• Title/Summary/Keyword: Energy variation

Search Result 2,913, Processing Time 0.044 seconds

Green and Ampt Parameter Estimation Considering Temporal Variation of Physical Properties on Tilled Soil (경운토양의 물리적 특성변화를 고려한 Green And Ampt 매개변수의 추정)

  • 정하우;김성준
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.33 no.2
    • /
    • pp.120-129
    • /
    • 1991
  • This study refers to temporal variation of physical properties of tilled soil under natural rainfalls. Field measurements of porosity, average hydraulic conductivity and average capillary pressure head on a tilled soil were conducted by soil sampler and air-entry permeameter respectively at regular intervals after tillage. Temporal variation of these physical properties were analysed by cumulative rainfall energy since tillage. Field experiment was conducted on a sandy loam soil at Suwon durging April~July in 1989. The followings are a summary of this study results ; 1. Average porosity just after tillage was 0.548cm$^3$/cm$^3$. As cumulative rainfall energy were increased in 0.1070, 0.1755, 0.3849 J/cm$^2$, average porosity were decreased in 0.506, 0.4]95, 0.468m$^3$/cm$^3$ respectively. 2. Average hydraulic conductivity just after tillage was 45.42cm/hr. As cumulative rainfall energy were increased in 0.1755, 0.2466, 0.2978, 0.3849J/cm$^2$ average hydraulic conductivity were decreased in 15.34, 13.47, 9.58, 8.65cm/hr respectively. 3. As average porosity were decreased in 0.548, 0.506, 0.495, 0.468cm$^3$/cm$^3$ average capillary pressure head were increased in 6.1, 6.7, 6.9, 7.4cm respectively. 4. It was found that temporal variation of porosity, average hydraulic conductivity on a tilled soil might be expressed as a function of cumulative rainfall energy and average capillary pressure head might be expressed as a function of porosity. 5. The results of this study may be helpful to predict infiltration into a tilled soil more accurately by considering Temporal variation of physical properties of soil.

  • PDF

Assessment of Seismic Response Spatial Variation Through the Analysis of Earthquake Records at Hamaoka Nuclear Power Plant (하마오카 원자력 발전소 지진 기록 분석을 통한 지진응답의 공간적 변화 평가)

  • Ji, Hae Yeon;Ha, Jeong Gon;Kim, Min Kyu;Hahm, Dae Gi
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.5
    • /
    • pp.181-190
    • /
    • 2022
  • In assessing the seismic safety of nuclear power plants, it is essential to analyze the structures using the observed ground motion. In particular, spatial variation in which the characteristics of the ground motion record differ may occur if the location is different within the site and even if the same earthquake is experienced. This study analyzed the spatial variation characteristics of the ground motion observed at the structure and site using the earthquake records measured at the Hamaoka nuclear power plant. Even if they were located on the same floor within the same unit, there was a difference in response depending on the location. In addition, amplification was observed in Unit 5 compared to other units, which was due to the rock layer having a slower shear wave velocity than the surrounding bedrock. Significant differences were also found in the records of the structure's foundation and the free-field surface. Based on these results, the necessity of considering spatial variation in the observed records was suggested.

A Study on the Variation of the Fretting Wear Mechanisms under Elastically Deformable Contacts

  • Lee, Young-Ho;Kim, Hyung-Kyu
    • KSTLE International Journal
    • /
    • v.10 no.1_2
    • /
    • pp.27-32
    • /
    • 2009
  • In this study, fretting wear tests of nuclear fuel rods have been performed by using two kinds of spacer grid springs with a concave and a convex shape in room temperature dry and distilled water conditions. The objectives were to examine the variation of the wear mechanism with increasing fretting cycles and to evaluate the difference of the wear debris detachment behavior at each test environment. From the test results, the wear volume of each spring condition increased with increasing fretting cycles regardless of the test environments. However, the wear rate did not show a regular tendency and apparently changed with increasing fretting cycles. This is because the formation of the wear particle layer and/or the variation of the contact condition between the fuel rod and spring surfaces could affect a critical plastic deformation for detaching the wear debris. Based on the test results, the relationship between the wear behavior of each spring shape and test environment condition, and the variation of the surface characteristics are discussed in detail.

Dose metrology: TLD/OSL dose accuracy and energy response performance

  • Omaima Essaad Belhaj;Hamid Boukhal;El Mahjoub Chakir;Meryeme Bellahsaouia;Siham Belhaj;Younes Sadeq;Mohammed Tazi;Tahar El Khoukhi;Maryam Hadouachi;Khaoula Laazouzi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.717-724
    • /
    • 2023
  • An essential step in evaluating and comparing the performance of two passive radiation dosimeter types, thermosluminescent (TLD) and optically stimulated luminescence (OSL), used by workers in environments with ionizing radiation for individual radiological monitoring and control of external exposure at various times (cumulative dose for 1 month), is to compare the measured dose accuracy, energy response, and coefficient of variation. In fact this performance study consists in determining the accuracy of both R(10) and R(0.07) which are considered as the ratios of the measured dose (Hp(10) or Hp(0.07)) to the delivered dose (Hp(10) or Hp(0.07)) for each photon energy. The validity of the results of this test is based on the acceptance limits of the ICRP and the international standard IEC-62387. The relative energy response used is normalized to the 137Cs 662 keV energy to find which energy response is closest to the ideal case, and the coefficient of variation that allows to determine the statistical fluctuation of the Hp(10) and Hp(0.07) doses. The results of the accuracy test for the OSL and TLD dosimeters are acceptable because they fall within the ICRP limits. For the energy response, the OSL performs better than the TLD for Hp(10) and Hp(0.07), and for the coefficient of variation, the OSL satisfies the requirements of ISO 62387 for both Hp(10) and Hp(0.07), while the TLD satisfies these requirements only for the measurement of Hp (0.07).

