• Title/Summary/Keyword: Environmental noise standard

Search Result 140, Processing Time 0.02 seconds

A study on Traffic Noise control by the Environmental facilities around Roadway (도로연변 환경시설에 의한 교통소음 저감방안에 관한 연구)

  • Sul Jeung Min;Chung Yong
    • Journal of environmental and Sanitary engineering
    • /
    • v.3 no.2 s.5
    • /
    • pp.43-60
    • /
    • 1988
  • This study was carried out to determine traffic noise level and analyze noise reduction effects of various sound protection facilities in the area of Seoul, Inch'on, Songchoo and Seoul- Busan Expressway from March to Octover, 1987. The results were as follows; 1. As compared with the environmental standards and the traffic noise level in heavy noise areas, traffic noise levels observed were shown in higher than environmental standards. The noise levels in Seoul were determined at 12.8-18.2 dB(A) in daytime and 19.0-26.9 dB (A) in nighttime. And incase of inch'on, it were 6.7-9.6 dB(A) in daytime, 7.9-18.9 dB(A) in nighttime, respectively. 2. The environmental noise level observed in the backside of protection facilities, such as apartment, soundproof barrier and houses, which were constructed in paralled to the road was lower about 3-5 dB(A) than perpendicular to theroad. Noise recuction effect of upper stairs in apartment was higher than lower stairs. 3. The predicted noise level obtained from the equation $({\triangle}L\;=\; -10\;log\;(^{I'1}/Ii)\;was\;\pm\;1dB$ (A) and the correlation coefficient (r) was 0.923. 4. The noise reduction effect in backside of apartment was measured at on sites and predicted by total noise loss equation. The predicted noise level was 60.9 dB(A) and the measured level was 60.6 dB(A), respectively. 5. The narrow width landscape less than 10m width was almost no effect for the protection of traffic noise. According to the synthesis of the above results, the noise level of the road was exceeding mostly the environmental standard in the heavy traffic areas. The counterplan should be set as well. The insulation of noise protection facilities were effective by the location with near distance from the road edge. The reduction effect of double window in apartment was represented so much. The prediction model could be applied to estimate the noise levels in the roadside as well as the effectiveness for the noise protection facilities.

  • PDF

A Case Study on the Teaching Method of the "Noise" Unit (소음 단원의 교수-학습 모형 개발 및 적용에 관한 현장 연구)

  • 송호열
    • Hwankyungkyoyuk
    • /
    • v.15 no.2
    • /
    • pp.14-29
    • /
    • 2002
  • The environment of the world becomes deteriorated rapidly as the result of the development of technology, the increase of the standard of living, and the growth of population. These circumstances called for environmental education in Korea, creating an environment course in the middle and high school in 1995. Despite the increasing importance of environmental education, however, the situation has not developed in its favor because of the current system of the university entrance examination. The school has failed to develop the curriculum of environmental education in the secondary education. This paper solves this problem internally in terms of the improvement of the contents, organization, teaching method (role-playing game), and teaching materials of environmental education, with a case study of the “noise” unit in 10th grade. This case study expects to change the attitude toward noise, increase the interest and knowledge in environment, and lead to responsible environmental behavior.

  • PDF

Evaluation on Noise Level of One-Room Type Multi-Family Housing Around Campus (대학주변 원룸형 다가구주택의 소음측정평가)

  • Choi, Yoon-Jung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.95-100
    • /
    • 2003
  • The purpose of this study is to evaluate the noise environment of one-room type multi-family housing around the campus. The field measurements on equivalent noise level of indoor and outdoor were carried out in 6 subject house units during the 26th${\sim}$28th of November 2002. The results are as follows. 1) Outdoor noise levels of 6 subject buildings were distributed 52.8${\sim}$65.3dB(A) and were inappropriate to the standard for environmental noise, 55dB(A). 2) Indoor noise level of 6 subject house units were measured 27.5${\sim}$63.5dB(A). These values were higher than the indoor noise standard (40dB(A)) except subject house D(average 37.6dB(A)). 3) It was found that the differences of indoor noise levels between subject house units were caused by resident's living factor, characteristics of window, and existence of balcony.

  • PDF

Characteristics of Construction Machinery Noise and Vibration (건설기계류 소음·진동 특성)

  • Kang, Daejoon;Lee, W.S.;Lee, J.W.;Hong, J.K.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.6 s.99
    • /
    • pp.645-651
    • /
    • 2005
  • The construction noise Is one of the main causes of environmental impact. The complaints about it have been increasing every year. In order to reduce construction machinery noise, the product noise labeling for construction machinery has been recommended since 1 February 1996 and In the near future the government will convert the recommended product noise labeling to the mandatory product noise labeling for high noise construction machinery. Therefore, we investigated the noise and vibration level of 302 construction machines in construction work sites. This paper presents the basic data that will be used for setting the standard of construction machinery noise and predicting the noise level near construction work sites in environmental Impact assessment.

Implementation of Quad Variable Rates ADPCM Speech CODEC on C6000 DSP considering the Environmental Noise (배경잡음을 고려한 4배 가변 압축률을 갖는 ADPCM의 C6000 DSP 실시간 구현)

  • Kim Dae-Sung;Han Kyong-ho
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.727-729
    • /
    • 2002
  • In this paper, we proposed quad variable rates ADPCM coding method and its implementation on C6000 DSP, which is modified from the standard ADPCM of ITU G.726 for speech quality improvement considering the environmental noise Four coding rates, 16Kbps, 24Kbps, 32Kbps and 40Kbps are used for speech window samples and the rate decision threshold is decided by the environmental noise level. The object of the proposed method is to reduce the coding rate while retaining the speech quality and the speech quality is considerably close to 40Kbps single rate coder with the coding rate close to 16Kbps single rate coder under the environmental noise. The environmental noise level affects the coding rate and the noise level is calculated per every speech window samples. At high noise level, more samples are coded at higher rates to enhance the quality, but at low noise level, only the big speech signals are coded at higher rates and more speech samples are coded at lower coding rates to reduce the coding rates. The influence of the noise on tile speech signal is considerably high for small signals and the small signal has the higher ZCR (zero crossing rate). The method is simulated in PC and to be implemented on C6000 floating point DSP board in real time operations.

