• Title/Summary/Keyword: Energy requirement

Search Result 973, Processing Time 0.026 seconds

Dietary Self-selection and Nutrient Feeding Systems for Egg-type Growing Pullets and Layers (난용계의 선택채식과 영양소 공급체계)

  • 이규호
    • Korean Journal of Poultry Science
    • /
    • v.21 no.2
    • /
    • pp.101-111
    • /
    • 1994
  • From the observations of dietary self-selection by growing pullets, step-up protein or reverse protein and single-stage low protein pullet feeding systems were developed. They offered another pullet feeding concept that appears to control the body weight effectively and to reduce the consumption of feed and nutrients without impairment of subsequent laying performance. It is obvious from the feed and nutrient consumption pattern of layers fed diets for self-selection of energy, protein and calcium that they have a daily cyclic requirement rather than a constant requirement for nutrients. It seems that a practical self-selective feeding system is needed to meet the daily cyclic requirement for nutrients without consuming an excess of energy and protein at certain times of the day as compared to the complete or single diet where layers have to consume extra energy and protein in the afternoon when they have a specific appetite mainly for calcium.

  • PDF

Development of an Energy Model of Rice Processing Complex(II) -Simulation Model Development and Analysis of Energy Requirement- (미곡종합처리장의 에너지 모델 개발(II) -시뮬레이션 모델 개발 및 소요 에너지 분석-)

  • 장홍희;장동일;김만수
    • Journal of Biosystems Engineering
    • /
    • v.20 no.3
    • /
    • pp.275-287
    • /
    • 1995
  • The rice processing complex(RPC) consisted of the rice handling, drying, storage, and milling processes. It has been established at 83 locations domestically by April 1994, and 200 of RPC will be built more throughout the country. Therefore, this study has been performed to achieve two objectives as the followings : 1) Development of mathematical models which can assess the requirement of electricity, fuel, and labor for four model systems of rice processing complex. 2) Development of a computer simulation model which produce the improved designs of RPC by the evaluation results of energy requirements of four RPC models. The results from this study are summarized as follows : 1) Mathematical models were developed on the basis of result of mass balance analysis and required power of machines for each process. 2) A computer simulation model was developed, which can produce the improved designs of RPC by the evaluation results of energy requirements. The computer simulation model language was BORLAND $C^{++}$. 3) The results of simulation showed that total energy requirements were ranged from 75.94㎾h/t to 124.30㎾h/t. 4) From the results of computer analysis of energy requirement classified by drying type, it was found that energy requirement of the drying type A{paddy rice (PR) for storage-natural air drying(15%), PR for milling-heated air drying(16%)} were less than that of the drying type B{1 step-natural air drying(PR for storage : 18%, PR for milling : 20%), 2 step-heated air drying(PR for storage : 15%, PR for milling : 16%)}. 5) The energy efficient drying method is that all the incoming rough rice to RPC should be dried by national air drying systems. If it is more than the capacity of national air drying system, the amount of surplus rough rice is recommended to be dried by the heated air drying method.

  • PDF

ENERGY AND PROTEIN REQUIREMENTS OF KHAKI CAMPBELL × THAI NATIVE LAYING DUCKS

  • Thongwittaya, N.;Tasaki, I.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.5 no.2
    • /
    • pp.365-368
    • /
    • 1992
  • The experiment was carried out to estimate the energy and protein requirements of Khaki Campbell $\times$ Thai Native laying ducks. To estimate the energy requirement, 5 experimental diets were formulated at levels of 2.70, 2.75, 2.80, 2.85 and 2.90 Mcal ME/kg. These diets were equal in ME/CP ratio (170/l). A total of 150 18-week old laying ducks were assigned to 5 energy level treatments, each comprising 3 replicates of 10 birds each, and they were fed the diets for 18 weeks. To estimate the protein requirement, 90 18-week old laying ducks were divided into 9 groups of 10 birds each, and they were assigned to 3 protein level treatments, each comprising 3 replicates. The levels of protein in the diets were 13.5%, 15.0% and 16.5%, and all diets were isocaloric (2.8 Mcal ME/kg). As a result, the 16.5% protein diet gave significantly better egg production than the 13.5% and 15.0% protein diets, however, no significant difference in egg production was found among the energy levels. Feed cost to produce 1k eggs was lower in the 2.70 Mcal and 16.5%protein diets than in the higher ME and lower protein diets.

Decomposition of Direct and Indirect Energy Consumption Growth in Korea from 1990 to 2000 (한국 가정부문 직간접 에너지소비의 증가요인 분석: 1990~2000)

  • Park, Hi-Chun
    • Environmental and Resource Economics Review
    • /
    • v.15 no.3
    • /
    • pp.531-553
    • /
    • 2006
  • As energy conservation can be realized through changes in the composition of goods and services consumed, there is a need to assess indirect and total household energy requirements. The Korean household sector was responsible for about 55% of the country's primary energy requirement in the period from 1990 to 2000. And more than 60% of household energy requirement was indirect. Thus, indirect and total rather than direct household energy requirements should be the target of energy conservation policies. Increases in household consumption expenditure were responsible for a relatively high growth of energy consumption. Switching to consumption of less energy intensive products and decrease in energy intensities of products contributed substantially to reduce the increase in total household energy requirement.

