• Title/Summary/Keyword: Energy saving rate

Search Result 326, Processing Time 0.023 seconds

A study on the application of recuperative burner system to a teeming ladle (티밍래들에 폐열회수버너의 적용)

  • 양제복;정대헌;김원배
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1998.10a
    • /
    • pp.180-192
    • /
    • 1998
  • One of the conventional gas burners has nowadays been used for ladle preheating. As a ladle is one of the open-type furnaces, however, it causes to consume much fuel because of high temperature of exhaust gas from the ladle and the exhaust gas passing through ladle cover makes it worsen a working environment nearby. Therefore, the objective of this study is to develop the recuperative burner system applying for an existing teeming ladle , which is integrated with burner, recuperator and eductor as one of the new type combustion equipments and has many advantages of simple installation, compactness and easy control, especially a great deal of energy saving through the waste heat recovery from exhaust gas. The contents of the study is to design, manufacture of recuperative burner system and to perform its tests experimentally after applying to the teeming ladle in the capacity of 100 ton. Its heat release rate is 1,700,000 kcal/h with COG(Cokes Oven Gas) as fuel gas. The test items are the temperature distribution inside the ladle and the preheated air temperature change depending upon the exhaust gas. Nox, exhaust gas analysis and noise.

  • PDF

A Study on Improved Operation of Apartment Heating System in a Machine Room (공동주택 기계실 난방설비 운전 개선 연구)

  • Seo, Jeong-Ah;Shin, Younggy;Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.38-42
    • /
    • 2017
  • This study proposes an idea for energy saving in apartment machine rooms. A conventional district heating system is equipped with constant-flow pumps and bypass valves to regulate pump differential pressure. Each family unit is equipped with a constant-flow on/off valve. This leads to excessive hot water circulation and a high return temperature. To reduce energy loss, this study assumes that each family unit is renovated with a heating valve which regulates the return temperature at $35^{\circ}C$. The hot water supply pump is also replaced with a pump with an inverter to vary flow rate. Expected energy savings is then estimated from field test data. According to the results, pump electricity consumption was reduced by 6,100 kWh for a family unit building over about half a year. The supply temperature can also be lowered by $5^{\circ}C$, which can contribute to a production of electricity of 10.3 kWh/ton of hot water.

Cooling Cycle for Energy Saving (에너지 절약용 냉방사이클)

  • Lee, Hung Joo;Kim, Yong Ku
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.2
    • /
    • pp.116-127
    • /
    • 1989
  • Research on reheating cooling cycle and its practical application have been made to prevent unequalized distribution of temperature and humidity of room due to lack of supply air volume and dewdrops on supply diffusers to be taken place as a result of lower temperature of supply air than that of dew point of room air in cooling cycle of constant air volume, single duct, single zone and draw-through fan type. In view of the fact that human body is insensitive to humidity, it is possible not only to construct the complete non-reheating cooling cycle by increasing the humidity point allowable with the deduction of occupant's sense of pleasantness minimizing, but also to get cooling cycle decreasing the reheating quantity if the humidity exceeds the point allowable. In addition, it is possible to save maximum 8% in electric energy for cooling in cooling system by constructing non-reheating cooling cycle instead of reheating cooling cycle and by increasing the relative humidity of room from 50% to 65% in case efficiency and air pressure of cooling system are low. It is also possible to get an optimum cooling cycle by determining the room humidity in consideration of pleasantness of occupants and conservation rate of electric energy if the cooling capacity, efficiency and total pressure of cooling equipment are fixed.

  • PDF

Efficient Transmission Schemes in UWB Based Ship Area Networks (UWB기반 선박 네트워크에서 효율적인 전송 기법)

  • Kim, Jin-Woo;Kwon, Jang-Woo;Jeong, Min-A;Lee, Seong Ro
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.11
    • /
    • pp.1151-1158
    • /
    • 2014
  • In this paper, a concatenated frame algorighm for improving transmission efficiency in WiMedia protocol is studied. And an efficient transmission scheme to reduce the degradation of network performance by the loss of mini-frame is proposed in this paper. The proposed scheme can reduce total energy consumption and improve the transmission efficiency since it only retransmits mini-frame in which error is occurred. The simulation results show that proposed protocol can enhance the throughput performance and improve energy efficiency by minimizing the retransmission of mini-frame.

