• Title/Summary/Keyword: Energy losses

Search Result 708, Processing Time 0.025 seconds

An Analysis of Heat Losses from Receivers for a Multifaceted Parabolic Solar Collector (접시형 태양열 집광시스템용 흡수기의 열손실 해석)

  • Ryu, S.Y.;Seo, T.B.;Kang, Y.H.
    • Solar Energy
    • /
    • v.20 no.3
    • /
    • pp.61-73
    • /
    • 2000
  • Heat losses from receivers for a dish-type solar energy collecting system are numerically investigated. The analytical method for predicting conductive heat loss from a cavity receiver is used. The Stine and McDonald Model is used to estimate convective heat loss. Two kinds of techniques for the radiation analysis are used. The Net Radiation Method that is based on the radiation heat balance on the surface is used to calculate the radiation heat transfer rate from the inside surface of the cavity receiver to the environment. The Monte-Carlo Method that is the statistical approach is adopted to predict the radiation heat transfer rate from the reflector to the receiver. Based on the heat loss analysis, the performance of two different receivers for multifaceted parabolic solar collectors with several flat facets can be estimated, and the optimal facet size is obtained.

  • PDF

True Metabolisable Energy and True Amino Acid Availability in Chinese Varieties of Dehulled and Hulled Soybean Meals Determined with Adult Roosters

  • Wang, Jitan;Li, Defa;Gong, Limin;Xing, Jianjun;Shen, Huile;Ma, Guolong Song Fabo
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.10
    • /
    • pp.1487-1494
    • /
    • 2003
  • Studies were conducted with intact White Leghorn roosters to determine the true metabolisable energy (TME) and the true amino acid availability (TAAA) in five dehulled and hulled soybean meals produced in China. 60 roosters, kept in individual cages, were fasted for 48 h and then tube-fed 50 g of one of experimental feedstuffs and their excreta was then collected for the subsequent 48 h period. Two separate collection periods were used with each meal being fed to 12 roosters. The birds were given a 15-day recovery period between collection periods. An additional 12 roosters were either fasted or fed a protein-free diet in order to estimate the extent of endogenous losses of energy and amino acids in excreta. The average values per bird for nitrogen loss, endogenous energy losses (EEL) and endogenous energy losses corrected to zero-nitrogen balance ($EEL_n$) were found to be 0.74 g, 47.0 kJ and 21.5 kJ, respectively. It was found that the TME and TAAA values of dehulled soybean meal were higher than those of hulled soybean meal. The TME and nitrogen-corrected TME metabolisable energy values of dehulled soybean meal were 10.58 and 10.74 MJ/kg, respectively, while the corresponding values for hulled soybean meal were 10.03 and 10.27 MJ/kg, respectively. The average indispensable and dispensable amino acid availability of dehulled soybean meal was 92.1 and 93.5%, compared with 89.3 and 91.4% for hulled soybean meal. Dehulled soybean meal would therefore appear to be superior to hulled soybean meal as a source of protein and energy for use in poultry rations.

AC Loss Analysis of 10 MW Class Fully High Temperature Superconducting Synchronous Generators with Dual Field Windings (이중계자를 갖는 10 MW급 전초전도 동기 발전기의 교류손실 해석)

  • Park, Sang Ho;Lee, Myeonghee;Lee, Seyeon;Yang, Hyung Suk;Kim, Woo-Seok;Lee, Ji-Kwang;Choi, Kyeongdal
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.467-472
    • /
    • 2020
  • The superconducting synchronous generator is one of the breakthrough elements for direct-drive wind turbines because it is light and small. Normally the superconducting one has copper armature windings in the stator and superconducting field windings on the rotor. The high resistance of the armature can make large copper losses, comparing with the conventional generators with a gear box. One of the solutions for the large copper losses could be a fully superconducting generator. But the high magnetic fields from the superconducting field windings on the rotor also make high perpendicular magnetic fields on the superconducting tapes in the armature windings. We have proposed a fully superconducting synchronous generator with dual field windings. It could immensely decrease the circumferential component of the magnetic field from the field windings at the armature windings. In this paper, we conceptually designed 3 types of superconducting synchronous generators. The first one is the fully superconducting one with conventional structure, which has superconducting armature windings in the stator and superconducting field windings on the rotor. The second one is the one with dual superconducting field windings and superconducting armature windings between them. The last one is the same as the third one except the structure of the armature. If the concentrated armature windings are superconducting ones with cryostats, then they cannot be installed within the span of 2 poles. So, we adopted 3 phases windings within 4 poles system. It makes more AC losses but can be manufactured really.

