• 제목/요약/키워드: Enhance Tube

검색결과 178건 처리시간 0.027초

피에조 필름을 이용한 축중감지기 개발 (Development of a Weight in Motion sensor using Piezo Film)

  • 양희선;박연규;강대임;김엄기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.262-267
    • /
    • 2000
  • This paper describes a weight in motion(WIM) sensor to measure the weight of a vehicle in motion. The main sensing element of the WIM sensor is the PVDF(Polyvinylidene fluoride) film that shows rapid response to an external excitation. Due to the property of rapid response, it is possible to measure the weight of a vehicle in motion with high speed. In the development of the WIM sensor, the dominant target value was the uniformity of the sensor. To increase the uniformity, We employed shrinkable tube made of rubber to enhance the uniformity, and performed the rolling of the brass tube repeatedly. The uniformity of the sensor was examined experimentally. It was comparable to that of a WIM sensor of the MSI which was the benchmark of this development. This paper also describes the mechanical modeling of the sensor and the suitable charge amplifier for the sensor.

  • PDF

바이패스 오리피스 팽창장치의 유동 특성에 관한 실험적 연구 (Experimental study on characteristics of two-phase flow through a bypass-orifice expansion device)

  • 최종민;김용찬
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.109-116
    • /
    • 1999
  • To establish optimum cycle of the inverter-driven heat pump with a variation of frequency, the bypass orifice, which is a short tube having a bypass hole in the middle, was designed and tested. Flow characteristics of the bypass orifice were measured as a function of orifice geometry and operating conditions. Flow trends with respect to frequency were compared with those of short tube orifices and capillary tubes. Generally, the bypass orifice showed the best flow trends among them, that will enhance the seasonal energy efficiency ratio of an inverter heat pump system. Based on experimental data, the semi-empirical flow model was developed to predict mass flow rate through bypass orifices. The maximum difference between measured data and model's prediction was within ${\pm}5%$.

  • PDF

Evaluation of New Design Concepts for Steam Generators in Sodium Cooled Liquid Metal Reactors

  • Kim, Seong-O.;Sim Yoonsub;Kim, Eui-kwang.;Myung-Hwan.Wi;Han, Dohee.
    • Nuclear Engineering and Technology
    • /
    • 제35권2호
    • /
    • pp.121-132
    • /
    • 2003
  • To reduce the construction cost and enhance the safety of sodium cooled liquid metal reactors, various kinds of new design concepts were evaluated using the KALIMER operation condition. The required equipment sizes were set for plant electricity output to be similar to that of KALIMER. The evaluations were made focusing on the plant performance and implementation practicality. Each design concept was evaluated for the concept itself and design impacts to interfacing systems. Through the evaluation of the concepts, it was found that the most favorable design concept is the integrated steam generator with forced convection using lead bismuth as the intermediate heat transfer fluid between the primary sodium tube and feed water/steam tube in the steam generator.

Effects of exploration and molecular mechanism of CsV on eNOS and vascular endothelial functions

  • Zuo, Deyu;Jiang, Heng;Yi, Shixiong;Fu, Yang;Xie, Lei;Peng, Qifeng;Liu, Pei;Zhou, Jie;Li, Xunjia
    • Advances in nano research
    • /
    • 제12권5호
    • /
    • pp.501-514
    • /
    • 2022
  • This study aimed to investigate the effects and potential mechanisms of Chikusetsusaponin V (CsV) on endothelial nitric oxide synthase (eNOS) and vascular endothelial cell functions. Different concentrations of CsV were added to animal models, bovine aorta endothelial cells (BAECs) and human umbilical vein endothelial cells (HUVECs) cultured in vitro. qPCR, Western blotting (WB), and B ultrasound were performed to explore the effects of CsV on mouse endothelial cell functions, vascular stiffness and cellular eNOS mRNA, protein expression and NO release. Bioinformatics analysis, network pharmacology, molecular docking and protein mass spectrometry analysis were conducted to jointly predict the upstream transcription factors of eNOS. Furthermore, pulldown and ChIP and dual luciferase assays were employed for subsequent verification. At the presence or absence of CsV stimulation, either overexpression or knockdown of purine rich element binding protein A (PURA) was conducted, and PCR assay was employed to detect PURA and eNOS mRNA expressions, Western blot was used to detect PURA and eNOS protein expressions, cell NO release and serum NO levels. Tube formation experiment was conducted to detect the tube forming capability of HUVECs cells. The animal vasodilation function test detected the vasodilation functions. Ultrasonic detection was performed to determine the mouse aortic arch pulse wave velocity to identify aortic stiffness. CsV stimulus on bovine aortic cells revealed that CsV could upregulate eNOS protein levels in vascular endothelial cells in a concentration and time dependent manner. The expression levels of eNOS mRNA and phosphorylation sites Ser1177, Ser633 and Thr495 increased significantly after CsV stimulation. Meanwhile, CsV could also enhance the tube forming capability of HUVECs cells. Following the mice were gavaged using CsV, the eNOS protein level of mouse aortic endothelial cells was upregulated in a concentration- and time-dependent manner, and serum NO release and vasodilation ability were simultaneously elevated whereas arterial stiffness was alleviated. The pulldown, ChIP and dual luciferase assays demonstrated that PURA could bind to the eNOS promoter and facilitate the transcription of eNOS. Under the conditions of presence or absence of CsV stimulation, overexpression or knockdown of PURA indicated that the effect of CsV on vascular endothelial function and eNOS was weakened following PURA gene silence, whereas overexpression of PURA gene could enhance the effect of CsV upregulating eNOS expression. CsV could promote NO release from endothelial cells by upregulating the expression of PURA/eNOS pathway, improve endothelial cell functions, enhance vasodilation capability, and alleviate vessel stiffness. The present study plays a role in offering a theoretical basis for the development and application of CsV in vascular function improvement, and it also provides a more comprehensive understanding of the pharmacodynamics of CsV.

