• Title/Summary/Keyword: Environmental Efficiency

Search Result 7,323, Processing Time 0.031 seconds

Evaluation of Heavy Metal Removal Efficiency in Artificial Acidic Drainage Using Calcite and Aragonite (방해석과 아라고나이트를 이용한 인공산성배수의 중금속 제거 효율 평가)

  • Byeong Cheol Song;Young Hun Kim;Jeong Jin Kim
    • Economic and Environmental Geology
    • /
    • v.57 no.3
    • /
    • pp.319-327
    • /
    • 2024
  • Calcite and aragonite are polymorphs with the chemical formula CaCO3. In this study, natural limestone and aragonite, as well as scallop and clam shells composed of calcite and aragonite, were used as the pH-raising neutralizing agents for model solutions containing various heavy metals such as Cd, Cu, Fe, Mn, and Zn to simulate acidic drainage. According to the experimental results, pH-raising effect is higher in the shell materials compared to natural ores for both the calcite and aragonite types. Natural calcite and scallop shells are found to be the most suitable media for Cd removal, while over 95% efficiency for Cu and Fe removal was observed in all four media. Zn removal efficiency is higher in aragonite and clam shells, while Mn removal efficiency is relatively low, to be below 50%, for all four media. Overall, the heavy metal removal efficiency, except for Mn, was over 90%, in the order of Fe > Cu > Cd > Zn > Mn.

Efficiency Comparison between Output Tax and Emission Tax as an Environmental Tax (과세형태에 따른 환경세의 조세효율성 비교: 산출물과세 vs. 배출세)

  • Kim, Sang Kyum
    • Journal of Environmental Policy
    • /
    • v.11 no.4
    • /
    • pp.131-154
    • /
    • 2012
  • Existing researches on tax efficiency of environmental taxes mostly focuses on taxes imposed on the consumption process of the final output, or goods that create pollution during the input process of intermediate goods. The assumption here is that there is a significant relation between the consumption of polluting goods and the pollution itself. However, in reality they are not identical. This signifies that the above assumption may distort the actual results. This study classifies environmental tax into two different forms, output tax and emission tax. Theformer is the tax that is imposed on the consumption of polluting goods, while the latter is directly levied onto the emission of pollution. It then compares the efficiency of these taxes through the computational general equilibrium simulations. After analyzing the simulation, it was proven that the direct imposition on pollution, or environmental tax as emission tax, was more effective in terms of tax efficiency. Furthermore, these results were revealed as irrelevant to the assumption of homotheticity in utility function. Thus, if market-distortionary tax already exist, then the effectiveness of revenue neutral environmental tax reform will be sensitive to the assumption of homotheticity for utility function. However, environmental taxes as emission taxes have been shown to be more effective in tax efficiency than output taxes.

  • PDF

Effects of Domestic Wastewater Treatment used Biofilm-Electrode Reactor(BER) (生物膜 電極反應機를 이용한 廚房廢水 처리 효과)

  • Noh, Hyun-Woong;Yoon, Oh-Sub
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.1
    • /
    • pp.43-49
    • /
    • 1997
  • This study was aimed to estimate removal efficiency(%) of BER(Biofilm-Electrode Reactor) and A.S(Activated Sludge) treatments. When were analyzed COD$_{Cr}$, NH$_3$-N and T-P by current density and reaction time, the results were as follows : 1) In BER treatment, the removal efficiency of COD$_{Cr}$ in domestic wastewater was 79-86% when current density was 2.39 mA/dm$2$(15mA)-3.98 mA/dm$^2$(25mA) and reaction time was 48 hr. 2) Removal efficiency of NH$_3$-N was 71-73% when current density was 2.39-3.98 mA/dm$^2$ and reaction time 48 hr. 3) When the reaction time was 48 hr removal efficiency(%) of BER treatment for COD$_{Cr}$, NH$_3$-N and T-P were more excellent than A.S. treatment. And then we prospect that was because activated microorganism colonies attached in biofilm on surface of electrode pannel. Therefore, In order to derive BER treatment efficiency(%) should establish optimum conditions of pH, temp., reaction time, current density and biochemical and electrochemical states.

