• Title/Summary/Keyword: Energy plant

Search Result 3,892, Processing Time 0.028 seconds

Studies on the Behaviour of Radionuclides in the Soil-Plant System;1) On the Uptake of Cesium-137 by Soybean (토양(土壤)-식물계(植物界)에 대(對)한 방사성핵종(放射性核種)의 거동(擧動)에 관(關)한 연구(硏究);I. 대두작물(大豆作物)에 의(依)한 Cs-137의 흡수이행(吸收移行))

  • Ryu, Joon;Kim, Jae-Sung;Lee, Young-Il
    • Korean Journal of Environmental Agriculture
    • /
    • v.2 no.1
    • /
    • pp.30-34
    • /
    • 1983
  • The present study was carried out to determine the effect of a radionuclide, cesium-137, in soybean, which is an element released usually from nuclear facilities. Soybean plants were grown on the pots treated with cesium-137 $0.5{\sim}60{\mu}Ci/1kg$ soil and the uptake, translocation and accumulation of the radiocesium in the plant parts were measured at different growth stage. The results are summarized as follows: 1) Visual toxic symptoms on the plants due to treatment of radioactive cesium were not observed up to $60{\mu}Ci/10Kg$ soil in a pot. 2) The uptake of cesium-137 in soybean plant was increased with increment of concentration applied, while the uptake of potassium was proportionally decreased, indicating to have an ion antagonistic relationship between them. 3) The absolute amounts of cesium-137 in the plants were gradually increased by the pod setting stage, but rather reduced at harvesting stage. The accumulation occurred more in the leaves and stems than the soybean seeds. 4) The rate of uptake was ranged from 0.069 to 0.005 with proportional decrease by increasing concentration applied and the rate of Cs-137 translocation from plants to seeds was averaged 38.6% in soybean plant. The concentration coefficient was 0.04 in the soybean seeds from the pots treated with $20{\mu}Ci$ of cesium-137 and decreased with increment of cesium-137 applied.

  • PDF

Comparison of Combined Light-emitting Diodes and Fluorescent Lamps for Growth and Light Use Efficiency of Red Leaf Lettuce (혼합 발광다이오드와 형광등에서 자란 적치마 상추의 생육 및 광 이용 효율 비교)

  • Son, Ki-Ho;Song, Min-Jeong;Oh, Myung-Min
    • Journal of Bio-Environment Control
    • /
    • v.25 no.3
    • /
    • pp.139-145
    • /
    • 2016
  • The objective of this study was to compare the growth and light use efficiency of red leaf lettuce grown under three types of combined light-emitting diodes (LEDs) and fluorescent lamps (FL) in a closed-type plant production system. The eighteen days-old lettuce seedlings of red leaf lettuce (Lactuca sativa L., 'Jeokchima') were transplanted to the close-type plant production system equipped with three types of combined LEDs with red (R, 655 nm), blue (B, 456 nm), green (G, 515 nm), and white (W, 456 nm + 558 nm) (R:B=8:2, R:W:B=8:1:1, R:G:B=8:1:1) and FL. The seedlings were grown under normal growth conditions ($20^{\circ}C$, $181{\pm}4{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, 12 h photoperiod) for four weeks. Lettuce plants grown under FL had significantly higher leaf shape index than those under all LED treatments. Although growth of shoots and roots was not show any significant difference among LED treatments, all of the LED treatments induced about 34% higher shoot fresh weight than that of the FL. On the other hands, the total power consumption of FL was 145 kW for 4 weeks, while the mean value of LED treatments was 54 kW, which was about 3 times lower value than that of the FL. The light use efficiency based on dry matter in LED treatments was about 34 mg/W and this was about 3.5 times higher energy saving value than the FL. In conclusion, this study showed that irradiation of optimal combined LEDs in closed-type plant production systems can improve the lettuce growth as well as maximize in light use efficiency through energy saving than the FL.

