• 제목/요약/키워드: Enhanced CT

검색결과 299건 처리시간 0.043초

조영증강 전산화단층촬영검사에서 보이지 않는 이하선의 다형선종 (Invisible Parotid Gland Pleomorphic Adenoma on Contrast Enhanced-Computed Tomography)

  • 허재형;김다미;구본석;장재원
    • 대한두경부종양학회지
    • /
    • 제32권2호
    • /
    • pp.85-89
    • /
    • 2016
  • Pleomorphic adenomas is the most common tumor of parotid gland and usually located and confined in superficial lobe of parotid gland. Computed tomography (CT) is commonly used to initially evaluate salivary gland lesion, but contrast-enhanced CT may sometimes fail to reveal lesions in spite of a high clinical suspicion. For this reason, ultrasonography (US) can be used as the first-line image work-up in some cases of parotid gland benign tumors. We experienced a case of a 60-year-old woman without underlying disease presenting a palpable parotid mass in which the initial CT examination was reported as 'no obvious mass detected'. However, the lesion was revealed in US and histologically confirmed as pleomorphic adenoma. The patient underwent superficial parotidectomy through modified facelift incision. To the best of our knowledge, this is the first report of invisible major salivary gland tumor on CT in the Korean literature.

딥러닝 네트워크를 이용한 조영증강 CT 영상 생성 (Synthesis of contrast CT image using deep learning network)

  • 우상근
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2019년도 제59차 동계학술대회논문집 27권1호
    • /
    • pp.465-467
    • /
    • 2019
  • 본 논문에서는 영상생성이 가능한 딥러닝 네트워크를 이용하여 조영증강 CT 영상을 획득하는 연구를 수행하였다. CT는 고해상도 영상을 바탕으로 환자의 질병 및 암 세포 진단에 사용되는 의료영상 기법 중 하나이다. 특히, 조영제를 투여한 다음 CT 영상을 획득되는 영상을 조영증강 CT 영상이라 한다. 조영증강된 CT 영상은 물질의 구성 성분의 영상대비를 강조하여 임상의로 하여금 진단 및 치료반응 평가의 정확성을 향상시켜준다. 하지많은 수의 환자들이 조영제 부작용을 갖기 때문에 이에 해당되는 환자의 경우 조영증강 CT 영상 획득이 불가능해진다. 따라서 본 연구에서는 조영증강 영상을 얻지 못하는 환자 및 일반 환자의 불필요한 방사선의 노출을 최소화 하기 위하여 영상생성 딥러닝 기법을 이용하여 CT 영상에서 조영증강 CT 영상을 생성하는 연구를 진행하였다. 영상생성 딥러닝 네트워크는 generative adversarial network (GAN) 모델을 사용하였다. 연구결과 아무런 전처리도 거치지 않은 CT 영상을 이용하여 영상을 생성하는 것 보다 히스토그램 균일화 과정을 거친 영상이 더 좋은 결과를 나타냈으며 생성영상이 기존의 실제 영상과 영상의 구조적 유사도가 높음을 확인할 수 있다. 본 연구결과 딥러닝 영상생성 모델을 이용하여 조영증강 CT 영상을 생성할 수 있었으며, 이를 통하여 환자의 불필요한 방사선 피폭을 최소하며, 생성된 조영증강 CT 영상을 바탕으로 정확한 진단 및 치료반응 평가에 기여할 수 있을거라 기대된다.

  • PDF

침투성 반응벽체를 위한 고활성 영가금속 개발 (Development of Activity Enhanced Zero Valent Metals for Permeable Reactive Barrier)

  • Kim, Young-Hun;Kim, Myung-Chul
    • 한국환경과학회지
    • /
    • 제12권2호
    • /
    • pp.201-205
    • /
    • 2003
  • The dechlorination of chlorinated methanes by iron powder and palladium coated iron (Pd/Fe) was studied in batch experiments. Iron powder dechlorinated carbon tetrachloride (CT) with a half-life of 4 days. Three chloromethane was found as major product and less chlorinated daughters. Mass balance found was to be about 93-99%. Pd/Fe showed very enhanced reactivity for CT in comparing with plain iron. The major dechlorination products of CT were also less chlorinated methanes with Pd/Fe. Pd/Fe also degrade the produced less chlorinated compounds. Sequential reactions were occurred on Pd/Fe. As the Pd/Fe content increased, the reaction rate was increased linearly.

Automatic Liver Segmentation of a Contrast Enhanced CT Image Using an Improved Partial Histogram Threshold Algorithm

  • Seo Kyung-Sik;Park Seung-Jin
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권3호
    • /
    • pp.171-176
    • /
    • 2005
  • This paper proposes an automatic liver segmentation method using improved partial histogram threshold (PHT) algorithms. This method removes neighboring abdominal organs regardless of random pixel variation of contrast enhanced CT images. Adaptive multi-modal threshold is first performed to extract a region of interest (ROI). A left PHT (LPHT) algorithm is processed to remove the pancreas, spleen, and left kidney. Then a right PHT (RPHT) algorithm is performed for eliminating the right kidney from the ROI. Finally, binary morphological filtering is processed for removing of unnecessary objects and smoothing of the ROI boundary. Ten CT slices of six patients (60 slices) were selected to evaluate the proposed method. As evaluation measures, an average normalized area and area error rate were used. From the experimental results, the proposed automatic liver segmentation method has strong similarity performance as the MSM by medical Doctor.

