• Title/Summary/Keyword: Energy plant

Search Result 3,893, Processing Time 0.033 seconds

Miniature planar stack using the flexible Printed Circuit Board as current collectors (연성 기판을 전류 집전체로 사용한 평판형 연료전지 스택)

  • Kim, Sung-Han;Cha, Hye-Yeon;Miesse, Craig M.;Cha, Suk-Won;Jang, Jae-Hyuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.1-4
    • /
    • 2008
  • Fuel cells have the potential of providing several times higher energy storage densities than those possible using current state-of-the-art lithium-ion batteries, but current energy density of fuel cell system is not better than that of lithium-ion batteries. To achieve the high energy density, volume and weight of fuel cell system need to be reduced by miniaturizing system components such as stack, fuel tank, and balance-of-plant. In this paper, the thin flexible PCB (Printed circuit board) is used as a current collector to reduce the stack volume. Two end plates are made from light weight aluminum alloy plate. The plate surface is wholly oxidized through the anodizing treatment for electrical insulation. The opening rate of cathode plate hole is optimized through unit cell performance measurement of various opening rates. The performances are measured at room temperature and ambient pressure condition without any repulsive air supply. The active area of MEA is 10.08 $cm^2$ and active area per a unit cell is 1.68 $cm^2$. The peak power density is about 210 mW/$cm^2$ and the air-breathing planar stack of 2 Wis achieved as a small volume of 18 cc.

  • PDF

Application of the Microbial Process for Hydrogen Sulfide Removal and Bio-Sulfur Production from Landfill Gas (미생물 공법에 의한 매립가스 황화수소 제거 및 바이오황 생산)

  • Khim, Young-Min;Song, Hyo-Soon;Ahn, Hyoseong;Chun, Seung-Kyu
    • New & Renewable Energy
    • /
    • v.16 no.1
    • /
    • pp.68-76
    • /
    • 2020
  • Operational testing of the THIOPAQ® facility that removes H2S from landfill gas was performed for 746 days. The average H2S removal efficiency was 99.4%, and the input quantities of air, NaOH, and nutrients per sulfur load were 13.1 ㎥/ton, 1.5 ㎥/ton, and 28.7 L/ton, respectively. The purity of the bio-sulfur produced from the facility was 94.8%, with 3.3% impurities, except for moisture. X-ray photoelectron spectroscopy showed that the compositional contents of amino acids and free amino acids of the bio-sulfur surface were 5,308 and 728 mg/kg, respectively. The mean particle size was 3.41 ㎛, which was much smaller than that of chemical sulfur. Based on these results, a high H2S removal rate of more than 97% is feasible, and high value-added bio-sulfur, which is used as a fungicide because of its hydrophilic characteristics and small size, can be obtained at this facility.

The analysis on PVB film optical characteristics for PV module generating in high-temperature (고온용 PV module을 위한 PVB film 광특성 연구)

  • Lee, Sang-Hun;Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1320-1321
    • /
    • 2011
  • According to the advance that solar power plants go into the desert, power plants are getting greater capacity. The desert is unspoiled resources and it is well suited to build a solar power plant, because of abundant solar radiation and long sunshine duration. but existing PV modules have several weaknesses and don't generate lower the rated power, because it wasn't designed to produce in extreme environments like a desert climate. The one of the weaknesses of PV modules is that the characteristics of the temperature of the Encapsulants(EVA sheet) are not good in a desert climate, because the EVA sheet is melt at high temperature. In this study, a decrease phenomenon of the transmittance depending on the melting point of the Encapsulant(PV module using EVA sheet : $75^{\circ}C$ PV module using PVB film : $110^{\circ}C$) is suggested, it would be the one of the important factors to achieve rated output of the PV modules in high temperature climate regions.

