• 제목/요약/키워드: Enophthalmos

검색결과 73건 처리시간 0.031초

Three-Dimensional Pre-Bent Titanium Implant for Concomitant Orbital Floor and Medial Wall Fractures in an East Asian Population

  • Lee, Kyung Min;Park, Ji Ung;Kwon, Sung Tack;Kim, Suk Wha;Jeong, Eui Cheol
    • Archives of Plastic Surgery
    • /
    • 제41권5호
    • /
    • pp.480-485
    • /
    • 2014
  • Background The objective of this article is to evaluate clinical outcomes of combined orbital floor and medial wall fracture repair using a three-dimensional pre-bent titanium implant in an East Asian population. Methods Clinical and radiologic data were analyzed for 11 patients with concomitant orbital floor and medial wall fractures. A combined transcaruncular and inferior fornix approach with lateral canthotomy was used for the exposure of fractures. An appropriate three-dimensional preformed titanium implant was selected and inserted according to the characteristics of a given defect. Results Follow-up time ranged from 2 to 6 months (median, 4.07 months). All patients had a successful treatment outcome without any complications. Clinically significant enophthalmos was not observed after treatment. Conclusions Three-dimensional pre-bent titanium implants are appropriate for use in the East Asian population, with a high success rate of anatomic restoration of the orbital volume and prevention of enophthalmos in combined orbital floor and medial wall fracture cases.

외상 후 안면변형에 대한 지연재건술 (Delayed reconstruction of posttraumatic facial deformities)

  • 김용하
    • 대한의사협회지
    • /
    • 제61권12호
    • /
    • pp.740-748
    • /
    • 2018
  • Posttraumatic facial deformities (PTFDs) are very difficult to correct, and if they do occur, their impact can be devastating. It may sometimes be impossible for patients to return to normal life. The aim of surgical treatment is to restore the deformed bone structure and soft tissue to create symmetry between the affected side and the opposite side. In the process of managing PTFD, correcting enophthalmos is one of the most challenging aspects for surgeons because of difficulties in overcoming the scar tissue and danger of injuring to the optic nerve. In this article, surgical options for reconstruction of the medial wall, floor, lateral wall, and roof of the orbit are described. To optimize aesthetic improvement, additional cosmetic procedures such as facial contouring surgery, blepharoplasty and rhinoplasty can be used. Plastic surgeons should join emergency trauma teams to implement an overall treatment plan containing rational strategies to avoid or minimize PTFD.

Oculocardiac reflex in an adult with a trapdoor orbital floor fracture: case report, literature review, and differential diagnosis

  • Brasileiro, Bernardo Ferreira;Sickels, Joseph E. Van;Cunningham, Larry L. Jr.
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권6호
    • /
    • pp.428-434
    • /
    • 2020
  • Orbital floor blowout fractures can result in a variety of signs and symptoms depending on the severity of the bone defect. Large defects often result in enophthalmos and restriction of ocular movement; yet the timing of surgery can be delayed up to two weeks with good functional outcomes. In contrast, an orbital trapdoor defect with entrapment of the inferior rectus muscle usually elicits pain with marked restriction of the upward gaze and activation of the oculocardiac reflex without significant dystopia or enophthalmos. When autonomic cardiac derangement is diagnosed along with an orbital floor fracture, it has been suggested that the fracture should be treated immediately. Otherwise, it will result in continued hemodynamic instability and muscular injury and may require a second surgery. This article reports the management of an unusual presentation of a trapdoor blowout orbital floor fracture surgery with oculocardiac response in an adult, with emphasis on its pathophysiology, management, and differential diagnosis.