Remnant parietal serosa detection in a cat with true diaphragmatic hernia using computed tomography

  • Lee, Sang-Kwon;Jeong, Wooram;Choi, Jihye
    • 대한수의학회지
    • /
    • 제59권2호
    • /
    • pp.105-108
    • /
    • 2019
  • A 4-year-old cat was referred for a suspected pulmonary mass. True diaphragmatic hernia presence was diagnosed via computed tomography (CT). There was a thin membrane covering the diaphragmatic defect. The membrane was thinner than the diaphragm. After contrast injection, the membrane was less enhanced than that of the normal diaphragm. The membrane was identified as a remnant of the parietal pleura. In addition, contrast-enhanced CT images provided clarity in viewing the herniated liver and falciform fat. A thinner membrane, covering the diaphragmatic defect, and attached to the thicker normal diaphragm, is considered a unique CT feature of true diaphragmatic hernia.

SNOMED CT 브라우저에서 검색 결과의 재구성 기법 (A Restructuring Method for Search Results of SNOMED CT Browser)

  • 류우석
    • 대한임베디드공학회논문지
    • /
    • 제10권3호
    • /
    • pp.165-170
    • /
    • 2015
  • SNOMED CT browser is a browsing tool for searching clinical terms in SNOMED CT which is a standard terminology set used worldwide. The search result view of previous browsers merely list up candidate terminologies. The problem is that most of users become confused about how to select an appropriate term from the list. This leads serious waste of medical recoding cost. This paper discusses characteristics of SNOMED CT dataset and proposes a novel design of enhanced result view by restructuring the results using relationships of SNOMED CT concepts. Using the proposed scheme, medical doctors or officers can select appropriate terms more efficiently and can reduce overall recording time.

Diagnostic Value of Computed Tomography in Crohn's Disease Patients Presenting with Acute Severe Lower Gastrointestinal Bleeding

  • Lee, Sunyoung;Ye, Byong Duk;Park, Seong Ho;Lee, Kyung Jin;Kim, Ah Young;Lee, Jong Seok;Kim, Hyun Jin;Yang, Suk-Kyun
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1089-1098
    • /
    • 2018
  • Objective: To investigate the diagnostic yield of contrast-enhanced computed tomography (CT) in Crohn's disease (CD) patients presenting with acute severe lower gastrointestinal bleeding (LGIB), and the role of CT in predicting the risk of rebleeding. Materials and Methods: A consecutive series of 110 CD patients presenting with acute severe LGIB between 2005 and 2016 were analyzed. Among them, 86 patients who had undergone contrast-enhanced CT constituted the study cohort. The diagnostic yield of CT for detecting contrast extravasation was obtained for the entire cohort and compared between different CT techniques. In a subgroup of 62 patients who had undergone CT enterography (CTE) and showed a negative result for extravasation on CTE, the association between various clinical and CTE parameters and the risk of rebleeding during subsequent follow-up was investigated using Cox regression analysis. Results: The diagnostic yield of CT was 10.5% (9 of 86 patients). The yield did not significantly differ between single-phase and multiphase examinations (p > 0.999), or between non-enterographic CT and CTE (p = 0.388). Extensive CD (adjusted hazard ratio [HR], 3.27; 95% confidence interval [CI], 1.09-9.80; p = 0.034) and bowel wall-to-artery enhancement ratio (adjusted HR, 2.81; 95% CI, 1.21-6.54; p = 0.016) were significantly independently associated with increased rebleeding risks, whereas anti-tumor necrosis factor-${\alpha}$ therapy after the bleeding independently decreased the risk of rebleeding (adjusted HR, 0.26; 95% CI, 0.07-0.95; p = 0.041). Conclusion: The diagnostic yield of contrast-enhanced CT was not high in CD patients presenting with acute severe LGIB. Nevertheless, even a negative CTE may be beneficial as it can help predict the risk of later rebleeding.

조영제를 사용하지 않은 복보 CT영상에서 신장의 추출에 대한 연구 (A Study on the Segmentation of Kidney from the Non-Enhanced CT Image)

  • 김선주;유승화;김종철;노승무;박종원
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2000년도 봄 학술발표논문집 Vol.27 No.1 (B)
    • /
    • pp.514-516
    • /
    • 2000
  • 본 논문은 조영제를 사용하지 않은 정상인의 신장의 추출에 관한 연구로서 복구 CT 영상의 특성을 파악하고 신장부분을 분석함으로서 신장의 자동적인 추출을 시행하였다. 처리과정에서 기준값에 의한 이진영상에서 각 장기의 서로 다른 화소분포의 특징을 이용하여 장기추출을 시행하였고 템플리트를 이용한 서브트랙션과 채우기 과정을 거쳐 단일 슬라이스에서 신장을 추출한 후 추출된 신장영상의 슬라이스들을 겹친 영상을 생성하여 단일 슬라이스 내에서 제거되지 못한 노이즈들을 제거하였다.

