• Title/Summary/Keyword: Energy management plan

Search Result 310, Processing Time 0.032 seconds

Sustainable energy action plans of medium-sized municipalities in north Greece

  • Lymperopoulos, Konstantinos A.;Botsaris, Pantelis N.;Angelakoglou, Komninos;Gaidajis, Georgios
    • Advances in Energy Research
    • /
    • v.3 no.1
    • /
    • pp.11-30
    • /
    • 2015
  • The covenant of Mayors initiative includes the commitment of the municipalities-signatories to reduce voluntarily the greenhouse gas emissions over 20--- by 2020 within their boundaries and obligates them to develop and submit an energy consumption analysis and a sustainable energy action plan within a year from the adhesion. The present paper discusses the energy profile of three medium-sized north-eastern Greek Municipalities (Kavala-MoK, Alexandroupolis-MoA, Drama-MoD) through the analysis of their municipal energy balance. The results of the total final energy consumption per capita include 14.10MWh/capita, 14.24MWh/capita and 12.91MWh/capita for MoK, MoA and MoD respectively. The analysis highlighted the increased energy consumption of the private sectors, namely residential and tertiary building sand private transport. The assessment of the municipalities' energy profiles along with examination of national regulations and action plans and investigation of best available practices within the Covenant of Mayors shaped the development of the sustainable energy action plans of the examined municipalities that is presented in this paper. The proposed pathway towards low-carbon municipalities can be considered a representative case study and a starting point for other municipalities with similar characteristics.

Energy Efficiency Evaluation of IT based Ship Energy Saving System-(1) : Ship Handling Simulator Test Results (IT 기반의 선박에너지절감시스템 성능평가 방법-(1) : 육상시험 수행 결과)

  • Yoo, Yun-Ja
    • Journal of Navigation and Port Research
    • /
    • v.39 no.6
    • /
    • pp.465-472
    • /
    • 2015
  • SEEMP (Ship Energy Efficiency Management Plan) guidelines for a ship's GHG reduction include a machinery modification of hull, an installation of energy efficiency enhanced attachment in hardware methods. It is also possible to bring a ship energy efficiency improvement by fuel-efficient operations or in other software methods. Hardware modification or installation on ship can bring financial burdens to a ship company compared to its improvement expectation. On the other hand, Software based energy-saving technology can be applicable on various ship types, and it is also expected high efficiency of ship energy use compared to hardware based technology in perspective of the investment costs and efficiency. In this paper, it is described that the ship handling simulator based evaluation was carried out using representative ship model of bulk, container and VLCC. Simulation environments were separated into 6 conditions according to the sea-state and weather condition, and the operation results were compared with those before and after energy saving system applied The container ship showed the largest FOC save rate after energy saving system applied although the others also showed energy save rate after using the system.

Operating Budget Management Plan on Electric Energy Consumption of Educational Facilities (교육시설물의 전기에너지 사용량에 따른 운영예산 관리방안)

  • Wang, Ji-Hwan;Jin, Chengquan;Lee, Sanghoon;Hyun, Chang-Taek
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.4
    • /
    • pp.26-35
    • /
    • 2022
  • The 7th education reform in 1997 has led changes in the way buildings were constructed and such changes drove educational facilities to steadily consume more energy every year. Also, these facilities take several years' estimated expenditure as well as the increased unit price of electricity into account when planning their annual operating budget. Such circumstances may adversely affect the establishment of their budget plan since improper allocation of operating costs could take place. To propose educational facilities' operating budget management plan on electrical energy consumption, this study developed a model that help oversee the facilities' consumption of electrical energy. For the model development, the primary core variables related to electrical energy factors from the aspects of surroundings, physics, policy, etc. were derived from taking both literature research and the characteristics of these facilities into account. The secondary core variables were then derived using the correlation analysis. Lastly, the electric energy use prediction model was developed by performing regression analysis based on the derived secondary core variables.