결함추출을 위한 강판튜브 엑스선 영상의 명암도 향상 (Contrast Enhancement for Defects Extraction from Seel-tube X-ray Images)

  • 황중원;황재호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.361-362
    • /
    • 2007
  • We propose a contrast-controlled feature detection approach for steel radiograph image. X-ray images are low contrast, dark and high noise image. So, It is not simple to detect defects directly in automated radiography inspection system. Contrast enhancement, histogram equalization and median filter are the most frequently used techniques to enhance the X-ray images. In this paper, the adaptive control method based on contrast limited histogram equalization is compared with several histogram techniques. Through comparative analysis, CLAHE(contrast controlled adaptive histogram equalization) can enhance detection of defects better.

  • PDF

New Empirical Approach to Enhance The Accuracy of Cannon Tube Erosion Rate

  • Chung, Dong-Yoon;Oh, Myoung-Ho
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.231-232
    • /
    • 2002
  • Various methods that utilize erosion rate measurement of standard cannon, 155mm Howitzer M185, as reference, are being used to calculate erosion rate of an interested unknown cannon tubes. We know ten measured erosion values of the standard cannon from 391 rounds to 4.000. An approximate function fitting these value s is derived. The new erosion equation is also suggested and computer simulations arc presented.

  • PDF

좁은 수평 환형 Crevice에서의 증발열전달촉진에 관한 연구 (Study on enhancement of evaporating heat transfer in narrow horizontal annular crevices)

  • 배상철;김종수
    • 대한기계학회논문집B
    • /
    • 제20권4호
    • /
    • pp.1481-1490
    • /
    • 1996
  • This study is intend to improve flow pattern within evaporator, which is low quality and low mass flux, by installing narrow horizontal annular crevice so that enhance heat transfer coefficient. The motive, which made to study heat transfer enhancement by using narrow annular crevice, came from capillary phenomena and pumping force of generating vapor on refrigerant boiling. Tests were run about 5 models of turbulence promoter with CFC-12, in the range of evaporating temperature (15.deg. C), mass flux (50 to 100 kg/m$\^$2/s), heat flux (3.4 to 6.7 kW/m$\^$2/), quality (0.1 to O.5). It is observed that flow pattern within evaporator is changed closely to semi-annular flow or annular flow, of which refrigerant liquid is reached to the upper side of tube by using narrow annular crevice. When the narrow annular crevice is installed in the evaporator tube, local heat transfer coefficient is generally more improved than that of smooth tube. That fact is according to observed result of flow pattern. It is learned that narrow annular crevice has more efficiency at a low mass flux. At the TP-5, enhancement of heat transfer rate is about 170% compare to that of smooth tube on a low mass flux (50 kg/m$\^$2/s), and it is about 134% on a high mass flux (100 kg/M$\^$2/S), so that we know that it is on a very high condition.

Sodium Amylosulfate의 Salmonella typhi 증식에 대한 영향 (Effect of Sodium Amylosulfate on the Growth of Salmonella typhi)

