• Title/Summary/Keyword: Energy per unit area

Search Result 172, Processing Time 0.028 seconds

Effects of Combining Feed Grade Urea and a Slow-release Urea Product on Performance, Dietary Energetics and Carcass Characteristics of Feedlot Lambs Fed Finishing Diets with Different Starch to Acid Detergent Fiber Ratios

  • Estrada-Angulo, A.;Lopez-Soto, M.A.;Rivera-Mendez, C.R.;Castro, B.I.;Rios, F.G.;Davila-Ramos, H.;Barreras, A.;Urias-Estrada, J.D.;Zinn, R.A.;Plascencia, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.12
    • /
    • pp.1725-1733
    • /
    • 2016
  • Recent findings have shown that microbial nitrogen flow and digestible energy of diets are increased when urea is combined with a slow-release urea (SRU) in diets with a starch to acid detergent fibre ratio (S:F) 4:1. This affect is attributable to enhanced synchrony between ruminal N availability for microbial growth and carbohydrate degradation. To verify the magnitude of this effects on lamb performance, an experiment was conducted to evaluate the effects of combining urea and a SRU in diets containing S:F ratios of 3:1, 4:1, or 5:1 on performance, dietary energetics and carcass characteristics of finishing lambs. For that, 40 Pelibuey${\times}$Katahdin lambs ($36.65{\pm}3kg$) were assigned to one of five weight groupings in 20 pens (5 repetition/treatments). The S:F ratio in the diet was manipulated by partially replacing the corn grain and dried distiller's grain with solubles by forage (wheat straw) and soybean meal to reach S:F ratios of 3:1, 4:1 or 5:1. An additional treatment of 4:1 S:F ratio with 0.8% urea as the sole source of non-protein nitrogen was used as a reference for comparing the effect of urea combination vs. conventional urea at the same S:F ratio. There were no treatment effects on dry matter intake (DMI). Compared the urea combination vs urea at the same S:F ratio, urea combination increased (p<0.01) average daily gain (ADG, 18.3%), gain for feed (G:F, 9.5%), and apparent energy retention per unit DMI (8.2%). Irrespective of the S:F ratio, the urea combination improved the observed-to-expected dietary ratio and apparent retention per unit DMI was maximal (quadratic effect, $p{\leq}0.03$) at an S:F ratio of 4:1, while the conventional urea treatment did not modify the observed-to-expected net energy ratio nor the apparent retention per unit DMI at 4:1 S:F ratio. Urea combination group tended (3.8%, p = 0.08) to have heavier carcasses with no effects on the rest of carcass characteristics. As S:F ratio increased, ADG, G:F, dietary net energy, carcass weight, dressing percentage and longissimus thoracis (LM) area increased linearly ($p{\leq}0.02$). Combining urea and a slow-release urea product results in positive effects on growth performance and dietary energetics, but the best responses are apparently observed when there is a certain proportion (S:F ratio = 4:1) of starch to acid detergent fibre in the diet.

A Study on the Performance of Flat-plate Solar Air Collector and its Application to Grain Drying (평면식 태양열집열기를 이용한 곡물 건조개선에 관한 연구)

  • 민영봉;최규홍
    • Journal of Biosystems Engineering
    • /
    • v.3 no.2
    • /
    • pp.114-125
    • /
    • 1978
  • The use of petroleum fuels in grain drying causes problems of high cost and management. To solve these problems, it is required to study on soLar energy as an alternative to petroleum fuels for grain drying. The purposes of this study were to find out the optimum received area and air flow rate of a flat-plate solar air collector for grain drying and to assess its effects on grain drying with a small grain bin. The results of this study are summarized as follows ; 1. The calculated optimum tilt angles of the collector in the summer and autumn drying seasons were 20 and 50 degress, respectively, in suwon area. 2. The outlet temperature of the collector was $36^\circ C$ on the daily average with the maximum of $36^\circ C$ at 12:00 o clock. Solar radiation on the collector surface was 1.04 ly( 1 langley = 1 cal/$cm^2$) per minute on the daily average and 1.30 ly per minute on the maximum at 11:00am. The thermal efficiency of the collector was 62.4 percent on the daily average, and the air flow-rate per unit receiving are was 1.03 $m^3$/min/$m^2$.4. The calculated optimum receiving area and the air flow-rate per unit cubic volume for paddy in autumn drying season was 2 $m^2$ and 2$m^3$/min , respectively. 5. not significantly difference in the collector efficiency was appeared between the rotating and fixed type of solar collector. 6. For drying of wheat with 0.6 meter of the depth in the bin, approximately 9 hours were required to reduce the moisture content from 21.6% to 13% with air follow rate of 5 $m^3$/min an initial moisture per cubic meter of wheat and with air temperature of $52^\circ C$. 7. In the drying test of rough rice with a turning operation in a grain bin approximately 21 hours were required to reduced the moisture from 21% to 14.5% with airflow rate of 2 $m^3$/min per cubic meter of rice and the air temperature of $43.5^\circ C$. 8. Over-drying at the bottom and less -drying at the top of the grain mass was resulted from the high -temperature of drying air which was obtained from the flat-plate solar collector in this test. An appropriate operation should be prepared for the uniform moisture of the grain in the bin.

