• Title/Summary/Keyword: Energy plant

Search Result 3,892, Processing Time 0.029 seconds

Radiobiological Evaluation in Korean Native Goat Bred in the Nuclear Power Plant (원자력발전소 사육 재래산양의 방사선 생물학적 평가)

  • Kim, Se-Ra;Kim, Tae-Hwan;Lee, Hae-Jun;Oh, Heon;Cho, Sung-Ki;Oh, Ki-Seok;Park, In-Chul;Son, Chang-Ho;Kim, Sung-Ho
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.317-322
    • /
    • 2003
  • Cytogenetic and hematological analysis was performed in peripheral blood from the Korean native goat bred in the nuclear power plant (Wolsong and Uljin) and control area. The frequency of micronuclei (MN) in peripheral blood lymphocytes from goat was used as a biomarker of radiobiological effects resulting from exposure to environmental radiation. An estimated dose of radiation was calculated by best fitting linear-quadratic model based on the radiation-induced MN data over the range from 0 to 4 Gy from the goat lymphocytes with in vitro irradiation. MN rates in goats from the Wolsong and Uljin nuclear power plant, and control area were 9.60/1000, 6.83/1000 and 9.88/1000, respectively. There were no significant differences in MN frequencies and hematological values in goats between nuclear power plant and control area. High level of platelet in the goat from Uljin nuclear power plant was observed, which seemed to be related to the goat management.

Spatial Variation Characteristics of Seismic Motions through Analysis of Earthquake Records at Fukushima Nuclear Power Plant (후쿠시마 원자력발전소 지진 계측 기록 분석을 통한 지진파의 공간적 변화 특성 평가)

  • Ha, Jeong-Gon;Kim, Mi Rae;Kim, Min Kyu
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.5
    • /
    • pp.223-232
    • /
    • 2021
  • The spatial variation characteristics of seismic motions at the nuclear power plant's site and structures were analyzed using earthquake records obtained at the Fukushima nuclear power plant during the Great East Japan Earthquake. The ground responses amplified as they approached the soil surface from the lower rock surface, and the amplification occurred intensively at about 50 m near the ground. Due to the soil layer's nonlinear characteristics caused by the strong seismic motion, the ground's natural frequency derived from the response spectrum ratio appeared to be smaller than that calculated from the shear wave velocity profile. The spatial variation of the peak ground acceleration at the ground surface of the power plant site showed a significant difference of about 0.6 g at the maximum. As a result of comparing the response spectrums at the basement of the structure with the design response spectrum, there was a large variability by each power plant unit. The difference was more significant in the Fukushima Daiichi site record, which showed larger peak ground acceleration at the surface. The earthquake motions input to the basement of the structure amplified according to the structure's height. The natural frequency obtained from the recorded results was lower than that indicated in the previous research. Also, the floor response spectrum change according to the location at the same height was investigated. The vertical response on the foundation surface showed a significant difference in spectral acceleration depending on the location. The amplified response in the structure showed a different variability depending on the type of structure and the target frequency.

Impact of Thermal-Treated Coffee Grounds on the Growth of Phaseolus Vulgaris (열처리된 커피박이 강낭콩 성장에 미치는 영향)

  • Ji-Hye Oh;Dong Hyeon Lee;Dong-Jun Kwon;Gwang Hyun Roh;Man Tae Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.5
    • /
    • pp.1051-1059
    • /
    • 2024
  • This study aims to identify the effects of coffee grounds on plant growth in order to propose new ways to recycle this waste product. As a way to recycle coffee grounds, the effect of placing coffee grounds on the surface of kidney bean plants on plant growth was investigated by determining the root, stem, leaf front growth, and seed germination rates. To maximize the effectiveness of coffee grounds, the effect of heat treated temperature for coffee grounds on plant growth was investigated. Normal kidney bean growth was checked for seed germination and seedling growth. The germination rate was 80 % for the non-treated case without coffee grounds, but 100% for the coffee grounds treated at 100 ℃ and 250 ℃ of heat treatment. Stem, root, and leaf growth were all improved with the use of coffee grounds compared to the non-treated case. This can be attributed to the organic matter present in the coffee grounds and the fact that coffee grounds are hydrophilic, which makes them more hydrating for plants. The coffee grounds were utilized to enhance plant growth, which could be utilized as a new way to recycle coffee grounds.

Analysis of Energy Performance and PMV Improvement by Application of Passive Factor for Office Building Renewal (오피스건물 리뉴얼시 패시브 요소적용에 따른 에너지성능 및 PMV 개선에 관한 연구)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.55-64
    • /
    • 2014
  • This paper presents a case study to investigate the monthly calculation method of ISO 13790 applied for a office building. The energy performance analysis according to improvement of insulation and air permeability of windows in K office buildings is investigated by means of building energy efficiency rating tool ($ECO_2-OD$). The K building energy system is tested experimently by the measurement of PMV(predicted mean vote) for the control of indoor thermal environment and heat transmission coefficient of windows and interior walls respectively, before and after the example K office building is remodeled passively. Therefore, Internet based energy assessment program of energy efficiency rating of office building can be applied as a program for the annual energy requirement and for evaluation of energy savings from the experimental and simulation results.