  • 정윤섭;김성옥;이삼열
    • 대한미생물학회지
    • /
    • 제11권1호
    • /
    • pp.27-32
    • /
    • 1976
  • Sodium amylosulfate(SAS) has been reported to be an effective substance to inactivate the anti-bacterial activity of blood in blood culture media. The advantage of the use of SAS over sodium polyanethol sulfonate(SPS) is that it does not inhibit the growth of some bacteria! species which are known to be inhibited by SPS. As to S. typhi, SPS is reported to enhance the growth, however the effect of SAS on this organism is not known as yet. Using 43 strains of S. typhi, isolated from clinical materials, the authors tried to determine the effect of SAS on this organism. The methods used for this study were : the SPS and SAS paper disk I sensitivity test, tests on the growth in trypticase soy broth(TSB) with SPS and with SAS, and experimental blood culture in SPS and SAS incorporated TSB. The following results were obtined. 1). S. typhi strains with the turbidity of No. 0.5 tube of MacFarland nepherometer were inoculated onto Mueller-Hinton plate and 1mg disk of SPS and SAS were applied. After 24-hour incubation, none of the 43 strains showed inhibition zone by SPS disk, but all of them showed zones by SAS disk with a mean zone diameter of 9.5mm(Table 1). 2) Inocula consisting of one to 54 viable counts of 37 strains were inoculated into three different media; TSB with 0.05% SPS, TSB with 0.05% SAS and TSB alone. After 24-hour incubation the mean of the optical densities of each medium were 0.483, 0.482 and 0.459 respectively, showing that SAS does not inhibit the growth of S. typhi. Moreover it was shown that there was no correlation between the amount of inocula and growth(Table 2 and Fig. 1). 3). Each set of media in 5 ml amounts consisting of one tube of TSB with 0.05% SPS, one tube of TSB with 0.05% SAS and two tubes of TSB were inoculated with 8, 64. 640 and 6400 viable counts of bacteria. Then 0.5 ml of fresh normal blood was added to all tubes except for one tube of TSB. Macroscopic observation after 24 hour incubation showed a heavy growth in all tubes except for the tube of TSB plus blood, which showed only a light growth in the tube of the heaviest inoculum. This result clearly demonstrates that the growth of S. typhi is inhibited by some antibacterial activities of fresh blood, which are counter acted by SPS and SAS(Table 3). Between SPS and SAS, there was no significant difference found(Table 4 and Fig. 2). With all these results it can be postulated that the addition of SAS into a rountine blood culture media may raise the positivity of S. typhi isolation and shorten the incubation period.

  • PDF

유튜브 여행 동영상의 긍정적 감정과 부정적 감정이 사용자 참여에 미치는 영향 (The Differential Impacts of Positive and Negative Emotions on Travel-Related YouTube Video Engagement)

  • 김희진;송하연;유진영;최성철
    • 서비스연구
    • /
    • 제13권3호
    • /
    • pp.1-19
    • /
    • 2023
  • 여행 마케팅 분야에서 브이로그와 같은 동영상 기반 소셜미디어 컨텐츠의 중요성이 높아지고 있다. 그럼에도 불구하고 시청자 반응 및 참여 행동을 향상시키는 콘텐츠 특징에 대한 연구는 제한적이다. 본 연구는 유튜브 여행 콘텐츠의 나타난 감정이 시청자 참여 행동, 특히 "좋아요"와 "댓글" 작성에 미치는 영향을 연구하였다. 본 논문에서는 방문자 수가 높은 세계 8개 관광도시에 관한 여행 관련 유튜브 동영상 4,619개의 나래이션을 머신러닝으로 추출하여 텍스트화 한 후 음이항 회귀분석을 통해 분석하였다. 그 결과 긍정 감정 및 부정의 감정 모두 "좋아요" 수에 유의한 영향을 미쳤다. 즉, 동영상에서 나타난 긍정적인 감정과 부정적인 감정이 각각 높을수록 더 많은 시청자들이 "좋아요"를 클릭하는 것으로 나타났다. 댓글 수에 측면에서는 부정적인 감정만 유의한 영향을 보인 반면 긍정적인 감정은 유의한 영향을 미치지 않는 것으로 나타났다. 본 연구는 경험재인 여행 상품의 고유한 특성을 고려할 때 유튜브에서 시청자 참여를 높이고자 하는 마케터들에게 어떠한 동영상 특징이 "좋아요"와 댓글등의 참여 행동을 유도할 수 있는지를 이해하고 전략 수립에 도움을 준다는 면에서 시사하는 바가 크다. 또한 소셜 미디어, 특히 유튜브의 맥락에서 시청자 참여도에 미치는 감정의 영향력을 검증하였다. 향후에는 감정에 대한 긍정-부정의 분류를 넘어 특정 감정이 참여도에 미치는 영향에 대한 고찰을 통해 소셜 미디어 동영상에 나타난 감정의 역할에 대한 이해를 깊이 할 수 있을 것이다.

공기 매트리스와 디지털 신호처리를 이용한 홈헬스케어용 무구속 수면 모니터링 시스템 (The Unconstrained Sleep Monitoring System for Home Healthcare using Air Mattress and Digital Signal Processing)

  • 지영준;박광석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.493-496
    • /
    • 2005
  • For home healthcare, the unconstrained measurement of physiological signal is highly required to avoid the inconvenience of users. The recording and analysis of the fundamental parameters during sleep like respiration and heart beat provide valuable information on his/her healthcare. Using the air mattress sensor system, the respiration and heart beat movements can be measured without any harness or sensor on the subject's body. The differential measurement technique between two air cells is adopted to enhance the sensitivity. The balancing tube between two air cells is used to increase the robustness against postural changes during the measurement period. The meaningful frequency range could be selected by the pneumatic filter with balancing tube. ECG (Electrocardiography) and respiration sensor (plethysmography) were measured for comparison with the signal from air mattress. To extract the heart beat information from air pressure sensor, digital signal processing technique was used. The accuracy for breathing interval and heart beat monitoring was acceptable. It shows the potentials of air mattress sensor system to be the unconstrained home sleep monitoring system.

  • PDF