하수처리시설의 에너지자립화 및 경제적 효과분석 (Study on Energy Independence Plan and Economic Effects for Sewage Treatment Plant)

  • 박기학;이호식;하준수;김극태;임채승
    • 한국물환경학회지
    • /
    • 제37권2호
    • /
    • pp.128-136
    • /
    • 2021
  • It is generally known that a wastewater treatment plant (WWTP) consumes immense energy even if it can produce energy. With an aim to increase the energy independence rate of WWTP from 3.5% in 2010 to 50% in 2030, the Korean government has invested enormous research funds. In this study, cost-effective operating alternatives were investigated by analyzing the energy efficiency and economic feasibility for biogas and power generation using new and renewable energy. Based on the US EPA Energy Conservation Measures and Korea ESCO projects, energy production and independence rate were also analyzed. The main energy consumption equipment in WWTP is the blower for aeration, discharge pump for effluent, and pump for influent. Considering the processes of WWTP, the specific energy consumption rate of the process using media and MBR was the lowest (0.549 kWh/㎥) and the highest (1.427 kWh/㎥), respectively. Energy-saving by enhancing anaerobic digester efficiency was turned out to be efficient when in conjunction with stable wastewater treatment. The result of economic analysis (B/C ratio) was 2.5 for digestive gas power generation, 0.86 for small hydropower, 0.49 for solar energy, and 0.15 for wind energy, respectively. Furthermore, it was observed that the energy independence rate could be enhanced by installing energy production facilities such as solar and small hydropower and reducing energy consumption via the replacement of high-efficiency operating.

암반 저장창고 건설을 통한 에너지 절감과 장기보존에 대한 연구 (A study of energy saving and long conservation in construction of rock store house)

  • 최예환;채경희
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.210-216
    • /
    • 1998
  • The most important thing to consider in cold store design are to save cooling energy consumption and to keep goods freshly. Specially there are many efforts to save energy with cold store in Korea. A building energy simulation program should be used to optimally select a cooling system to match the criteria of cooling rate and storage rate in a given cool crop storage building and HVAC system. The low maintenance costs, high degree of safety and environmental impacts are also favouring the underground solution. There are obviously a lot of possibility for cost-effective storage of cooled or frozen goods or liquids in ground water rock.

  • PDF

A trust evaluation method for improving nodes utilization for wireless sensor networks

  • Haibo, Shen;Kechen, Zhuang;Hong, Zhang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권3호
    • /
    • pp.1113-1135
    • /
    • 2018
  • Existing trust evaluation models for wireless sensor networks can accurately and objectively evaluate trust value of nodes, but the nodes' energy saving problem was ignored. Especially when there are a few malicious nodes in a network, the overall trust value calculation for all nodes would waste lots of energy. Beside that, the network failure caused by nodes death was also not considered. In this paper, we proposed a method for avoiding energy hole which applied trust evaluation models and a trust evaluation method based on information entropy, so as to achieve the purpose of improving nodes utilization. Simulation results show that the proposed method can effectively improve nodes utilization, and it has reasonable detection rate and lower false alert rate compared to other classical methods.

고속버스의 환기구 형태에 따른 환기량 분석 (Analysis on the Ventilation Rate of Express Bus according to the Geometry of Vent)

  • 신인환;유호천
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.174-178
    • /
    • 2011
  • This paper deals with the free cooling system of express bus using natural energy source in order to improve the room air quality and save cooling energy. In an express bus, there are may passengers in unit area, requiring the improvement of air quality and giving higher energy saving efficiency. Particularly, the express buses running fast make it easy to take in outdoor air at a flow rate controllable with a damper mechanism. This paper proposes the analysis on the air flow achieved by a damper controlled vertically and horizontally in order not to deteriorate the ride comfort of the passengers.

  • PDF

전기요금 절감 측면에서 에너지저장시스템의 운전알고리즘 (Operation Algorithm of Battery Energy Storage System (BESS) for Saving Electric Charges)

  • 김응상
    • 에너지공학
    • /
    • 제8권4호
    • /
    • pp.519-524
    • /
    • 1999
  • 본 논문에서는 1 MW 에너지저장시스템을 특별 고압 수용가에 설치하여 실 계통과의 계통연계 운전시 대상 수용가의 전기요금의 절감을 위한 운전알고리즘을 제안하였다. 제안된 운전 알고리즘을 이용하여 계통연계 운전시 '97년도의 1년 동안 전기요금과 '98년도에는 '97년도와 똑같이 전기를 사용한다는 가정하에 계절별, 시간대별 및 역률 조정운전을 고려하여 적용하였다. 적용결과 1 년동안 약 4 천만원 정도의 종합 전기요금 절감이 기대되었으며, 이상의 결과로부터 본 논문에서 제안된 알고리즘의 유효성을 입증할 수있었다.

