• Title/Summary/Keyword: Environmental criteria

Search Result 2,380, Processing Time 0.026 seconds

A Study on the Remodeling of General Hospitals in Consideration of Healing Environmental Elements - focused on the case of a hospital - (치유환경 요소를 고려한 종합병원의 리모델링 사례연구 - A병원 사례를 중심으로 -)

  • Lim, Jin Woo;Park, Jae Seung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.10 no.1
    • /
    • pp.7-17
    • /
    • 2004
  • This study aims to propose planning guides and general suggestions in the remodeling of general hospitals. Among the many goals in the hospital remodeling, this study focuses on the enhancing the 'healing environment' to existing building. Accordingly this study analyzes design criteria for 'healing environment' through the case study of 'A' hospital which has been remodeled recently, and compares those criteria with actual execution.

  • PDF

A Study on Management of Seafood Wastewater Treatment Facility using Submerged MBR (침지식 MBR을 이용한 수산물 폐수처리장 운영에 관한 연구)

  • Choi, Yong-Bum;Lee, Hae-Seung;Han, Dong-Joon;Kwon, Jae-Hyouk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7227-7236
    • /
    • 2015
  • The survey revealed that, due to the discharge characteristics of seafood wastewater, irregular inflow loads were caused, making it difficult to treat the wastewater safely. It is crucial for the operation of pressure and floating tanks for the treatment of high-concentration organic wastewater such as seafood wastewater. The survey of operation factors for the pressure and floating tanks revealed this: A/S ratio 0.05 (design criteria 0.01), the pressurized air pressure 8bar(design criteria 6bar), the pressure tank pressure 6bar (design criteria 4.5bar), and HRT 60sec(design criteria: 10sec). Also, the recirculation rate was changed to over 40%(design criteria: 30%), and the surface load rate was changed to under $13.7m^3/m^2{\cdot}hr$(design criteria: under $17.7m^3/m^2{\cdot}hr$); thus, compared to the initial design criteria, the operation factors were changed according to inflow characteristics, thus enhancing the pressure and floating tank performance. The survey of inflow load revealed BOD 140.7%, $COD_{Mn}$ 120.32%, and SS 106.3%, compared to the inflow design criteria, as well as T-N 135.5% and T-P173.3%, higher than the design criteria. The survey of the treatment facility annual operation cost revealed high portions in sludge treatment cost(27.7%) and chemicals costs(26.0%), and the sludge treatment cost will likely further increase due to the ban on ocean dumping. The unit cost for the treatment of seafood wastewater was found to be KRW 3,858 per ton, more than 27 times higher than the sewage treatment cost(KRW 142.6/ton), presumably because the seafood wastewater contains high-concentration organic substances and nutritive salts.

Improvement Directions for the G-SEED System from the Resident's Perspective - Focused on Certification Assessment Criteria for Apartment Buildings -

  • Choi, Yeo Jin;Lhee, Sang Choon
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.19-26
    • /
    • 2014
  • The building section is providing immediate causes for global climate change problems since it takes about 50% of carbon emission, 20~50% of waste discharge, 33% of energy consumption, 40% of resource use, and 17% of water consumption. So, many countries over the world have developed and implemented green building certification systems to assess sustainable performances of buildings since the early 1990s. In korea, the green building certification system to induce the diffusion of sustainable buildings was first introduced in 2002 and developed as an improved version of the G-SEED(Green Standard for Energy and Environmental Design) system in 2013 after major revisions of related legislations. This research conducts a survey targeting residents on an apartment building that was certified as green building and examines the importance of assessment criteria on apartment buildings to certify green buildings using the Analytic Hierarchy Process(AHP) method. And it proposes a new direction on certification assessment standards from the resident's prospective. As a result, assessment criteria such as indoor environment, ecological environment, energy & environment pollution, and maintenance management among 7 main ones turned out important on assessing the G-SEED system for apartment buildings, while criteria such as material & resource, water circulation management, and land use & transportation did relatively unimportant.