Comparative Study on Performance of Wet-type and Dry-type Floor Heating Systems Using Geothermal Heat Pump (지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구)

  • Lee, Byoung-Doo;Lee, Se-Jin;Lee, Dae-Woo;Oh, Sung-Hae;Nam, Woo-Dong
    • New & Renewable Energy
    • /
    • v.5 no.4
    • /
    • pp.60-65
    • /
    • 2009
  • The present study was conducted for a comparative evaluation of wet and dry floor heating systems using geothermal heat pump. We circulated hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.9^{\circ}C$ for wet type and $32.7^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. As a result, in case of floor heating system using low temperature circulation water, dry type was more practicable for stable floor heating than wet type in terms of floor temperature and access time to indoor set temperature.

  • PDF

Desulfurization efficiency in photobioreactors dependent on the irradiation type of light sources (광생물반응기내 광조사 유형별 탈황 효율)

  • An, Jin Young;Kim, Byung Woo
    • Clean Technology
    • /
    • v.6 no.1
    • /
    • pp.71-78
    • /
    • 2000
  • Removal rates of hydrogen sulfide were investigated to known effects of several light sources with external and internal irradiation on the desulfurization using C. thiosulfatophilum. In the case of internal illumination system, optical-fiber photobioreactor was applied to increase the light availability. Furthermore, sunlight was used as the main light energy in the daytime and metal-halide lamp was applied as an additional light energy at night. Light energy of 99% was saved by the application of the LED's array in comparison with the incandescent light source. $H_2S$ removal rates at 5,000 lux in a 4-L photobioreactor were shown as 0.040, 0.138, 0.136, and 0.134 (${\mu}mol$ $H_2S/min$)/(mg protein/L), respectively, in the following order of light sources, when several light sources such as fluorescent, energy-saving, incandescent, halogen lamp, and filtered light at 460 nm were applied. Removal rate per unit cell concentration with the internal light diffused optical-fibers increased about 1 six times as much as that with the external light sources. Removal rate per unit cell concentration, using sunlight in the daytime and a metal-halide lamp at night, was 0.41 less than 0.869 (${\mu}mol$ $H_2S/min$)/(mg protein/L) using a 400 W metal-halide lamp day and night, since the automatic sunlight collection system can transmit the light intensity as only 10% of that with a metal-halide lamp.

  • PDF

Performance Analysis for Regenerative Energy Storage System in Kyoung-bu High Speed Railway (경부고속철도 회생 에너지 저장시스템 성능 분석)

  • Jang, Min-Ju;Jeon, Yong-Joo;Lho, Young Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1391-1397
    • /
    • 2015
  • Recently, various researches are conducted in the application of regenerative energy produced during the operation of an electric locomotive. Regenerative energy is produced by a generator in the brake procedure. The generator is operated by kinetic energy of an electric railroad using an electric motor. The process of producing regenerative energy varies with the current type of a railroad and its running condition. The quality of electric power can be improved and electric energy can be utilized effectively, especially in the use of an energy storage system (ESS). Thus, it is necessary to apply ESS into AC section and high speed railway. This study analyses the composition of the regenerative ESS equipment installed in Yong-Jeong sectioning post, operational principle, charge and discharge algorithm and energy efficiency. The analysis shows that CO2 emissions can be reduced about 0.5 ton per a day. In addition, ESS helps saving the energy and the compensation of the voltage drop caused by the operation of high speed train when it is installed at the end of the feeder section. The number of high speed train will be increased continuously related to the electrification rate. Therefore, applying the ESS to high speed railway is expected to solve the instability of the feeder voltage and the equipment capacity problem caused by the high speed trains.

