• Title/Summary/Keyword: Energy supplied

Search Result 742, Processing Time 0.024 seconds

Experimental Study on Thermal Performance of Palte-type Fresh Water Generator for applying Solar Energy Desalination System (태양에너지 해수담수화시스템에의 적용을 위한 판형 해수담수기의 열성능에 관한 실험적 연구)

  • Kim, Jeong-Bae;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.35-41
    • /
    • 2007
  • To demonstrate the desalination system, the demo-plant was scheduled to be installed. The system was planned to use solar thermal collector as heat source and PV as electricity source. For the design of the desalination demonstration system, firstly the solar thermal system would be well designed from the result between the supplied heat into the fresh water generator and the fresh water yield. The generator for demonstration system was chosen as the fresh water generator of the single stage and effect with plate-type heat exchanger using low pressure evaporation method. The test facility for the tests to reveal the relationship between the fresh water yield and the supplied heat flow rate was designed and manufactured. The maximum fresh water yield of two fresh water generators applied in this study was designed as 1.5 Ton/day. The parameters relating with the performance of fresh water generator are known as sea water inlet temperature, hot water inlet temperature, and hot water flow rate. Through the experiments, this study firstly showed detail operation characteristics of the generator and designed the solar thermal system for the demonstration system.

Basic Operational Characteristics for Developments of Solar Air Heater for Air Heating in Winter (태양열 이용 난방용 공기가열기 개발을 위한 기초 운전 특성)

  • Kim, Jong-Ryeol;Hong, Boo-Pyo;Woo, Jong-Soo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.87-94
    • /
    • 2011
  • To develop the solar air heater, prototype of solar heater with test room set up on the roof of test chamber and operation characteristics were examined with solar radiation. Air induced from outside was supplied by a blower and also heated air was supplied to the test chamber(size of 1,000mm(inwidth)*2,000mm(in length)*2,000mm(in depth)) established already for performance. It was clear that almost 30% of solar radiation was converted into effective heating energy at maximum and the highest air temperature was $46^{\circ}C$, and thus solar air heater in winter could be used as an possible alternative heating system in building. Furthermore, heat energy obtained from solar air heater can be applied to regenerate absorber in the solar desiccant cooling system.

Upward and Lateral Translocation of $^32 P$ Supplied to Roots of Apple and Citrus Tress

  • Shim, Kyung-ku;Chung, Kyu-Hoi;Kwon, Shin-Han
    • Nuclear Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.139-143
    • /
    • 1976
  • $^{32}$ P was supplied to the roots of stem-ringed 1-year-old apple trees and 2-year-old citrus trees on which bark segments were isolated above and below the ring. $^{32}$ P was translocated to shoots and leaves although considerable translocation occurred especially in wood and bark tissues. The accumulation of $^{32}$ P in isolated bark segments indicated that the occurrence of these materials in this tissue was via radial translocation from xylem tissue, and that the main upward translocation pathway of $^{32}$ P supplied to roots is through the xylem.

  • PDF

Case Study on the Energy Consumption Unit of District Apartments (지역난방 공동주택의 에너지원별 원단위 사례분석)

  • Lee, Wang-Je;Kang, Eun-Chul;Lee, Euy-Joon;Oh, Byung-Chil;Shin, U-Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.10
    • /
    • pp.474-480
    • /
    • 2014
  • This study investigated the total energy consumption and the energy consumption by type of 31 apartment complexes in Daejeon. The energy is supplied to the apartments from district heating, and can be divided into hot water, electricity, and gas. Hot water is used in for space heating and for domestic hot water (DHW), and electricity is used for plugs, cooling, ventilation, and public utilities (street lights, pumps, elevators, etc.). All gas supplied from district heating is used for cooking. As a result, the consumption unit of each energy source of independent dwelling areas was calculated to be $103.7kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$) for thermal energy, $48.0kWh/m^2{\cdot}a$ ($4,646kWh/H{\cdot}a$) for electricity, and $10.5kWh/m^2a$ ($1,015kWh/H{\cdot}a$) for gas, so the entire consumption was calculated to be $162.3kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$).

Development of Biomass Gasification System Using a Downdraft Gasifier (하향류식 가스화기를 이용한 바이오매스 가스화 시스템 개발)

  • Son, Young-Il;Yoon, Sang-Jun;Choi, Young-Chan;Kim, Yong-Ku;Ra, Ho-Won;Lee, Jae-Goo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.662-665
    • /
    • 2007
  • Since biomass is given the status of "renewable resource" in contrast to "exhaustible resource" e.q., fossil fuels, it plays a significant role in the sustainable development in future. We installed a downdraft gasifier for power generation from biomass materials. The biomass raw materials were wood chips with a moisture content of 18-23 wt.%, supplied at 40-50kg/h. This paper describes on the optimum gasification air ratio that is defined as the ratio of the oxygen mole supplied into the gasifier to the oxygen mole required for complete combustion for producing syngas supplied into a gas engine. The results showed that, lower heating value of the syngas was 1200 $kcal/m^3$ $_N-dry$ and cold gas efficiency of the gasification system was 72% under optimum operating conditions.

