• Title/Summary/Keyword: Entrance number

Search Result 333, Processing Time 0.026 seconds

Lmainar flow and heat transfer of the fluid with low prandtl number in the entrance region of a circular pipe (낮은 프란틀수를 가지는 유체의 원관 입구 층류유동 및 열전달)

  • ;;Yoo, Jung Yul
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.5 no.4
    • /
    • pp.284-292
    • /
    • 1981
  • The flow of fluid with low prandtl number in the entrance region of a circular pipe has been considered, where the wall temperature is maintained to be constant. A finite difference method is used for the integral form of the governing equations in order that they satisfy the conservative properties of the numerical solutions. It is confirmed that the hydrodynamic entrance length and be divided into growing boundary layer region and fully viscous region, which is compared with existing results obtained by using boundary layer approximations. By assuning the developing velocity profile in the entrance region, the thermal entrance length is estimated and the local Nusselt number is obtained at various locations along the axial dirction.

Fishing capacity and bycatch on spring net pot for conger eel by entrance size (스프링그물통발의 입구 크기에 따른 붕장어 어획성능과 혼획)

  • SONG, Dae-Ho;CHO, Sam-Kwang;CHA, Bong-Jin
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.1
    • /
    • pp.9-16
    • /
    • 2016
  • This study was conducted to analyze fishing capacity and bycatch by mesh size and entrance size of spring net pot conducted by water tank and field experiment. The water tank experiments were conducted by using traps with mesh size of 22 mm and entrance size of 120 mm and 140 mm, respectively in the water tank of NIFS. The field experiment was conducted using 5 kinds of spring net pot with mesh sizes of 20 mm, 22 mm, 35 mm and entrance size of 120 mm, 130 mm, 140 mm, 360 mm by coastal trap fishery vessel operating around the area of Geoje island. In the result of water tank experiments, the catch of conger eel was 1.5 times higher when using trap with entrance size of 140 mm than that of 120 mm. In the field experiment, when using same mesh size, the larger the entrance size, the higher amount of conger eel catch, bycatch and number of bycatch species. When using the same entrance size, the larger the mesh size, the lower amount of conger eel catch and number of bycatch species, whereas the amount of bycatch showed increasing trend.

A Study on Velocity Profiles and Critical Dean Number of Developing Transitional Unsteady Flows in a Curved Duct (곡관덕트의 입구영역에서 천이비정상유동의 속도분포와 임계딘수에 관한연구)

  • 이행남
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.862-870
    • /
    • 1998
  • In this paper an experimental investigation of characteristics of developing transitional unsteady flows in a square-sectional 180。 curved duct are presented. The experimental study using air is carried out to measure axial velocity profiles secondary flow velocity profiles and entrance length by using Laser Do ppler Velocimeter(LDV) system. The flow development is found to depend upon Dean number dimensionless angular frequency velocity amplitude ration and cur-vature ratio. Of special interest is the secondary flow generated by centrifugal effects in the plane of the cross-section of the duct. The secondary flows are strong and complicate at entrance region. The entrance length of transitional pulsating flow is obtained to 120。 of bended angle of duct in this experimental conditions.

  • PDF

Drag Reducton of Pipe Wall For Fluid Flow due to Injected Polymer Solution - III. Consideration of Entrance Region Flow of Drag Reducing Fluids- (고분자용액에 의한 유체수송관벽의 저항감소 -III. 저항감소유체의 입구흐름 영역에 대한 고찰-)

  • 김영보;유경옥
    • Fire Science and Engineering
    • /
    • v.5 no.2
    • /
    • pp.21-35
    • /
    • 1991
  • As a part of studies of drag reduction phenomenon, at the entrance flow region of abrupt contraction tube flowing water, dilute and concentrated drag reducing polymer solutions contraction losses are estimated experimentally. Futher more, entrance lengths are considered theoretically and are measured experimentally. In the present experiment, fluid temperature is fixed l$0^{\circ}C$ and flow rates are 3,000

  • PDF

A Study on the Flow Characteristics of developing transitional Steady Flows in the Entrance Region of a Curved Duct (곡관덕트의 입구영역에서 천이정상유동의 유동특성에 관한 연구)

  • 봉태근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.33-39
    • /
    • 1999
  • In this paper an experimenatal investigation of characteristics of developing ransitional steady flows in a square-sectional $180^{\circ}$ curved duct is presented, The experimental study is carried out to measure axial velocity profiles secondary flow velocity profiles and entrance length by using Laser Dopper Velocimeter(LDV) system. The flow development is found to depend upon Dean number and curvature ratio. Of special interest is the secondary flow generated by centrifugal effects in the plane of the cross-section of the duct. The secondary flows becomes strong from $120^{\circ}$ of bended angle on the duct. The entrance length of transitional steady flow is obtained to $120^{\circ}$ of bended angle of the duct in this experimental conditions.

  • PDF

Projection number of the graduate student in high school around the capital area and an entrance quota (수도권지역의 고3학생 수 예측과 대학입학정원수와의 분석)

  • Yoon, Yong-Hwa;Kim, Jong-Tae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.3
    • /
    • pp.523-534
    • /
    • 2010
  • The purpose of this paper is to forecast the numbers of students in a capital areas until 2027 year by using the moving average methods for estimating the number of student at the elementary, meddle and high-school. It is analyzed the third student number at the high schools and the entrance quota of colleges and universities around capital areas until 2027. The result of this paper is that there are no problems to keep the current entrance quota of colleges and universities around capital areas until 2027.

