• Title/Summary/Keyword: Energy loss reduction

Search Result 338, Processing Time 0.032 seconds

Optimum AC losses Determination for Duty Cycle of Superconductive Magnetic Energy Storage (초전도에너지 저장장치의 운전주기에 따른 최적교류손실 결정에 관한 연구)

  • Hwang, Seuk-Yong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.7
    • /
    • pp.653-667
    • /
    • 1990
  • Superconductor is consolidated, for required current capacity, with proper numbers of basic strands which are multifilamentary composites. Althouth superconductors are perfectly loss-free under DC conditions of current and field, AC losses occur under time-varying condition of the current and field. The AC losses are a controllable inherent characteristics of supercondectors. The AC losses dependent on the changing rate of current and field can be reduced by reducing the filament diameter. On the other hand, finer filament results in manufacturing cost increase. Therefore, in this paper optimization technique of superconductor for SMES is proposed from the viewpoint of AC loss reduction and manufacturing cost increase. The case study shows that the technique can be effectively used for the design of superconductor for SMES, appreciating the influence of various parameters related to superconductor itself and operating condition of SMES. As a result of the case study, it is confirmed that the technique is more effective for the design of superconductor for SMES for electric power power system stabilization rather then SMES for energy storage.

  • PDF

Magnetic Properties of Electrical Steel Material for Electric Machines Core (전기기기 코아용 전기강판 소재의 자기적 특성)

  • 하경호;차상윤;김재관
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.881-883
    • /
    • 2004
  • The high efficiency for motors has been continuously required for energy saving. The iron losses occurring in motor cores account for high percentage in the energy losses of motors, so that electrical steels with lower iron losses have been desired as core materials. It is necessary to understand the basic charecteristic of the electrical steel to design motors and establish manufacturing process for the loss reduction. Therefore, this paper deal with the basic characteristic related with the magnetic properties of electrical steels and descibes the cause of core loss in electrical machines.

  • PDF

Design and Performance Evaluation of Solar Air Receivers (공기식 태양열 흡수기의 설계 및 성능평가)

  • Cho, Hyun-Seok;Lee, Hyun-Jin;Kim, Jong-Kyu;Lee, Sang-Nam;Kang, Yong-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.207-212
    • /
    • 2012
  • It is important to produce the high-temperature and high-pressure air for the concentrated solar power system using the combined cycle. In this paper, we designed two types of tubular receivers to heat up the compressed air and provided their preliminary experimental results for performance evaluation and further improvements. The developed receivers are in a square cavity shape surrounded by flow conduits for easy scale-up and radiation loss reduction. The two receivers were tested with 5 bar air in the KIER solar furnace and evaluated in terms of the outlet temperature and the efficiency.

Study on Loss Reduction for Tilting Disk Check Valve Installed in Piping System (배관용 틸팅디스크 체크밸브의 손실저항 절감에 관한 연구)

  • Kim, J.H.;Park, J.H.;Lee, H.S.;Nam, S.H.;Hwang, S.H.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.327-328
    • /
    • 2006
  • In generally, under the influence of over-pressure drop, serious problems such as cavitation, choked flow, flashing and vibration has been coming around the tilting disk check valve. A PIV experiment to examine the cause of energy loss has been performed and the improvement configuration of valve seat based on this visualization results is proposed. In the visualization results, flows in the piping system became instability under the influence of the shape of boss. This unstable flows induces sudden pressure drop in the piping system. So, we change the configuration of boss as a streamlined design to be stabilized the flows. A pressure measurement has been performed to know that the influence of the configuration change. In result, the rate of pressure loss reduction is about 22% at the position of No. 2 and 24.2% at the position of No. 6 in comparison with pre-improved shape.

  • PDF

A PIV Study on Loss Reduction for Tilting Disk Check Valve Installed in Piping System of Water Supply by PIV (PIV에 의한 상수도 배관용 틸팅디스크 체크 밸브의 손실저감에 관한 연구)

  • Kim, B.S.;Kim, J.H.;Lee, J.Y.;Kim, J.G.;Lee, Y.H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.577-582
    • /
    • 2003
  • In generally, under the influence of over-pressure drop, serious problems such as cavitation, choked flow, flashing and vibration has been coming around the tilting disk check valve. A PIV experiment to examine the cause of energy loss has been performed and the improvement configuration of valve seat based on this visualization results is proposed. In the visualization results, flows in the piping system became instability under the influence of the shape of boss. This unstable flows induces sudden pressure drop in the piping system. So, we change the configuration of boss as a streamlined design to be stabilized the flows. A pressure measurement has been performed to know that the influence of the configuration change. In result, the rate of pressure loss reduction is about 22% at the position of No. 2 and 24.2% at the position of No. 6 in comparison with pre-improved shape.

  • PDF

Study and Recovery on the Capacity Loss after the Long Charge-discharge Operation of VRFB-ESS (장시간 충방전에 따른 VRFB-ESS의 용량 손실 회복에 대한 연구)

  • Hai-Kyung, Seo;Wonshik, Park;Jae-woo, Park;Kangsan, Kim;Hansol, Choi
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.181-187
    • /
    • 2022
  • As the charges/discharges of VRFB-ESS were repeated during 150cycles or more, the capacity of electrolyte in VRFB-ESS was decreased little by little. It results from the decreasing of the level of anolyte and the increasing of the valance value of the catholyte. Then, we tried to recover the capacity loss with 3 different ways. The first way was that the levels of anolyte and catholyte were allowed to be evenly equalized when the difference in the levels of two different electrolytes were severe. The second one was to lessen the valance value of the catholyte through the reduction reaction to 4-valant ions of 5-valant ions in the catholyte with the reductant, oxalic acid. The last one was that the all electrolytes of analyte and catholyte were allowed to be electro-chemically reduced to 3.5 of the valance value by oxidizing new electrolyte with 3.5 valance ions. The last way was the most effective to recover the capacity loss.

