• Title/Summary/Keyword: Energy plant

Search Result 3,892, Processing Time 0.032 seconds

TFWT and OBT Concentrations in Soybean Plants Exposed to HTO Vapor at Different Growth Stages (콩의 생육단계별 HTO 증기 피폭에 따른 작물체내 TFWT 및 OBT 농도)

  • Lim, K.M.;Choi, Y.H.;Lee, W.Y.;Park, H.G.;Kang, H.S.;Choi, H.J.;Lee, H.S.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.213-219
    • /
    • 2004
  • Soybean plants were exposed to HTO vapor in an exposure box for 1 hour at different growth stages. Relative concentrations of TFWT at the end of exposure (percent ratios of TFWT concentrations to mean HTO concentrations in air moisture in the box during exposure) decreased on the whole in the order of leaf > shell > seed > stem with the highest values of 40.2% and 6.4% for leaf and stem, respectively. TFWT concentrations reduced by factors of several thousands to several hundred-thousands from the end of exposure till the harvest. The reduction factor decreased in the order of leaf > shell > seed > stem. Relative OBT concentrations at harvest (ratios of the OBT concentration in the dry plant part at harvest to the initial leaf TFWT concentration, ml $g^{-1}$) were in the range of $2.2{\times}10^{-5}{\sim}9.5{\times}10^{-3}$ for seeds being the highest when the exposure was performed at the actively seed-developing stage. The exposure time-dependent variation in the OBT concentration was much greater in seeds and shells than in leaves and stems. It was indicated that OBT would contribute to almost all the radiation dose due to the consumption of soybean seeds in most cases after an acute exposure of growing plants to HTO vapor. Present results are applicable to establishing and validating soybean $^3H$ models for an acute accidental release of HTO.

Study of Soil Erosion for Evaluation of Long-term Behavior of Radionuclides Deposited on Land (육상 침적 방사성 핵종의 장기 거동 평가를 위한 토사 침식 연구)

  • Min, Byung-Il;Yang, Byung-Mo;Kim, Jiyoon;Park, Kihyun;Kim, Sora;Lee, Jung Lyul;Suh, Kyung-Suk
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.1
    • /
    • pp.1-13
    • /
    • 2019
  • The accident at the Fukushima Dai-ichi Nuclear Power Plant (FDNPP) resulted in the deposition of large quantities of radionuclides over parts of eastern Japan. Radioactive contaminants have been observed over a large area including forests, cities, rivers and lakes. Due to the strong adsorption of radioactive cesium by soil particles, radioactive cesium migrates with the eroded soil, follows the surface flow paths, and is delivered downstream of population-rich regions and eventually to coastal areas. In this study, we developed a model to simulate the transport of contaminated sediment in a watershed hydrological system and this model was compared with observation data from eroded soil observation instruments located at the Korea Atomic Energy Research Institute. Two methods were applied to analyze the soil particle size distribution of the collected soil samples, including standardized sieve analysis and image analysis methods. Numerical models were developed to simulate the movement of soil along with actual rainfall considering initial saturation, rainfall infiltration, multilayer and rain splash. In the 2019 study, a numerical model will be used to add rainfall shield effect by trees, evaporation effect and shield effects of surface water. An eroded soil observation instrument has been installed near the Wolsong nuclear power plant since 2018 and observation data are being continuously collected. Based on these observations data, we will develop the numerical model to analyze long-term behavior of radionuclides on land as they move from land to rivers, lakes and coastal areas.

Biogas Production and Utilization Technologies from Organic Waste (유기성폐기물을 이용한 바이오가스 생산 및 활용기술)

