• Title/Summary/Keyword: Energy usage evaluation

Search Result 85, Processing Time 0.037 seconds

An Analysis of Problems and the Current Status of Renewable Energy System in Buildings (건축물 신재생에너지원의 이용 현황 및 문제점 분석)

  • Jang, Hyang-In;Seong, Yoon-Bok;Cho, Young-Hum;Kim, Yong-Shik;Jo, Jae-Hun
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.75-82
    • /
    • 2012
  • This study aims to investigate the usage of the renewable energy systems installed in buildings and make suggestions for the effective management. In this regard, a questionnaire survey was conducted on 1)design and construction, 2) operation and management, 3) user satisfaction and improvements about the renewable energy systems in buildings. Findings from this study can be summarized as follows; a lack of the basic information about systems, non-use of energy management systems, the differences in the features by energy source, and a lack of expertise of managers. The requirements to resolved these problems include the integrated management of various electric heat sources including a renewable energy source, an operation schedule based on the prediction of production and consumption, and so on. Furthermore the necessity of multiplex energy sources management system was confirmed and the basic data needed to establish the targets of this system were obtained.

An Evaluation of Peak-Load Management in DSM Programs (부하관리 요금제 피크억제량 산정 개선방안 연구)

  • Kim, Jin-Ho;Hong, Jun-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.572-573
    • /
    • 2008
  • Demand side management can be defined as series of planning and programs to change the electric usage pattern of customers from their normal ones with a least cost while meeting customers electric demand. In general, conventional demand side management programs can be classified into two groups, one of which is a load management and the other is energy efficiency. In this paper, the load management tariff programs in Korea are explored in terms of their effect on the peak demand reduction.

  • PDF

A basic study on the Eco-friendly elements evaluation of Hanok according to G-SEED -Focus on the Unjoru and Jinwondang- (녹색건축인증제(G-SEED)에 따른 한옥의 친환경 요소 평가에 관한 기초연구 -구례 운조루와 진원당을 중심으로-)

  • Choi, Hyung-Seok;Kim, Hark-Rae
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.1
    • /
    • pp.9-18
    • /
    • 2015
  • The purpose of this study is to analyze the usage of eco-friendly elements in Korean traditional architecture to evaluate Hanok(Unjoru and Jinwondang) according to Green Building Certification Criteria(G-SEED). The results of this study were as follows; Unjoru and Jinwondang was not enough to obtain certification points. From Site usage and Traffic category, Jinwondang gets more points than Unjoru. It's because Jinwondang is located in downtown Seoul, so it gets more points of traffic and neighborhood facility. From Energy and Environmental Pollution category, Jinwondang gets more points of energy performance than Unjoru, too. It's because Jinwondang secured insulation performance of wall and windows using insulator and glass. From Resources category, Unjoru gets more points than Jinwondang. It shows that modern Hanok was limited using natural resources. From Ecological Environments category, Jinwondang is located urban area, it's difficult to secure the open space, so Unjoru gets more points than Jinwondang. If Modern Honok installs a system that can getting point and secure insulation performance, it will be certificated according to G-SEED.

A Development and Evaluation of an Web-based Apartment Buildings Energy Information System (웹 기반의 공동주택 에너지 정보시스템 개발 및 시험평가)

  • Kim, Jong-Yeob;Hwang, Ha-Jin;Lee, Jong-Sung
    • Land and Housing Review
    • /
    • v.3 no.3
    • /
    • pp.249-261
    • /
    • 2012
  • The energy use of building operational stage is about 25% of total energy supply in Korea. The intensification of insulation at the design stage and the efficient instruments were used to reduce energy use of the buildings. These efforts are limited at the energy saving side, the residents voluntarily participation in the energy-conservation is more effective. To achieve this purpose, energy use information program (of the individual users) has been developed to lead the energy users actively participating in the energy-conservation program to share at the web. Also, by investigating the necessity and the will of usage of the program and applying a pilot program, the collectability of valid data and the usability have been evaluated.

Research on Lighting Performance Evaluation for Different Curvature Reflection Rate in Residential Space (주거공간 내 광선반 곡률 형태에 따른 채광성능평가 연구)

  • Oh, Sangwon;Lee, Heangwoo;Kim, Yongseong;Seo, Janghoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.6
    • /
    • pp.328-336
    • /
    • 2015
  • Currently, 22% of the total energy consumption of buildings in Korea is used for lighting. Light-shelves have garnered attention as a way to reduce consumption, but there are few studies on the types of curve and curvature, which limits the improvement of light-shelf performance and its design. This study constructed a test bed of actual residential types to evaluate the performance. Outcomes of light usage, according to variables of light-shelves, were used as indicators of performance evaluation. The results are as follows:1) Performance evaluation was conducted on flat-type light-shelves to verify performance of curvature-shelves, which are movable with a width of 200 mm, and the most ideal angle and specification per solar term are calculated. 2) The (-) shaped curvature contributed to a reduction in energy consumption and an improvement of evenness. 3) In case of light-shelves with (-) shaped curvature, an increased angle not exceeding $80^{\circ}$ of the arc contributed to an improvement of light penetration. 4) Appropriate specifications of curved light-shelves include movable types with widths of 200 mm, and angle ranges of $20^{\circ}{\sim}60^{\circ}$. 5) Light energy consumption of a movable light-shelf with curvature and width of 200 mm were reduced by 17% and 7.8% compared to a $0^{\circ}$ fixed and a movable light-shelf, respectively.