Variation Characteristics of Hourly Atmospheric Temperature Throughout a Winter (동계 시각별 외기온의 변동 특성에 관한 연구)

  • Lee, Seung-Eon;Shon, Jang-Yeul
    • Solar Energy
    • /
    • v.12 no.2
    • /
    • pp.1-8
    • /
    • 1992
  • Identifying characteristics of heating and cooling systems requires estimation of thermal load of specific time interval, especially in cases that its system is operated intermittently, by using thermal storage, of in a partial load condition. Estimating the thermal load, however, needs to forecast hourly weather data variation. Hence, this paper attempts to examine characteristics of hourly ourdoor temperature variation as a preliminary research for the mathematical modeling of the hourly weather variation. Speculating characteristics of daily minimum and maximum temperature occurances, hourly outdoor temperature variation, and daily temperature differences in the increasing range ($07h{\sim}15h$) and decreasing range($15h{\sim}07h$), we were able to analyze changing patterns of daily temperature differences in each range in terms of daily solar amount, cloud ratio, and other weather data. Results from the multiple regression analysis enables us to conclude that daily differences in the increasing range are strongly affected last night temperature itself while the other range's differences are influenced by many weather data, which are solar amount, the variation of cloud, and the maximum temperature of the previous day.

  • PDF

Electric energy harvesting using piezoelectric actuator driven by geared motor (압전 액추에이터를 이용한 에너지 수확)

  • Yun, So-Nam;Kim, Dong-Gun;Ham, Young-Bog;Park, Jung-Ho;Choi, Sang-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1463-1468
    • /
    • 2007
  • This paper presents the possibility of the electric energy harvesting using piezoelectric actuator which is operated by geared motor. The geared motor consisting of oval shape cam and speed controller was operated in the range of 40${\sim}$172rpm. The PZT actuator of $36L{\times}13W{\times}0.6H$ was used for energy harvesting and the results of the theoretical model were verified by comparing it with the measured response of a experimental setup. Experimental study for obtaining the optimal operating conditions, such as displacement variation of the PZT actuator and motor speed variation, was achieved. A power of 0.02mW at the geared motor speed of 172rpm and the PZT actuator maximum displacement of $500{\mu}m$ was measured. In this study, it was confirmed that the wind power can be used for MEMS based sensor operating and windmill health monitoring one.

  • PDF

Chemical composition and Energy contents analysis of Seven Clones of Salix hultenii as short-rotation forestry candidate (단벌기 순환림 후보 호랑버들 7 클론의 화학적 조성과 에너지 함량)

  • Shin, Soo-Jeong;Kim, Yong-Sang;Yeon, Ik-Jun;Han, Sim-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.436-438
    • /
    • 2009
  • To evaluate short rotation forestry candidates, seven clones of Salix hultenii were investigated as focused on chemical compositions and energy contents. There were significant variations in chemical compositions and energy contents among different clones. Variations in hot-water extractives content were 6.6-16.0% and 19.6-25.4% variation in lignin content. In carbohydrate compositional analysis, xylan contents were 7.5-13.1% with variation among different clones. Higher heating values were 17.69-20.02 MJ/kg.

  • PDF

A Study on the Atomization Characteristics of the Ultrasonic-Energy-Added Low Viscosity Biodiesel Blended Fuel (초음파(超音波) 에너지 부가(附加) 저 점도 바이오디젤 혼합연료(混合燃料)의 미립화 특성(微粒化 特性)에 관한 연구(硏究))

  • Song, Yong-Seek;Kim, Yong-Cheol;Ryu, Jung-In
    • Journal of ILASS-Korea
    • /
    • v.9 no.3
    • /
    • pp.1-7
    • /
    • 2004
  • This experiment was undertaken to investigate the atomization characteristics of the low viscosity biodiesel blended fuel and ultrasonic energy added one. Test fuels were conventional diesel fuel and biodiesel fuel. We compared to the characteristics of viscosity and surface tension, SMD between low viscosity biodiesel blended fuel and ultrasonic energy added one. Sauter mean diameter was measured under the variation of the spray distance. Viscosity and surface tension was measured under the variation of the time trace. To measure the droplet size, we used the Malvern system 2600C. Droplet size distribution was analyzed from the result data of Malvern system. Through this experiment, we found that the condition of the ultrasonic energy added situation had smaller Sauter mean diameter of droplet, viscosity and surface tension than that of the conventional situation.

  • PDF