A Second-order Harmonic Current Reduction with a Fast Dynamic Response for a Two-stage Single-phase Grid-connected Inverter

  • Jung, Hong-Ju;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1988-1994
    • /
    • 2014
  • In a single-phase grid-connected power system consisting of a DC/DC converter and a DC/AC converter, the current drawn from renewable energy sources has a tendency to be pulsated and contains second-order frequency ripple components, which results in several drawback such as a power harvesting loss and a shortening of the energy source's life. This paper presents a new second-order harmonic current reduction scheme with a fast dc-link voltage loop for two-stage dc-dc-ac grid connected systems. In the frequency domain, an adequate control design is performed based on the small signal transfer function of a two-stage dc-dc-ac converter. To verify the effectiveness of proposed control algorithm, a 1 kW hardware prototype has been built and experimental results are presented.

The Study of Method about the Multi-channel Simultaneous Measurement for Measuring the I-V Curve of Photovoltaic Array (태양광 어레이 I-V 곡선 측정을 위한 다채널 동시 측정방법에 관한 연구)

  • Park, Yu-Na;Jang, Gil-Soo;Ko, Suk-Whan;Kang, Gi-Hwan;So, Jung-hun;Jung, Young-Seok;Ju, Young-Chul;Hwang, Hye-Mi;Song, Hyung-Jun
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.4
    • /
    • pp.23-33
    • /
    • 2017
  • A great deal of study for loss reduction of photovoltaic system is conducted currently. It is hard to distinct the fault of photovoltaic system with the naked eye. For that reason, it is essential to repair and maintain the PV system by monitoring the system. The fault of individual modules can cause the huge loss of the entire system because of the mismatch. Therefore, the method of diagnosing the PV array is necessary by measuring the multi-channel arrays simultaneously. In this paper, it is presented the method of measuring I-V curve of multi-channel arrays simultaneously by using the charge and discharge characteristics of capacitor. Generated DC power at PV arrays is charged and discharged at the capacitors in a moment. By measuring the charged voltage and current, it is possible to diagnose of performance of PV arrays.

Loss of Li2O Caused by ZrO2 During the Electrochemical Reduction of ZrO2 in Li2O-LiCl Molten Salt (Li2O-LiCl 용융염을 이용한 ZrO2의 전기화학적 환원과정에서 발생하는 Li2O의 손실)

  • Park, Wooshin;Hur, Jin-Mok;Choi, Eun-Young;Kim, Jong-Kook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.4
    • /
    • pp.229-236
    • /
    • 2012
  • A molten salt technology using $Li_2O$-LiCl has been extensively investigated to recover uranium metal from spent fuels in the field of nuclear energy. In the reduction process, it is an important point to maintain the concentration of $Li_2O$. $ZrO_2$ is inevitably contained in the spent fuels because Zr is one of the main components of fuel rod hulls. Therefore, the fate of $ZrO_2$ in $Li_2O$-LiCl molten salt has been investigated. It was found that $Li_2ZrO_3$ and $Li_4ZrO_4$ were formed chemically and electrochemically and they were not reduced to Zr. The recycling of $Li_2O$ is the key mechanism ruling the total reaction in the electrolytic reduction process. However, $ZrO_2$ will have a role as a $Li_2O$ sink.

A Study on the Alkali Hydrolysis of PET fabric with Ultrasonic Application(I) - Decomposition Rate Constant and Activation Energy - (초음파를 적용한 PET 직물의 알칼리 가수분해에 관한 연구(I) - 분해속도상수와 활성화 에너지-)

  • 서말용;조호현;김삼수;전재우;이승구
    • Textile Coloration and Finishing
    • /
    • v.14 no.4
    • /
    • pp.214-222
    • /
    • 2002
  • In order to give a silk-like touch to PET fabrics, the PET fabrics were treated with NaOH alkaline solution in various conditions. In alkaline treatment, the liquor flow type pilot weight reduction apparatus with magnetostrictive ultrasonic transducer was used for the study. The weight loss of PET fabrics hydrolyzed in 4% and 6% NaOH solution, at $95^\circ{C}$ and $99^\circ{C}$ for 60min. with ultrasonic application showed 3.7~4.6% higher than that of treated fabric without ultrasonic application. From the difference of specific weight loss, the treatment condition of the maximum of hydrolyzation effect appeared at $95^\circ{C}$ in $4^\circ{C}$ and at $90^\circ{C}$ in 6% NaOH solution, respectively. During the alkali hydrolysis of PET fabrics, the decomposition rate constant(k) increased exponentially with the treatment temperature and were not related with ultrasonic cavitation. The activation energy$(E_a)$ in decomposition of PET fabrics were 21.06kcal/mol with ultrasonic application and 21.10kcal/mol without ultrasonic application. The ultrasonic application gave a little higher value of the activation entropy$(\Delta{S}^\neq)$ and a little lower value of Gibbs free energy$(\Delta{S}^\neq)$ compared with not used ultrasonic apparatus.