• Title/Summary/Keyword: Environmental Noise Automatic Measurement System

Search Result 8, Processing Time 0.024 seconds

A Study on the Selection of Measurement Point for Automatic Environmental Noise Measurement System (환경소음자동측정망의 측정지점 선정에 관한 연구)

  • Lim, J.S.;Lee, B.C.;Jeong, D.J.;Lee, M.H.;Yang, K.H.;Oh, Y.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.442-445
    • /
    • 2007
  • A noise reduction policy can be more effectively made when automatic environmental noise measurement system is set up. However, the local characteristic of noise pollution requires a lot of measurement points. This study considers that automatic environmental noise measurement system connects with automatic air pollution measurement system and noise map. The measurement points of traffic volume by the National Police Agency and the Ministry of Construction and Transportation are investigated to use at drawing the road traffic noise map. Finally, the effective application method of the environmental noise measurement vehicle is discussed.

  • PDF

Study on Adequate Positioning of Environmental Noise Automatic Measuring System in Busan (부산시 환경소음 자동측정망 설치위치의 적정성에 관한 연구)

  • Kim, Hwa-Il;Han, Kyoung-Min
    • Journal of Environmental Policy
    • /
    • v.8 no.1
    • /
    • pp.31-48
    • /
    • 2009
  • To install and operate the Automatic Noise Monitoring Networks reasonably, which able to monitoring environmental noise continually, is an important issue for making decision to urban environment. Noise level is determined by regional environmental factors, that affected by complex urban environment. Therefore, accurate measurement of environmental noise level has top priority to establish and promote appropriate environmental policies. Currently, Automatic Noise Monitoring System is installed for grasping the environmental noise level and preparing basic data for constructing noise-reduction policies. However, this measurement data is recognized not to be able to reflect a sensory noise. The main reason is the lack of reliable measurement data and unreasonable installation site. The main point of this research ought to be the analysis of installed site of noise monitoring system in Busan.

  • PDF

A Study on Sampling Techniques to Assure the Representativeness of Short-term Equivalent Noise Level (단기간 소음도의 대표성 확보를 위한 소음도 추출기법 연구)

  • Ryu, Hun Jae;Ko, Joon Hee;Chang, Seo Il;Lee, Byung Chan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.12
    • /
    • pp.1213-1219
    • /
    • 2012
  • The purpose of this study is to present a guideline to design a short-term manual measurement of environmental noise level, which is more economical and flexible, but less representative than long-term automatic measurement. The proposed guideline can provide the number of measurement times and the length of measurement term required to secure the extent of the representativeness. The data was collected at 4 sites located in Seoul and at 4 sites located outside of Seoul. The probabilities for five-minute equivalent noise levels, Leq, 5min, to stay in an error range from the quarterly representative noise level were used to evaluate sampling techniques. The probability analysis of the daytime period showed that the noise levels measured between 10 am and 2 pm and between 9 pm and 10 pm have the probabilities higher than 60 %. On the other hand, even for the same length of total measurement time, increasing the number of random samplings results in higher probabilities than increasing the length of measurement term.

Study on the Characteristics of Noise/Vibration in the Upright Laying Hen House (직립식 산란계사 내의 소음 진동 발생 현황 조사연구)

  • Lee S.J.;Chang D.I.;Chang H.H.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • This study was carried out to measure and analyze the characteristics of noise and vibration, and to analyze their effects on the productivity of layers, mechanical troubles, and abnormal wear-out failure of facilities and equipment of the layer house. The measurements of noise and vibration were taken at 13 layer farms nationwide for the operations of feed supplier system, feed distribution system, automatic egg collection system, ventilation system, blot conveyer for layer feces, and fur the case of with and without their operation by a sound level meter and a vibration measuring system in the layer house equipped with upright multi-tier cages. Measurement results showed that normal times were noise(N) 82 dB and vibration(V) 0.2072 cm/s, feed supplier system were 90 dB(N) and 2.8560 cm/s(V), feed distribution system were 90 dB(N) and 2.0222 cm/s(V), automatic egg collection system were 87 dB(N) and 0.1865 cm/s(V), ventilation system 88 dB(N) and 2.5364 cm/s(V), belt conveyer fur layer feces were 88 dB(N) and 0.2387 cm/s(V), and then maximum values of noise and vibration were 90 dB and 2.8560 cm/s, respectively, when feeding systems(feed supplying system and feed distribution system) were operated. Based on these results, an experiment is being conducted to find out the effect of noise and vibration on the productivity of layers in the layer house equipped with upright multi-tier cages.

