• 제목/요약/키워드: Energy per unit area

검색결과 173건 처리시간 0.026초

소다석회유리의 CO2 레이저 스크라이빙 가공 (CO2 Laser Scribing Process of Soda Lime Glass)

  • 강승구;신중한
    • 한국기계가공학회지
    • /
    • 제18권5호
    • /
    • pp.74-81
    • /
    • 2019
  • This study reports the CW $CO_2$ laser scribing of soda lime glass. In this study, scribing experiments are carried out at different laser powers, scan speeds, and focal positions to investigate the effect of the process parameters on the interaction characteristics between a laser beam and glass. In particular, the interaction characteristics are analyzed and described with the input laser energy per unit length. According to the experimental results, the damage threshold for the glass surface was found to exist between 0.072 and 0.08 J/mm. The input laser energy in this region induced partial melting of the surface and grain-shaped cracks. These cracks tended to increase as the input laser energy increased. At the laser input energy larger than 1 J/mm, a huge crack propagating along the scan direction was produced, and the volume below the scribed area was fully melted. The growth of this crack finally resulted in the complete cutting of the glass at the input laser energy above 8 J/mm. It was found that both the width and depth of the scribed line increased with increasing input laser energy. For the beam focusing at the rear surface, the width of the scribed line varied irregularly. This could be ascribed to the increased asymmetry of the beam intensity distribution when the laser beam was focused at the rear surface. Under this condition, a large burr was only produced on one side of the scribed line.

도심 임대아파트의 에너지 및 상수 소비 특성에 관한 연구 (An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental Apartment)

  • 서윤규;김주영;홍원화
    • 한국주거학회논문집
    • /
    • 제20권6호
    • /
    • pp.39-46
    • /
    • 2009
  • It has been a serious problem to consume the energy of apartment while increasing to use of heating & cooling System because of residence environmental upgrades. Great attention has been shown to the problem of the rental apartment, so there are few reports of energy consumption about the rental apartment in korea. To solve the lack of housing, our country has supplied an enormous volume of apartments, and these days it occupies 75% of our buildings. As apartments occupy most of our housings, the rate of energy usage from them are also high. On this, setting apartment energy reduction as a target, by researching the actual conditions of energy consumption and drawing a basis data, we can apply this as a way of saving energy, rationalization of the scale of energy supply facilities and a standard when planning facilities. To grasp the present condition of energy usage of the urban rental apartment, this research analysed the use of electricity, gas and water monthly and annually of a rental apartment that is located in Daegu. The results showed that in 2003 the electricity usage was 1,198MWh but 1,315MWh in 2007, which means 9% of electricity usage increases every year. The average of water usage was $85,072\;m^2$ per year and typical energy consumption unit was $604.2\;MJ/m^2$ on $74.4\;m^2$ of area and $448.8\;MJ/m^2$ on $105.8\;M^2$. By showing the usage of energy and water of the urban rental apartment, understanding the tendency and preparing an typical energy consumption unit standard through this research, apartments should use energy more efficiently.

도시 내 지역난방 Heat Pump용 잠재열원 이용에 관한 연구 (A Study on the Utilization of potential heat sources for Heat Pumps to District Heating System in Urban)

  • 오광민;김래현
    • Korean Chemical Engineering Research
    • /
    • 제56권6호
    • /
    • pp.841-855
    • /
    • 2018
  • 본 연구는 도시 내 지역난방 공급지역에 존재하는 Heat Pump용 가용 잠재적 열원을 추정하고자 하였다. 미활용에너지 잠재량은 Open source 기반의 자료를 바탕으로 추정 통합하였다. 특히 수도권 남부에 위치한( 평택시) DH network 내에 대형마트와 공공사우나 시설에 대해 회수 가능한 열에너지 밀도와 열원 지역의 열 수요에 대해 지리적인 공간 분석을 수행하였다. 연구 결과, 연구 대상 DH network 지역에서는 대형마트와 공공사우나 두 가지 열원에 대해 총 1,741.7 toe/year 수준의 잠재 에너지량을 보유하고 있었다. 이 중 57.8%에 해당하는 1,006.9 toe/year를 지역난방용으로 연계할 수 있을 것으로 추정 되었다. 대형마트는 연면적과 에너지 사용량이 0.4937의 양의 상관관계를 보였다. 회수 가능한 에너지 원단위는 상관관계계수를 반영하여 연면적 당 $0.0017toe/m^2$, 저감 가능한 온실가스 배출량은 $0.0069tCO_2/m^2$로 분석되었다. 또한, 공공사우나는 실증사례와 이론 계산 값을 비교하여, 80% 수준의 보수적 추정으로 목욕장 면적당 $0.0315toe/m^2$가 회수 가능한 에너지 원단위로 분석되었으며, 저감 가능한 온실가스 배출량은 $0.1183tCO_2/m^2$로 분석되었다. 이 지역의 총 잠재 에너지량은 행정 구역별 공동주택의 열 수요와 0.5272의 양의 상관관계를 갖고 있었으며, 특히 교통과 상업 중심 지구에서 상대적으로 높은 잠재 에너지량을 가지고 있음을 확인 하였다.

