• Title/Summary/Keyword: Energy margin

Search Result 282, Processing Time 0.025 seconds

Enhancement of critical heat flux with additive-manufactured heat-transfer surface

  • Tatsuya Kano;Rintaro Ono;Masahiro Furuya
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2474-2479
    • /
    • 2024
  • In-Vessel Retention (IVR) is a key technology to retain the molten core in the reactor vessel during severe accidents of Pressurized-water reactors (PWRs). In order to gain the safety margin of IVR, it is crucial to enhance the critical heat flux (CHF) of the reactor vessel, which is submerged in a water pool. To enhance the CHF, we have designed and additive-manufactured porous grid plates with a 3-D printer for design flexibility. We measured the CHF for the porous grid plate on the boiling heat transfer surface and found that the CHF was enhanced by 50 % more than that of the bare surface. The CHF enhanced more with a narrower grid pitch and a lower grid height. The visual observation study revealed that the vapor film was formed at the bottom of the grid plate.

Stability and Performance Investigations of Model Predictive Controlled Active-Front-End (AFE) Rectifiers for Energy Storage Systems

  • Akter, Md. Parvez;Mekhilef, Saad;Tan, Nadia Mei Lin;Akagi, Hirofumi
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.202-215
    • /
    • 2015
  • This paper investigates the stability and performance of model predictive controlled active-front-end (AFE) rectifiers for energy storage systems, which has been increasingly applied in power distribution sectors and in renewable energy sources to ensure an uninterruptable power supply. The model predictive control (MPC) algorithm utilizes the discrete behavior of power converters to determine appropriate switching states by defining a cost function. The stability of the MPC algorithm is analyzed with the discrete z-domain response and the nonlinear simulation model. The results confirms that the control method of the active-front-end (AFE) rectifier is stable, and that is operates with an infinite gain margin and a very fast dynamic response. Moreover, the performance of the MPC controlled AFE rectifier is verified with a 3.0 kW experimental system. This shows that the MPC controlled AFE rectifier operates with a unity power factor, an acceptable THD (4.0 %) level for the input current and a very low DC voltage ripple. Finally, an efficiency comparison is performed between the MPC and the VOC-based PWM controllers for AFE rectifiers. This comparison demonstrates the effectiveness of the MPC controller.

A New Stabilizing Method for Transiently Unstable Systems by Using Transient Energy Function (에너지함수를 이용한 과도불안정 시스템의 안정화 방법)

  • Kim, Jung-Woo;Chun, Yeong-Han
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.567-575
    • /
    • 2008
  • Transient security assessment(TSA) is becoming an essential requirement not only for security monitoring but also for stabilizing control of power systems under new electricity environments. It has already been pointed out that fast transient stability study is an important part for monitoring and controlling system security. In this paper, we discuss an energy function method for stabilizing control of transiently unstable systems by introducing generator tripping system to enhance the transient stability of power systems. The stabilization with less tripped power can be obtained by tripping the generators faster than out-of-synchronism relay. Fast transient stability assessment based on the state estimation and direct transient energy function method is an important part of the stabilizing scheme. It is possible to stabilize the transiently unstable system by tripping less generators before the action of out-of-synchronism relay, especially when a group of generator are going to be out-of-synchronism. Moreover, the amount of generator output needed for tripping can be decided by Transient Energy Function(TEF) method. The main contribution of this paper is on the stabilizing scheme which can be running in the Wide Area Control System.

An Analysis of the Prediction Accuracy of HVAC Fan Energy Consumption According to Artificial Neural Network Variables (인공신경망 변수에 따른 HVAC 에너지 소비량 예측 정확도 평가 - 송풍기를 중심으로-)

  • Kim, Jee-Heon;Seong, Nam-Chul;Choi, Won-Chang;Choi, Ki-Bong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.73-79
    • /
    • 2018
  • In this study, for the prediction of energy consumption in the ventilator, one of the components of the air conditioning system, the predicted results were analyzed and accurate by the change in the number of neurons and inputs. The input variables of the prediction model for the energy volume of the fan were the supply air flow rate, the exhaust air flow rate, and the output value was the energy consumption of the fan. A predictive model has been developed to study with the Levenbarg-Marquardt algorithm through 8760 sets of one-minute resolution. Comparison of actual energy use and forecast results showed a margin of error of less than 1% in all cases and utilization time of less than 3% with very high predictability. MBE was distributed with a learning period of 1.7% to 2.95% and a service period of 2.26% to 4.48% respectively, and the distribution rate of ${\pm}10%$ indicated by ASHRAE Guidelines 14 was high.8.