  • PDF

온기의 가치평가 및 난방비 배분방법론 제안 (A Suggestion for the Worth Evaluation of Warm Air and the Allocation Methodology of Heating Cost)

  • 김덕진
    • 설비공학논문집
    • /
    • 제20권10호
    • /
    • pp.654-661
    • /
    • 2008
  • Our government will make a plan regulating the cooling limit temperature of the summer season to 26 degree and the heating limit temperature of the winter season to 20 degree for energy saving. Where, the key point of this politic pursuit can be the charge system on heating and cooling cost. Currently, the heating and cooling cost are charged as much as the volume or heat flow rate regardless of the high and low room temperature. However, we have suggested new cost estimating methodology as a worth method in the precedent study, and preformed the worth evaluation and cost allocation of electricity and heat on various cogenerations. In this study, we applied the suggested worth method to four kind of warm air, and preformed the worth evaluation and cost allocation of each warm air. As a result, the more energy a customer saved, the more heating unit cost decreased, and the more energy a customer consumed, the more heating unit cost increased. From this analysis, we hope that the suggested worth methodology can offer a theoretical basis to the politic pursuit of government, and induce the spontaneous energy saving of consumers.

바닥 복사 난방 시스템의 제어전략에 따른 에너지 사용량 분석 (Energy Saving Potentials of Radiant Floor Heating Systems Based on Control Strategies)

  • 이준우;박철수
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.109-114
    • /
    • 2009
  • The dominant heating system used in Korean residential apartment buildings is a hydronic radiant floor heating system, known as the Ondol system. The most common control strategy applied to this traditional hydronic radiant system is a simple on-off control that intermittently supplies "hot water of a fixed temperature" at a "constant flow rate" to each room. However, the current problems with the aforementioned control are as follows: (1) since the simple on-off control is usually based on a one point measured temperature (a signal from a thermostat installed in a living room) in each dwelling unit, heating energy use for unoccupied rooms as well as a difference in temperatures between spaces (master bedroom, living room, bedroom1, bedroom2) can occur occasionally. (2) the most widely used residential water splitter has static valves, and is thus not able to change the flow rate to each room depending on the space heating load. In other words, the ratio of flow rates to rooms is fixed after construction, resulting in over- or under-heating and an improper use of energy. The aim of this paper is therefore to investigate the differences in the system's performance between control strategies in terms of the flow rate control and sensor location. It is shown that energy savings of control strategies are strongly influenced by occupant schedule.

  • PDF

외기냉방시스템이 적용된 데이터센터 CRAH의 급기온도와 설계 풍량에 따른 에너지성능 분석 (Energy Performance of Air-side Economizer System for Data Center Considering Supply Temperature and Design Airflow Rate of CRAH(Computer Room Air Handler))

  • 김지혜;엄태윤;정차수
    • 대한건축학회논문집:구조계
    • /
    • 제35권11호
    • /
    • pp.181-188
    • /
    • 2019
  • The purpose of this study is to evaluate the cooling energy saving effects of CRAH supply air temperature(SAT) and design flow rate changes when applying air-side economizer in the data center. MLC(Mechanical Load Component), which is cooling performance indicator of data center, was used to assess the effectiveness of cooling energy savings. It was computed with energy simulation (DesignBuilder) to evaluate the cooling energy performance of 8 different alternatives in a data center. The MLC was 0.31~0.32 regardless of CRAH supply temperature without air-side economizer, and 0.15 to 0.19 value with air-side economizer. That is, cooling energy can be reduced by approximately 40~55% when applying economizer. As the CRAH SAT and design flow rate changed, the MLC values were 0.16 to 0.18 and 0.15 to 0.19, respectively.

도시철도시스템용 에너지저장시스템 용량설계에 관한 연구 (A Study on Capacity Design of Energy Storage System for Urban Transit System)

  • 이한민;김길동;이장무
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.697-700
    • /
    • 2007
  • Six thousands of vehicles are operated on Korean urban transit system. 95% of them have regeneration system. Especially, the VVVF-Inverter vehicle has a merit of the highest regeneration rate. Therefore, the energy storage system is needed to be developed to use regeneration energy when the vehicle is braking. Therefore, Measuring regeneration energy in the substation need to know how much regeneration energy occurs, how much capacity of energy storage system is needed. After measuring regeneration energy, we design the capacity of energy storage system.

  • PDF

MAC Protocols for Energy Harvesting Wireless Sensor Networks: Survey

  • Kosunalp, Selahattin
    • ETRI Journal
    • /
    • 제37권4호
    • /
    • pp.804-812
    • /
    • 2015
  • Energy harvesting (EH) technology in the field of wireless sensor networks (WSNs) is gaining increasing popularity through removing the burden of having to replace/recharge depleted energy sources by energy harvester devices. EH provides an alternative source of energy from the surrounding environment; therefore, by exploiting the EH process, WSNs can achieve a perpetual lifetime. In view of this, emphasis is being placed on the design of new medium access control (MAC) protocols that aim to maximize the lifetime of WSNs by using the maximum possible amount of harvested energy instead of saving any residual energy, given that the rate of energy harvested is greater than that which is consumed. Various MAC protocols with the objective of exploiting ambient energy have been proposed for energy-harvesting WSNs (EH-WSNs). In this paper, first, the fundamental properties of EH-WSN architecture are outlined. Then, several MAC protocols proposed for EH-WSNs are presented, describing their operating principles and underlying features. To give an insight into future research directions, open research issues (key ideas) with respect to design trade-offs are discussed at the end of this paper.