• Title/Summary/Keyword: Energy plant

Search Result 3,892, Processing Time 0.031 seconds

Process and instrument faults detection based on steam generator model (증기발생기 모델을 이용한 계통 및 계측기 고장검출에 관한 연구)

  • Kim, Jung-Soo;Lyou, Joon;Na, Nan-Ju;Kwon, Kee-Choon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.250-255
    • /
    • 1993
  • In this paper, for detection and isolation of instrument and process faults related with steam generator(S/G) in nuclear power plant, two types of observers are designed based on the linearized dynamic model of S/G : a bank of Dedicated Observers (DOS) for instrument faults detection and a bank of Unknown Input Observers(UIO) for process faults detection. And then, they are combined to decide which one between the above two faults occurs. In principle, the failure in ith instrument(process) can be isolated by monitoring the error between the ith output and its estimation obtained from the ith DOS(UIO). It is shown via computer simulations that the present scheme is feasible in finding out the source of a fault.

  • PDF

The Study of FUSE Installing of PT in the trend of Digitalization and Convergence of Power Machinery. (디지탈화 및 복합화된 전력기기 변성기용 퓨즈 설치의 문제점)

  • Ok Yeon Ho;Lee Hyoung Mook;Hong Yeong Jae;Lee Eun Woong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.357-359
    • /
    • 2004
  • Fuse is the initial equipment of Protective Relay The installation standard of Fuse has been used for long time in Power Facilities. However according to the innovative development of Electric & Electronic element(=semiconductor) Technology, Protective Relay and other Power Equipments are being changed into Digitalization and Multi-Functional Convergence. In contrast with it, the installation standard of Fuse is just the same. There is a need to give careful consideration to it. This study will bear a Part of producing a safe and efficient Power by examining the current installation of primal 8f secondary 1'use in multi-functional PT of Power plant, giving a problem careful consideration and suggesting suitable countermeasures.

  • PDF

A Study on the Hydraulic Turbine Governor using Automatic Tuning Fuzzy Controller (자동 동조 퍼지 제어기를 이용한 수력 발전소 조속기 연구)

  • Lee, Seon-Geun;Lee, Won-Yong;Shin, Dong-Ryul;Kwon, Oh-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.265-268
    • /
    • 1992
  • The control performances of a fuzzy controller depend on its control rules, I/O membership functions, and scaling factors. Scaling factors are very important to adjust control parameters to the process which is to be controlled. For tuning the sealing factors, trial and error method is used in conventional fuzzy controller, which is very difficult and time consuming. This paper proposes a tuning method of scaling factors based on the concept of tuning rules for the conventional Pl controller parameters. The proposed automatic tuning fuzzy controller was evaluated by computer simulations. Good results have been obtained for the small hydro power plant.

  • PDF

Cycle Simulations for Power Saving BIP(block ice plant) design (절전형 제빙시설 설계를 위한 사이클 모사)

  • Kang, Jong-Ho;Kim, Nam-Jin;Lee, Jae-Yong;Kim, Chong-Bo
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.216-221
    • /
    • 2000
  • Most Ice making companies make simple efforts to make products and fail to introduce improvements into the system against huh cost of products. The work presented here is an implementation of ice making method to improve both energy efficiency and productivity. In this present investigation, several ice making cycles are designed and calculated to evaluate COP, ice making time and electric energy consumption. Results obtained shows that COP is improved with more efficient use of time for ice making and electric consumption. Therefore this can offer the opportunity for more efficient energy consumption and productivity in ice making.

  • PDF

Compensation of Sun Tracking Error caused by the Heliostat Geometrical Error through the Canting of Heliostat Mirror Facets (반사거울 설치 방향 조정에 의한 Heliostat 기구오차에서 기인하는 태양추적오차의 보정)

  • Park, Young-Chil
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.22-31
    • /
    • 2009
  • Canting is the optical alignment of mirror facets of heliostat such that the heliostat could focus the energy as a unit concentrator. Canting could improve the optical performance of heliostat and thus improves the efficiency of heliostat and ultimately improves the efficiency of the solar thermal power plant. This study discusses the effect of mirror canting, especially off-axis canting, used to compensate the sun tracking error caused by the heliostat geometrical errors. We first show that the canting could compensate the sun tracking error caused by the heliostat geometrical errors. Then we show that the proper canting time could exist, depending on the heliostat location. Finally we show how much the sun tracking performance could be improved by canting, by providing RMS sun tracking error. The limitation and caution of using canting to improve the sun tracking performance are also discussed.