A Comparative Study on Office Building Criteria between G-SEED and LEED

  • Mok, Seon-Soo;Cho, Dong-Woo;Park, Ah-Reum
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.59-66
    • /
    • 2014
  • G-SEED aims for establishing green environmental building with energy saving and has started for evaluating with multi-residential complex in 2002 by the Ministry of Land, Infrastructure & Transport (MOLIT) and the Ministry of Environment to develop the current 10 building types and new & existing building types to be applied. Since G-SEED has been developed for more than 10 years, the strategy of globalization is needed with constant review itself and comparison between other assessments to understand current situation from the global perspectives. This study draws similarities and differences of G-SEED and LEED criteria by the comparison from re-constructed LEED criteria based on G-SEED. "Energy & Pollution" is the most concerned category in both assessments as the result of analysis on category rates. Next concerns are "Material & Resources", "Indoor Environment" and "Water Management". The unique categories in both criteria are "Ecological Environment" in G-SEED and "Innovation & Design Process" in LEED. The conclusion of this research is that two assessments are organized at different locations and with different strategies for developing green building but there are common concerns such as energy saving, material use, indoor environment. As a result, it is expected to use fundamental data for developing G-SEED for global standard.

Strain-based seismic failure evaluation of coupled dam-reservoir-foundation system

  • Hariri-Ardebili, M.A.;Mirzabozorg, H.;Ghasemi, A.
    • Coupled systems mechanics
    • /
    • v.2 no.1
    • /
    • pp.85-110
    • /
    • 2013
  • Generally, mass concrete structural behavior is governed by the strain components. However, relevant guidelines in dam engineering evaluate the structural behavior of concrete dams using stress-based criteria. In the present study, strain-based criteria are proposed for the first time in a professional manner and their applicability in seismic failure evaluation of an arch dam are investigated. Numerical model of the dam is provided using NSAD-DRI finite element code and the foundation is modeled to be massed using infinite elements at its far-end boundaries. The coupled dam-reservoir-foundation system is solved in Lagrangian-Eulerian domain using Newmark-${\beta}$ time integration method. Seismic performance of the dam is investigated using parameters such as the demand-capacity ratio, the cumulative inelastic duration and the extension of the overstressed/overstrained areas. Real crack profile of the dam based on the damage mechanics approach is compared with those obtained from stress-based and strain-based approaches. It is found that using stress-based criteria leads to conservative results for arch action while seismic safety evaluation using the proposed strain-based criteria leads to conservative cantilever action.

A Study on Improvement of the Assessment Criteria for New and Renewable Energy Facilities in the G-SEED (G-SEED의 신·재생에너지시설 평가기준 개선 연구)

  • Kim, Wan-Young;Tae, Choon-Seob;Shin, U-Cheol;Yu, Chang-Kyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.6
    • /
    • pp.43-50
    • /
    • 2015
  • The G-SEED encourages the installation of new and renewable energy facilities through assessments of the new and renewable energy installation rates. The government also regulates the installation rate of new and renewable energy facilities in the 'Project on new and renewable energy obligation in public installations'. The current criteria concerning the new and renewable energy facilities in the G-SEED are the result of an amendment made in July 2010. As over five years have passed since this amendment, the assessment criteria needs to be reenforced. To improve the current criteria, the calculation results of the installation rate of new and renewable energy facilities in the G-SEED were analyzed and compared to the corresponding calculation results of the 'Project on new and renewable energy obligation in public installations'. And an improved draft for the assessment criteria of the new and renewable energy facilities in the G-SEED was proposed.

A Study on the Determination of Vibration Criteria for Vibration Sensitive Equipments Using Impact Test (충격시험을 이용한 고정밀장비의 진동허용규제치 결정기법에 관한 연구)

  • 이홍기;박해동;김두훈;김사수
    • Journal of KSNVE
    • /
    • v.7 no.2
    • /
    • pp.247-254
    • /
    • 1997
  • In the case of a precision equipment, it requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga class semiconductor wafers. This high technology equipments require very strict environmental vibration standard in proportion to the accuracy of the manufacturing, inspecting devices. The vibration criteria are usually obtained either by the real vibration exciting test on the equipment or by the analytical calculation. This paper proposes a new method to solve this problem at a time. The permissible vibration level to a precision equipment can be easily obtained by analyzing a process of Frequency Response Function. This paper also demonstrates its effectiveness by applying the proposed method to finding the vibration criteria of a Computer Hard Disk Driver by Impact Test.