Analysis of the Impact of Occupational Accidents on the Management Performance of Energy Companies (산업재해가 에너지 기업의 경영성과에 미치는 영향 분석)

  • Sunyoung Park
    • Environmental and Resource Economics Review
    • /
    • v.31 no.4
    • /
    • pp.693-710
    • /
    • 2022
  • Social interest in occupational safety and health is increasing due to ESG management and the implementation of the Serious Accidents Punishment Act. This study examines the current status of occupational accidents, which is the safety level of energy companies, and the impact of occupational accidents on the management performance (sales per capita, operating profit per capita, operating margin per capita) of energy companies over the period of 2015 to 2021 was empirically analyzed. As a result of the analysis, the level of occupational accidents in the 157 energy companies to be analyzed was lower than the occupational injury accident rate in Korea, but the disease rate was high.As a result of analyzing the impact of occupational accidents on management performance, it is estimated that an increase in the occupational accident rate reduces per capita sales, per capita operating profit, and gross margin rate.Through this study, the vulnerability of energy companies to occupational accidents was confirmed, and the direct and indirect costs of occupational accidents quantified the negative impact on management performance.Referring to the results of this study, energy companies should strengthen their efforts to prevent occupational accidents by increasing investment in safety and health to protect the lives of valuable workers and create sustainable business performance.

Economical run strategy for Korea High Speed Train Prototype (한국형 고속전철 경제운전 전략)

  • Lee Tae-Hyung;Park Choon-Soo
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1381-1385
    • /
    • 2004
  • This paper presents a modelling methodology using fuzzy logic and train performance simulation for determining an economical running pattern for a high speed train which minimizes energy consumption under an given trip margin. The economical running pattern is defined with an economical maximum speed in traction phase, a speed at the end of coasting. As a case study, the simulation is carried out for an economical run of korea high speed train prototype, and the results of fuzzy model described.

  • PDF

PYROPROCESS WASTE DISPOSAL SYSTEM DESIGN AND DOSE CALCULATION

  • Kook, Dong-Hak;Cho, Dong-Keun;Lee, Min-Soo;Lee, Jong-Youl;Choi, Heui-Joo;Kim, Yong-Soo
    • Nuclear Engineering and Technology
    • /
    • v.44 no.5
    • /
    • pp.483-490
    • /
    • 2012
  • PWR spent fuels produced in the Republic of Korea are expected to be recycled by pyroprocess in the long term future. Even though pyroprocess waste amounts can be smaller than that of PWR spent fuel assembly in case of direct disposal, this process essentially will produce various and unique radioactive wastes. The goals of this article are to characterize these wastes, calculate the amount of wastes, design disposal systems for each waste and evaluate the radiation safety of each system by dose assessment. The absorbed dose results of the metal and ceramic waste for the engineering barrier system (EBS) showed $2.21{\times}10^{-2}$ Gy/h and $1.15{\times}10^{-2}$ Gy/h, which are lower than the recommended value of 1 Gy/h. These results confirmed that the newly proposed disposal systems have a safety margin for the radiation produced from each waste.

A Study on the Effects of Position Change on the Liver Shape on Radioisotope Scan (간(肝)스캔상(上) 체위변동(體位變動)에 따른 간형태(肝形態) 변화(變化)에 대(對)한 고찰(考察))

  • Hong, Kee-Suk;Choi, Du-Hyok;Yang, Young-Tae;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.1
    • /
    • pp.49-54
    • /
    • 1982
  • For this study, the authors obtained and examined anterior views of the liver and spleen in two different positions, upright and supine, of 39 normal subjects and 20 patients with hepaticpathology by means of $^{99m}Tc-colloid$ and gamma camera. This examination confirms the following findings. In general, it is shown, left lobe of the liver in upright position becomes longer in height than in supine position, while the distance between lateral margin of the liver and that of the spleen becomes father in with in supine position than in upright position. The upper margin of liver moves more downward in upright position than in supine. It is noticeable that as for 5 cases with severe chronic liver disease, there is minimal alteration of the liver shape between in two positions. The comparison of the both positions for the better liver scan shows the following finding. Prominent caudate and/or left lobe are marked in the upright position in 16 cases out of the total 59, while none is found in the supine. The false cold area in lower part of the liver disappears in 7 cases in the upright position, while only one shows the disappeance of the false cold area in the supine. Left liver margin due to close contact of spleen is blurred in 3 cases in the upright position. In total 23 cases out of 59 support that the upright position is better for the liver scan, while only 4 cases support the supine position is better. These findings support two assumptions. One is that upright view can bo expected more improved resoluton than supine view for liver scan. Second is that minimal change of the liver shape in both views indicate the serious abnormality in the liver.

  • PDF

Influences of degradation in MgO protective layer and phosphors on ion-induced secondary electron emission coefficient and static margins in alternating current plasma display panels

  • Jeong, H.S.;Lim, J.E.;Park, W.B.;Jung, K.B.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.518-521
    • /
    • 2004
  • The degradation characteristics of MgO protective layer and phosphors have been investigated in terms of the ion-induced secondary electron emission coefficient ${\gamma}$ and static margin of discharge voltages, respectively, in this experiment. The ion-induced secondary electron emission coefficients ${\gamma}$ for the degraded MgO protective layer and phosphors have been studied by ${\gamma}$ -focused ion beam system. The energy of Ne+ ions used is from 80 eV to 200 eV in this experiment. The degraded MgO and phosphor layers are found to have higher ${\gamma}$ than that of normal ones without degradations or aged one. Also, the static margin of discharge voltages for test panels with degraded MgO protective layer and phosphors been found to be seriously decreased in comparison with those of normal ones without degradations.

  • PDF