Energy Regression Analysis for Economic Evaluation of Cooling Plants (냉방열원의 경제성 평가를 위한 건물에너지 회귀식 산출)

  • 김영섭;김강수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.377-384
    • /
    • 2002
  • For economic evaluation of cooling plant equipments, it is necessary to simplify energy Prediction method, which should includes efficiency corrected by part-load ratio. This study proposed simplified method with regression equations of time-average partial loads and refrigerator capacity. DOE-2 Program was used to carry out a parametric study of twelve design variables. Five input variables were considered to be significant and were used in the regression equations. To test accuracy of simplified method, calculated results were compared with DOE-2 simulated results. Test result showes a good agreement with the simulation result with an error of 5.9∼7.6%. It is expected that this method can be used as an easy prediction tool for comparing energy use of different cooling plants during the early design stage.

Analysis of Impulse Turbine for Wave Energy Conversion Using CFD Method (수치해석을 이용한 파력발전용 임펄스 터어빈의 성능해석)

  • HYUN BEOM-SOO;MOON JAE SEUNG
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.5
    • /
    • pp.1-6
    • /
    • 2004
  • This paper deals with the performance analysis and design of impulse turbine for owe type wave energy plant. Numerical analysis is performed using a commercial software FLUENT. This parametric study includes the variation of several important parameters, such as the number and shape of blades, hub ratio, and tip clearance. Since parametric study at various flow coefficients requires a considerable amount of computing time, two-dimensional analysis is employed to find out optimum principal particulars. Full three-dimensional calculations are also performed for several test cases, in order to confirm the validity of the two-dimensional approach. Up to the present stage, tentative results are demonstrated the usefulness of 2-D analysis.

Development of Safety Competences, Behavioral Indicators and Measuring Methods for Preventing Human-Error in Nuclear Power Plants: A Preliminary Study (원전 인적오류 예방을 위한 안전 역량, 행동 지표 및 측정 방법 개발: 예비 연구)

  • Moon, Kwangsu;Kim, Sa Kil;Lee, Yong-Hee;Jang, Tong Il
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.1
    • /
    • pp.132-138
    • /
    • 2016
  • The purpose of this study was to develop safety competences, a set of behavioral indicators of each competence and measuring methods of behavioral indicators for preventing human error of nuclear power plants(NPPs). The safety competences and behavioral indicators were derived from the five steps consisted of derivation of preliminary competence items through literature review, content analysis, interview(FGI, BEI), examination of content validity and decision making of final indicators. The results showed that 13 core safety competences and 35 behavior indicators were derived finally. In addition, the methods of measuring safety competences or behavioral indicators such as Behaviorally Anchored Rating Scale (BARS), Behavior Observation Scale (BOS) were developed and suggested.

Experimental Study on the MIMO Control Algorithm of a Multi-Heat Pump Based on PRBS Identification Scheme (PRBS 시스템 규명 기법 적용 멀티 열펌프의 다중입출력 제어특성에 관한 실험적 연구)

  • Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.2
    • /
    • pp.16-24
    • /
    • 2013
  • A multi-heat pump provides the benefits of comfort, energy conservation and easy maintenance. Recently, the multi-heat pump has been widely employed in small and medium-sized buildings. However, the control algorithm of the multi-heat pump are limited in the open literature due to complicated operating conditions. In this study, the MIMO control algorithm using integral optimum regulator was designed and the control performance of it was analyzed. In addition, system model of the control plant was developed by PRBS system identification scheme. The MIMO controller adopting the integral optimum regulator yielded satisfactory control performance results.

Assessment of Creep-Fatigue Crack Growth for a High Temperature Component (고온 기기의 크리프-피로 균열성장 평가)

  • Lee, Hyeong-Yeon;Kim, Jong-Bum;Lee, Jae-Han
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.264-268
    • /
    • 2008
  • An assessment of creep-fatigue crack behavior is required to ensure the structural integrity for high temperature components such as fast breeder reactor structures or thermal power plant components operating at an elevated temperature. In this study, an evaluation of creep-fatigue crack growth has been carried out according to the French assessment guide of the RCC-MR A16 for austenitic stainless steel structures. The assessment procedures for creep-fatigue crack growth in the recent version of the A16 (2007 edition) have been changed considerably from the previous version (2002 edition) and the material properties (RCC-MR Appendix A3) have been changed as well. The impacts of those changes on creep-fatigue crack growth behavior are quantified from the assessments with a structural model. Finally the assessment results were compared with the observed images obtained from the structural tests of the same structural specimen.

  • PDF