  • PDF

Design of an RCGA-based Linear Active Disturbance Rejection Controller for Ship Heading Control

  • Ahn, Jong-Kap;So, Myung-Ok
    • Journal of Navigation and Port Research
    • /
    • v.44 no.5
    • /
    • pp.423-429
    • /
    • 2020
  • A ship's automatic steering system is the basis for addressing control difficulties related to course-changing and course-keeping during navigation through heading angle control, and is a link in realizing unmanned and autonomous ships. This study proposes a robust RCGA-based linear active disturbance rejection controller (LADRC) design method considering environmental disturbances, measurement noise, and model uncertainties in designing a ship heading controller for use when the ship is sailing. The LADRC consisted of a transient profile, a linear extended state observer, and a PD controller. The control gains in the LADRC with the linear extended state observer were adjusted by RCGAs to minimize the integral of the time-weighted absolute error (ITAE), which is an evaluation function of the control system. The proposed method was applied to ship heading control, and its effectiveness was validated by comparing the propulsive energy loss between the proposed method and a conventional linear PD controller. The simulation results showed that the proposed method had the advantages of lower propulsive energy loss, more robustness, and higher tracking precision than the conventional linear PD controller.

Dynamic Response and Vibration Characteristics of an Isolation Rail Track under a Traveling Mass (주행질량하의 방진 궤도레일의 동적응답 및 진동특성)

  • Oh, B.J.;Ryu, B.J.;Kim, J.H.;Lee, Y.S.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.4
    • /
    • pp.365-373
    • /
    • 2011
  • This paper presents the dynamic response and the vibration characteristics for a rail-track supported by discrete springs and dampers. Recently, automatic conveyer system, rail-track, rack-master system demand the soundproof facilities and vibration suppression measures in order to satisfy the strict environmental standards. The equations of motions of the dynamic characteristics for a vibration suppression rail-track under a traveling mass were derived by Galerkin's mode summation method considering gravity, centrifugal force, Coriolis force, inertia force of the moving mass, transverse inertia of the rail-track. Also, numerical results were calculated by Runge-Kutta integration method. In order to investigate vibration characteristics and dynamic responses, modal testing and measurement of the responses of the rail-track were performed. Through the experiment and numerical simulations, numerical results have a good agreement with experimental ones.

Development of an Interventricular Pressure Measurement System or the Korean Total Artificial Heart (한국형 인공심장내의 심실간 압력 측정시스템의 개발)

  • Choi, S.W.;Ahn, J.M.;Jo, Y.H.;Om, K.S.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.126-130
    • /
    • 1997
  • In the development of the totally implantable artificial heart (TAH), the information of the preload condition is important to ind appropriate condition or the automatic control of the heart. Our TAH configuration consists of two artificial ventricles, and brushless DC motor within actuator. The pressure between ventricles could indicate the preload condition during the TAH operation. If we can measure accurately inspite of the noise induced from TAH and environmental condition. We suggested integrating a feedback loop to remove an unexpected DC drift. NPI 19-series Nova sensor was used which could measure pressure in gas and liquid. This method and sensor enabled us to develop the pressure transducer compact so (that) the systems can be implanted with TAH into patient. This system has been verified in vitro and in vivo test. This results showed that the output waveform of this system was stable irrespective of animal condition.

  • PDF