  • PDF

The Experimental Research On The Electrical Characteristics For The Ignition Of Plasma Jet Using The Advance Discharge Of High Frequency Voltage With Attenuation (감쇠파 고주파전압의 선행방전을 이용한 Plasma jet의 전기적 기동특성에 대한 실험적 연구)

  • Choon Saing Jhoun
    • 전기의세계
    • /
    • v.21 no.4
    • /
    • pp.27-38
    • /
    • 1972
  • This paper discusses the characteristics about the ignition of D.C. main discharge is a plasma jet generator, manufactured for trial as non-transferred type, when the electrical energy appropriate to the ignition is supplied to the gap between the electrodes by using advance discharge of attenuating high frequency voltage generated by a high frequency oscillator with mercury spark gap. These characteristics are under the influences of (a) the length of mercury gap in high frequency oscillator and the quantity of hydrogen flow supplied to it, (b) the condenser capacity of the high frequency oscillator circuit, (c) the length of plasma jet torch in D.C. main discharge circuit and the quantity of argon flow supplied to it, (d) the circuit constants of D.C. main discharge circuit. The results for these characteristics, obtained by this research, are considered to be helpful to the designs for the ignition of a plasma jet as well as the welding arc stabilizer by high frequency discharge and the high frequency arc welder.

  • PDF

Performance Test of Supercharger for Vehicle using Solar Cell (태양광발전 방식의 자동차용 과급 장치의 성능 평가)

  • Ko, Kwang-Ho
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.942-948
    • /
    • 2011
  • The performance of a supercharger for vehicle using solar cell attached on the exterior of a car, an auxiliary battery, and an air compressor was evaluated in this study. This supercharger is composed of a solar cell of 40W, a battery of 60 Ah, an air compressor of 17 A, 8 $kgf/cm^2$ and an air tank of 8L. It takes about 6 days to charge the battery with the solar cell and the high pressure air of 8L can be supplied about 70 times to engine intake with this battery. The intake pressure increased by about 20~40% with this supercharger. The vehicle power and accelerating performance are enhanced by 87% and 50% each in the low speed range. But the performance improved little in the high speed range because of the rather constant flow rate of air supplied by this type of supercharger.

The Effects of Operating and Design Conditions on the Performance of Radiant Heating Panel (복사 난방 패널의 공급유량 및 설계변수가 성능에 미치는 영향)

  • Lee, Tae Won;Kim, Ho Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.4
    • /
    • pp.276-285
    • /
    • 1991
  • The transient heat transfer characteristics in the radiant heating panel were predicted by numerical analysis. Thermal behaviors of panel, such as temperature distributions in panel and convective and radiative heat fluxes in panel surface with respect to time were obtained. Heating hours per day, rate of energy supplied and maximum temperature differences at panel surface were also compared for several important parameters. The performance and thermal comfort of heating panel were studied and compared for various operating and design conditions such as pipe pitch, pipe location, pipe diameter and flow rate of hot water for the purpose of producing useful data, which can be used for the test and decision of efficient operating condition of the conventional heating systems or the optimal design of the new panel heating systems.

  • PDF

Circulation Effect of the Transparent Insulated Opaque Envelopes (투명 단열외피를 통한 환기효과에 관한 연구)

  • Kim, S.H.;Kim, S.J.;Lee, S.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.31-43
    • /
    • 2000
  • A model house with a "Ondol" heating working with solar energy and supplied by circulation air was investigated both experimentally and theoretically, A calculation method was developed for interpreting the measured values and for comparing several variants, This calculation method together with the measurement result is presented in the following. The gain in energy of the collector(Trombe wall type with TWD) measured on a particularly selected winter day with plenty of radiation amounted to approximately 31 % of the total solar radiation.

  • PDF

Characteristics and Limitations of Green Premium in the Korean RE100 System (한국 RE100 제도에서 녹색프리미엄의 특성 및 한계)

  • Yang, Wonchang;Lee, Jae-Seung
    • New & Renewable Energy
    • /
    • v.18 no.3
    • /
    • pp.43-59
    • /
    • 2022
  • The green premium is the most important feature of Korea's RE100 system. Green premium has three characteristics. The first, the cost of implementation is lower than that of other means of implementation. The second, it is linked with the RPS system to keep the means of implementing the green premium low. Third, the funds raised by the green premium are used to supply renewable energy to compensate for the additionality that the green premium does not have. When the entire industrial sector's electricity consumption is converted to renewable energy, the implementation cost of the green premium is estimated to be 3,377.4 billion won, and the REC purchase is estimated to incur the implementation cost of 6,576.4 billion won, which is 3.5 trillion more than the green premium. It was analyzed that an additional implementation cost of KRW 100 million would occur. In addition, in the case of solar PPA, it was analyzed that additional implementation costs of KRW 13,375.7 billion to KRW 16,162.3 billion were incurred. It was estimated that the renewable energy that could be supplied to the green premium would at least be sufficient for companies exporting to the US and EU. In addition, it was analyzed that when the fund created as a green premium is used for renewable energy supply, about 30.7% of the renewable energy supply through PPA can be supplied. However, as ESG is emphasized, green premium can be criticized by green washing because there is no additionality. There is also a limit to responding to the EU's CBAM. Therefore, companies can use the green premium depending on the situation, but it is more advantageous to use PPA, etc. The government needs to sufficiently maintain the supply of renewable energy using the fund to maintain the green premium.