  • PDF

An Analysis on Traffic Noise at Pusan Shopping Districts by Leq, Lr, TNI Ratings (Leq, Lr, TNI 평가법에 의한 부산시 주요 상가변의 소음도 분석)

  • 한돈희
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.1
    • /
    • pp.9-19
    • /
    • 1990
  • To evaluate the degree of traffic noise at the main shopping districts, 30 sites, in Pusan and produce the basic data of traffic noise counterplan, this research was conducted. Noise rating methods utilized were Leq(equivalent continuous sound level), Lr (rating sound level) and TNI (traffic noise index). As the results, all sites passed beyond Korean Environmental Noise Standard 70 dB(A) in Leq and 46.7% sites fell under 'widespread complaints'step, 40.0% 'threat of community' action'step, 13.3% 'vigorous community action'step by Lr ratings, and 30.0% sites were over acceptable TNI criteria of 74. Therefore, traffic noise at Pusan shopping districts was very severe.

  • PDF

A Study on Estimation of Noise Damage caused by Rupture of Butane-can(volume : 34g)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Choi, Seong-Joo;Lee, Jong-Rark;Lim, Dong-Yeon
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.13-17
    • /
    • 2007
  • It is very insecure to treat a butane can for cooking out of door. The human injury from the accidents of butane cans has been getting increased 1.5 times yearly since 2003. In this context, the Institute of Gas Technology Training in Korea Gas Safety Corporation carries out explosion experiment to make trainees to take all possible measures to ensure safe management of gas in the field by fully recognizing the hazards of gas explosion accidents. This study intends to examine the influence of such explosion experiments on the trainees witnessing nearby. The GEN exposed to the active students participating in the experiment away from 25 meters from the explosion site was 57.94 dB and the GEN to the passive students not participating away from 50 meters was 51.92 dB. According to Weber-Fechner's law for the lower value than 65 dB which is the environmental standard, it is safe from the place 15 meter far from the explosion place. The environmental standard of offices is 50 dB, and it is lower than the environmental standard if the office is 65 meter far from the explosion place.

  • PDF

Suggestion of assessment height for noise measurement according to the vertical radiation characteristics of railway noise (철도소음의 높이별 방사특성을 고려한 수음 평가 위치 제안)

  • Cho, Jun-Ho;Jang, Kang-Seok
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.1
    • /
    • pp.29-37
    • /
    • 2014
  • Exact and precise noise measurement is the basis for the reduction measure R&D, impact assessment and prediction modeling for railway noise. In this study, research trend as well as national and international noise measurement standard are investigated. For the estimation of vertical radiation characteristics of railway noise, specially devised zig was used. From the noise measurement and analysis, exact noise height radiated from the railway was characterized. The obtained results will be used for the suggestion of the height of microphone position of railway noise measurements.

A Study on the Sound Proof Efficiency of Windows for Road Traffic Noise (도로변 건물의 창문과 방음효과에 대한 평가)

  • 박성배;신재영;정종흡;정일현
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.4
    • /
    • pp.56-62
    • /
    • 1995
  • Recently, the traffic noise around residences and schools has become a serious social problem with the increase of the amount of transportation. This study was performed to investigate the sound proof efficiency of windows for traffic noise. The results were as follows 1) The traffic noise in 19 sites among 22 sampling sites was higher value than 65 dB(A) being roadside environment standard level in the daytime when all windows were opened, while the noise in 22 sampling sites was transmitted below standard level when all windows were closed. 2) The transmission loss of sound level at single window and double windows were 10~25 dB(A) and 11~29 dB(A) respectively. 3) The transmission loss of sound level at sampled school with sound proof pannel was 7~8 dB (A), which was lower 2~7 dB(A) than the theoretical value of the influence assessment . 4) The construction cost of double windows was lower 28% even if include the cost of setting up air conditioner for the summer season and the power consuming cost for its operation than that of sound proof pannel for traffic noise. 5) The effect of transmission loss of windows was more influenced by airtight than materials of windows.

  • PDF

Hourly Environmental Pollution (Air Pollution and Noise) Mapping Method by the Traffic Volume Change (시간별 교통량 변화에 따른 환경오염지도(대기 및 소음) 구축방안에 관한 연구)

  • Cho, Dong-Myung;Kwon, Woo-Taeg;Na, Young
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.6
    • /
    • pp.485-494
    • /
    • 2007
  • Air pollution and traffic noise from roads distributed near residential area has been a major social problem. In this study, an environmental pollution map for a residential area of Shihung-city was made by an expectation model based on hourly traffic volume change. Using the result from the model, a plan to reduce population in the residential area was established. The result of the modelling is summarized as follows: 1. At peak traffic hours (18 o'clock), 301-500 degree in hazardous and $d_{25}$ degree (25% of the residents are suffering extremely from the noise) in noise pollution were predicted in Jeongwang Main Road in Shihung city. 2. The calculated critical pollutant standard index, PSI showed the air pollution level, especially PM-10 high enough to require re-entrainment. 3. It was expected air pollution would extensively extend over the area distribution of each degree. However, noise pollution problem was limited to the area near roads.