of garment, it should be studied further whether the total body weight loss can be estimated properly from the weight loss of garment. This experiment suggest that different parts of body with different types of garment can influence on body weight loss quite differently. Therefore, in order to get more precise results, more studies under the diversity of garment types should be done in the near future.

  • PDF

A Biomechanical Modeling of Human Pharyngeal Muscular Dysfunction by Using FEM(Finite Element Method) (유한요소법을 이용한 인두의 기능이상에 대한 생체역학적 모델)

  • Kim Sung Jae;Bae Ha Suk;Choi Byeong Cheol;Kim Sung Min
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.6 s.81
    • /
    • pp.515-522
    • /
    • 2003
  • Pharynx is a system transporting foods by peristaltic motion(contraction and expansion movement! into the esophagus and functioning as airway passages. In this study, structural changes of pharyngeal dysfunction are analyzed by biomechanical model using CT and FEM(finite clement method). Loading condition was assumed that equal pressure was loaded sequentially to inside of pharyngeal tissue. In order to analyze the pharyngeal muscular dysfunction by biomechanical model. the pharyngeal dysfunctions was classified into 3 cases. Taking into account the clinical complication by neuromuscular symptoms such as pharyngeal dysfunction after stroke. we assumed that a change of material property is caused by muscular tissue stiffness. A deformation of cross sectional area of the pharynx is analyzed increasing the stiffness $25\%,\;50\%,\;75\%$ in each case on the basis of stress-strain relationship. Based on three-dimensional reconstruction of pharyngeal structure using limited factor - techniques and the optimization procedure by means of inverse dynamic approach. the biomechanical model of the human pharynx is implemented. The results may be used as clinical index illustrating the degree of pharyngeal muscular dysfunction. This study may be used as useful diagnostic model in discovering early deglutitory impediment caused by physiological or pathological pharyngeal dysfunction.

Periodontal Tissue Response Following Different Types of Fixed Retainers in Young Adult Dogs (수종의 고정성 보정장치에 따른 유성견의 치주조직 반응)

  • Jo, Myung-Hun;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.85-95
    • /
    • 2001
  • The purpose of this study was to evaluate the material for fixed type retainer, allowing physiologic tooth movement. and proper remodeling or periodontal tissue during retention period. The Present study was Performed to observe the histologic changes of periodontal tissue after application of different types of fixed type retainer after orthodontic tooth movement in young adult dogs. For this study, 4 young adult dogs were used as a experimental animal and experimental group was divided into three groups : experimental group 1 contained right side maxillayy third incisors and canines, experimental group 2 contained contralateral teeth of same animals, and control group contained mandibular premolars. And each dogs were applied the 4 different types of fixed type retainer to experimental group 1. The experimental teeth were ligated on the Sentalloy closed coil $spring^{\circledR}$(Tomy Co., Japan) from maxillary third incisors and canines and applied orthodontic force at initial 200gm-forced during 1 week. All the experimental animals were sacrificed on the 3rd week after the orthodontic teeth movement and then the specimens were taken, fixed in formalin, embeded in parafin, sectioned $6-8{\mu}m$ in thickness and stained with Hematoxylin-Eosin staining, and Masson's trichrome staining method. Examined under the light microscopy The following results were observed. 1. There were observed that decreased infiltration of giant tells in pressure side and increased the new bone forming in tension side on the specimen of 6-stranded 0.0195' $Respond^{\circledR}$(G&H Co., U.S.A.) group. Periodontal ligament fibers were much compressed or elongated in 3-stranded 0.018', 0.020' $Dentaflex^{\circledR}$(Dentarum Co., Germany), and Superbond $C&B^{\circledR}$(Sun Medical Co., Japan) groups. 2. In experimental group 1, necrotic bone inside the alveolar bone of pressure side, forming of the sharpey's fiber in osteoid tissue, and remodeling of the periodontal ligament were observed in all animals. 3. In experimental group 2, it was observed that the amount of bone resorption was equal or decreased in pressure side, and increased new bone forming and significantly decreased infiltration of giant cell than the experimental group 1. By this results, it considered that 6-stranded $Respond^{\circledR}$(G&H Co., U.S.A.) wire was the most useful material allowing early periodontal tissue remodeling.