  • PDF

Imaging Assessment of Visceral Pleural Surface Invasion by Lung Cancer: Comparison of CT and Contrast-Enhanced Radial T1-Weighted Gradient Echo 3-Tesla MRI

  • Yu Zhang;Woocheol Kwon;Ho Yun Lee;Sung Min Ko;Sang-Ha Kim;Won-Yeon Lee;Suk Joong Yong;Soon-Hee Jung;Chun Sung Byun;JunHyeok Lee;Honglei Yang;Junhee Han;Jeanne B. Ackman
    • Korean Journal of Radiology
    • /
    • 제22권5호
    • /
    • pp.829-839
    • /
    • 2021
  • Objective: To compare the diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3-tesla (3T) magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of visceral pleural surface invasion (VPSI). Visceral pleural invasion by non-small-cell lung cancer (NSCLC) can be classified into two types: PL1 (without VPSI), invasion of the elastic layer of the visceral pleura without reaching the visceral pleural surface, and PL2 (with VPSI), full invasion of the visceral pleura. Materials and Methods: Thirty-three patients with pathologically confirmed VPSI by NSCLC were retrospectively reviewed. Multidetector CT and contrast-enhanced 3T MRI with a free-breathing radial three-dimensional fat-suppressed volumetric interpolated breath-hold examination (VIBE) pulse sequence were compared in terms of the length of contact, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. Supplemental evaluation of the tumor-pleura interface (smooth versus irregular) could only be performed with MRI (not discernible on CT). Results: At the tumor-pleura interface, radial VIBE MRI revealed a smooth margin in 20 of 21 patients without VPSI and an irregular margin in 10 of 12 patients with VPSI, yielding an accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and F-score for VPSI detection of 91%, 83%, 95%, 91%, 91%, and 87%, respectively. The McNemar test and receiver operating characteristics curve analysis revealed no significant differences between the diagnostic accuracies of CT and MRI for evaluating the contact length, angle of mass margin, or arch distance-to-maximum tumor diameter ratio as predictors of VPSI. Conclusion: The diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3T MRI and CT were equal in terms of the contact length, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. The advantage of MRI is its clear depiction of the tumor-pleura interface margin, facilitating VPSI detection.

Significantly Low Effective Dose from 18FDG PET/CT Scans Using Dose Reducing Strategies: "Lesser is Better"

  • uz Zaman, Maseeh;Fatima, Nosheen;Zaman, Areeba;Zaman, Unaiza;Tahseen, Rabia
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권7호
    • /
    • pp.3465-3468
    • /
    • 2016
  • Background: Fluorodeoxyglucose ($^{18}FDG$) PET/CT imaging has become an important component of the management paradigm in oncology. However, the significant imparted radiation exposure is a matter of growing concern especially in younger populations who have better odds of survival. The aim of this study was to estimate the effective dose received by patients having whole body $^{18}F$-FDG PET/CT scanning as per recent dose reducing guidelines at a tertiary care hospital. Materials and Methods: This prospective study covered 63 patients with different cancers who were referred for PET/CT study for various indications. Patients were prepared as per departmental protocol and 18FDG was injected at 3 MBq/Kg and a low dose, non-enhanced CT protocol (LD-NECT) was used. Diagnostic CT studies of specific regions were subsequently performed if required. Effective dose imparted by 18FDG (internal exposure) was calculated by using multiplying injected dose in MBq with coefficient $1.9{\times}10^{-2}mSv/MBq$ according to ICRP publication 106. Effective dose imparted by CT was calculated by multiplying DLP (mGy.cm) with ICRP conversion coefficient "k" 0.015 [mSv / (mG. cm)]. Results: Mean age of patients was $49{\pm}18$ years with a male to female ratio of 35:28 (56%:44%). Median dose of 18FDG given was 194 MBq (range: 139-293). Median CTDIvol was 3.25 (2.4-6.2) and median DLP was 334.95 (246.70 - 576.70). Estimated median effective dose imparted by $^{18}FDG$ was 3.69 mSv (range: 2.85-5.57). Similarly the estimated median effective dose by low dose (non-diagnostic) CT examination was 4.93 mSv (range: 2.14 -10.49). Median total effective dose by whole body 18FDG PET plus low dose non-diagnostic CT study was 8.85 mSv (range: 5.56-13.00). Conclusions: We conclude that the median effective dose from a whole body 18FDG PET/CT in our patients was significantly low. We suggest adhering to recently published dose reducing strategies, use of ToF scanner with CT dose reducing option to achieve the lower if not the lowest effective dose. This would certainly reduce the risk of second primary malignancy in younger patients with higher odds of cure from first primary cancer.