• Title/Summary/Keyword: Equal Load

Search Result 348, Processing Time 0.027 seconds

A simple approach for quality evaluation of non-slender, cast-in-place piles

  • Zhang, Ray Ruichong
    • Smart Structures and Systems
    • /
    • 제4권1호
    • /
    • pp.1-17
    • /
    • 2008
  • This study proposes a conceptual framework of in-situ vibration tests and analyses for quality appraisal of non-slender, cast-in-place piles with irregular cross-section configuration. It evaluates a frequency index from vibration recordings to a series of impulse loadings that is related to total soil-resistance forces around a pile, so as to assess if the pile achieves the design requirement in terms of bearing capacity. In particular, in-situ pile-vibration tests in sequential are carried out, in which dropping a weight from different heights generates series impulse loadings with low-to-high amplitudes. The high-amplitude impulse is designed in way that the load will generate equivalent static load that is equal to or larger than the designed bearing capacity of the pile. This study then uses empirical mode decomposition and Hilbert spectral analysis for processing the nonstationary, short-period recordings, so as to single out with accuracy the frequency index. Comparison of the frequency indices identified from the recordings to the series loadings with the design-based one would tell if the total soil resistance force remains linear or nonlinear and subsequently for the quality appraisal of the pile. As an example, this study investigates six data sets collected from the in-situ tests of two piles in Taipu water pump project, Jiangshu Province of China. It concludes that the two piles have the actual axial load capacity higher than the designed bearing capacity. The true bearing capacity of the piles under investigation can be estimated with accuracy if the amplitude of impact loadings is further increased and the analyses are calibrated with the static testing results.

호남고속철도 동적 안정성 요구 조건을 고려한 강합성 거더교의 변수 연구 (Parametric Study on Steel composite Girder bridges for HONAM High-Speed Railway Considering Criteria Requirement of Dynamic Response)

  • 조선규;정한욱;김성일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1370-1378
    • /
    • 2007
  • 고속철도 교량은 고속주행 열차의 차축 주기하중 효과와 교량 고유의 동적특성에 의한 동적 증폭 효과로 인하여 구조물의 안전성에 영향을 받는다. 그리고 교량의 과도한 변형으로 인하여 차륜과 레일의 접촉력 감소, 궤도틀림 등의 윤중 변동이 일어나 열차의 주행안전성 및 승차감을 저해할 수 있다. 이러한 궤도 안전성을 확보하기 위하여 동적거동에 대한 교량상판수준의 수직가속도 제한, 차륜-레일간의 접촉과 열차주행 안전성 확보를 위한 상판 면틀림 제한, 단부 회전각 변위 제한, 차량하중에 의한 교량의 수직 처짐 제한을 반드시 만족시켜야 하며, 필수적으로 공진에 대한 검토도 이루어져야 한다. 신설되는 호남고속철도에서는 기존의 경부고속철도와 다른 콘크리트 도상을 적용하고, 궤도간격, 설계열차하중 등이 변경되어 적용되므로 새로운 동적안정성 요구조건을 적용하게 된다. 본 연구에서는 콘크리트교량에 비해 진동특성이 취약한 것으로 알려진 강합성 거더 고속철도 교량의 동적거동 분석을 수행하였다.

  • PDF

New constitutive models for non linear analysis of high strength fibrous reinforced concrete slabs

  • Yaseen, Ahmed Asaad;Abdul-Razzak, Ayad A.
    • Structural Engineering and Mechanics
    • /
    • 제82권1호
    • /
    • pp.121-131
    • /
    • 2022
  • The main goal of this study is to prepare a program for analyzing High Strength Steel Fibrous Reinforced Concrete (HSSFRC) slabs and predict the response and strength of the slab instead of preparing a prototype and testing it in the laboratory. For this purpose, new equations are proposed to represent the material properties of High Strength Steel Fibrous Reinforced Concrete. The proposed equations obtained from performing regression analysis on many experimental results using statistical programs. The finite element method is adopted for non-linear analysis of the slabs. The eight-node "Serendipity element" (3 DoF) is chosen to represent the concrete. The layered approach is adopted for concrete elements and the steel reinforcement is represented by a smeared layer. The compression properties of the concrete are modeled by a work hardening plasticity approach and the yield condition is determined depending on the first two stress invariants. A tensile strength criterion is adopted in order to estimate the cracks propagation. many experimental results for testing slabs are compared with the numerical results of the present study and a good agreement is achieved regarding load-deflection curves and crack pattern. The response of the load deflection curve is slightly stiff at the beginning because the creep effect is not considered in this study and for assuming perfect bond between the steel reinforcement and the concrete, however, a great agreement is achieved between the ultimate load from the present study and experimental results. For the models of the tension stiffening and cracked shear modulus, the value of Bg and Bt (Where Bg and Bt are the curvature factor for the cracked shear modulus and tension stiffening models respectively) equal to 0.005 give good results compared with experimental result.