  • PDF

A Study on Buckling Characteristics of 2-way Grid Single-Layer Domes Considering Rigidity-Effect of Roofing Covering Materials (지붕마감재 강성효과를 고려한 2방향 그리드 단층돔의 좌굴특성에 관한 연구)

  • Park, Sang-Hoon;Suk, Chang-Mok;Jung, Hwan-Mok;Kwon, Young-Hwan
    • Journal of Korean Association for Spatial Structures
    • /
    • v.2 no.1 s.3
    • /
    • pp.85-92
    • /
    • 2002
  • Two way grid single-layer domes are of great advantage in fabrication and construction because of the simple fact that they have only four members at each junction. But, from a point of view of mechanics, the rectangular latticed pattern gives rise to a nonuniform rigidity-distribution in the circumferential direction. If the equivalent rigidity is considered in the axial direction of members, the in-plane equivalent shearing rigidity depends only on the in-plane bending rigidity of members and its value is very small in comparison to that of the in-plane equivalent stretching rigidity. It has a tendency to decrease buckling -strength of dome considerably by external force. But it is possible to increase buckling strength by the use of roofing covering materials connected to framework. In a case like this, shearing rigidity of roofing material increases buckling strength of the overall structure and can be designed economically from the viewpoint of practice. Therefore, the purpose of this paper, in Lamella dome and rectangular latticed dome that are a set of 2-way grid dome, is to clarify the effects of roofing covering materials for increasing of buckling strength of overall dome. Analysis method is based on FEM dealing with the geometrically nonlinear deflection problems. The conclusion were given as follows: 1. In case of Lamella domes which have nearly equal rigidity in the direction of circumference, the rigidity of roofing covering materials does not have a great influence on buckling-strength, but in rectangular latticed domes that has a clear periodicity of rigidity, the value of its buckling strength has a tendency to increase considerably with increasing rigidity of roofing covering materials 2. In case of rectangular latticed domes, as rise-span-ratio increases, models which is subjected to pressure -type-uniform loading than vertical-type-uniform loading are higher in the aspects of the increasing rate of buckling- strength according to the rate of shear reinforcement rigidity, but in case of Lamella dome, the condition of loading and rise-span-ratio do not have a great influence on the increasing rate of buckling strength according to the rate of shear reinforcement rigidity.

  • PDF

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF

Development and Animal Tests of Prototype Oxygen Concentrator (국산 산소 농축기의 개발 및 동물실험)

  • 변정욱;성숙환;이태수
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.643-649
    • /
    • 1998
  • Background: For the patient with chronic obstructive pulmonary disease requiring long-term oxygen therapy, oxygen concentrator machines are already widely available for use in home. In this study, we used mongrel dogs as test subjects to compare the functional efficiency and safety of the oxygen concentrator developed by our own research team with those of the imported FORLIFE(TM) machine made by AIRSEP Corp. Method and method: To test mechanical reliability, the concentrations of oxygen delivered were measured after 4 hours of continuous operation. Sixteen mongrel dogs were divided into two equal groups. Mongrel dogs in group A were given oxygen using the imported oxygen concentrator, and those in group B using the machine developed. 5 l/min of oxygen were given, after which vital signs were analyzed, arterial blood gases measured, and blood chemistry tests carried out. Results: After 4 hours of continuous operation, the imported model performed better, giving 98${\pm}$3% oxygen, compared to our model, which gave 91${\pm}$1%. In the animal experiments, oxygen concentrations were measured at the inlet of face mask 1, 2, 3, and 4 hours after continuous administration, and there was no statistically significant difference(repeated measures of analysis of variance p=0.70) between the values of 70.6${\pm}$2.5%, 67.1${\pm}$2.9%, 68.2${\pm}$2.6%, and 64.9${\pm}$3.9% that were measured from group A, and the values of 65.1${\pm}$4.8%, 65.2${\pm}$3.6%, 68.7${\pm}$4.3%, and 66.0${\pm}$5.0% measured from group B. Before oxygen administration, and at 1, 2, 3, and 4 hours after oxygen administration, arterial blood partial pressure of oxygen 87.2${\pm}$2.5 mmHg, 347.4${\pm}$29.3 mmHg, 353.4${\pm}$21.2 mmHg, 343.0${\pm}$28.8 mmHg, and 321.6${\pm}$24.4 mmHg, respectively, were read from group A, which were not statistically different (p=0.24) to the values of 102.5${\pm}$9.6 mmHg, 300.3${\pm}$17.1 mmHg, 321.6${\pm}$23.7 mmHg, 303.4${\pm}$27.4 mmHg, and 273.5${\pm}$25.9 mmHg read from group B. Nonetheless, the arterial blood partial pressure of oxygen values appear to be somewhat higher in dogs that were given oxygen using the imported oxygen concentrator. Conclusions: From these results the prototype oxygen concentrator developed appears to function relatively satisfactorily compared to the imported, established model, but may be criticized for the excessive noise generated and poor long-term endurance or consistency, which need improvement.