  • PDF

Environmental Hazardous Assessment on Wood Panel Manufacturing Process (목재판넬 제조공정의 환경위험성평가)

  • Lee, Su-Gil;Lee, Nae-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.13-21
    • /
    • 2007
  • Personal and static sampling for formaldehyde, wood dust and noise monitoring, in accordance to the equipment running on the day, were carried out throughout wood panel manufacturing process. Even though the exposure level of formaldehyde and wood dust were below than exposure criteria, but the personal protective equipment(PPE) for those should be worn to everyone in the process because of its potential characteristics like carcinogenicity. Also a few local air extraction system above the cutting, grinding sections and organic blending room should be required. Most of the exposures of noise exposure were exceeded permitted exposure criteria, in case of Hopper operators, exposed to maximally 94dB(A) as LAeq 8hr, therefore active controls like PPE, monitoring, isolation etc. are necessary. The main sources of noise were caused on compressed air of the machinery, radio sound and operation noise like running machines, conveying, cutting, sawing, moving vehicles, storing and so on. For the comparison of control criteria in each country, the permitted exposure standards for above hazardous materials and noise in Korea, ACGIH and Australia were discussed. We have recognized that the Korean criteria should be discussed urgently to give the right information to employee and modified, if it is necessary.

Reliability analysis and evaluation of LRFD resistance factors for CPT-based design of driven piles

  • Lee, Junhwan;Kim, Minki;Lee, Seung-Hwan
    • Geomechanics and Engineering
    • /
    • v.1 no.1
    • /
    • pp.17-34
    • /
    • 2009
  • There has been growing agreement that geotechnical reliability-based design (RBD) is necessary for establishing more advanced and integrated design system. In this study, resistance factors for LRFD pile design using CPT results were investigated for axially loaded driven piles. In order to address variability in design methodology, different CPT-based methods and load-settlement criteria, popular in practice, were selected and used for evaluation of resistance factors. A total of 32 data sets from 13 test sites were collected from the literature. In order to maintain the statistical consistency of the data sets, the characteristic pile load capacity was introduced in reliability analysis and evaluation of resistance factors. It was found that values of resistance factors considerably differ for different design methods, load-settlement criteria, and load capacity components. For the total resistance, resistance factors for LCPC method were higher than others, while those for Aoki-Velloso's and Philipponnat's methods were in similar ranges. In respect to load-settlement criteria, 0.1B and Chin's criteria produced higher resistance factors than DeBeer's and Davisson's criteria. Resistance factors for the base and shaft resistances were also presented and analyzed.

The Effect of Road Distribution Around the School Buildings on the Status of Study on the Effect of Noise (주변도로 분포가 학교건축물의 소음실태에 미치는 영향에 관한 연구)

  • Kim, Tae-Woo;Lee, Kang-Guk;Hong, Won-Hwa
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.4
    • /
    • pp.3-12
    • /
    • 2011
  • This study investigates interior and exterior environments and arrangement forms of school buildings from elementary to high school which were recently built in Daegu since the 7th Educational Curriculum. In addition, this study analyses how outside noise affects inside environment of schools. This study found that the noise level criteria of school facilities(such as exterior learning sites and outer walls of school buildings) adjacent to street of one side satisfiedly corresponded to the level and criteria, 65dB(A), of school health law. However, the noise level and vibration criteria of school facilities adjacent to street of two sides did not satisfiedly corresponded to the level or criteria, 65dB(A). In case of classrooms, the inner noise of educational facilities with windows closed and also close to both the street of one side and of two sides satisfiedly corresponded to the level or criteria. 55dB(A), of school health law. In spring and tall, the windows are more open them usual for ventilation, and leaving windows open can lead to noise from outside. Thus, it is urgent to prepare for this situation.

  • PDF