The Study on Program for Happy House Sanjeon District Center in Jung-gu, Ulsan City (해피하우스지역센터 프로그램에 관한 연구)

  • Kim, Sun-Joong
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2011.04a
    • /
    • pp.161-166
    • /
    • 2011
  • This research was conducted in order to suggestion management program of Happy house center which facility of detached housings, multi family housing, and semi-detached housing management. This study's purpose is to systematically help create a district customized co-management housing management system among detached housing area by reflecting resident opinion and simultaneously provide basic research. The area of research is Sanjoen district in Ulsan city that compact old detached houses. The research study's results are follows: First, the overall survey results showed that most respondents demanded program of happy house center for housing energy deduction method and support of house insulation cost and heating fuel cost. Second, happy house center try to order of priority or housing maintenance and seek of cost deduction plan. Third, happy house center propose the Maeulmandeulgi(Machizkuri) program or housing management plan for residents' talent contribution.

  • PDF

스마트 그리드에 그린 IT 활용 연구

  • Jeong, Hyeon-Su;Kim, Byeong-Sik;Wang, Mi-Gyeong;Kim, Jong-Hun;Han, Myeong-Ji
    • Proceedings of the Korea Database Society Conference
    • /
    • 2010.06a
    • /
    • pp.33-41
    • /
    • 2010
  • Recently the number of IT equipment have increased. It consumes large amounts of energy and is emissions of greenhouse gases. Co2 emissions with the PC and the monitor has the highest percentage to 39% more than other IT equipment. In addition, Plan for your PC's power management and technology development is being pursued in developed countries. To reduce energy costs of organizations with large numbers of the PC and to cut down on Co2 emissions, the energy load control technology of ACPI standards-based PC IS suggested. AMI-based PC power-management system was constructed, Approximately 20% of operating a result of the test power consumption was reduced. Looking at the case of the United States, PC monitors from the University of Wisconsin-Oshkosh was Sleep mode. As a result, the monitor on a, $ 20 for a year reduced energy costs. In GE(General Electronic), Approximately 75,000 PC's power setting time was Monitor Off :15 minutes/ Hard Drives Off 30 minutes/ System Standby 30 minutes/ Hibernation mode 2 hours. 1 year, electric bill was $ 2.5 million savings and 3 years electric bill was $ 6.5 million savings. Measuring energy usage data, using the measured data, electric energy management technology is not. Platform development to measure energy usage for Individual energy-consuming equipment is urgently required.

  • PDF

Multi-Objective Optimal Predictive Energy Management Control of Grid-Connected Residential Wind-PV-FC-Battery Powered Charging Station for Plug-in Electric Vehicle

  • El-naggar, Mohammed Fathy;Elgammal, Adel Abdelaziz Abdelghany
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.742-751
    • /
    • 2018
  • Electric vehicles (EV) are emerging as the future transportation vehicle reflecting their potential safe environmental advantages. Vehicle to Grid (V2G) system describes the hybrid system in which the EV can communicate with the utility grid and the energy flows with insignificant effect between the utility grid and the EV. The paper presents an optimal power control and energy management strategy for Plug-In Electric Vehicle (PEV) charging stations using Wind-PV-FC-Battery renewable energy sources. The energy management optimization is structured and solved using Multi-Objective Particle Swarm Optimization (MOPSO) to determine and distribute at each time step the charging power among all accessible vehicles. The Model-Based Predictive (MPC) control strategy is used to plan PEV charging energy to increase the utilization of the wind, the FC and solar energy, decrease power taken from the power grid, and fulfil the charging power requirement of all vehicles. Desired features for EV battery chargers such as the near unity power factor with negligible harmonics for the ac source, well-regulated charging current for the battery, maximum output power, high efficiency, and high reliability are fully confirmed by the proposed solution.