  • Heo, Nam-Hyo;Lee, Seung-Heon;Kim, Byeong-Ki
    • New & Renewable Energy
    • /
    • v.4 no.2
    • /
    • pp.21-30
    • /
    • 2008
  • Anaerobic digestion (AD) is the most promising method of treating and recycling of different organic wastes, such as OFMSW, household wastes, animal manure, agro-industrial wastes, industrial organic wastes and sewage sludge. During AD, i.e. degradation in the absence of oxygen, organic material is decomposed by anaerobes forming degestates such as an excellent fertilizer and biogas, a mixture of carbon dioxide and methane. AD has been one of the leading technologies that can make a large contribution to producing renewable energy and to reducing $CO_2$ and other GHG emission, it is becoming a key method for both waste treatment and recovery of a renewable fuel and other valuable co-products. A classification of the basic AD technologies for the production of biogas can be made according to the dry matter of biowaste and digestion temperature, which divide the AD process in wet and dry, mesophilic and thermophilic. The biogas produced from AD plant can be utilized as an alternative energy source, for lighting and cooking in case of small-scale, for CHP and vehicle fuel or fuel in industrials in case of large-scale. This paper provides an overview of the status of biogas production and utilization technologies.

  • PDF

Characteristics and Modeling Analysis of Entrained Flow Gasifiers (분류층 가스화기 특징 및 공정모사 분석)

  • Yoo, Jeongseok;Kim, Youseok;Paek, Minsu
    • New & Renewable Energy
    • /
    • v.9 no.3
    • /
    • pp.20-28
    • /
    • 2013
  • The gasification process has developed to convert coal into the more useful energy and material since decades. Despite the numberous design of ones, entrained flow gasifier of the major companies has had an advantage on the market. Because it has a merit of full-scale and high performance plant. In this paper, the gasification technologies of GE energy, Phillips, Siemens and Shell have been reviewed to compare their characteristics and a high performance gasification process was suggested. And the simulation model of gasifiers using Aspen Plus offered the quantitative comparison data for difference designs. The simulation results revealed the poor performance of the slurry feed than dry design. The corresponding cold gas efficiency of 77% is much lower than the 80.3% for the dry feed cases. The exergy analysis of the difference syngas quenching system showed that chemical quenching is superior to another. The results of analysis recommend the two stage gasifier with dry multi-feeder as the energy effective design.

A Study on Anaerobic Sewage Treatment Using a Fluidized Bed Reactor (유동상 반응조를 이용한 하수의 혐기성 처리에 관한 연구)

  • Ye, Hyoung-Young;Lee, Eun-Young;Bae, Jae-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.265-273
    • /
    • 2012
  • Anaerobic sewage treatment is drawing attentions due to high energy consumptions and sludge production associated with aerobic treatment. This study evaluates the treatment characteristics and energy balance of a fluidized bed reactor (FBR) for treating domestic sewage at $20^{\circ}C{\sim}25^{\circ}C$ for 245 days. Sewage fed to the FBR was a primary clarifier effluent of a domestic sewage treatment plant with COD of 99-301 mg/L and $BOD_{5}$ of 37-149 mg/L. Effluent $SBOD_{5}$ and its removal efficiency at HRT of 1~3 h were 6~15 mg/L and 73.4~85.5%, respectively, achieving high removal efficiency for soluble organic substances even at short HRTs. COD removal efficiency and its effluent concentration were 53.8~75.9% and 51~83 mg/L, respectively. The energy production potential from gaseous methane was 0.009-0.028 kWh/$m^{3}$, which satisfies the energy required for the FBR operation.

Microstructural Characteristics of the Fuel Cladding Tubes Irradiated in Kori Unit 1

Development of Distributed Micro Gas Turbine(MGT) Technology by using Swine BID-ENERGY (축산폐기물 BIO-ENERGY를 이용한 분산형 마이크로 가스터빈 발전기술 개발)

  • Hur Kwang-beom;Park Jung-Keuk;Lee Jung-bin;Rhim Sang-gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.463-466
    • /
    • 2005
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection constrains. KEPOD (Korea Electric Power Corporation) is performing the project to develope the Distributed Micro Gas Turbine (MGT) technologies by using Swine BID-ENERGY. This paper describes the plans and strategies for the renewable energy of MGT on actual grid-connection under Korean situations. KEPOD also, has a research plan on bio-gas pretreatment system applicable to our domestic swine renewable resources and is performing concept design of pilot plant to test grid operation. In addition, this testing will be conducted in order to respond to a wide variety of needs for application and economic evaluation in the field of On-site generation.

