• Title/Summary/Keyword: Energy plant

Search Result 3,892, Processing Time 0.029 seconds

Sequestration of Orthophosphate by D(+)-Mannose Feeding Increases Nonphotochemical Quenchings in Chinese Cabbage Leaves (Mannose 처리된 배추 잎의 무기인산 감소에 따른 비광화학성 소산의 증가)

  • 박연일
    • Journal of Plant Biology
    • /
    • v.34 no.4
    • /
    • pp.303-309
    • /
    • 1991
  • Limitation of photosynthesis in detached Chinese cabbage (Brassica campestris L.) leaves was induced by feeding of mannose (25 mM) for 12 h in the light, and changes in the basic thylakoid functions under this condition were investigated. The acid soluble phosphate contend and CO2 uptake rate was decreased by 66% and 67%, respectively. However, the starch content was increased by 24% compared to those of controls. From the fast induction curves of chlorophyll fluorescence, dark level fluorescence (Fo) slightly increased while intermediate plateau fluorescence level (FI) to peak level fluorescence (Fp) transient was significantly decreased with a slight decrease in the Fo-to-FI transient. This data means that reduction of secondary electron acceptor of PSII (QB) might be more severely inhibited than that of primary electron acceptor of PSII (QA) by decrease in phosphate level. The strong decline of (Fv)m//Fm ratio suggests that efficiency of excitation energy capture by PSII was decreased markedly. The quenching of Fo (qO), an indicator of state transition, was also occurred over the slow induction kinetics of chlorophyll fluorescence. From quenching analysis, fluorescence was dominantly quenched by nonphotochemical quenchings (qE+qT). These results showed that the capture and transfer efficiency of excitation energy to PSII reaction center in thylakoid was decreased with the decline of leaf phosphate level, and that the state transition was occurred during the induction of photosynthesis under these conditions.

  • PDF

On the Accumulation of Radioactive Materials in Marine Organisms Along the Coast of Korea 3. Cesium-137 Activities in Several Edible Marine Algae

  • Yang, Kyung Rin;Pak, Chan Kirl;Lee, In Kyu
    • 한국해양학회지
    • /
    • v.10 no.2
    • /
    • pp.51-56
    • /
    • 1975
  • Continued to the previous papers, the present investigation is carried out to clarify cesium-137 activities and potassium contents among 54 samples of edible marine algae collected along the coast of Korea during September, 1973 and April, 1974. The potassium contents are variable, 1.5-29.6%, and 11.36% on an average, while most of the members contain them about 10-16% generally. Among the algal phyla, they are 13.49% in green, 10.82% in brown and 16.46% in red algae, respectively. Cesium-137 activities are variable, 0.19-8.13 pCi$\^$137/ Cs/g K, and 2.35 pCi$\^$137/Cs/g K on an average in the samples investigated. Among the algal phyla they are 4.35 in green, 2.17 in brown and 0.89 pCi $\^$137/Cs/g K in red algae, respectively. Green algae contain especially higher activities compared with the other two groups. The brown alga, Myelophycus caespitosus shows the highest activities, 8.13 pCi$\^$137/Cs/g K, among the members investigated. Considering the concentration factor, this plant would be an indicator plant of cesium-137 among the marine algae along the coast of Korea.

  • PDF

Internal Flow Analysis for a 10 inch Ball Valve using Flow Similarity (유동상사를 이용한 10인치 볼밸브 내부유동 분석)

  • LEE, SANG-MOON;JANG, CHOON-MAN
    • Journal of Hydrogen and New Energy
    • /
    • v.26 no.4
    • /
    • pp.386-392
    • /
    • 2015
  • Flow characteristics inside a 10 inch ball valve have been analyzed using three-dimensional numerical analysis and experiments. Continuity and three-dimensional Reynolds-averaged Navier-Stokes equations have been used as governing equations for the numerical analysis. The numerical model has been constructed through the grid dependency test and validation with the results of experiments to ensure reliability and numerical effectiveness. The shear stress transport (SST) model has been used as the turbulence closure. The experimental test-rig has been constructed to measure pressure, temperature and flow rate along the pipeline. Some valve opening angles have been tested to evaluate the flow characteristics inside the ball valve and pipeline. The results show that the rapid pressure variations is observed while the valve opening angle decreases, which caused by flow separation at the downstream of the ball valve.