Performance Analysis on the Multi Stage Reheater Regeneration Cycle for Ocean Geothermal Power Generation (해양지열발전용 다단재열재생사이클 성능해석)

  • Lee, Ho Saeng;Cha, Sang Won;Jung, Young Kwon;Kim, Hyeon Ju
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.2
    • /
    • pp.116-121
    • /
    • 2014
  • In order to study the improvement of the multi stage regeneration cycles, muti-stage processes were applied to the cycles, respectively or together. The kinds of the cycles are multi stage reheater cycle (MS) and multi stage reheater regeneration cycle (MSR). Working fluid used was R134a and R245fa. Temperature of the heat source was $65^{\circ}C$, $75^{\circ}C$, and $85^{\circ}C$, and temperature of the heat sink was $5^{\circ}C$. Optimization simulation was conducted for improving the gross power and efficiency with multi stage reheater regeneration cycle for ocean thermal energy conversion(OTEC) with changing of a heat source, kind of the working fluid, and type of the cycle. Performance analysis of the various components was simulated by using the Aspen HYSYS for analysis of the thermodynamic cycle. R245fa shows better performance than R134a. This paper showed the most suitable working fluid with changing of a heat source and the kinds of working cycle. Compared to each other, MS showed better performance at gross power and MSR showed higher cycle efficiency.

Floating Photovoltaic Plant Location Analysis using GIS (GIS를 활용한 수상 태양광 발전소 입지 분석)

  • Lee, Ki Rim;Lee, Won Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.1
    • /
    • pp.51-59
    • /
    • 2016
  • Global consumption of fossil fuels continues to increase. As developing countries use fossil fuel as much as the existing fossil fuel using countries, the total amount of fossil fuel consumed has risen. The finite fossil energy depletion insecurity have become serious. In addition, fossil energy is caused by environmental pollution, economic and social problems remain in assignments that need to be addressed. Although solar power is clean and has many benefits, there are several problems in the process of installing a solar power plant. To solve these problems, floating photovoltaic plants has emerged as an alternative. This floating photovoltaic plants location analysis has not been made yet. In this study, the conditions of the floating photovoltaic plants location is analyzed with the Analytic Hierarchy Process using the terrain and climate factors. The score is assigned to the attribute information of each factor by the classification table. After multiplied by the weight the result is analyzed by visualization of the score. As the result, the score of the northen part of Gyeongsangbuk-do province is higher than the southern part of Gyeongsangbuk-do province. Especially Andongho lake in Andong City and the reservoir in Yeongyang-Gun are extracted as the optimal location. The score of the river boundary is low not the center of the river stream. It is expected that this study would be a more accurate floating solar power plant location analysis.

Experimental Investigation on the Change of Water Discharge Capability of Sluice Caisson for Tidal Power Plant Placed on the Rubble Mound (사석마운드 위에 설치되는 조력발전용 수문 케이슨의 통수성능에 대한 실험적 연구)

  • Lee, Dal-Soo;Oh, Sang-Ho;Lee, Jin-Hak;Park, Woo-Sun;Cho, Hyu-Sang;Eum, Hyun-Min
    • New & Renewable Energy
    • /
    • v.4 no.2
    • /
    • pp.94-104
    • /
    • 2008
  • The change of water discharge capability of sluice caisson for tidal power plant according to installation of the rubble mound was investigated by performing laboratory experiment. The experiment was carried out in an open channel flume with a great care to measure flow rate and water level in the flume accurately. Eight different sluice caisson models were used in the experiment. The water discharge capabilities of seven sluice models decreased with respect to the placement of the rubble mound, while increased for only one sluice model. On average, the values of discharge coefficient decreased by approximately 10% when the sluice models were placed on the rubble mound. It is concluded that the shape of the rubble mound can affect the water discharge capability of the sluice caisson, so that its shape should be significantly considered in the design of the sluice caisson, especially when it is deployed in a site of relatively deeper depth.

  • PDF

Storage and Delivery of Hydrogen Isotopes (삼중수소 저장기술)

  • Chung, Hong-Suk;Chung, Dong-You;Koo, Dae-Seo;Lee, Ji-Sung;Shim, Myung-Hwa;Cho, Seung-Yon;Jung, Ki-Jung;Yun, Sei-Hun
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.3
    • /
    • pp.372-379
    • /
    • 2011
  • A nuclear fusion fuel cycle plant is composed of various subsystems such as a hydrogen isotope storage and delivery system, a tokamak exhaust processing system, and a hydrogen isotope separation system. Korea shares in the construction of its ITER fuel cycle plant with the EU, Japan, and the US, and is responsible for the development and supply of the storage and delivery system. The authors thus present details on the development status of hydrogen isotope storage technologies for nuclear fusion fuel cycle plants. We have developed various hydride beds of different size. We have realized a hydrogen delivery rate of 12.5 $Pam^3/s$ with a typical 1242g-ZrCo bed.