The heat transfer characteristics of viscoelastic non-newtonian fluids in the entrance region of circular tube flows (원형관속을 유동하는 점탄성 유체의 입구 영역 열전달 특성에 관한 연구)

  • 엄정섭;황태성;유상신
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.1032-1043
    • /
    • 1989
  • The heat transfer characteristics of the drag reducing polymer solutions are investigated experimentally in the thermal entrance region of circular tube flows. Fluids used in experiments are the aqueous solutions of high molecular polymer, polyacrylamide Separan AP-273 and the range of polymer concentrations is from 20 to 1000 wppm. Two stainless steel tubes with inside diameter 8.5mm(L/D=712) and 10.3mm(L/D=1160) are used for the heat transfer flow loops. The flow loop is set up to measure friction factors and heat transfer coefficients of test sections in two different modes; the recirculating flow system and once-through flow system. The test tubes are heated directly by electricity to apply the constant heat flux boundary conditions to the wall. Three different types of adaptors are used to observe the effects of the upstream flow conditions of the heat transfer test sections. The viscosity and characteristic relaxation time of the test fluids circulating in the flow system are measured by the capillary tube viscometer and falling ball viscometer at regular time intervals. The installed adaptors exhibit slight effect on the entrance heat transfer of Newtonian fluid. However, no noticeable effects are observed for the entrance heat transfer of the drag reducing fluids. The order of magnitude of the thermal entrance lengths of the drag reducing fluids which follow the minimum friction asymptote is much longer than that of Newtonian fluids in turbulent flows. A new dimensionless parameter, the viscoelastic Graetz number, is defined and all the experimental data are recasted in terms of the viscoelastic Graetz number. The local Nusselt number of the viscoelastic fluids is represented as a function of flow behavior index n and the viscoelastic Graetz number. As degradation continues the viscosity and the characteristic relaxation time of the testing fluids decrease. Weissenberg number defined by the relaxation time and D/V appears to be a proper dimensionless parameter in describing degradation effects on heat transfer of the viscoelastic fluids.

A Study on the Estimation of the Number of Suitable Entrances for Emergency Evacuation Facilities through Modeling and Simulation (M&S를 통한 비상대피시설의 적정 출입구 개수 산정에 관한 연구)

  • Lee, Jeong-Moon;Roh, Jeong-Heon;Park, Young-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.129-130
    • /
    • 2019
  • In this research, we determine the proper number of entrances in the evacuation facilities for civil and military personnel. The current standards on the emergency evacuation facility only sets the number of possible evacuees and the according architectural floor area since the evacuation have been completed. However, other than static standards such as the floor area, there is needs to consider the dynamic standards along with allowable evacuation time such as the number of entrance, staircases and so on. Therefore, we need to consider the number of entrances and their location in order to account for the allowed evacuation time of particular number of people in a set area. The outcome could be contributed to the standards which should contain the dynamic conditions associated with evacuation.

  • PDF

A Numerical Analysis on Thermal and Fluid in Solar Concentration Absorber with Tilt Angle and Opening Ratio of Absorber Entrance (태양열 집광 흡수기 입구의 개방비와 경사각도에 따른 열유체 유동에 관한 수치해석)

  • Lee, Snag-Chul;Lee, Yong-Hun;Choi, Seuk-Cheun;Shin, You-Sik;Jeong, Hyo-Min;Jeong, Han-Sik
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1485-1490
    • /
    • 2003
  • This paper is the analysis of thermal and fluid in solar concentration absorber with various tilt angle and opening ratio of absorber entrance. The purpose of this study is to develop optimum solar concentration absorber, and the parameters for the study are the opening ratio of absorber entrance and the tilt angle. The aspect ratio of absorber was fixed at 0.64, and opening ratio was changed from 0.1 to 1.0. The finite volume method with SIMPLE computational algorithm are used and analyzed the heat transfer in absorber inside walls.

  • PDF

The Field Investigation of Optical Shop Entrance Facilities for the Mobility Impairment from the Universal Design - Focused on Seoul Metropolitan City (유니버설디자인 관점에서 이동약자를 위한 안경원 출입구 편의시설 실태조사 - 서울특별시를 중심으로)

  • Yu, Samyoung;Lee, Sehee;Han, Jinyong;Kim, Youngbin;Choi, Moonsung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.1
    • /
    • pp.7-19
    • /
    • 2023
  • Purpose: Mobility impairment persons are all people who experience mobility difficulties in their daily lives, which makes up about 30% of the population in Seoul Metropolitan City; this number is expected to increase with population aging. As the number of mobility impairment persons in need of vision correction increases, it is necessary to create the Universal Design guidelines and to provide the foundation to access convenience facilities at the entrance of optical shops, a health and medical institution. Methods: Of the 2,282 optical shops located in Seoul, 252 optical shops were chosen for data collection of actual photos, from April 10, 2022 to September 4, 2022. Based on the photographs, the height difference between the entrance and the sidewalk, safety handles, and opening and closing methods of entrances were investigated, as these factors correspond to the accessibility and the mobility of the mobility impairment persons. Results: Of the 252 optical shops surveyed, 114 (45.2%) have resolved the problems of height difference through improving horizontal accessibility (61) or using ramps (53). 36 (14.3%) optical shops chose automatic doors for opening and closing methods of the entrance. Implications: The rate of installation of access convenience facilities for the entrance of optical shops is slightly lower than the rate of installation of ramps, surveyed by the Ministry of Health and Welfare. It is necessary to apply the Universal Design to access convenience facilities for the entrance of optical shops for not only the mobility impairment persons but all people, regardless of age or ability, to conveniently access healthcare services.