  • PDF

Performance Evaluation of Fixed-concentrated Photovoltaic/Thermal Hybrid Panel using Reflector (반사판을 이용한 고정식 집속형 태양광.열복합패널의 성능평가)

  • Seo, Yu-Jin;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.85-92
    • /
    • 2005
  • One of the most effective methods for utilizing solar energy is to combine thermal solar and optical energy simultaneously using a hybrid panel. Many systems using various kinds of photovoltaic panels have already been constructed. But utilizing solar energy by means of a hybrid panel with concentrator has not been to be attempted yet. Normally if sunlight is directed on the solar cell, and there is no increase in temperature, the absorption energy of each cell will increase per unit area. In a silicon solar cell. however, cell conversion efficiency decreases according to the increasing temperature. Therefore, to maintain cell conversion efficiency under normal condition, it is necessary to keep the cell at operating temperature. we design and make new hybrid panel with cooling system to prevent increasing of temperature on cell, collect effectively thermal energy. We compared performance of new hybrid panel with PV module and thermal panel. We also evaluated conversion efficiency, electric power and thermal capacity and confirmed cooling effect from thermal absorption efficiency.

Irradiant Energy into an Eye from a Flash Light (섬광에 의하여 사람 눈에 입사되는 광 에너지)

  • Park, Seung-Man;Han, Seungoh
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1225-1230
    • /
    • 2016
  • Since a flash light produces enormous amount of photon energy in short time, not only electro-optic and infrared(EO/IR) systems utilized for Intelligence Surveillance Target Acquisition and reconnaissance(ISTAR) activities but also the people of a combat field can be severely influenced by a high flash light bursting in front of them. The people who bumped into a flash could not escape such enormous amount of photon energy, resulting in being blind temporarily or even permanently. In order to investigate the effect of a high flash source on a human eye, it is essential to know how much photon energy be incident into an eye from the flash source. In this paper, the model of irradiated photon energy to individuals from some flashes is proposed. The proposed irradiated photon energy per unit area of retina is based on taking the situation to be modeled as a simple EO system in front of a flash light. The validity of proposed model was proved by the application of the model to human on the surface of the earth with the well known light source, the Sun. The model of this study can be utilized to simulate the retinal intensity and energy of a flash for various conditions such as the illumination levels, the distance from a flash busting site, luminous intensity and time of a flash.

Selective Laser Sintering of WC-Co Mixture for Rapid Tooling (쾌속 금형 제작을 위한 텅스텐 카바이드와 코발트 혼합물의 선택적 레이저 소결)

  • Kim K. H.;Beaman Joseph J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.02a
    • /
    • pp.187-194
    • /
    • 2002
  • This paper describes the experimental results on direct selective laser sintering of WC-Co mixture for rapid tooling. The experiments were carried out within an air, argon and nitrogen atmosphere. Coupons of single layer were sintered at various laser powers, scanning speeds and scan spacings. As the energy density (energy per unit scanned area) is increased, the thickness of coupons is increased. The main problem took place during sintering within an air atmosphere was severe oxidation of WC-Co mixture. As the laser power is increased and/or scanning speed is decreased, more severe oxidation occurred. Within an argon and nitrogen atmosphere the oxidation is reduced significantly. Experiments on multi-layer sintering were also carried out.

  • PDF

A Study on Laser Welding of the Seat Back Frame Applied by High Strength Steels (고장력 강판을 적용한 Seat Back Frame의 레이저용접에 관한 연구)

  • Seol, Hyeon Uk;Jung, Byung Hun;Kim, Sok Won
    • Journal of Welding and Joining
    • /
    • v.35 no.3
    • /
    • pp.62-67
    • /
    • 2017
  • The automotive industry is in constant pursuit of alternative materials and processes to address the ever changing needs of their customers and the environment. Applications of laser welding have increased steadily in recent years due to its benefits including high speed, high productivity, and high energy density of heat source. This paper investigated the relationship between laser welding parameters and penetration characteristics. The Welding power was fixed at 5kW and welding speeds were varied for the thickness of the workpiece material. Full penetration occurred in the energy per unit area of $21J/mm^2$. The hardness of the weld zone was different for each strength of the workpiece material, however the lowest hardness values were the same in the heat-affected zone.