Stepwise Technique for Improving Building Energy Efficiency Rating Utilizing Quantified Simulation Model (정량화 시뮬레이션 모델을 활용한 단계적인 건축물에너지효율등급 향상 방안)

  • Kim, Gi-Seok;Kim, You-Min;Kim, Jong-Seung;Oh, Se-Gyu
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.65-73
    • /
    • 2014
  • Due to the Climate change and resource shortage by global warming, various problems are rising and getting worse around the world. Many countries are doing the considerable efforts to reduce greenhouse gas emissions. The government of South Korea also plans to decrease greenhouse gas emission, the various pilot projects are underway, which includes obligation of energy efficiency 1st rating and greenhouse gas target management system of public buildings. In particular, luxurious government office buildings and energy-wasting public building have issued and emerged as a social problem. Energy efficiency improvement of the existing public office buildings are becoming an important issue recently. This study is proposed the step-by-step energy improvement model according to the building energy efficiency rate in order to reduce the energy consumption. To attain this end, I set up a base model by analyzing the current architectural conditions of the existing public office buildings and grasped the specific properties of building energy consumption through energy simulations. Furthermore, I suggested phased reduction prototypes for the reduction target of energy consumption by applying the methods of the zero energy building plan. This study is expecting that prototypes would give directions when it comes to planning the implementation policy of phased building plan factors, according the building energy consumption reduction goal in the existing public office buildings which are the subject of building energy target management system.

Design and Verification of Advanced Distribution Management System using Information and Communication Convergence Technology (ICT융복합 기술을 이용한 차세대 배전계통 운영 시스템 설계 및 검증)

  • Kim, Dongwook;Park, Youngbae;Chu, Cheolmin;Jo, Sungho;Seo, Inyong
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.15 no.4
    • /
    • pp.19-29
    • /
    • 2019
  • Recently, with the rise of environmental issues and the change of government policy (Renewable Energy 3020 Implementation Plan), a large amount of renewable energy such as solar and wind power is connected to the power system, and most of the renewable energy is concentrated in the power distribution network. This causes many problems with the voltage management and the protection coordination of the grid due to the its intermittent power generation. In order to effectively operate the distribution network, it is necessary to deploy more intelligent terminal devices in the field to measure the status of the distribution network and develop various operation functions such as visualization and big data analysis to support the power distribution system operators. In addition, the failover technology must be supported for the non-stop operation of the power distribution system. This paper proposes the system architecture of new power distribution management system to cope with high penetration of renewable energy. To verify the proposed system architecture, the functional unit test and performance measurement were performed.

Study of photon beam quality tool at magnetic field change in bending magnet (편향전자석의 자장변화에 따른 광자선 선질평가에 관한 고찰)

  • Kim, Jeong-Ho;Yoo, Se-Jong;Park, Myeong-Cheol;Bae, Seok-Hwan;Kim, Ki-Jin
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.433-439
    • /
    • 2014
  • Beam quality is changed about magnetic field of bending magnet. Evaluation of beam quality using PDD(Percentage Depth Dose) at 10cm depth at recommendation of AAPM(America Academy of Pain Medicine). However this evaluation shows fragmentary element. Therefore this study is applied to three value, 10cm divided by 5cm depth PDD, 20cm divided by 10cm depth PDD, 30cm divided by 20cm depth PDD, at change the magnetic field. PDD is measured at magnetic field changed ${\pm}1%$, ${\pm}2%$ at 6MV(Mega Voltage), 10MV photon. The plan technique is 3 portal plan using Core-Plan at human pelvic phantom. Conventional and presented methods are compared at maximum and minimum dose. The presented method increased discernment of relieve the unequal distribution and energy area than conventional method. Henceforth, application of presented method will be considered. Development of energy measurement method and detector miniaturization will be needed about continuous study.

Strategies for Advancement of response management system on marine pollution (해양오염 방제체제의 선진화 방안)

  • Kim Dae Won
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.1
    • /
    • pp.3-24
    • /
    • 2000
  • The provability of major oil spill acidents around Korean coast is very high due to increase of sea traffic and decrease of quality of ships crews and increase of the old-ship. The Strategies of establishment of a advanced response management system against this mass pollution incident are as follows;. 1. Development of Regional Contingency Plan, which is scientifically illuminated, in order to implement the National Contingency Plan efficiently. 2. Early completion of a national response capability twenty thousand tons. 3. To strengthen training and exorcise specialized in the field of marine pollution response. 4. Establishment of a system of response cooperation among neighbor countries by promoting the NOWPAP tasks etc. The response policy in the 21th century should be concentrated to promote a practicle response capability through response operation scientifically specialized and internationalized by establishing the advanced response system early.

  • PDF