광범위한 안와하벽골절에서 속눈썹밑 절개 및 비강 내 내시경적 접근을 동시에 사용한 재건술 (The Reconstruction of the Extensive Inferior Blow-out Fracture Through Endoscopic Transnasal and Subciliary Approaches)

  • 최수종;오흥찬;남수봉;강철욱;배용찬
    • 대한두개안면성형외과학회지
    • /
    • 제10권2호
    • /
    • pp.86-90
    • /
    • 2009
  • Purpose: Inferior blow-out fracture is the common facial fracture. Unsatisfactory functional and aesthetic outcomes are frequent when it is treated inappropriately. If fractures are extended and reach the posterior end of orbital floor, enophthalmos frequently followed as complication. The purpose of this study was to evaluate reduction technique of extensive inferior blow-out fracture with ballooning of foley catheter through endoscopic transnasal approach and implantation of $Medpor^{(R)}$ through subciliary approach. Methods: A retrospective study was performed on 14 patients with extensive inferior blow-out fracture who underwent ballooning of foley catheter through endoscopic transnasal approach with implantation of $Medpor^{(R)}$ through subciliary approach. Patients were operated from May 2005 to November 2007. Data for 14 patients were acquired from patient's charts. Preoperative and postoperative data for enophthalmos, diplopia, limitation of extraocular motion were reviewed. Preoperative and postoperative CT scan were also checked. The patients were followed up from 4 to 18 months. Results: The enophthalmos was corrected in all patients. Among 7 patients with diplopia preoperatively, diplopia was resolved in three patients postoperatively. The diplopia persisted in four patients and two of them also had limitation of extraocular motion postoperatively. The limitation of extraocular motion occurred in seven patients preoperatively. But five patients recovered after operation immediately. These symptoms were resolved about three months after the operation. Conclusion: The ballooning of foley catheter through endoscopic transnasal approach with implantation of $Medpor^{(R)}$ through subciliary approach can be considered one of the appropriate technique for extensive inferior blowout fracture.

안와 파열 골절 치료 시 삽입물 종류에 따른 후유증 비교 (Comparison of Sequelae According to the Types of Implants in Blow-Out Fracture)

  • 김태곤;임종효;이준호;김용하
    • 대한두개안면성형외과학회지
    • /
    • 제10권1호
    • /
    • pp.23-28
    • /
    • 2009
  • Purpose: Blow out fracture can present tenderness, swelling, enophthalmos, extraoccular muscle limitation, paresthesia, diplopia according to severity of injury, so reconstruction of blow out fracture is important. Orbital soft tissue should be in orbit and defected orbital wall should be corrected by autologus tissue or alloplastic implants. Every implants have their merits and faults, every implants are used various. This study was designed to compare the sequelae of blow-out fracture repair using the alloplastic implants: micro-titanium mesh(Micro Dynamic titanium $mesh^{(R)}$, Leibinger, Germany), porous polyethylene ($Medpor^{(R)}$, Porex, USA), absorbable mesh plate(Biosorb $FX^{(R)}$ . Bionx Implants Ltd, Finland). Methods: Between January 2006 and April 2008, 52 patients were included in a retrospective study analysing the outcome of corrected inferior orbital wall fracture with various kind of implants. Implants were inserted through subciliary incision. Twenty patients were operated with micro-titanium mesh, fourteen patients with porous polyethylene and eighteen patients with absorbable mesh plate. In comparative category, enophthalmos, diplopia, range of motion of extraoccular muscle, inferior orbital nerve injury were more on frequently statistically in patients. Results: Fourteen of 18 patients underwent surgical repair to improve diplopia, 11 of 17 patients to improve parasthesia, 11 of 15 patients to improve enophthalmos, 8 of 9 patients to improve extraoccular muscle limitation. Duration of follow-up time ranged from 6 months to 12 months(mean, 7.4 months). There was no statistic difference of sequelae between micro titanium mesh and porous polyethylene and absorbable mesh plate in blowout fracture, inferior wall. Conclusion: There is no difference of sequelae between micro-titanium mesh, porous polyethylene and absorbable mesh plate in blow-out fracture, inferior wall. The other factors such as defect size, location, surgeon's technique, may influence the outcome of blow-out fracture repair.