Evaluation of hydrokinetic energy potentials of selected rivers in Kwara State, Nigeria

  • Adeogun, Adeniyu Ganiyu;Ganiyu, Habeeb Oladimeji;Ladokun, Laniyi Laniran;Ibitoye, Biliyamin Adeoye
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.267-273
    • /
    • 2020
  • This Hydrokinetic energy system is the process of extracting energy from rivers, canals and others sources to generate small scale electrical energy for decentralized usage. This study investigates the application of Soil and Water Assessment Tool (SWAT) in Geographical Information System (GIS) environment to evaluate the theoretical hydrokinetic energy potentials of selected Rivers (Asa, Awun and Oyun) all in Asa watershed, Kwara state, Nigeria. SWAT was interfaced with an open source GIS system to predict the flow and other hydrological parameters of the sub-basins. The model was calibrated and validated using observed stream flow data. Calibrated flow results were used in conjunction with other parameters to compute the theoretical hydrokinetic energy potentials of the Rivers. Results showed a good correlation between the observed flow and the simulated flow, indicated by ash Sutcliffe Efficiency (NSE) and R2 of 0.76 and 0.85, respectively for calibration period, and NSE and R2 of 0.70 and 0.74, respectively for the validation period. Also, it was observed that highest potential of 154.82 MW was obtained along River Awun while the lowest potential of 41.63 MW was obtained along River Asa. The energy potentials obtained could be harnessed and deployed to the communities around the watershed for their energy needs.

Fatigue Life Evaluation and Optimization for District Heating Pipes Considering Operating Temperature Transition Data (운전이력을 고려한 지역난방 열배관의 피로수명 평가 및 최적화)

  • Ahn M.Y.;Jung S.W.;Lee S.M.;Chang Y.S.;Choi J.B.;Kim Y.J.;Kim S.H.;Kim Y.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.581-584
    • /
    • 2005
  • A district heating(DH) system supplies environmentally-friend heat and is appropriate for reduction of energy consumption and/or air pollutions. The objectives of this paper are to systematize data processing of transition temperature, investigate its effects on fatigue life of DH pipes and optimization for size of DH pipes. A relational database management system as well as reliable fatigue life evaluation procedures is established for Korean DH pipes. Also, since the prototypal evaluation results satisfied both cycle-based and stress-based fatigue criteria. Through the optimum design process, the cross section diminished 18.64% and the CUF diminished 23.35%. So, it can be used as useful information in the future for optimal design, operation and energy saving via setting of efficient condition and stabilization of water temperature.

  • PDF

A Study on Economic Evaluation of FPL 45[W] Lamp and Ballast to Demand Side Management (FPL45[W]램프, 안정키의 전력수요관리를 위한 경제성 평가 연구)

  • Im, Song-Kug;Cho, Hyun-Kyung;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.101-107
    • /
    • 2009
  • The energy efficiency of existing lighting appliances has continuously been improving due to the government aid such as rebate programs and information of energy saving, etc. However, the usage pattern of lighting appliance at this moment has more been increasing higher illumination and indirect lighting method according that the taste of customers has changed variously. This paper estimates the economic evaluation and simulation for FPL45[W] lamp & ballast instead of FPL55 lamp & ballast in order to study the governmental support to demand side management.

(PMU (Performance Monitoring Unit)-Based Dynamic XIP(eXecute In Place) Technique for Embedded Systems) (내장형 시스템을 위한 PMU (Performance Monitoring Unit) 기반 동적 XIP (eXecute In Place) 기법)

  • Kim, Dohun;Park, Chanik
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.3 no.3
    • /
    • pp.158-166
    • /
    • 2008
  • These days, mobile embedded systems adopt flash memory capable of XIP feature since they can reduce memory usage, power consumption, and software load time. XIP provides direct access to ROM and flash memory for processors. However, using XIP incurs unnecessary degradation of applications' performance because direct access to ROM and flash memory shows more delay than that to main memory. In this paper, we propose a memory management framework, dynamic XIP, which can resolve the performance degradation of using XIP. Using a constrained RAM cache, dynamic XIP can dynamically change XIP region according to page access pattern to reduce performance degradation in execution time or energy consumption resulting from native XIP problem. The proposed framework consists of a page profiler gathering applications' memory access pattern using PMU and an XIP manager deciding that a page is accessed whether in main memory or in flash memory. The proposed framework is implemented and evaluated in Linux kernel. Our evaluation shows that our framework can reduce execution time at most 25% and energy consumption at most 22% compared with using XIP-only case adopted in general mobile embedded systems. Moreover, the evaluation shows that in execution time and energy consumption, our modified LRU algorithm with code page filters can reduce more than at most 90% and 80% respectively compared with applying just existing LRU algorithm to dynamic XIP.

  • PDF

Performance Evaluation of Truck Haulage Operations in an Underground Mine using GMG's Time Usage Model and Key Performance Indicators (GMG 시간 사용 모델 및 핵심성과지표를 이용한 지하 광산 트럭 운반 작업 성능 평가)

  • Park, Sebeom;Choi, Yosoon
    • Tunnel and Underground Space
    • /
    • v.32 no.4
    • /
    • pp.254-271
    • /
    • 2022
  • The performance of truck haulage operations in an underground mine was evaluated using the time usage model and key performance indicators (KPIs) proposed by Global Mining Guidelines Group (GMG). An underground mine that mainly produces iron and titanium iron was selected as a study area, and truck haulage data were collected using Bluetooth beacons and tablet PCs. The collected data were analyzed to identify unit operations, activities, events, and required time of truck haulage operations, and time categories were classified based on the time usage model. The performance of the haulage operations was evaluated using nine indicators in terms of availability, utilization, and effectiveness. As a result, in terms of availability, uptime was 33.9%, physical availability was 95.7%, and mechanical availability was 94.9%. In the case of utilization, use of availability was 83.1%, asset utilization was 28.1%, and operating and effective utilization were 79.6% and 77.7%, respectively. Also, in terms of efficiency, operating efficiency was high at 97.6%, and production effectiveness was found to be 49%.