  • PDF

Operating Method of BESS for Providing AGC Frequency Control Service Considering Its Availability Maximization (배터리 가용성 극대화를 고려한 BESS의 AGC 주파수제어 추종운영방안)

  • Choi, Woo Yeong;Yu, Ga Ram;Kook, Kyung Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1161-1168
    • /
    • 2016
  • Battery energy storage system(BESS) attract the attention of the power system operators with its fast response to a disturbance in spite of its limited energy capacity. This paper proposes the operating method of BESS for following the Automatic Generation Control(AGC) frequency control which is centrally distributed by a system operator. As BESS needs to just meet the control requirement from the system operator, it should be able to properly manage the state of charge(SOC) of BESS to be available to control signal. For doing these, the proposed method distributes the control requirement to available batteries in proportion to its SOC. In addition, unavailable batteries are controlled to recover the SOC to an appropriate range, and the recovering power is supplied by available batteries meeting the control requirement. Moreover, the proposed method manages the efficiency of power conversion system (PCS) by limiting the number of PCS to be assigned for the low control requirement. Finally, the case studies are carried out to verify the effectiveness of proposed strategy.

Determination of Energy and Time Requirement for Cooking Pigeon Pea (Cajanus cajan)

  • Akinoso, Rahman;Oladeji, Ojeronke Dewum
    • Journal of Biosystems Engineering
    • /
    • v.42 no.1
    • /
    • pp.56-61
    • /
    • 2017
  • Purpose: High energy requirement and long cooking time are limiting consumption of pigeon pea (Cajanus cajan), a nutritious food. This study was performed to estimate energy and time demand by different methods of cooking pigeon pea. Methods: Pigeon pea (150 g) was soaked in 2.0 L of water at ambient temperature ($29{\pm} 2^{\circ}C$) to determine hydration behavior. Cooking experiments were conducted using aluminum and pressure-cooking pots. Efficiency of cooking was evaluated using four types of cooking appliances (kerosene, liquefied petroleum gas (LPG), electric, and charcoal stoves). Normal (continuous heating until the food was satisfactorily cooked) and control (controlling the energy input to closely match the actual energy required) cooking were conducted. Energy requirement and duration of cooking were determined using standard procedures. Results: Soaking increased moisture content from 11.99 to 30.01% in 90 min, while water absorption rate decreased with soaking duration. In cooking 150 g of pigeon pea using kerosene stove, presoaked normal pressure-pot cooking method consumed the least energy (10 800 kJ) and time (205 min), while unsoaked normal cooking consumed the highest energy (18 450 kJ) and time (336 min). Using LPG stove, unsoaked normal cooking method required the highest energy (52 470 kJ), while presoaked control pressure-pot required the least energy (14 405 kJ). For electric stove, the lowest energy (15 560 kJ) and shortest duration (105 min) were recorded during control cooking of presoaked sample in the pressure-pot. Conclusions: Control cooking was not practicable using charcoal stove. Generally, kerosene stove consumed the least energy, while electric stove was found to have the shortest duration of cooking.

Enteric methane emissions, energy partitioning, and energetic efficiency of zebu beef cattle fed total mixed ration silage

  • Subepang, Sayan;Suzuki, Tomoyuki;Phonbumrung, Thamrongsak;Sommart, Kritapon
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.4
    • /
    • pp.548-555
    • /
    • 2019
  • Objective: The main objective of this study was to evaluate the effect of different feeding levels of a total mixed ration silage-based diet on feed intake, total tract digestion, enteric methane emissions, and energy partitioning in two beef cattle genotypes. Methods: Six mature bulls (three Thai natives, and three Thai natives - Charolais crossbreeds) were assigned in a replicated $3{\times}3$ Latin square design, with cattle breed genotype in separate squares, three periods of 21 days, and three energy feeding above maintenance levels (1.1, 1.5, and 2.0 MEm, where MEm is metabolizable energy requirement for maintenance). Bulls were placed in a metabolic cage equipped with a ventilated head box respiration system to evaluate digestibility, record respiration gases, and determine energy balance. Results: Increasing the feeding level had no significant effect on digestibility but drastically reduced the enteric methane emission rate (p<0.05). Increasing the feeding level also significantly increased the energy retention and utilization efficiency (p<0.01). The Thai native cattle had greater enteric methane emission rate, digestibility, and energy utilization efficiency than the Charolais crossbred cattle (p<0.05). The daily metabolizable energy requirement for maintenance in Thai native cattle ($388kJ/kg\;BW^{0.75}$, where $BW^{0.75}$ is metabolic body weight) was 15% less than that in Charolais crossbred cattle ($444kJ/kg\;BW^{0.75}$). Conclusion: Our results suggested that the greater feeding level in zebu beef cattle fed above maintenance levels resulted in improved energy retention and utilization efficiency because of the reduction in enteric methane energy loss. The results also indicated higher efficiency of metabolisable energy utilization for growth and a lower energy requirement for maintenance in Bos indicus than in Bos taurus.

Estimating free-living human energy expenditure: Practical aspects of the doubly labeled water method and its applications

  • Park, Jonghoon;Kazuko, Ishikawa-Takata;Kim, Eunkyung;Kim, Jeonghyun;Yoon, Jinsook
    • Nutrition Research and Practice
    • /
    • v.8 no.3
    • /
    • pp.241-248
    • /
    • 2014
  • The accuracy and noninvasive nature of the doubly labeled water (DLW) method makes it ideal for the study of human energy metabolism in free-living conditions. However, the DLW method is not always practical in many developing and Asian countries because of the high costs of isotopes and equipment for isotope analysis as well as the expertise required for analysis. This review provides information about the theoretical background and practical aspects of the DLW method, including optimal dose, basic protocols of two-and multiple-point approaches, experimental procedures, and isotopic analysis. We also introduce applications of DLW data, such as determining the equations of estimated energy requirement and validation studies of energy intake.