  • PDF

A Study on the Mass Collection Efficiency in Collector Step of Electrostatic Precipitator by Physical Gas Characterization (전기집진장치에서 가스의 물리적인 특성에 따른 포집구역내의 입자포집율 연구)

  • Ha, Sang-An;Im, Gyeong-Taek;Sin, Nam-Cheol
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.36-40
    • /
    • 1998
  • This study was carried out to investigate the collection Efficiency of mass in collector step at the different of physical gas characterization. This work has focused on the dependence of the collection efficiency of mass in the collector zone of a two-stage set up field with gas temperature T and the dew point tmeperature. To identify the dependence of the mass collection efficiency on the Bounded plate of the collector zone MP.k by the spectre electric resistance of dust $p_e$. and the relative humidify ${\varphi}$, 20 at- tempts have been made with three different gas temperature ($50{\circ}C, 80{\circ}C, 110{\circ}C$) at different dew point. At the specific electric resistance of dust $p_e$=$10^6{\Omega}m$ which relative humidity corresponds to $\phi$ > 15%, a easy rise of the sounded plate secluded dust mass share was measured atwain. As the result of the higher cohesion imprisonment power due to the adsorbtion of particle, the rinse of the relative humidity developed on the particle surface. Therefore, the collection efficiency of mass was not predominant the high temperature T in the collector zone, neither was the pecific ellectric resistance of dust dependent.

  • PDF

The removal of nitrogen & phoshorus for the swine wastewater by VSEP membrane system (진동막 분리장치를 이용한 축산폐수의 질소.인 제거에 관한 연구)

  • 지은상;김재우;신대윤
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.3
    • /
    • pp.31-36
    • /
    • 2000
  • Conventional membrane systems was difficults to treatment for the swine waste water. Technological advances in membrane filtration systems have created opportunity for the swine wastewater to treat effluent streams in order to meet stricter environmental constraints. "Vibratory Shear Enhanced Processing(VSEP)" developed by new logic international makes it possible to filter effluent streams without the fouling problem exhibited by conventional membrane systems. Various kinds of waste water occurred to and swine wastewater experiment with "VSEP" set up conventional reverse osmosis membrane (ACM-4, ESPA, BW-30). The results were as followes : Treatment efficiency for the input COD(From $332mg/{\ell}$ to $4,968mg/{\ell}$) was 98%. Treatment efficiency for the input SS(From $140mg/{\ell}$ to $4,040mg/{\ell}$) was 100%(All together). Treatment efficiency for the input T-N(From $155mg/{\ell}$ to $934mg/{\ell}$) was 97%~99.8%. Treatment efficiency for the input T-P(From $28.6mg/{\ell}$ to $132mg/{\ell}$) was 99.7% and up. ESPA membrane excels three types of reverse osmosis membranes applied VSEP in removal efficiency.

  • PDF

SND in the Fixed Media Tank of Membrane-BNR Process Treating Low C/N Wastewater (저농도 하수 유입 Membrane-BNR공정내 고정상담체 호기조에서의 SND)

  • Jeong, Yong-Chul;Lee, Jung-Yeol;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.3
    • /
    • pp.328-332
    • /
    • 2008
  • This research was about T-N removal efficiency of oxic reactor in which fixed media submerged from Membrane BNR(An+Ax+Ox) process. This experiment was implemented by using fixed media and changing DO concentration in the oxic reactor. Nitrification efficiencies of all modes were more than 98%. When no media was in the oxic reactor, T-N removal efficiency was only 47.4%, while it were shown from 60.3% to 67.4% with packed media, which indicated improved efficiency of 27~42%. The removal efficiencies of TCOD and BOD were more than 89%, 98% respectively, which could satisfy the guideline of advanced sewage reclamation by Department of Environment. When DO concentration in the packed oxic-media tank was 0.5~1.0 mg/L, T-N removal efficiency was low, which resulted from insufficient nitrification in the oxic reactor. Therefore, DO concentration of bulk solution needs to be kept more than 1.0 mg/L to induce higher nitrification efficiency in the reactor in which media was submerged. Also, the selection of DO concentration is important to prevent media from being clogged.

Evaluation of Electrokinetic Removal of Heavy Metals from Tailing Soils

  • Kim, Soon-Oh;Kim, Kyoung-Woong;Yun, Seong-Taek
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.40-43
    • /
    • 2002
  • Electrokinetic remediation was studied for the removal of toxic heavy metals from tailing soils. This study emphasized the dependency of removal efficiency upon heavy metal speciation, as demonstrated by different extraction methods (sequential extraction, total digestion, and 0.1 N HC1 extraction). The tailing soils examined showed different physicochemical characteristics, in view of initial pH, particle size distribution, and major mineral constituents, and contained high concentrations of target metal contaminants in various forms. The electrokinetic removal efficiency of heavy metals was significantly influenced by their partitioning prior to treatment, and by the pHs of the tailing soils. The mobile and weakly bound fractions of heavy metals, such as exchangeable fraction, were easily removed by electrokinetic treatment (more than 90% in removal efficiency), whereas immobile and strongly bound fractions, such as organically bound and residual fractions, were not effectively removed (less than 20% in removal efficiency).