Assessment of the characteristics of ferro-geopolymer composite box beams under flexure

  • Dharmar Sakkarai;Nagan Soundarapandian
    • Advances in concrete construction
    • /
    • 제15권4호
    • /
    • pp.251-267
    • /
    • 2023
  • In this paper, an experimental investigation is carried out to assess the inherent self-compacting properties of geopolymer mortar and its impact on flexural strength of thin-walled ferro-geopolymer box beam. The inherent self-compacting properties of the optimal mix of normal geopolymer mortar was studied and compared with self-compacting cement mortar. To assess the flexural strength of box beams, a total of 3 box beams of size 1500 mm × 200 mm × 150 mm consisting of one ferro-cement box beam having a wall thickness of 40 mm utilizing self-compacting cement mortar and two ferro-geopolymer box beams with geopolymer mortar by varying the wall thickness between 40 mm and 50 mm were moulded. The ferro-cement box beam was cured in water and ferro-geopolymer box beams were cured in heat chamber at 75℃ - 80℃ for 24 hours. After curing, the specimens are subjected to flexural testing by applying load at one-third points. The result shows that the ultimate load carrying capacity of ferro-geopolymer and ferro-cement box beams are almost equal. In addition, the stiffness of the ferro-geoploymer box beam is reduced by 18.50% when compared to ferro-cement box beam. Simultaneously, the ductility index and energy absorption capacity are increased by 88.24% and 30.15%, respectively. It is also observed that the load carrying capacity and stiffness of ferro-geopolymer box beams decreases when the wall thickness is increased. At the same time, the ductility and energy absorption capacity increased by 17.50% and 8.25%, respectively. Moreover, all of the examined beams displayed a shear failure pattern.

Behavior of lightweight aggregate concrete voided slabs

  • Adel A. Al-Azzawi;Ali O, AL-Khaleel
    • Computers and Concrete
    • /
    • 제32권4호
    • /
    • pp.351-363
    • /
    • 2023
  • Reducing the self-weight of reinforced concrete structures problem is discussed in this paper by using two types of self-weight reduction, the first is by using lightweight coarse aggregate (crushed brick) and the second is by using styropor block. Experimental and Numerical studies are conducted on (LWAC) lightweight aggregate reinforced concrete slabs, having styropor blocks with various sizes of blocks and the ratio of shear span to the effective depth (a/d). The experimental part included testing eleven lightweight concrete one-way simply supported slabs, comprising three as reference slabs (solid slabs) and eight as styropor block slabs (SBS) with a total reduction in cross-sectional area of (43.3% and 49.7%) were considered. The holes were formed by placing styropor at the ineffective concrete zones in resisting the tensile stresses. The length, width, and thickness of specimen dimensions were 1.1 m, 0.6 m, and 0.12 m respectively, except one specimen had a depth of 85 mm (which has a cross-sectional area equal to styropor block slab with a weight reduction of 49.7%). Two shear spans to effective depth ratios (a/d) of (3.125) for load case (A) and (a/d) of (2) for load case (B), (two-line monotonic loads) are considered. The test results showed under loading cases A and B (using minimum shear reinforcement and the reduction in cross-sectional area of styropor block slab by 29.1%) caused an increase in strength capacity by 60.4% and 54.6 % compared to the lightweight reference slab. Also, the best percentage of reduction in cross-sectional area is found to be 49.7%. Numerically, the computer program named (ANSYS) was used to study the behavior of these reinforced concrete slabs by using the finite element method. The results show acceptable agreement with the experimental test results. The average difference between experimental and numerical results is found to be (11.06%) in ultimate strength and (5.33%) in ultimate deflection.

