• 제목/요약/키워드: Environment and HVDC Transmission

검색결과 13건 처리시간 0.022초

±500kV HVDC 2회선 송전선로의 전기환경특성 예측 및 평가 (Prediction and Analysis of Electrical Environmental Characteristics under ±500kV HVDC Double Bipole Transmission Line)

  • 우정민;주문노;신구용;권구민;최우정;이재현
    • 전기학회논문지
    • /
    • 제67권4호
    • /
    • pp.554-560
    • /
    • 2018
  • Since Korea has a small land area, it is expected to construct the conductor return type with neutral wire in the case of ${\pm}500kV$ HVDC double bipole transmission line. Therefore, in order to apply ${\pm}500kV$ HVDC double bipole transmission line with neutral wire in Korea, it is necessary to develop technology for insulation and environmental designs. In this study, radio interference, audible noise, electric field and ion current density according to the polarity arrangement were compared and assessed in the ${\pm}500kV$ HVDC double bipole transmission line with the conductor return method. And the optimum configuration of HVDC double bipole transmission line was determined from the viewpoint of electrical environment.

초고압 직류가공 송전선로에서의 전계 및 이온류 특성분석 (Analysis of Electric field and Ion Characteristics on HVDC Overhead Transmission Line)

  • 임재섭;신구용;이동일;주문노;양광호
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1638-1643
    • /
    • 2010
  • HVDC is better economic method than HVAC in case of long distance transmission and it is possible to interconnect transmission lines regardless of difference of power frequency. The electrical environment problems of HVDC overhead transmission line are electric field, charged voltage, ion current and so on. For biopolar HVDC lines, most of the ions are directed toward the opposite polarity conductor, but a significant fraction is also directed toward the ground. These problems are major factor to design configuration of HVDC overhead transmission line. Therefore, It is necessary to test an environmental characteristics of HVDC overhead transmission line. In this paper, to assess the ion characteristic of HVDC transmission line, continuous measurements have been done on the biopolar single circuit line with ACSR 480mm2-6 bundle conductors of Gochang HVDC Test line. And then the ion characteristics were analyzed.

The Study on the Efficient HVDC Capacity Considering Extremely Low Probability of 765kV Double Circuit Transmission Lines Trip

  • Moon, Bong-Soo;Ko, Boyung;Choi, Jin-San
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1046-1052
    • /
    • 2017
  • The load on the power grid of South Korea is expected to grow continuously until the late 2020s, and it is necessary to increase the transfer capacity from the Eastern grid to the Seoul-Gyeonggi region by reinforcing the transmission network for the electric power system to remain stable. To this end, the grid reinforcement by two bipole LCC HVDC transmission systems have been considered on account of the public acceptability and high growth of the fault current level, even though an additional 765kV system construction is more economical. Since the probability of the existing 765kV double circuit transmission line trip is extremely low, a dynamic simulation study was carried out to estimate the efficient HVDC capacity able to stabilize the transient stability by utilizing the HVDC overload capability. This paper suggests the application plan to reduce the HVDC construction capacity with ensuring the transient stability during the 765kV line trip.

HVDC ${\pm}500kV$ 가공 송전선로의 최적 도체방식 선정을 위한 전기환경특성 평가 (Assessment of the Electrical Environmental Characteristics to Decide Optimal Bundle Type for HVDC ${\pm}500kV$ Overhead Transmission Lines)

  • 주윤노;길경석;양광호;이성두;황기현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권11호
    • /
    • pp.520-526
    • /
    • 2006
  • Corona interferences, such as radio noise, audible noise and television noise, need to be taken into account in the design of HVDC transmission line conductor configuration. Therefore the line designer requires data from which to estimate the corona performance of any set of conductors. To get a sufficiently complete set of design data, it is necessary to examine the corona test of a large number of conductor geometries. This paper presents the results of corona cage test among three types of candidate conductors. It is quite clear from test results that the conductor geometries play an important role in establishing the magnitude of corona noise. Corona noise data from corona cage test are expressed as a statistical distribution of results obtained over long periods of time and various weather conditions. Therefore we can determine an environmentally-friendly conductor bundle for HVDC overhead transmission line. Based on this finding results, various simulations about HVDC line configurations, such as pole space and pole height, will be conducted. And then finally an optimal configuration for HVDC transmission line will be decided.