An Accelerated Degradation Test of Nuclear Power Plants Communication Cable Jacket (원자력 발전소용 통신케이블 자켓의 가속열화시험)

  • Jung, Jae Han;Kim, Yong Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.4
    • /
    • pp.969-980
    • /
    • 2017
  • Purpose: The purpose of this study was to estimate the lifetime, and verify the target lifetime at steady state temperature, of communication cable jackets used in nuclear power plants. Method: This study was completed according to test and analysis methods required by international standards. After measuring the residual elongation(%) of specimens at specific points in time with the accelerated degradation test, average failure time of each temperature was computed. Thus, the activation energy could be derived by applying the temperature-Arrhenius law to estimate cable jacket lifetime at steady state temperature. Results: The cable jacket lifetime was estimated as 363.8 years assuming a normal nuclear power plant operating temperature of $90^{\circ}C$. Conclusion: To ascertain stable operating conditions for a nuclear power plant, accelerated degradation tests were performed according to the Arrhenius law for components of the nuclear power plants. The lifetime was estimated from the degradation data collected during the accelerated degradation test.

A study on regional capacity factor of Photovoltaic Power Plant (태양광 발전소 지역별 이용률 분석에 대한 고찰)

  • Choi, Byung-Cheon;Kwak, Wang-Shin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.110-113
    • /
    • 2008
  • 태양광 발전은 태양에너지를 직접 전기에너지로 변환시키는 설비로서 Co2 발생이 적고 에너지원인 태양에너지가 무한하다는 장점이 있다. 현재 EU를 비롯한 선진국 및 개도국에서는 신재생에너지 확대를 위해 전 국가적으로 노력하고 있으며 특히 태양광 발전분야는 전 세계적으로 설비용량이 급증하고 있다. 국내에서도 발전차액지원제도 하에 태양광 발전설비를 확충하고 있으며, 정부가 발표한 1차국가에너지 기본계획에 의하면 2030년까지 3,504 MW로 공급규모를 확대할 방침이다. 그러나 현재 태양광 발전은 에너지 변환효율은 약 15%이며 날씨와 시간에 따라 발전에 제약이 따른다. 이에 태양광 발전의 신뢰성을 확보하기 위해 국내 발전차액지원을 받고 있는 태양광 발전소의 연간 발전량을 근거하여 이용률을 분석했다. 분석결과 일사량이 풍부한 전남지역의 이용률이 가장 높고,반대로 경기와 서울지역은 저조했으며, 연평균 15.70%의 이용률을 보였다. 한편 월간 이용률은 5월에 높게 나타났으며, 연중 최대 전력수요가 나타나는 7-9월에는 기상조건으로 인해 저조한 이용률을 보였다. 따라서 기후변화를 완화하고 저탄소 녹색성장을 구현하기 위해 기술개발을 통해 태양광 이용률 증대시켜야 한다.

  • PDF

An Approach for Reducing Carbon-14 Stack Emissions via Optimal Use of Ion Exchang Resins at CANDU Plant

  • Sohn, Wook;Chi, Jun-Ha;Kang, Duk-Won
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.445-455
    • /
    • 2003
  • Relatively high carbon-14 emissions, which occurred at PHWR Plant during 1998 and 1999, made the site staff to implement several operational improvements: 1) the frequency and volume of the moderator cover gas purging were reduced through increased $O_2$ additions to the cover gas, 2) the 'old' resin columns were not used during re-start of the reactor from outage, 3) efforts were made to minimize air ingress, 4) the maximum service time of moderator ion-exchange columns were restricted to about 80 days. Through the improvements, the carbon-14 emission from each PHWR reactor returned to the normal levels during the remainder of 1999 and during 2000. We carried out a special surveillance at W-1 and W-3 from September 2001 to August 2002 to properly evaluate ways to optimize the use of moderator ion exchange resins from a C-14 perspective. The surveillance showed that only data that provided an operational marker for deciding when to remove the IX-resin column is an observed increase in the C-14 stack emissions themselves. Also, it is shown that any increase over the rate of 0.4 Ci $month^{-1}$ for two consecutive weeks may be the indication for an ion-exchange resin column change, especially if the IX-resin column has been in service for more than 80 days.