대학 내 에너지 소비에 따른 온실가스-대기오염 통합 인벤토리 및 대체 에너지 사용 시나리오 분석 (A Study of GHG-AP Integrated Inventories and Alternative Energy Use Scenario of Energy Consumption in the University)

  • 정재형;권오열
    • 한국환경과학회지
    • /
    • 제23권9호
    • /
    • pp.1643-1654
    • /
    • 2014
  • The university is one of the main energy consumption facilities and thereby releases a large amount of greenhouse gas (GHG). Accordingly, efforts for reducing energy consumption and GHG have been established in many local as well as international universities. However, it has been limited to energy consumption and GHG, and has not included air pollution (AP). Therefore, we estimated GHG and AP integrated emissions from the energy consumed by Seoul National University of Science and Technology during the years between 2010 and 2012. In addition, the effect of alternative energy use scenario was analysed. We estimated GHG using IPCC guideline and Guidelines for Local Government Greenhouse Inventories, and AP using APEMEP/EEA Emission Inventory Guidebook 2013 and Air Pollutants Calculation Manual. The estimated annual average GHG emission was $11,420tonCO_{2eq}$, of which 27% was direct emissions from fuel combustion sectors, including stationary and mobile source, and the remaining 73% was indirect emissions from purchased electricity and purchased water supply. The estimated annual average AP emission was 7,757 kgAP, of which the total amount was from direct emissions only. The annual GHG emissions from city gas and purchased electricity usage per unit area ($m^2$) of the university buildings were estimated as $15.4kgCO_{2eq}/m^2$ and $42.4tonCO_{2eq}/m^2$ and those per person enrolled in the university were $210kgCO_{2eq}$/capita and $577kgCO_{2eq}$/capita. Alternative energy use scenarios revealed that the use of all alternative energy sources including solar energy, electric car and rain water reuse applicable to the university could reduce as much as 9.4% of the annual GHG and 34% of AP integrated emissions, saving approximately 400 million won per year, corresponding to 14% of the university energy budget.

세계 기후대별 High-Performance Buildings의 에너지 소비 원단위 평가 및 신기술 적용 동향 분석 연구 (Comprehensive Analysis of Energy Consumption Rate and New Technology Trend in High-Performance Buildings related with Different Climatic Zones)

  • 김철호;이승언;김강수
    • 대한건축학회논문집:구조계
    • /
    • 제34권11호
    • /
    • pp.63-72
    • /
    • 2018
  • In this study, we analyzed high-performance building technologies through a case study of 65 high-performance buildings in the U.S., Europe, Asia and Oceania. In detail, we reviewed the international trend of building energy-saving technology and energy consumption per unit area by analyzing buildings constructed within a 10 year period(2008-018). The primary energy consumption was $48-440kWh/m^2$, and the average value was calculated as $169.3kWh/m^2$. Although some buildings received high certification ratings, they did not meet either Korean or international energy evaluation standards. The system analysis revealed that many energy-saving technologies show various application rates in different countries because the technologies possess different properties. Furthermore, small-area building groups tended to have less primary energy consumption than the medium and large-area buildings, but the area-energy relationship $R^2$ value was analyzed as 0.3161, indicating no clear proportional relationship. Therefore, we propose that it is necessary to maximize the energy savings of buildings by taking into consideration a region's code, climate, building usage, area and space-using patterns to reduce energy and greenhouse gas emissions.

PV모듈의 냉각장치를 적용한 집속형 복합패널의 집열 특성 평가 (Thermal Characteristics Evaluation of Concentrated Hybrid Panel with cooling system on PV module)

  • 서유진;허창수
    • 한국태양에너지학회 논문집
    • /
    • 제25권3호
    • /
    • pp.47-52
    • /
    • 2005
  • Normally if sunlight is directed on a solar cell without any increasing in temperature, the amount of absorption energy per unit area of each cell is increasing. In a silicon solar cell. however, cell conversion efficiency decreases with the increase of temperature. Therefore, to maintain cell conversion efficiency under normal condition, it is necessary to keep the cell at operating temperature. We tried to design and make new hybrid panel with cooling system to prevent increasing of temperature on cell, collect and use thermal energy more effectively. We compared performance of this new hybrid panel with current thermal panel. We also evaluated conversion efficiency, thermal capacity and confirmed cooling effects from thermal absorption efficiency.