상악동염이 있는 안와 하벽 골절에서 예방적 항생제의 중요성 (Antibiotic Prophylaxis' Effect on Enophthalmos in Orbital Floor Fracture with Chronic Maxillary Sinusitis)

  • 성형우;김진우;신한경;정재학;김영환;선욱
    • 대한두개안면성형외과학회지
    • /
    • 제9권2호
    • /
    • pp.67-71
    • /
    • 2008
  • Purpose: Orbital floor fracture has open wound to maxillary sinus and if the patient has chronic maxillary sinusitis, it may be have more risk of infection, complications. The purpose of this comparative study is to be the effectiveness of prophylactic antibiotics in orbital floor fracture with chronic maxillary sinusitis. Methods: We studied 20 patients who diagnosed as orbital floor fracture with chronic maxillary sinusitis from march, 2005 to may, 2006. Among them 16 were male, 4 were female and age was ranged from 15 to 68, average was 42. A day before operation, Prophylactic antibiotics were used to 10 patients. Prophylactic antibiotics were not used to 10 patients. We defined control group as prophylactic antibiotics injection group a day before operation. After surgery, we confined use of same antibiotic for 7 days in both group. After 6 month from surgery, we compare the degree of enophthalmos from healthy side to legion side with hertel exopthalmometry(Inami, Japan) in control group and non-prophylactic antibiotics injection group. Results: In control group, comparison of discrepancy between enophthalmic eyeball and normal eyeball with Hertel exophthalmometer was 1.1 mm and non-prophylactic antibiotics injection group was 2.1 mm. In independent sample t-test, control group was showed statistically significant difference with non-prophylactic antibiotics injection group(p=0.007). Conclusions: In orbital floor fracture with chronic maxillary sinusitis, bacteria in maxillary sinus can increase post-operative complication by infecting infraorbital soft tissue, and it is thought to be antibiotic prophylaxis is play a role in decrease in degree of enophthalmos. We feel the need to further study of prophylactic antibiotics in orbital floor fracture with chronic maxillary sinusitis.

Two-Year Follow-up on the Use of Absorbable Mesh Plates in the Treatment of Medial Orbital Wall Fractures

  • You, Jae-Pil;Kim, Deok-Woo;Jeon, Byung-Joon;Jeong, Seong-Ho;Han, Seung-Kyu;Dhong, Eun-Sang;Kim, Woo-Kyung
    • Archives of Plastic Surgery
    • /
    • 제40권6호
    • /
    • pp.728-734
    • /
    • 2013
  • Background Absorbable materials offer many advantages in the reconstruction of orbital walls; however, the possibility of postoperative enophthalmos after complete absorption cannot be excluded. We evaluated the postoperative results of absorbable mesh plates used as onlay implanting on the medial orbital wall to determine whether they are suitable for medial orbital wall reconstruction. Methods The study included 20 patients with medial orbital wall fractures who were followed up for more than 2 years postoperatively. We used absorbable mesh plates in all of the patients. We measured the following: the changes in the expanded orbital volume by comparing the preoperative and postoperative computed tomography (CT) scans and the degree of clinical enophthalmos. Results There were no major complications associated with the use of absorbable materials such as infection, migration, or extrusion of mesh plates during the long-term follow-up. The orbital volumetric changes between the preoperative and postoperative CT scans were not statistically significant. However, the expanded orbital volume was not related to the degree of clinical enophthalmos. Conclusions The reconstructed orbital wall may provide supportive scar tissue to the orbital contents even after the absorbable materials have dissolved completely. Absorbable mesh plates could be another option for the reconstruction of the medial orbital wall.

Reconstruction of Medial Orbital Wall Fractures without Subperiosteal Dissection: The "Push-Out" Technique

