Analysis of Impulse Turbine for Wave Energy Conversion Using CFD Method (수치해석을 이용한 파력발전용 임펄스 터어빈의 성능해석)

  • Hyun, Beom-Soo;Moon, Jae-Seung
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.81-86
    • /
    • 2003
  • This paper deals with the performance analysis and design of impulse turbine for OWC type wave energy plant. Numerical analysis was performed using a commercially-available software FLUENT. This parametric study includes the variation of several important parameters such as the number and shape of blades, hub ratio and tip clearance. Since parametric study at various flow coefficients requires considerable amount of computing tim, two-dimensional analysis was employed to find out optimum principal particulars in rather simple manner. Full three-dimensional calculation was also performed for several test cases to confirm the validity of two-dimensional approach. Up to the present stage, tentative result is well demonstrating the usefulness of 2-D analysis.

  • PDF

Numerical Analysis for Unsteady Thermal Stratified Turbulent Flow in a Horizontal Circular Cylinder

  • Ahn, Jang-Sun;Ko, Yong-Sang;Park, Byeong-Ho;Youm, Hag-Ki;Park, Man-Heung
    • Nuclear Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.405-414
    • /
    • 1996
  • In this paper, the unsteady 2-dimensional turbulent flow model for thermal stratification in a pressurizer surge line of PWR plant is proposed to numerically investigate the heat transfer and flow characteristics. The turbulence model is adapted to the low Reynolds number K-$\varepsilon$ model (Davidson model). The dimensionless governing equations are solved by using the SIMPLE (Semi-Implicit Method for Pressure Linked Equations) algorithm. The results are compared with simulated experimental results of TEMR Test. The time-dependent temperature profiles in the fluid and pipe nil are shown with the thermal stratification occurring in the horizontal section of the pipe. The corresponding thermal stresses are also presented. The numerical result for thermal stratification by the outsurge during heatup operation of PWR shows that the maximum dimensionless temperature difference is about 0.83 between hot and cold sections of pipe well and the maximum thermal stress is calculated about 322MPa at the dimensionless time 28.5 under given conditions.

  • PDF

Numerical Analysis on Letdown System Performance Test for YGN 3

  • Seo, Ho-Taek;Sohn, Suk-Whun;Seo, Jong-Tae;Boo, Jung-Sook
    • Nuclear Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.158-166
    • /
    • 1997
  • Integrated performance test of Chemical and Volume Control System was successfully performed in 1994. However, an extensive effort to correct hardware and software problems in the letdown line was required mainly due to the lack of adequate simulation code to predict the test accurately. Although the LTC computer code was used during the YGN 3'||'&'||'4 NSSS design process, the code can not satisfactorily predict the test due to it insufficient letdown line modeling. This study developed a numerical model to simulate the letdown test by modifying the current LTC code, and then verified the model by comparing with the test data. The comparison shows that the modified LTC computer code can predict the transient behavior of letdown system lese very well. Especially, the model was verified to be able to predict the "Stiction (composition of stick and friction)" phenomena which caused instantaneous fluctuations in the letdown backpressure and flowrate. Therefore, it is concluded that the modified LTC computer code with the ability of calculating the "Stiction" phenomena will be very useful for future plant design and test predictions.predictions.

  • PDF

Environmental Effect Analysis for PV system using LCA (LCA를 이용한 태양광발전의 환경영향분석)

  • Choi, Bong-Ha;Park, Soo-Uk;Lee, Deok-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.737-741
    • /
    • 2007
  • This paper analyses the environmental effect of 100kw PV system installed in Tibet using Life Cycle Assessment(LCA). Then, energy payback time(EPT) and life-cycle $CO_2$ emission rate are estimated based on life-cycle of the PV system. As a result of the estimation, 6 year of EPT and 20 g-C/kWh of $CO_2$ emission rate are obtained. In China, average $CO_2$ emission rate of fossil fuel power generation plant is 260 g-C/kWh. This shows that PV system would be very promising for global environmental issues. For advanced LCA, we need to collect detailed and various data about raw material of PV system.