Study on the policy literacy of the Republic of Korea regarding nuclear and new-renewable energy

  • Im, Eunok;Kim, Ju Kyong;Woo, Seung Min
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.741-748
    • /
    • 2022
  • Policy literacy plays a critical role in enhancing deliberative communication among the public, policymakers, and experts. It also helps develop a positive view of policy by the public, which facilitates public acceptance. Despite its importance, however, policy literacy has received little attention in energy policy practice. Therefore, this study explores factors affecting the public's understanding and knowledge (i.e., policy literacy) of nuclear and new-renewable energy policies. Accordingly, we analyzed data from an online survey of 790 laypeople in Korea. Specifically, we examined the effects of trust, transparency, and policy public relations (PR) on the policy literacy of the public regarding the two alternative energy sources. The analysis revealed that people showed higher policy literacy about the alternative sources when provided with more transparent information and exposed to more policy PR activities. However, we found that trust in energy plant operators played a negligible role in improving policy literacy for both energy sources. Based on these findings, we developed some policy suggestions to secure the energy policy literacy of the public.

Impacts of Energy Tax Reform on Electricity Prices and Tax Revenues by Power System Simulation (전력계통 모의를 통한 에너지세제 개편의 전력가격 및 조세수입에 대한 영향 연구)

  • Kim, Yoon Kyung;Park, Kwang Soo;Cho, Sungjin
    • Environmental and Resource Economics Review
    • /
    • v.24 no.3
    • /
    • pp.573-605
    • /
    • 2015
  • This study proposed scenarios of tax reform regarding taxation on bituminous coal for power generation since July 2015 and July 2014, estimated its impact on SMP, settlement price, tax revenue from year 2015 to year 2029. These scenarios are compared with those of the standard scenario. To estimate them, the power system simulation was performed based on the government plan, such as demand supply program and the customized model to fit Korea's power system and operation. Imposing a tax on bituminous coal for power generation while maintaining tax neutrality reducing tax rate on LNG, the short-term SMP is lowered than the one of the standard scenario. Because the cost of nuclear power generation is still smaller than costs of other power generation, and the nuclear power generation rarely determines SMPs, the taxation impact on SMP is almost nonexistent. Thus it is difficult to slow down the electrification of energy consumption due to taxation of power plant bituminous coal in the short term, if SMP and settlement price is closely related. However, in the mid or long term, if the capacity of coal power plant is to be big enough, the taxation of power plant bituminous coal will increase SMP. Therefore, if the tax reform is made to impose on power plant bituminous coal in the short term, and if the tax rate on LNG is to be revised after implementing big enough new power plants using bituminous coal, the energy demand would be reduced by increasing electric charges through energy tax reform. Both imposing a tax on power plant bituminous coal and reducing tax rate on LNG increase settlement price, higher than the one of the standard scenario. In the mid or long term, the utilization of LNG complex power plants would be lower due to an expansion of generating plants, and thus, the tax rate on LNG would not affect on settlement price. Unlike to the impact on SMP, the taxation on nuclear power plants has increased settlement price due to the impact of settlement adjustment factor. The net impact of energy taxation will depend upon the level of offset between settlement price decrease by the expansion of energy supply and settlement price increase by imposing a tax on energy. Among taxable items, the tax on nuclear power plants will increase the most of additional tax revenue. Considering tax revenues in accordance with energy tax scenarios, the higher the tax rate on bituminous coal and nuclear power, the bigger the tax revenues.

Economic analysis of Frequency Regulation Battery Energy Storage System for Czech combined heat & power plant (체코 열병합발전소 주파수조정용 배터리에너지저장장치 경제성 분석)

  • KIM, YuTack;Cha, DongMin;Jung, SooAn;Son, SangHak
    • Journal of Energy Engineering
    • /
    • v.29 no.2
    • /
    • pp.68-78
    • /
    • 2020
  • According to the new climate change agreement, technology development to reduce greenhouse gases is actively conducted worldwide, and research on energy efficiency improvement in the field of power generation and transmission and distribution is underway [1,2]. Economic analysis of the operation method of storing and supplying surplus electricity using energy storage devices, and using energy storage devices as a frequency adjustment reserve power in regional cogeneration plants has been reported as the most profitable operation method [3-7]. Therefore, this study conducted an economic analysis for the installation of energy storage devices in the combined heat and power plant in the Czech Republic. The most important factor in evaluating the economics of battery energy storage devices is the lifespan, and the warranty life is generally 10 to 15 years, based on charging and discharging once a day. For the simulation, the ratio of battery and PCS was designed as 1: 1 and 1: 2. In general, the primary frequency control is designed as 1: 4, but considering the characteristics of the cogeneration plant, it is set at a ratio of up to 1: 2, and the capacity is simulated at 1MW to 10MW and 2MWh to 20MWh according to each ratio. Therefore, life was evaluated based on the number of cycles per year. In the case of installing a battery energy storage system in a combined heat and power plant in the Czech Republic, the payback period of 3MW / 3MWh is more favorable than 5MW / 5MWh, considering the local infrastructure and power market. It is estimated to be about 3 years or 5 years from the simple payback period considering the estimated purchase price without subsidies. If you lower the purchase price by 50%, the purchase cost is an important part of the cost for the entire lifetime, so the payback period is about half as short. It can be, but it is impossible to secure profitability through the economy at the scale of 3MWh and 5MWh. If the price of the electricity market falls by 50%, the payback period will be three years longer in P1 mode and two years longer in P2 and P3 modes.