A Study for reduction of the power loss of PV modules (PV moudule의 출력손실 저감요인 분석)

  • Lee, Sang-Hun;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.45-50
    • /
    • 2011
  • The efficiency of solar cell was about 4[%] in initial stage of photovoltaic industry, but it has quite a lot of efficiency through technology advances. Today, the efficiency of c-Si solar cells is about 17 to 19[%] and the efficiency of PV modules is about 14 to 15 [%]. We called that electrical losses occurred in the Conversion of solar cells to PV modules are CTM loss(Cell To Module loss), the CTM loss typically has a value of about3~5[%]. The more efficiency of solar cell increase, differences are larger because the efficiency decrease owing to physical or technical problems occurred in the Conversion of solar cells to PV modules. In this study, the power loss factors occurred in the Conversion of solar cells to PV modules are analyzed and it is proposed that how to reduce losses of the PV module. The types of power loss factor are (1)losses of front glass and encapsulant(generally EVA sheet), (2)losses by sorting miss, (3)losses by interconnection, (4)losses by the field aging of PV modules. In further study, experimental and evaluation will be conducted to make demonstrate for proposed solutions.

  • PDF

Rotor Loss Analysis of Permanent Magnet High-Speed Machine According to Magnetization Pattern

  • Cho, Han-Wook;Jang, Seok-Myeong;Lee, Sung-Ho;Yang, Hyun-Sup;Jeong, Yeon-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.3
    • /
    • pp.103-107
    • /
    • 2004
  • Recently, greater attention has been paid to the high-speed generator for its many merits, such as ease of installation, high efficiency and high power density. However, due to their high fundamental frequency, careful consideration needs to be given to both electromagnetic and mechanical design issues. This paper deals with the comparison of two types of permanent magnet high-speed machines. Specifically, the effect of the permanent magnet magnetization pattern on the rotor losses is investigated. On the basis of analytical field analysis and the 2-D finite element method, this paper predicts the flux harmonics and rotor losses under the no-load condition. It is shown that the Halbach magnetization is superior to parallel magnetization in terms of producing rotor losses.

Rotational loss assessment of flywheel energy storage system by Motor/Generator core (전동/발전기 코어에 의한 초전도 플라이휠 에너지 저장장치의 회전손실 특성 평가)

  • Lee, Jeong-Phil;Han, Young-Hee;Jung, Se-Yong;Han, Sang-Chul;Jeong, Nyeon-Ho;Sung, Tae-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1775-1781
    • /
    • 2007
  • In this paper, the rotational loss of the superconductor flywheel energy storage system (SFES) by motor/generator stator core was assessed. To do this, the vertical axial type SFES with journal type superconductor bearing was manufactured. To quantitatively assess the rotational loss by the stator core, the rotational losses by superconductor bearing and the degree of a vacuum were measured. In case of variation of the inner radius and outer radius of the stator core, the rotational losses were measured. From the experimental results, It is confirmed that the rotational loss can be reduced by means of the optimal stator core design.