  • Kim, Yong-Ha;Lee, Jin Ho;Park, Youngsoo;Kim, Sung-Eun;Chung, Kyu-Jin;Lee, Jun-Ho;Kim, Tae Gon
    • Archives of Plastic Surgery
    • /
    • 제44권6호
    • /
    • pp.496-501
    • /
    • 2017
  • Background Various surgical methods for repairing medial orbital wall fractures have been introduced. The conventional technique requires total separation of the displaced orbital bones from the orbital soft tissues. However, subperiosteal dissection around the fracture can cause additional damage. The aim of the present study is to introduce a method of reconstructing medial orbital wall fractures without subperiosteal dissection named the "push-out" technique. Methods Six patients with post-traumatic enophthalmos resulting from an old medial orbital wall fracture and 10 patients with an acute medial orbital wall fracture were included. All were treated with the push-out technique. Postoperative computed tomography (CT) was performed to assess the correct positioning of the implants. The Hertel scale and a comparison between preoperative and postoperative orbital volume were used to assess the surgical results. Results Restoration of the normal orbital cavity shape was confirmed by examining the postoperative CT scans. In the old fracture group, the median orbital volume of the fractured side was $29.22cm^3$ preoperatively, and significantly improved postoperatively to a value of $25.13cm^3$. In the acute fracture group, the median orbital volume of the fractured side was $28.73cm^3$ preoperatively, and significantly improved postoperatively to a value of $24.90cm^3$. Differences on the Hertel scale also improved, from 2.13 mm preoperatively to 0.25 mm postoperatively in the old fracture group and from 1.67 mm preoperatively to 0.33 mm postoperatively in the acute fracture group. Conclusions The push-out technique can be considered a good alternative choice for old medial orbital wall fractures with posttraumatic enophthalmos, acute medial orbital wall fractures including large fractured bone segments, and single-hinged greenstick fractures.

안와하내벽 파열골절의 임상적 의의 (Clinical Significance of Orbital Inferiomedial Blow Out Fracture)

  • 유재홍;하원;이지원;양완석
    • 대한두개안면성형외과학회지
    • /
    • 제14권1호
    • /
    • pp.24-29
    • /
    • 2013
  • Background: The incidence of blow out fractures is increasing and the techniques of diagnosis and treatment have been recently evolving. Despite its clinical significance, there has been no study on orbital inferiomedial blow out fractures. Therefore, this study was designed to investigate the clinical significance of treatment of orbital inferiomedial blow out fractures. Methods: A retrospective review of fifty-seven patients who could be followed up for at least 1 year after surgical reconstruction of pure inferiomedial blow out fracture was undertaken. The transconjunctival approach was performed in all cases. The onlay technique was used in 32 patients and the inlay/sheet method was used in 25 patients. We evaluated the clinical outcomes using the chi-square test. Results: In the group using the onlay technique, postoperative diplopia and enophthalmos were observed in 14 cases and 3 cases, respectively. Of these, 5 cases and 3 cases lasted for more than 6 months, respectively. In the group using the inlay/sheet method, postoperative diplopia was observed in 9 cases, but there were no cases of enophthalmos. Among the 9 diplopia cases, 4 lasted for more than 6 months. Conclusion: Postoperative diplopia and enophthalmos were increased after treatment of inferiomedial blow out fractures compared to isolated medial (0.6%, 0.3%) or inferior (1.8%, 0.6%) blow out fractures. Therefore, careful dissection is necessary not to injure the inferior oblique muscle to decrease the incidence of postoperative diplopia. Moreover, the inlay/sheet method is an effective option for reconstruction of inferiomedial blow out fractures.

풍선 달린 카테터를 이용한 안저 파열 골절 정복의 선택적 사용 (Alternative Use of Inferior Blow-out Fracture Reduction with Urinary Balloon Catheter)

  • 박성훈;양호직
    • Archives of Plastic Surgery
    • /
    • 제34권6호
    • /
    • pp.729-734
    • /
    • 2007
  • Purpose: The operative treatment for blow-out fracture involves restoration of intra-orbital soft tissue and bony structural integrity. There are several methods for reconstruction of inferior blow out fracture. We report reduction of inferior blow-out fracture with urinary balloon catheter in comparison with $Medpor^{(R)}$ using group to complication rate. Methods: A retrospective study was performed on 67 patients who underwent inferior orbital blow-out fracture reconstruction with $Medpor^{(R)}$ implant or urinary balloon catheter following between 2003 and 2006. Hospital records were reviewed especially for preoperative and postoperative enophthalmos, diplopia, extraocular muscle movement limitations, and hypoesthesia between $Medpor^{(R)}$ implant group and balloon catheter using group. Results: There was no significant statistical difference between both groups on incidence of postoperative complications of enophthalmos, diplopia, extraocular muscle movement limitations, and hypoesthesia. Postoperative infection, ectropion were absent in both groups.Conclusion: The use of urinary balloon catheter is simple, fast and inexpensive. Urinary balloon catheter is an alternative and reliable use for reduction of inferior orbital blow-out fracture.