  • PDF

A study of the STEP-based Data Repository and P&ID-3D CAD Model Connected Pilot System at Nuclear Power Plant (원전 대상의 STEP 기반 데이터 저장소 및 P&ID와 3차원 CAD 모델 연계에 관한 연구)

  • 안호준;조광종;박찬국;한순홍;안경익;최영준
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2004.05a
    • /
    • pp.395-400
    • /
    • 2004
  • This study is that STEP based Data Repository of APR1400 Nuclear Power Plant Reactor Coolant System is developed. The STEP based Data Repository is accessed by Web-based and an attribute data of Reactor Coolant System Equipment is offered. Also, a P&ID drawing file & 3D CAD Model of Reactor Coolant System is loaded. The P&ID drawing file of Reactor Coolant System Equipment Model is connected with 3D CAD Model file. This 2D/3D CAD Model connected Prototype system confirms a real layout of Reactor Coolant System.

  • PDF

The Effect of Temperature Reduction as Influenced by Rooftop Greening (옥상녹화조성에 따른 온도저감효과에 관한 연구 -서울대학교 실험구를 중심으로-)

  • Lee, Dong-Kun;Yoon, So-Won;Oh, Seung-Hwan;Jang, Seong-Wan
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.6
    • /
    • pp.34-44
    • /
    • 2005
  • The objective of this study is to analyze the thermal properties of various green roof type. The experimental districts, have different soil thickness, soil type, the existence of module and the different kinds of vegetation, had installed. A measurement was conducted in Seoul University to investigate the thermal impacts of rooftop greening. The measurement point of temperature were 30, located in soil surface, middle of the soil layer, under the module, hard surface and soffit surface of each experimental district. The experimental investigation lasted from 6th August to 29th August, a total of 24 days. The results showed that green roof can contribute thermal benefits by soil and vegetation and reduce building energy consumption by a role of insulation. It's also better to make soil thickness over 20cm and various vegetation that should be more effective. The district installed only soil also could be effective for reducing the temperature of roof surface. Therefore, the increase of soil thickness and various vegetation could reduce more temperature of roof surface and building energy consumption. Also, it's helpful to reduce temperature that plant coverage rate be raised.

Prognostics for integrity of steam generator tubes using the general path model

  • Kim, Hyeonmin;Kim, Jung Taek;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • v.50 no.1
    • /
    • pp.88-96
    • /
    • 2018
  • Concerns over reliability assessments of the main components in nuclear power plants (NPPs) related to aging and continuous operation have increased. The conventional reliability assessment for main components uses experimental correlations under general conditions. Most NPPs have been operating in Korea for a long time, and it is predictable that NPPs operating for the same number of years would show varying extent of aging and degradation. The conventional reliability assessment does not adequately reflect the characteristics of an individual plant. Therefore, the reliability of individual components and an individual plant was estimated according to operating data and conditions. It is essential to reflect aging as a characteristic of individual NPPs, and this is performed through prognostics. To handle this difficulty, in this paper, the general path model/Bayes, a data-based prognostic method, was used to update the reliability estimated from the generic database. As a case study, the authors consider the aging for steam generator tubes in NPPs and demonstrate the suggested methodology with data obtained from the probabilistic algorithm for the steam generator tube assessment program.

Simulation of Multiple Steam Generator Tube Rupture (SGTR) Event Scenario

  • Seul Kwang Won;Bang Young Seok;Kim In Goo;Yonomoto Taisuke;Anoda Yoshinari
    • Nuclear Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.179-190
    • /
    • 2003
  • The multiple steam generator tube rupture (SGTR) event scenario with available safety systems was experimentally and analytically evaluated. The experiment was conducted on the large scaled test facility to simulate the multiple SGTR event and investigate the effectiveness of operator actions. As a result, it indicated that the opening of pressurizer power operated relief valve was significantly effective in quickly terminating the primary-to-secondary break flow even for the 6.5 tubes rupture. In the analysis, the recent version of RELAP5 code was assessed with the test data. It indicated that the calculations agreed well with the measured data and that the plant responses such as the water level and relief valve cycling in the damaged steam generator were reasonably predicted. Finally, sensitivity study on the number of ruptured tubes up to 10 tubes was performed to investigate the coolant release into atmosphere. It indicated that the integrated steam mass released was not significantly varied with the number of ruptured tubes although the damaged steam generator was overfilled for more than 3 tubes rupture. These findings are expected to provide useful information in understanding and evaluating the plant ability to mitigate the consequence of multiple SGTR event.