Reuse of Exhaust Heat and Improvement in Fuel Efficiency of Grain Dryer (곡물(穀物) 건조기(乾燥機)의 배기열(排気熱) 재이용(再利用) 및 열효율(熱効率) 개선(改善)에 관(關)한 연구(硏究))

  • Keum, Dong Hyuk;Lee, Yong Kook;Lee, Kyou Seung;Han, Jong Ho
    • Journal of Biosystems Engineering
    • /
    • v.9 no.2
    • /
    • pp.65-73
    • /
    • 1984
  • While most of researches on the performance of high temperature grain dryer have dealt mainly with improving dryer capacity and drying speed during the last twenty years, energy efficiency, in fact, has not been emphasized. Current fuel supplies and energy cost have shifted the emphasis to reducing the energy consumption for grain drying while maintaining dryer capacity and grain quality. Since the energy input for drying is relatively large, the recovery and reuse of at least part of the exhaust energy can significantly reduce the total energy consumption in existing drying systems. Unilization of exhaust heat in grain dryer either through direct recycling or by a thermal coupling in heat exchanger have been subject of a number of investigators. However, very seldom research in Korea has been done in this area. Three drying tests(non-recycling, 0.22 recycle ratio, and 0.76 recycle ratio)were performed to investigate the thermal efficiency and heat loss factors of continuous flow type dryer, and to analyze the effect of recycle ratio (weight of exhaust air recycled/total weight of input air) on the energy requriements for rough rice drying. The test results showed that when the exhaust air was not recycled, the energy lost from furnace was 15.3 percent of input fuel energy, and latent and sensible heat of exhaust air were 61.4 percent and 11.2 percent respectively. The heat which was required in raising grain temperature and stored in dryer was relatively small. As the recycle ratio of exhaust air was increased, the drying rate was suddenly decreased, and thermal efficiency of the kerosene burner was also decreased. Drying test with 0.76 recycle ratio resulted in 12.4% increase in fuel consumption, and 38.4% increase in electric power consumption as compared to the non-recycled drying test. Drying test of 0.22 recycle ratio resulted in 6.8% saving in total energy consumption, 8.0% reduction in fuel consumption, and 2.5% increase in electric power consumption as compared to the non-recycled drying test.

  • PDF

Study on the Fueling Economic Feasibility of Plug-in Hybrid Electric Vehicle (플러그인 하이브리드 전기자동차의 연료 경제성에 관한 연구)

  • Roh, Chul-Woo;Kim, Min-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.4
    • /
    • pp.255-263
    • /
    • 2009
  • The most concerning issue of these days is the energy crisis caused by increasing threat of dependence on imported oil and volatile market trend. Under these circumstances, the PHEV(plug-in hybrid electric vehicle) is drawing attention for the next generation's car which could give a chance to decrease the dependence on imported oil and reduce the environmental impact of vehicle. The fueling cost of PHEV, one of the core factor of decision about buying car, should be calculated in the circumstances of Korea to make sure that PHEV has competitive power in real market. The fuel cost saving of PHEV versus CV(conventional vehicle) is simulated and discussed in the condition of increasing gasoline cost, electricity rate, and city-gas rate. In conclusion, the PHEV60-FS shows the best economic feasibility when gasoline price goes up. The PHEV20 has the most stable economic feasibility as electricity rate increases. The fuel cell cogeneration system for RPG could be an alternative for charger of PHEV in the near future.

The Effects of Electro-Osmosis and Compression on the Dewatering of Agricultural Wastes (고함수 농산폐기물의 탈수과정에서 전기침투와 압력의 효과)

  • 김영중;윤진하;이운용
    • Journal of Biosystems Engineering
    • /
    • v.21 no.1
    • /
    • pp.52-59
    • /
    • 1996
  • In this study, the combined forces of electro-osmosis and compression were applied to cabbage dewatering and their effects were discussed. Nine treatments of combined forces consisting of three levels of voltage and compression were applied to chopped and macerated chinese cabbage placed in the experimental set-up consisted of cylinder-piston. The results showed that as both voltage and pressure increased the dewatering rates increased and the combined force of voltage and compression was a very effective means in the dewatering of chinese cabbage in which the largest dewatering rate difference, 72%, was found between the combined force of 30V with 68.2kPa and no voltage(0V) with 68.2kPa. However, no significant difference was found between the voltage of 0 and 10volts in 9.75kPa and the pressure of 68.2kP and 126.7kPa in 30volts. The maximum and minimum dewatering rate were 82% in the combined force of 30 volts of 126.7kPa and 8% in 0 volt of 9.75kPa, respectively. Within the experimental trials, it appeared that the best treatment combination would be pressure of 68.2kPa and voltage of 30V producing dewatering rate of 80ft in which the produced liquid contained about 1% solid. Employing this dewatering method as a pretreatment before drying process can contribute in considerable energy saving in agricultural wastes treatment.

  • PDF