초고압 직류 가공 송전선로에서 발생되는 이온 계측시스템 개발 (The Development of System for Measuring Ion Generated from HVDC Overhead Transmission Line)

  • 주문노;양광호;이동일;신구용;임재섭
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.2035-2040
    • /
    • 2008
  • The electrical discharge of high voltage direct current(HVDC) overhead transmission line generate audible noise, radio noise, electric field, ion current and induced voltage on the ground. These items are major factors to design environmentally friendly configuration of DC transmission line. Therefore, HVDC transmission lines must be designed to keep all these corona effects within acceptable levels. Several techniques have been used to assess interference caused by ions on HVDC overhead transmission line. In this study, to assess the ion characteristic of DC line, the ion current density and induced voltage caused by ion flow were measured by plate electrodes manufactured from a metal flat board and charged bodies, respectively. The charged body has two types of cylinder and cylindrical plate. From the results of calibration experiments, the sensitivity of flat electrode and charged body can be obtained. At present, the developed system is used to investigate the ion generation characteristics of Kochang DC ${\pm}500kV$ test line.

실증시험선로를 이용한 도체귀로형 HVDC ±500 kV Double Bipole 가공송전선로의 이온류 특성 평가 (Ion Effects of HVDC ±500 kV Double Bipole Overhead Transmission Line with Metallic Return Conductor Using Full-scale Test Line)

  • 신구용;권구민;주문노;우정민
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권4호
    • /
    • pp.249-256
    • /
    • 2019
  • 국내에 향후 건설 예정인 도체귀로형 HVDC ±500 kV Double Bipole 가공송전선로의 최적선로 형상을 설계하고 송전선로에서 발생되는 전기환경장해를 검증하기 위해 실증시험장을 구축하여 1년간 전기환경장해 평가시험을 수행하였다. 또한, HVDC Double Bipole 실선로에서 인체의 지표면 전계인지도 평가시험을 통해 HVDC 실규모 실증선로 직하에서 인체가 직류 전계를 감지하는 임계값을 조사하여 HVDC ±500 kV Double Bipole 가공송전선로의 직류전계 설계기준안의 타당성을 검증하였다. HVDC ±500 kV Double Bipole 시험선로의 극형상은 전기환경장해와 운영관점에서 동일한 극성을 대각으로 배치하였으며, 국내 가공송전선로의 전기환경장해의 사회적인 수용성을 고려하여 선로에서 코로나방전이 거의 발생되지 않도록 소도체 방식은 6 도체를 선정하였다. 도체귀로형 HVDC ±500 kV Double Bipole 가공송전선로 방식인 Cardinal×6B를 적용한 실증시험결과, 선로 도체에서 코로나 방전이 거의 발생되지 않았으며, 따라서 지표면 전계와 이온전류밀도는 모두 국내 가공송전선로 설계 기준값을 만족하였다. 또한 선로직하에서 피조사자들에 대한 전계 인지도 평가결과, 피조사자들의 70%는 23 kV/m에 노출되어도 직류전계를 인지하지 못하는 결과를 나타냈다.

HVDC 가공 송전선로 전기환경특성 모의시험용 코로나 케이지 계측시스템 개발 (Development of Corona Cage Measurement System for Simulation on Electrical Environmental Characteristics of HVDC Overhead Transmission Line)

  • 길경석;양광호;이성두;주문노
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.245-249
    • /
    • 2006
  • Corona characteristics of conductors are dependent on the electric field conditions in the immediate vicinity of the conductors. In case of DC transmission line, particularly, the space charge plays an important role in the electric field distribution. Therefore, DC corona cage simulation is necessary for long-term test in the same conditions. This paper presents the results of designing and constructing hardwares such as DC power supply, measurement system and DAS to carry out the simulation. The corona cage longitudinally is divided into five equal length sections and three inner sections of those are isolated from the ground of outer cage. The measurement items are radio noise, corona current, television noise, audible noise and meteorological conditions. In the next step, various simulations about the type and configuration of two or three candidate conductors will be conducted. And then finally an environmentally-friendly conductor for HVDC overhead transmission line will be decided.