  • PDF

Traffic Test Method for Networked Control System (네트워크 기반 제어시스템의 통신부하 시험방법)

  • Yu, Kwang-Myung;Kim, Jong-An;Ryu, Ho-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.688-695
    • /
    • 2013
  • Networked Control Systems(NCS) contain the structure which controllers, actuators and sensors are connected to communication network. And they have been adopted in large and complicated plant area due to the advantages of mitigating computational bottleneck and maintenance. Although this structure provides many benefits, it brings in problems of unpredictable communication delay, data loss and corruption. This phenomena have to be considered in designing NCSs since it affects on overall control system stability. This paper introduces network traffic test method for ethernet based NCSs to find out maximum network usage which guarantee stable control operation. Test results shows this methods can be adopted in various types of NCSs and contributes economical system design and effective system operation.

A STUDY OH THE ECONOMIC OPERATION OF SMES FOR ENERGY STORAGE (전력 저장용 SEMS의 경제적 운용에 관한 연구)

  • Roh, Hee-Ho;Hahn, Song-Yop;Rhee, Sung-Won
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.13-16
    • /
    • 1988
  • As the automic power plant is increased, load leveling energy storage system becomes more important. Pumped hydroelectric storage, used in the present, has too storage efficiency and difficulty in selecting site. But SMES(Superconducting Magnet Energy Storage) has high storage efficiency (90%), fast time response characteristics and ease of location. The general object of SMES with electric power system is the minimization overall production cost. This paper presents a method for the economic operation of SMES by Dynamic Programming.

  • PDF

NPP I&C Architecture Design and Its Traffic Load Analysis

  • Lee, Cheol-Kwon;Kim, Dong-Hoon;Oh, In-Seok;Shin, Jae-Hwal;Yun, Jae-Hee;Sur, Joong-Surk
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.75-77
    • /
    • 2005
  • An integrated I&C architecture for nuclear power plants is designed by the systems and devices being developed in a project. Its design reference is the APR1400 that was design certified in Korea. Digital equipment and several kinds of data communication networks (DCN) are used. To confirm the validity of DCN based architecture design, the traffic loads fur each network were calculated assuming the anticipated maximum traffic condition. The analysis showed that the utilizations of all networks satisfied the design requirements.

  • PDF

VOLUME REDUCTION OF DISMANTLED CONCRETE WASTES GENERATED FROM KRR-2 AND UCP

  • Min, Byung-Youn;Choi, Wang-Kyu;Lee, Kune-Woo
    • Nuclear Engineering and Technology
    • /
    • v.42 no.2
    • /
    • pp.175-182
    • /
    • 2010
  • As part of a fundamental study on the volume reduction of contaminated concrete wastes, the separation characteristics of the aggregates and the distribution of the radioactivity in the aggregates were investigated. Radioisotope $^{60}Co$ was artificially used as a model contaminant for non-radioactive crushed concrete waste. Volume reduction for radioactively contaminated dismantled concrete wastes was carried out using activated heavy weight concrete taken from the Korea Research Reactor 2 (KRR-2) and light weight concrete from the Uranium Conversion Plant (UCP). The results showed that most of the $^{60}Co$ nuclide was easily separated from the contaminated dismantled concrete waste and was concentrated mainly in the porous fine cement paste. The heating temperature was found to be one of the effective parameters in the removal of the radionuclide from concrete waste. The volume reduction rate achieved was above 80% for the KRR-2 concrete wastes and above 75% for the UCP concrete wastes by thermal and mechanical treatment.

Environmental Conservation and Wood Utilization (환경보호와 목재의 이용)

  • Jang, Sang-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.51-58
    • /
    • 1994
  • Environmental conservation has become one of the greatest concerns of all the people in the world. This issue is related to wood utilization in two major view points such as carbon dioxide emitted by the use of manufacturing energy and absorbed during the growth of trees. Wood construction materials require less manufacturing energy, which, in turn, means less carbon dioxide emission. In addition, wood keeps absorbed carbon in itself as far as it is not burnt. Therefore, wood is environmentally superior to other materials in terms of potential effects on atmospheric carbon dioxide. As examples of the environmental effect of wood utilization, the following two results were obtained: 1) If wood construction becomes popular in Korea as in Japan, more than 24% of carbon dioxide emission during construction of residential housings can be reduced: and 2) If aluminum windows are substituted by wood windows, more than 19% of carbon dioxide emission can be reduced. If the principle of "cut and plant" is kept well, wood is the best construction material for environmental protection as well as human residence.

  • PDF