  • PDF

Sludge Solubilization using Microwave Irradiation in the Presence of Fe Powder

  • Yi, Min-Joo;Choi, Hyun-Kyung;Han, Ihn-Sup
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.2
    • /
    • pp.40-46
    • /
    • 2010
  • In this study, microwave irradiation, which is reflected by metals, was used to reduce the amount of sewage sludge, and the results were used to verify solubilization efficiency and determine optimum operation conditions. Biogas production and methane content of the gas under optimized conditions were measured with the biochemical methane potential (BMP) test. The sludge was taken from a thickened sludge tank at J sewage treatment plant (JSTP) in Seoul, Korea. For the experiments, 50 mL of sludge was filled in vessels and the vessels were irradiated with the power of 500, 600, 700, and 800W for 2~5 min. In addition, Fe powder was added by 0.01, 0.05, and 0.1 g to compare the efficiency with and without Fe powder. The results confirmed that solubilization efficiency was higher in the presence of Fe powder. The optimum conditions of 0.01 g addition of Fe powder with 800W irradiation for 5 min, yielded nearly 22.95% higher solubilization efficiency than without Fe powder. The BMP tests were carried out using sludge obtained from the experiments carried out under the optimum conditions. As a result, sludge subjected by 800W with 0.01 g of Fe powder for 5 min displayed the highest level of gas production and methane content. Through this study, it could be confirmed that solubilization efficiency increased by addition of Fe powder.

Soft computing techniques in prediction Cr(VI) removal efficiency of polymer inclusion membranes

  • Yaqub, Muhammad;EREN, Beytullah;Eyupoglu, Volkan
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.418-425
    • /
    • 2020
  • In this study soft computing techniques including, Artificial Neural Network (ANN) and Adaptive Neuro-Fuzzy Inference System (ANFIS) were investigated for the prediction of Cr(VI) transport efficiency by novel Polymer Inclusion Membranes (PIMs). Transport experiments carried out by varying parameters such as time, film thickness, carrier type, carier rate, plasticizer type, and plasticizer rate. The predictive performance of ANN and ANFIS model was evaluated by using statistical performance criteria such as Root Mean Standard Error (RMSE), Mean Absolute Error (MAE), and Coefficient of Determination (R2). Moreover, Sensitivity Analysis (SA) was carried out to investigate the effect of each input on PIMs Cr(VI) removal efficiency. The proposed ANN model presented reliable and valid results, followed by ANFIS model results. RMSE and MAE values were 0.00556, 0.00163 for ANN and 0.00924, 0.00493 for ANFIS model in the prediction of Cr(VI) removal efficiency on testing data sets. The R2 values were 0.973 and 0.867 on testing data sets by ANN and ANFIS, respectively. Results show that the ANN-based prediction model performed better than ANFIS. SA demonstrated that time; film thickness; carrier type and plasticizer type are major operating parameters having 33.61%, 26.85%, 21.07% and 8.917% contribution, respectively.

Analysis of sewage treatment process for the improvement of T-N removal process (T-N 제거공정 개선을 위한 하수처리장 공정 분석)

  • Shin, Choon Hwan
    • Journal of Environmental Science International
    • /
    • v.27 no.2
    • /
    • pp.99-107
    • /
    • 2018
  • In order to design the improvement process for T-N removal, the treatment process of Suyoung, Gangbyeon, and Noxan sewage treatment plants (STP) in Busan was anlayzed. Suyoung STP shows a T-N removal efficiency of about 69.8% with MLE(Modified Ludzack ettinger) and A2O+MBR. However, it is necessary to improve the process to maintain over DO of 1 mg/L and is required to install a flow control tank to minimize the rainfall effect. Gangbyun STP shows a about 70.2% T-N removal efficiency with A2O+GFF(gravity fiber filtration). However, in order to improve T-N removal efficiency, it is needed to install MLE process to treat recycle water. Noksan STP shows a T-N removal efficiency of about 71.0% with MLE+Chemical treatment and shows stable T-N concentration in effluent. However, it is required a toxic chemical management process because bad wastewater flows into the STP, also is necessary a process improvement in order to increase internal recycling ratio. Especially, it is required a process improvement to increase HRT of nitrification tank because Suyoung and Gangbyeon STPs shows low nitrification efficiency during winter season.