A Buoyant Combined Solar-Wave Power Generation and Its Application for Emergency Power Supply of Nuclear Power Plant (부유식 태양광-파력 복합발전 개념 및 원자력발전소 비상전원을 위한 응용)

  • Cha, Kyung-Ho;Kim, Jung-Taek
    • New & Renewable Energy
    • /
    • v.7 no.4
    • /
    • pp.37-41
    • /
    • 2011
  • This paper presents a Combined solar-wave Power Generation (CPG) concept that the CPG unit is maintained as buoyant at the level of sea water and it is also supported by a submerged tunnel, with the aim of supplying emergency electric power during the station blackout events of nuclear power plants. The CPG concept has been motivated from the 2011 Fukushima-Daiichi Accidents due to the loss of both offsite AC power and emergency diesel power caused by natural hazards such as earthquake and tsunami. The CPG is conceptualized by applying different types and different sites for emergency power generation, in order to reduce common cause failures of emergency power suppliers due to natural hazards. Thus, the CPG can provide a new mean for supplying emergency electric power during station blackout events of nuclear power plants. For this application, the CPG requirements are described with a typical configuration at the ocean side of a submerged tunnel.

A Study of Numerical Reproducibility for the Backdraft Phenomena in a Compartment using the FDS (FDS를 이용한 구획실 백드래프트 현상의 수치적 재현성에 관한 연구)

  • Park, Ji-Woong;Oh, Chang Bo;Choi, Byung Il;Han, Yong Shik
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.6
    • /
    • pp.6-10
    • /
    • 2013
  • A numerical reproducibility of the backdraft phenomena in a compartment was investigated. The prediction performance of two combustion models, the mixture fraction and finite chemistry models, were tested for the backdraft phenomena using the FDS code developed by the NIST. The mixture fraction model could not predict the flame propagation in a fuel-air mixture as well as the backdraft phenomena. However, the finite chemistry model predicted the flame propagation in the mixture inside a tube reasonably. In addition, the finite chemistry model predicted well the backdraft phenomena in a compartment qualitatively. The flame propagation inside the compartment, fuel and oxygen distribution and explosive fire ball behavior were well simulated with the finite chemistry model. It showed that the FDS adopted with the finite chemistry model can be an effective simulation tool for the investigation of backdraft in a compartment.

Removal Characteristics of $SO_2$ in the Coal Combustion Flue Gas Treatment Convergence System (석탄화력발전소 현장의 석탄연소 배가스 고도처리용 건식 분류층 반응 실증장치에서의 $SO_2$ 제거성능 특성)

  • Jeon, Seong-Min;Park, Hyung-Sang;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.239-246
    • /
    • 2013
  • The purpose of this study is to determine the feasibility of dry-type desulfurization process for actual application to coal-fired power plant. We used actual exhaust gas from Facility Y, Plant #2 to fabricate a demo-scale testing device to attempt to improve the efficiency of desulfurization. A spout-bed circulating dry scrubber convergence system connecting turbo reactor with bag filter was devised, then analyzed for performance characteristics of $SO_2$ removal for Ca/S mole ratio, superficial gas velocity, and ammonia injection, and for secondary reaction characteristics of the non-reactive sorbent at the bag filter. As a result, the installation of spout-bed circulating dry scrubber convergence system showed better economy and efficiency for removing sulfur than the existing wet/semidry-type desulfurization process. In addition, the best efficiency for desulfurization occurred when connected to the bag filter, with differential pressure maintained at 150 $mmH_2O$.

A Study on Dynamic Test of Safety System Software on Nuclear Power Plant (원자력발전소 안전계통 소프트웨어의 동적시험에 관한 연구)

  • Moon, Chae-Joo;Chang, Young-Hak;Lee, Sun-Sung;Suh, Young
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.213-223
    • /
    • 1999
  • In recently, the safety system software of the nuclear power plant has been verified and validated according to ANSI/IEEE-ANS-7-4.3.2-1982 to improve the reliability. This standard requires that safety-related software should be tested in the static and dynamic environments. In case of Inadequate Core Cooling Monitoring System (ICCMS), the static test procedure and related techniques are developed but the dynamic test procedure and related techniques are not developed. Therefore, this paper discusses the undeveloped techniques, and suggests the dynamic test procedure and the program for generation of test input data. The performance of the program was identified using accident analysis report of Ulchin 3&4 Final Safety Analysis Report (FSAR).

  • PDF