순간전압강하 가혹지역에 기반한 사고예방 대책 수립 (Establishment of Preventive Measures against Faults Based on the Area of Severity to Voltage Sags)

  • 박창현;이계병;이한상;윤동희
    • 전기학회논문지
    • /
    • 제64권11호
    • /
    • pp.1611-1617
    • /
    • 2015
  • This paper presents an effective approach for establishing countermeasures against voltage sags based on the concept of area of severity. In order to apply preventive measures against faults such as lightning arrester, overhead earth wires and so on, it is important to find optimal points for installing the preventive measures. The optimal points can be determined by the calculation of the area of severity(AOS) to voltage sags and the expected sag frequency per unit length of line. In this paper, an effective method to find optimal points to apply countermeasures against voltage sags is addressed with case studies.

산림전용에 따른 폐잔목의 임산바이오에너지 잠재적 공급량 분석 (Biomass Energy Potential of Wood Waste due to Forest Land Conversion)

  • 권순덕;손영모;박영규
    • 임산에너지
    • /
    • 제25권2호
    • /
    • pp.16-21
    • /
    • 2006
  • 본 연구의 목적은 산림전용에 따라 발생되는 폐잔목의 임산바이오에너지 이용 가능량을 분석하기 위한 것이다. 최근 5년간(2001-2005) 연평균 약 7,806ha의 산림이 타용도로 전용되고 있으며, 이로 인해 연평균 $266,551m^3$의 입목이 벌채되었다. 산림전용에 따른 폐잔목의 임산바이오에너지 이용가능량(바이오매스)을 분석한 결과, 지난 5년간 침엽수림의 경우 연평균 약 57,945ton, 활엽수림은 44,379ton으로 나타나, 우리나라에서 전체적으로 연간 102,325ton을 이용할 수 있는 것으로 분석되었다. 산림전용시 발생하는 단위면적당 이용 가능한 임산바이오에너지량은 매년 증가추세를 보였으며, 지난 5년간 연평균 발생량은 약 13.0ton/ha으로 나타났다.

  • PDF

Nd : YAG laser 조사가 치근면 상아세관의 노출에 미치는 효과에 관한 주사전자현미경적 연구 (THE EFFECT OF ND : YAG LASER IRRADIATION ON EXPOSURE OF THE DENTINAL TUBULES ON ROOT SURFACE IN EXTRACTED HUMAN TEETH;A SCANNING ELECTRON MICROSCOPIC STUDY)

  • 조종희;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제23권3호
    • /
    • pp.564-576
    • /
    • 1993
  • The purpose of this study was to evaluate the effects of Nd:YAG laser treatment on removal of smear layer and exposure of dentinal tubules. The experimental specimens were obtained from root planed surface of 30 human teeth which were extracted due to severe periodontal disease. The specimens were assigned randomly of three groups: root planed group, Tetracycline HCl(100mg/ml, 5min) group, and Nd:YAG laser ($Laser-35^{TM}$, U.S.A. 5 seconds )group. Nd:YAG laser group was divided into 4 subgroups according to 3.0W, 3.5W, 4.0W, 4.5W of power. The surface change of specimens were evaluated by scanning electron microscopy. The number of exposed dentinal tubules and percentage of area occupied by dentinal tubule orifices per unit area between each group was statistically analyzed by paired Student t-test. The results were as follows: 1. By root planing only, dentinal tubule was not exposed, but scale-like smear layer and parallel instrument tracks were resulted. 2. Tetracycline HCl treated surfaces exhibited the small number of partially exposed dentinal tubules with long orifices. The number($3.80{\pm}0.79$) of exposed dentinal tubules on Tetracycline HCl group was significantly less than that in laser groups above 3.5W of power(P<0.001), and the percentage ($0.68{\pm}0.19$) of area occufied by dentinal tubule orifices per unit area($192\;{\mu}m^2$) was significantly lower than that of any laser group(P<0.001). 3. The laser group irradiated with 4.5W of power showed both the most number($10.60{\pm}0.97$) of exposed dentinal tubules among the experimental groups, and the highest percentage($3.75{\pm}0.55\;%$) of area occupied by dentinal tubule orifices. 4. Energy Surge during laser pulsing and overlapping passes of the fiber resulted in melted and resolidified surface textures with lava-like appearance.

  • PDF

Heat Transfer Performance of Plate Type Absorber with Surfactant

  • Yoon, Jung-In;M. M. A. Sarker;Moon, Choon-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.243-251
    • /
    • 2004
  • Absorption chiller/heater can utilize the unused energy of the daily life waste heat, the industry waste heat. the solar energy and the earth energy. These can contribute to energy savings. But the absorption chiller/heater has a demerit that the size of absorption chiller/heater is larger than that of the vapor compression type based on same capacity. In this study. the experimental apparatus of an absorber is manufactured as a plate. which is newly applied in an absorber. The experimental apparatus is composed of a plate type absorber. which can increase the heat exchange area per unit volume and thus facilitating to deeply investigate more detail features instead of that done by the existing type. i.e.. horizontal tube bundle type. The characteristics of heat transfer and refrigeration capacity are studied experimentally. The absorption enhancement by using surfactant is closely examined through the experiment and comparative figures are presented in quantitative and qualitative analysis.