Triplet Camera 광학계의 설계와 수차 분석 (Design and Aberration Analysis of Triplet Camera Optical System)

  • 김종태
    • 한국인쇄학회지
    • /
    • 제16권2호
    • /
    • pp.1-10
    • /
    • 1998
  • Even if some kinds of software for halftoning such as raster image process program are on the market, most of them couldn`t apply to the new laser gravure cylinder making machine because they are closed the source program. In order to develop new laser gravure engraving machine, we were investigated new suitable halftoning software based on the mapping and equal density expansion algorithm that we are mapped. As the results of actual practice with Microsoft Visiul C++2.0 in 133Khz 64M ram IBM personal computer, we found that the new software for halftone generation for laser gravure engraving machine are available in new machine, and easily load and processing the graphic image for gravure hardcopy.

  • PDF

Nonlinear analysis based optimal design of double-layer grids using enhanced colliding bodies optimization method

  • Kaveh, A.;Moradveisi, M.
    • Structural Engineering and Mechanics
    • /
    • 제58권3호
    • /
    • pp.555-576
    • /
    • 2016
  • In this paper an efficient approach is introduced for design and analysis of double-layer grids including both geometrical and material nonlinearities, while the results are compared with those considering material nonlinearity. Optimum design procedure based on Enhanced Colliding Bodies Optimization method (ECBO) is applied to optimal design of two commonly used configurations of double-layer grids. Two ranges of spans as small and big sizes with certain bays of equal length in two directions are considered for each type of square grids. ECBO algorithm obtains minimum weight grid through appropriate selection of tube sections available in AISC Load and Resistance Factor Design (LRFD). Strength constraints of AISC-LRFD specifications and displacement constraints are imposed on these grids.

균일혼합기 가솔린 직분사 엔진의 다중 영역 유사차원 해석을 통한 배기 및 노킹 예측 (Quasidimensional Simulation with Multi-zone Combustion Model for Homogeneous GDI Engine Emissions and Knocking)

  • 이재서;허강열;권혁모;박재인
    • 한국연소학회지
    • /
    • 제18권1호
    • /
    • pp.7-12
    • /
    • 2013
  • A quasidimensional program is developed for a four stroke cycle homogeneous GDI (Gasoline Direct Injection) engine. It includes models for spray, burning rate and chemistry to predict knock and emissions. With early injection a homogeneous GDI engine goes through spark ignited, turbulent premixed combustion as in PFI (Port Fuel Injection) engines. The cylinder charge is divided into unburned and burned zone with the latter divided into multiple zones of equal mass to resolve temperature stratification. Validation is performed against measured pressure traces, NOx and CO emissions at different load and RPM conditions. Comparison is made between an empirical knock model and predictions by the chemistry model in this work.

Comparative Study on 220V AC Feed System and 300V DC Feed System for Internet Data Centers

  • Kim, Hyo-Sung
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.157-163
    • /
    • 2012
  • Internet Data Centers (IDCs), which are essential facilities in the modern IT industry, typically have scores of MW of concentrated electric loads. The provision of an Uninterruptible Power Supply (UPS) is necessary for the power feed system of IDCs owing to the need for stable power. Thus, conventional IDC AC power feed systems have three cascaded power conversion stages, (AC-DC), (DC-AC), and (AC-DC), resulting in a very low conversion efficiency. In comparison, DC power feed systems require only a single power conversion stage (AC-DC) to supply AC main power to DC server loads, resulting in comparatively high conversion efficiency and reliability [4-11]. This paper compares the efficiencies of a 220V AC power feed system with those of a 300V DC power feed system under equal load conditions, as established by the Mok-Dong IDC of Korea Telecom Co. Ltd. (KT). Experimental results show that the total operation efficiency of the 300V DC power feed system is approximately 15% higher than that of the 220V AC power feed system.

입수 충격 하중에 관한 실험적 연구 (The Water Entry Fluid Load Experimental Analysis)

  • 정두진;이희성;권순홍;송기종;정병훈
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 추계학술대회 논문집
    • /
    • pp.183-186
    • /
    • 2003
  • This paper presents the results of slamming experiment using air pressure cylinder to increase the repeatability of the experiment. When it comes to the slamming experiment, the traditional way of doing it has been the free fall experiment. By adopting air pressure cylinder almost equal peak pressures were obtained with that of free fall experiment. Jet takes place when the wedge enters water. Slamming doesn't take place when Dead rise angle is more then 20 degrees.

  • PDF