  • PDF

Processing of a Good Quality Salted and Semi-dried Mackerel by High Osmotic Pressure Resin Dehydration under Cold Condition (저온삼투압탈수법(低溫渗透壓脫水法)에 의한 고품질(高品質)의 반염건(半鹽乾)고등어 제조(製造))

  • Lee, Jung-Suck;Joo, Dong-Sik;Kim, Jin-Soo;Cho, Soon-Yeong;Lee, Eung-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.468-474
    • /
    • 1993
  • A dehydrating sheet comprises polymeric water absorber. which are packed in a semipermeable cellophane film bag allowing selective permeation of water. This sheet dehydration is quite different from conventional drying method such as sun drying, hot-air blast drying and cold air blast drying in a sense that samples are dried without heat treatment. As a part of the studies to develope a new processing method for effective utilization of dark muscle fishes, the preparation of a good quality salted and semi-dried mackerel by the dehydrating sheet was attempted. The dehydration time for preparation of a salted and semi-dried mackerels containing approximately equal moisture content were revealed $180{\sim}510min$ in conventional drying method and $90{\sim}160min$ in this sheet dehydration, respectively. The moisture and histamine contents of those salted and semi-dried mackerels were $59.4{\sim}62.4%$ and $2.5{\sim}3.6 mg/100g$, respectively. The changes in peroxide value, fatty acid composition, brown pigment formation, myofibrillar protein solubility and Ca-ATPase activity during processing of the salted and semi-dried mackerel prepared by the sheet dehydration were more lower than those of products prepared by conventional drying methods. Therefore, these result showed that the quality of a salted and semi-dried mackerel prepared by the sheet dehydration was imperial to that of those products by conventional drying method.

  • PDF

Comparison of Single-Breath and Intra-Breath Method in Measuring Diffusing Capacity for Carbon Monoxide of the Lung (일산화탄소 폐확산능검사에서 단회호흡법과 호흡내검사법의 비교)

  • Lee, Jae-Ho;Chung, Hee-Soon;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.555-568
    • /
    • 1995
  • Background: It is most physiologic to measure the diffusing capacity of the lung by using oxygen, but it is so difficult to measure partial pressure of oxygen in the capillary blood of the lung that in clinical practice it is measured by using carbon monoxide, and single-breath diffusing capacity method is used most widely. However, since the process of withholding the breath for 10 seconds after inspiration to the total lung capacity is very hard to practice for patients who suffer from cough, dyspnea, etc, the intra-breath lung diffusing capacity method which requires a single exhalation of low-flow rate without such process was devised. In this study, we want to know whether or not there is any significant difference in the diffusing capacity of the lung measured by the single-breath and intra-breath methods, and if any, which factors have any influence. Methods: We chose randomly 73 persons without regarding specific disease, and after conducting 3 times the flow-volume curve test, we selected forced vital capacity(FVC), percent of predicted forced vital capacity, forced expiratory volume within 1 second($FEV_1$), percent of forced expiratory volume within 1 second, the ratio of forced expiratory volume within 1 second against forced vital capacity($FEV_1$/FVC) in test which the sum of FVC and $FEV_1$ is biggest. We measured the diffusing capacity of the lung 3 times in each of the single-breath and intra-breath methods at intervals of 5 minutes, and we evaluated which factors have any influence on the difference of the diffusing capacity of the lung between two methods[the mean values(ml/min/mmHg) of difference between two diffusing capacity measured by two methods] by means of the linear regression method, and obtained the following results: Results: 1) Intra-test reproducibility in the single-breath and intra-breath methods was excellent. 2) There was in general a good correlation between the diffusing capacity of the lung measured by a single-breath method and that measured by the intra-breath method, but there was a significant difference between values measured by both methods($1.01{\pm}0.35ml/min/mmHg$, p<0.01) 3) The difference between the diffusing capacity of the lung measured by both methods was not correlated to FVC, but was correlated to $FEV_1$, percent of $FEV_1$, $FEV_1$/FVC and the gradient of methane concentration which is an indicator of distribution of ventilation, and it was found as a result of the multiple regression test, that the effect of $FEV_1$/FVC was most strong(r=-0.4725, p<0.01) 4) In a graphic view of the difference of diffusing capacity measured by single-breath and intra-breath method and $FEV_1$/FVC, it was found that the former was divided into two groups in section where $FEV_1$/FVC is 50~60%, and that there was no significant difference between two methods in the section where $FEV_1$/FVC is equal or more than 60% ($0.05{\pm}0.24ml/min/mmHg$, p>0.1), but there was significant difference in the section, less than 60%($-4.5{\pm}0.34ml/min/mmHg$, p<0.01). 5. The diffusing capacity of the lung measured by the single-breath and intra-breath method was the same in value($24.3{\pm}0.68ml/min/mmHg$) within the normal range(2%/L) of the methane gas gradient, and there was no difference depending on the measuring method, but if the methane concentration gradients exceed 2%/L, the diffusing capacity of the lung measured by single-breath method became $15.0{\pm}0.44ml/min/mmHg$, and that measured by intra-breath method, $11.9{\pm}0.51ml/min/mmHg$, and there was a significant difference between them(p<0.01). Conclusion: Therefore, in case where $FEV_1$/FVC was less than 60%, the diffusing capacity of the lung measured by intra-breath method represented significantly lower value than that by single-breath method, and it was presumed to be caused largely by a defect of ventilation-distribution, but the possibility could not be excluded that the diffusing capacity of the lung might be overestimated in the single-breath method, or the actual reduction of the diffusing capacity of the lung appeared more sensitively in the intra-breath method.