  • PDF

Development of Power Conditioning System for Photovoltaic Power Generation Systems (태양광발전용 3kW급 PCS개발)

  • Min, Byoung-Gwon;Ryu, Seung-Pyo;Jeon, Se-Bong;Lee, Bong-Woo;Kim, Nam-Hae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.123-126
    • /
    • 2005
  • Recently, because of the depletion of fossil fuels and the environmental pollution by using fossil fuels and harmfulness of atomic power plants. the interests concerning new and renewable energy resources are rising increasingly. And of all new and renewable energy sources the PV generation systems are recognized as the most useful and desirable renewable energy source in allowance for installation conditions. In this development, the 3kWp photovoltaic power generation system is realized to verify the performance of the 3kWp PCS developed by Hyundai Heavy Industries Co. (HHI). The photovoltaic array used in this system is composed of 60 modules of 50Wp capacity. The developed system is tested as procedures and items of test regulation recognized by governmen and the experimental results show the excellent electrical characteristics. Now, the 3kWp PCS developed is installed in the PV model house built in HHI plant and is being tested for practical use commercialization.

  • PDF

Study on the Dynamic Synchronizing Control of An Islanded Microgrid (독립운전 마이크로그리드의 능동형 동기 투입 제어에 관한 연구)

  • Cho, Chang-Hee;Jeon, Jin-Hong;Kim, Jong-Yul;Kwon, Soon-Man;Kim, Sung-Shin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1112-1121
    • /
    • 2011
  • A microgrid is an aggregation of multiple distributed generators (DGs) such as renewable energy sources, conventional generators, and energy storage systems that provide both electric power and thermal energy. Generally, a microgrid operates in parallel with the main grid. However, there are cases in which a microgrid operates in islanded mode, or in a disconnected state. Islanded microgrid can change its operational mode to grid-connected operation by reconnection to the grid, which is referred to as synchronization. Generally, a single machine simply synchronizes with the grid using a synchronizer. However, the synchronization of microgrid that operate with multiple DGs and loads cannot be controlled by a traditional synchronizer, but needs to control multiple generators and energy storage systems in a coordinated way. This is not a simple job, considering that a microgrid consists of various power electronics-based DGs as well as alternator-based generators that produce power together. This paper introduces the results of research examining an active synchronizing control system that consists of the network-based coordinated control of multiple DGs. Consequently, it provides the microgrid with a deterministic and reliable reconnection to the grid. The proposed method is verified by using the test cases with the experimental setup of a microgrid pilot plant.

Sensor Communication Network Architecture for Harsh Environments of Nuclear Power Plant (원전 극한환경적용 센서 통신망 구조)

  • Cho, Jai-Wan;Lee, Joon-Koo;Hur, Seop;Koo, In-Soo;Hong, Seok-Boong
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.540-541
    • /
    • 2008
  • 원자력 발전소 격납구조(containment) 내에 설치되는 센서, 구동기(actuator) 및 설비는 원전의 안전운전과 함께 방사능 누출사고와 같은 중대사고(severe accident)를 예방하기 위한 것이다. 격납구조 내부는 Category I 등급으로 분류되며, 격납구조 내부에 설치되는 센서, 구동기, 기기 및 통신망은 IEEE Std. 323-1974에서 정의하는 극한환경(harsh environment) 요건에서 생존할 수 있는 내환경성이 요구된다. 이러한 엄격한 내환경성 요건으로 인해 일반 산업의 IT 기반 센서통신망이 원전 격납건물 내부에는 적용되지 않고 있다. 최근에 이르러 독일을 중심으로 신규로 건설 중이거나 계획 중인 원전에서는 일반 산업의 IT 기반 센서 통신망 적용이 검토되고 있다. 본 논문에서는 IT 기반의 첨단 센서 통신망 기술을 격납구조내부와 같은 극한 환경에 적용하기 위한 방안을 제시하고자 한다. 정상운전중의 원전 격납 건물 내부의 환경(온도, 감마선, 습도) 특성과 중대 사고를 가정한 DBA (설계 기준사고) 요건에서의 환경 특성을 조사하였다. 또한 설계기준사고에서 정의한 감마선 조사 환경에서 통신 시스템의 생존성을 실험하였다. 이를 토대로 격납구조내부의 원전 극한 환경 통신망의 개선방안을 제시하고자 한다.

  • PDF