  • PDF

Analysis of Hydraulic-Pneumatic System for Offshore Plant Heave Compensator (해양플랜트용 수직 보상기의 유공압 시스템 해석)

  • Jung, Yong-Gil;Hwang, Sung-Gu;Kim, Gwi-Nam;Yoon, Yung-Hwan;Hyun, Jang-Hwan;Huh, Sun-Chul
    • Journal of Power System Engineering
    • /
    • v.19 no.1
    • /
    • pp.76-82
    • /
    • 2015
  • An analysis model is developed using a commercial software 'simulationX' for designing hydraulic-pneumatic system of heave compensator for offshore drilling operations. Reliability verification of the analysis model for the test equipment of 1/5 scale compensator was conducted by comparing test results and simulation results. An analysis of full scale heave compensator is developed on the basis of verified a model. Then, the results of simulation were analyzed to obtain following conclusion. The displacement of crown block about excitation input amplitude (${\pm}3,000mm$) of the steward platform using a 'simulationX' is attenuated under ${\pm}35mm$, and the compensation rate is 98.7%. In this study, goal of a compensation rate is more than 95%. The previously results are satisfied with the objectives of compensation rate.

A study on new & renewable energy capacity factor in Feed-In Tariff fund (신재생에너지 이용률이 발전차액에 미치는 영향에 관한 연구)

  • Jeon, Byung-kyu;Moon, Joon-sang;Oh, Seok-hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.200-203
    • /
    • 2009
  • 현재 발전차액 지원을 받고 있는 신재생에너지 전원은 태양광, 풍력, 수력, 매립가스, 바이오 가스, 연료전지 등 6개 전원이 있다. 신재생에너지 중에서 태양광, 조력, 연료전지, 풍력의 기준가격은 고정가격이며, 폐기물은 변동가격이고, 수력, 매립가스, 바이오가스, 바이오매스는 고정가격과 변동가격 중에서 선택할 수 있도록 되어 있다. 지난 2년간 신재생에너지 발전소 실적 이용률을 기준가격 적용 이용률과 비교해 보면 매립가스(20MW 미만), 바이오가스, 연료전지 이용률은 기준가격 적용 이용률 보다 낮게 나타났으며, 특히 바이오가스는 실적 이용률이 매우낮게 나타났다. 기타 신재생에너지 전원은 실적 이용률이 높게 나타났다. 발전차액(기반기금)은 기준가격에서 계통한계가격을 뺀 금액을 의미하며 고정가격, 변동가격의 요금선택에 따라 발전차액에 미치는 요소들이 달라진다. 고정가격을 선택한 경우는 계통한계가격, 이용률(전력 거래량)이 영향을 미치며 변동가격을 선택한 경우는 이용률만이 발전차액에 영향을 미친다.

  • PDF

Feasibility Evaluation & Strategy of Replacement of Power Generation Fuel by Using Bio-diesel (바이오 디젤의 발전용 연료화 타당성 평가)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Gyu;Lee, Jung-Bin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.806-812
    • /
    • 2009
  • Availability of reliable and affordable energy supply is a prerequisite for economic growth. Renewables are the third largest contributor to global electricity production after coal and natural gas and account for a share of 18%. Power generating capacity from renewables has increased to around 900GW by the year 2007. Today biodiesel fuels have been in commercial use in many countries and recently the world-wide biodiesel market has experienced considerable growth, which is partly due to various tax concession programs and other financial incentives. In Korea, biodiesel has already been used for transportation fuel, but not used for power generation fuel yet. Korean government has a strategy for renewable energy propagation, especially the goal of power generation amount by renewable energy is 3% of total power production by 2012. This paper focuses on the feasibility study for adaptability and strategy of using biodiesel as power generation fuel. The study also has the plan to replace the fuel of thermal power plant, gas turbine and distributed power system. As the increase of biodiesel fuel, I look forward to environment-friendly power generation and the strategy of Renewable Portfolio Standards(RPS).