HVDC DC CT 선형성 최적화 및 시스템 적용에 대한 연구 (Linearity Optimization of DC CT and a Study on the Application of HVDC System)

  • 최용길;이은재;최호석;이욱화
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.758-763
    • /
    • 2014
  • These days, the advantages of DC power system are consistently stand out in korea that was a small power loss and high stability. Needs of DC power transmission technology is focused In the midst of a smart grid and environment friendly generation technology boom that is needed for next generation technology. Researches and businesses for HVDC(High Voltage Direct Current) system has been began. But, Needs of HVDC equipment and system commissioning technology are not on the rise until now. In particular, South Korea's HVDC technology is after the foot runner of advanced country and company. In addition, There is no experience for equipment verification and commissioning technology. And Experts of HVDC are rare. Who has been fully understood hardware and system as a whole, and identified all the equipment's characteristic. Recently, Academia and industry are recognized a needs of HVDC technology. But it does not received a recognition of technical value. In this paper, introduce issues when we apply the IEEE's verification method for HVDC system, especially DC current measurement system, DC CT(Direct Current Transformer), among the HVDC equipments. And Proposes remedial methods on the issue in order to recognize the necessity that was HVDC equipments's verification and commissioning technology research should be focused on.

도체귀로형 ±500 kV Double Bipole 송전선로 공기절연에 관한 연구 (Study on the Air Insulation Design Guideline for ±500 kV Double Bipole Transmission Line with Metallic Return Conductor)

  • 신구용;권구민;송성환;우정욱
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권3호
    • /
    • pp.141-147
    • /
    • 2019
  • 최근 전력산업에 가장 커다란 이슈는 신재생에너지의 증가이며 이에 따라 전력계통의 수용성을 확보하기 위한 다양한 기술개발이 추진되고 있다. 또한 세계적으로 보다 융통성 있는 친환경 에너지의 활용을 위하여 국가 및 지역간 전력계통을 연계하는 슈퍼그리드의 구성이 추진되고 있다. 이러한 성격이 서로 다른 계통 간에 연계를 위하여 반드시 요구되는 기술이 초고압 직류송전기술이다. 지금까지 국내에서는 육지와 제주도를 해저케이블로 연결하는 HVDC 송전기술이 적용되었으나 동해안의 발전단지에서 수도권의 부하밀집 지역으로 장거리 대용량 전력전송을 위한 직류가공송전 방식의 기술개발이 추진되고 있다. 인구밀도가 높고 산악이 많은 국내 환경을 고려해 최소한의 경과를 활용하여 8 GW 급의 대용량 전력을 전송하기 위해 도체귀로방식의 ${\pm}500kV$ Double Bipole 송전선로 설계기술을 개발하고 이를 적용하기 위한 사업화를 추진하고 있다. 본 논문에서는 세계 최초로 적용 예정인 도체귀로방식의 Double Bipole 송전선로의 설계를 위한 절연특성에 관한 연구를 수행하고 송전선로에 발생하는 다양한 과전압현상에 견디는 공기절연특성을 실증시험을 통하여 검증하고 이를 서술하였다.

Well-being기법을 이용한 해남-제주간 HVDC System신뢰도평가 (Reliability Assessment in Hea-nam Cheju HVDC system using Well-being Method)

  • 손현일;이효상;신동준;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.227-229
    • /
    • 2004
  • In a new competitive market environment, it is very important to determines how much power can be transferred through the network. It's known as Available Transfer Capability(ATC). This paper presents a technique to evaluate Reliability Assesment and the Available Transfer Capability of Haenam-Cheju HVDC transmission system using Well-being Method which is based on the probabilistic method. The system Well-being is categorized in terms of the system Healthy and Marginal in addition to the conventional Risk index. Haenam-Cheju HVDC system has been studied for the optimal ATC based in well-being categories.

  • PDF