  • PDF

Effects of Head-Down Tilt$(-6^{\circ})$ on Hemodynamics and Plasma Catecholamine Levels (도립$(-6^{\circ})$이 혈장 Catecholamine 및 심장혈관계에 미치는 영향)

  • Song, Dae-Kyu;Bae, Jae-Hoon;Park, Won-Kyun;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.21 no.2
    • /
    • pp.211-223
    • /
    • 1987
  • Head-down tilt (HDT) at $-6^{\circ}$ has been commonly used as the experimental model in both man and animals to induce the blood shift toward the head or central protion of the body, demonstrating similar physiological effect encountered in the weightlessness in the orbital flight. There are few reports about the physiological response upon the cardiovascular regulatory system or the tolerance to the $(-6^{\circ})$ HDT within a relatively short period less than 1 hour. Therefore, the purpose of this study way to observe the effects of $-6^{\circ}$ HDT on cardiovascular system within 30 minutes and to evaluate early regulatory mechanism for simulated hypogravity. Ten mongrel dogs weighing 8-12 kg were anesthetized with the infusion of 1% ${\alpha}-chloralose$ (100 mg/kg) intravenously, and the postural changes were performed from the supine to the $-6^{\circ}$ head-down Position, then from the head-down to the supine (SUP), and each posture was maintained for 30 minutes. Blood flow $({\dot{Q}})$ through common carotid and femoral arteries were determined by the electromagnetic flowmeter. Mean arterial pressure (MAP), heart rate (HR), respiratory rate , and pH, $P_{O_2}$, $P_{CO_2}$ and hematocrit (Hct) of arterial and venous blood were also measured. The peripheral vascular resistance was calculated by dividing respective MAP values by ${\dot{Q}}$ through both sides of common carotid or femoral arteries. The concentration of plasma epinephrine and norepinephrine was determined by Peuler & Johnson's radioenzymatic method. The results are summarized as follows: In the initial 5 minutes in $-6^{\circ}$ HDT, HR was significantly (p<0.05) increased and MAP slightly decreased. Although ${\dot{Q}}$ and carotid peripheral artery resistance were not significantly changed, ${\dot{Q}}$ through femoral artery was diminished and femoral peripheral artery resistance was elevated. In the SUP, the initial changes of MAP and HR were increased (p<0.05), but those of ${\dot{Q}}$ and peripheral vascular resistance through both common carotid and femoral arteries were not significant. After 10 minutes of each postural change in both HDT and SUP, MAP was maintained almost equal to that of the level of pretilting control. During 60 minutes of both postural changes of HDT and SUP, $P_{O_2}$ and Hct were not changed significantly. However pH tended to increase slowly and $P_{CO_2}$ was gradually decreased. The pH and $P_{CO_2}$ seemed to be related to the increased respiratory rate. Plasma epinephrine concentration was not changed significantly and plasma norepinephrine concentration was slightly decreased in the course of HDT and also at 10 minutes of SUP. However these concentration changes were statistically insignificant. From these results, it may be concluded that the effect of $-6^{\circ}$ HDT for 30 minutes on the cardiovascular system and plasma catecholamine levels of the dog is minimum and it is suggestive that the cardiovascular regulatory mechanism, possibly mediated by so called gravity receptors including baroreceptor and volume receptor, has been properly and adequately operated.

  • PDF