Optimization Method of Building Energy Performance and Construction Cost Using Kuhn-Tucker Conditions (쿤-터커 조건을 이용한 건물의 에너지성능과 비용 최적화방법)

  • Won, Jong-Seo;Koo, Jae-Oh
    • KIEAE Journal
    • /
    • v.3 no.2
    • /
    • pp.51-58
    • /
    • 2003
  • The purpose of this study is to present rational methods of multi-criteria optimization of the shape of energy saving buildings. The object is to determine the optimum dimension of the shape of a building, based on the following criteria: minimum building costs (including the cost of materials and construction) and yearly heating costs. Mathematical model described heat losses and gains in a building during the heating season. It takes into consideration heat losses through wall, roof, floor and windows. Particular attention was paid to have a more detailed description of heat gains due to solar radiation. On the assumption that shape of building is rectangle in order to solve the problem, the proportions of wall length and building height are determined by using non-linear programing methods(Kuhn-Tucker Conditions). The results constitute information for designers on the optimum proportions of wall lengths, height, and the ratios of window to wall areas for energy saving buildings.

A new lossless snubber for DC-DC converters with energy transfer capability

  • Esfahani, Shabnam Nasr;Delshad, Majid;Tavakoli, Mohhamad Bagher
    • Smart Structures and Systems
    • /
    • v.25 no.3
    • /
    • pp.385-391
    • /
    • 2020
  • In this paper, a new passive lossless snubber circuit with energy transfer capability is proposed. The proposed lossless snubber circuit provides Zero-Current Switching (ZCS) condition for turn-on instants and Zero-Voltage Switching (ZVS) condition for turn-off instants. In addition, its diodes operate under soft switching condition. Therefore, no significant switching losses occur in the converter. Since the energy of the snubber circuit is transferred to the output, there are no significant conduction losses. The proposed snubber circuit can be applied on isolated and non-isolated converters. To verify the operation of the snubber circuit, a boost converter using the proposed snubber is implemented at 70W. Also, the measured conducted Efficiency Electromagnetic Interference (EMI) of the proposed boost converter and conventional ones are presented which show the effects of proposed snubber on EMI reduction. The experimental results confirm the presented theoretical analysis.

Effect on the Cycle Efficiency by Using Improved Parts for Operating the ORC (유기랭킨사이클 작동과 관련한 부품개선에 의한 사이클 효율변화에 대한 영향)

  • Cho, Soo-Yong;Cho, Chong-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.6
    • /
    • pp.34-42
    • /
    • 2016
  • The organic Rankine cycle (ORC) has been used to convert thermal energy to mechanical energy or electricity. The available thermal energy could be waste heat, solar energy, geothermal energy, and so on. However, these kinds of thermal energies cannot be provided continuously. Hence, the ORC can be operated at the off-design point. In this case, the performance of the ORC could be worse because the components of the ORC system designed based on a design point can be mismatched with the output power obtained at the off-design point. In order to improve the performance at the off-design point, a few components were replaced including generator, bearing, load bank, shaft, pump and so on. Experiments were performed on the same facility without including other losses in the experiment. The experimental results were compared with the results obtained with the previous model, and they showed that the system efficiency of the ORC was greatly affected by the losses occurred on the components.

A Study on the Window Energy Rating Systems in Residential Buildings (주거용 건물의 창호에너지평가시스템에 관한 연구)

  • Kim, Dong-Yun;Lim, Hee-Won;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.16 no.2
    • /
    • pp.33-41
    • /
    • 2016
  • Purpose: The window energy rating system was developed in early 1990's and various kind of rating system has been implemented in advanced country such as Europe, Australia, Canada and the US since 2000. In Korea, the Energy Consumption Efficiency Rating Indication System has been implemented to promote supply of high efficiency window since July 2012. Normally, the window energy rating system based on heat balance which considers both thermal losses and solar heat gain is used and applied only to residential buildings. However, the system used nationally only considers thermal losses and is applied to every building regardless of its usage. Therefore, in this study, we indicated problems of domestic window energy rating system and looked for improvements. Method: We analyzed thermal performance of various windows through dynamic simulation applied to detached house and compared results with those of domestic and foreign rating system. Result : Thermal performance of south windows is more affected by SHGC than U-value, and that of north windows is also affected by SHGC a lot. The difference between the results of our study and current system is statistically significant. As a result, appropriate evaluation criteria which considers solar heat gain is required.