Experiments on Selective Laser Sintering of WC-Co Mixture for Rapid Metal Tooling (쾌속 금형 제작을 위한 텅스텐 카바이드와 코발트 혼합물의 선택적 레이저 소결 실험)

  • 김광희;조셉비만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.661-669
    • /
    • 2002
  • Rapid tooling technique enables us to make dies and molds that produce prototype parts with the correct material at a substantially reduced cost and time. In this study, experiments on selective laser sintering of tungsten carbide-cobalt mixture were carried out to find optimal sintering conditions that will be applied to rapid metal tooling. The experiments were carried out within an air, an argon and a nitrogen atmosphere. Coupons of single layer were sintered at various laser powers, scanning speeds and scan spacings. Very severe oxidation took place within an air atmosphere. The oxidation is reduced significantly within an argon and a nitrogen atmosphere. The thickness of the sintered coupons is increased as the energy density, the laser energy Per unit scanned area, is increased. Several multi-layer sintering experiments were also carried out.

Analysis of Long-term Thermal Performance of Solar Thermal System Connected to District Heating System (지역난방 적용 태양열시스템의 장기 열성능 분석)

  • Baek, Nam-Choon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.167-173
    • /
    • 2007
  • This study analyzed by simulation using TRNSYS as well as by experiment on the solar district heating system installed for the first time for the district heating system in Bundang. Simulation analysis using TRNSYS focused on the thermal behavior and long-term thermal efficiency of solar system. Experiment carried out for the reliability of simulation system. This solar system where the circuits of two different collectors, flat plate and vacuum tube collector, are connected in series by a collector heat exchanger, and the collection characteristics of each circuit varies. Therefore, these differences must be considered for the system's control. This system uses variable flow rate control in order to obtain always setting temperature of hot water by solar system. Specifically, this is a system that heats returning district heating water (DHW) at approximately $60^{\circ}C$ using a solar collector without a storage tank, up to the setting temperature of approximately $85{\sim}95^{\circ}C$ To realize this, a flat plate collector and a vacuum tube collector are used as separate collector loops. The first heating is performed by a flat plate collector loop and the second by a vacuum tube collector loop. In a gross collector area basis, the mean system efficiency, for 4 years, of a flat plate collector is 33.4% and a vacuum tube collector is 41.2%. The yearly total collection energy is 2,342GJ and really collection energy per unit area ($m^2$) is 1.92GJ and 2.37GJ respectively for the flat plate vacuum tube collector. This result is very important on the share of each collector area in this type of solar district heating system.

A Case study on the Improvement of Air Conditioning System for Thermal Comfort and Energy Conservation in a Middle-Sized Auditorium (사례연구를 통한 중규모 공연장의 공조시스템 개선 방안에 관한 연구)

  • Na, S.Y.;Rhee, E.K.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.85-96
    • /
    • 2002
  • Recently the number of auditoriums such as theaters, assembly halls, and concert halls is increasing in Korea. Auditoriums have generally large space volume, have a high density of occupancy per unit floor area, compared to other buildings. Since they have relatively high ceilings, some heat may stratify above the occupied zone. The under floor air conditioning system, which is set under seats, is frequently selected in an auditorium, because typical air conditioning system where air is supplied from ceilings often causes drafts and unequal temperature distribution. Therefore, this study aims to suggest basic data for air conditioning system design of a middle-sized auditorium. Features and problems of air conditioning system of an auditorium which has about 500 seats are investigated as a case study. In addition, indoor thermal comfort and cooling energy consumption are analyzed with a CFD program and an energy analysis program.

Application of Electrochemical Method for Decolorization of Biologically Treated Animal Wastewater Effluent (생물학적 축산폐수 처리수 색도제거를 위한 전기화학적 방법의 적용)

  • 윤성준;신종서;라창식
    • Journal of Animal Science and Technology
    • /
    • v.48 no.2
    • /
    • pp.315-324
    • /
    • 2006
  • This research was conducted to clarify the characteristics of electrochemical decolorization of effluent discharged from a biological animal wastewater treatment process and to finally establish parameters or mode for optimum operation of electrolysis system. Average color unit of wastewater was about 1,200 and DSA(Dimensionally Stable Anode) was used as electrode. Experiments were performed with two different operation conditions or modes, fixed voltage-free current(Run A) and free voltage-fixed current(Run B). Color removal rate was proportional to the electrode area and electrical conductivity, and an equation subject to them at a condition of fixed voltage was derived as follows; Ct=C0ekt, k=[{0.0121×a(dm2)× c(mS/cm)}+0.0288], [where, C0: initial color, Ct: color unit after treatment for t, k: reaction coefficient, t: time(min.), a: electrode area, c: conductivity]. From the study on the effects of current density on color removal, it was revealed that the removal efficiency of color was function of the current density, showing direct proportion. However, when considered energy consumption rate, maintenance of low current density was an economical way. Based on the obtained results, it was concluded that supplementation of electrolyte is not necessary for the removal of color from the effluent of secondary treatment process and operation with the mode of free voltage-fixed current, rather than operation with fixed voltage-free current mode, would be an efficient way to increase the removal performance and capacity per consumed energy.