  • PDF

Development of gas-to-solid system for energy recovery from a landfill gas using hydrate method (중소규모 매립장의 매립가스 에너지화를 위한 GTS Pilot plant 개발)

  • Moon, Donghyun;Shin, Hyungjoon;Han, Kyuwon;Lee, Jaejeong;Lee, Gangwoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.185.1-185.1
    • /
    • 2011
  • 본 연구는 중 소규모 매립지가스(LFG)의 활용을 위한 가스고체화(Gas-To-Solid) 기술개발을 목적으로 하고 있다. LFG는 환경적인 문제로 인하여 소각 등의 방법으로 처리하고 있으나, 약 5,000kcal/$m^3$의 높은 발열량과 일반적으로 매립 후 20~30년 후까지 지속적인 발생특성으로 안정적인 공급이 가능한 신재생에너지원으로 활용될 수 있다. LFG 자원화 할 경우 발전 및 중질가스 등으로 활용하는 것이나, 중소규모 매립장의 경우 경제성 등의 문제로 자원화하지 못하고 태워지거나 방치되고 있다. 본 연구에서는 LFG의 저장과 수송 기술 중 GTS 기술을 통하여 저장과 수송에 제약이 크고 많은 비용이 소비되는 기체 상태의 에너지원을 하이드레이트화 시킴으로서 중 소규모 매립지에서 상대적으로 적은 비용으로 가스저장과 지상수송이 가능하게 할 수 있다. 본 연구의 결과로 LFG 에너지화 실증화 플랜트를 설계/제작 하였으며, 메탄+이산화탄소+물 하이드레이트 형성 실험을 통해 4.56 Mpa, 277.2 K 조건에서 3시간을 한 사이클로하는 공정운전을 가지는 것을 확인하였다.

  • PDF

Developement for Pretreatment System of Distributed Power Generation by using Livestock BIO-ENERGY (축산폐기물 바이오 에너지 분산발전용 전처리시스템 개발)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Lee, Jung-Bin;Rhim, Sang-Gyu;Kim, Jae-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.585-588
    • /
    • 2007
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection constrains. KEPCO (Korea Electric Power Corporation) is performing the project to develope the Distributed Micro Gas Turbine (MGT) technolgies by using Swine BIO-ENERGY. This paper describes the plans and strategies for the renewable energy of MGT on actual grid-connection under Korean situations. KEPCO also, has a research plan on bio-gas pretreatment system applicable to our domestic swine renewable resources and is performing concept design of pilot plant to test grid operation. In addition, this testing will be conducted in order to respond to a wide variety of needs for application and economic evaluation in the field of On-site generation.

  • PDF

Economic Analysis of High-Efficiency Production Facilities using Capital Recovery Factor (자본회수계수를 고려한 고효율 생산설비의 경제성분석)

  • Park, Hyung-Joon;Chung, Chcn-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.117-123
    • /
    • 2007
  • This paper is about the economic analysis of the replacement of electric facilities in the production facilities. As the interest of energy is increasing, the efficiency of facilities become more important. So, in this paper, we diagnosed facilities, especially electric motors, in the plant and calculated the operating efficiency, power loss with the load factor. And when we replace these facilities into high-efficiency motors, we also calculated new energy efficiency, energy loss and economic analysis through capital recovery factor. As a result, we economically proved that using high-efficiency motor is more beneficial than using non-high-efficiency motors in the model process.

Thermal sensation based humidity controls for improving indoor thermal comfort and energy efficiency in summer (온열감각 기반 습도제어를 통한 여름철 건물의 열쾌적 및 에너지성능 향상)

  • Moon, Jin Woo;Chin, Kyung-Il;Kim, Sang-Chul;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.75-81
    • /
    • 2014
  • This study aims at investigating the benefit of actively controlling humidity to improve thermal comfort and energy efficiency in climate zones other than hot-dry. For this research purpose, three thermal control strategies, which adopted different initiative degrees in humidity control, were developed - i) temperature controls, ii) temperature and humidity controls, and iii) thermal sensation controls. Performance of the developed strategies were experimentally tested in a full scale mock up of an office environment. The study revealed that air temperature was better controlled in the occupied zone under the first two strategies than the thermal sensation based strategy. On the other hand, the thermal sensation-based strategy maintained thermal sensation levels more comfortably. In addition, energy consumption was significantly reduced when humidity was actively controlled for thermal comfort. The thermal sensation-based control strategy consumed significantly less electricity than the first two strategies. From these findings, this study indicated that adoption of an active humidity control system based on thermal sensation can provide increased thermal comfort as well as energy savings for summer seasons in climatic zones other than hot-dry.