• Title/Summary/Keyword: Energy loss reduction

Search Result 338, Processing Time 0.026 seconds

Thermal Performance of Building Envelope with Transparent Insulation Wall (건물 외피 투과형단열 벽체의 열성능 해석 연구)

  • Jang, Yong-Sung;Yoon, Yong-Jin;Park, Hyo-Soon
    • KIEAE Journal
    • /
    • v.5 no.1
    • /
    • pp.27-33
    • /
    • 2005
  • Global efforts have made to reduce energy consumption and $CO_2$ gas emission. One of the weakest parts for energy loss through the whole building components is building envelopes. Lots of technologies to increase the thermal performance of building envelopes have been introduced in recent year. Transparent Insulation Wall(TIW) is a new technology for building insulation and has been function both solar transmittance and thermal insulation. A mathematical model of a Transparent Insulation Wall equipped with south wall was proposed in order to predict thermal performance under varying climates(summer and winter). Unsteady state heat transfer equations were set up using an energy balance equation and solved using Gauss-Seidel iteration solution procedure. The thermal performance of the TIW determined from a wall surface and air layer temperature, non-airconditioned room temperature and air conditioning load. As a result, this numerical study shows that the TIW is effective in an air conditioning load reduction. Further experimental study is required to establish complete TIW system.

Integrated design method of suction muffler in compressor (압축기 흡입 머플러 통합적 설계 방안)

  • Wang, Semyung;Oh, Seungjae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.771-772
    • /
    • 2014
  • In this paper, the integrated design method of suction muffler in compressor was studied. There are three things to consider when designing this. First, the transmission loss was maximized to consider the noise reduction. Second, dissipation energy of fluid flow was minimized for energy efficiency. Finally, acoustical resonance frequency of suction muffler was controlled because energy efficiency can be increased by supercharging of refrigerant. Therefore, suction muffler was designed to have the specific resonance frequency. The input impedance was used for designing target acoustical resonance frequency. Topology optimization was used for optimization method.

  • PDF

Study of Reduction of Mismatch Loss of a Thermoelectric Generator (열전발전 시스템의 부정합손실 저감방안 연구)

  • Choi, Taeho;Kim, Tae Young
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.3
    • /
    • pp.294-301
    • /
    • 2022
  • In this study, a multi-layer cascade (MLC) electrical array configuration method for thermoelectric generator consisting of plural number of thermoelectric modules (TEMs) was proposed to reduce mismatch loss caused by temperature maldistribution on the surfaces of the TEMs. To validate the effect of MLC on the mismatch loss reduction, a numerical model capable of reflecting multi-physics phenomena occuring in the TEMs was developed. MLC can be employed by placing a group of TEMs experiencing relatively low temperature differences in an electric layer with more electrical branches while locating a group of TEMs experiencing relatively high temperature differences in an electric layer with less electrical branches. The TEMs were classified using the temperature distribution obtained by the numerical model. A MLC with an optimal electrical branch ratio showed a 96.5% of electric power generation compared to an ideal case.

Airtightness of Light-Frame Wood Houses built in Daejeon and Chungnam Area

  • Jang, Sang-sik;Ha, Been
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.147-158
    • /
    • 2017
  • Among the energy consumption in building, the heating energy takes the largest part. Therefore, it is important to minimize the heat energy loss in building for the reduction of overall energy use in construction. The most important points for the minimization of energy loss in building are insulation and airtightness. Especially, in wood houses, airtightness is very important for energy saving as well as increase of durability. However, the researches on airtightness of wood buildings have been started recently and are very deficient especially in Korea. In this study, air leakage properties and airtightness performance were evaluated for light-frame wood houses built in Daejeon and Chungnam area. Total 7 houses were evaluated, among which four houses (Case 1 to Case 4) were in the construction stage before interior finish and the other three houses (Case 5 to Case 7) were after completion of construction work. The tests for airtightness were conducted by pressurization-depressurization method, and the factors included in the measurements includes air leakage rate at 50 Pa (CMH50), air change rate at 50 Pa (ACH50), equivalent leakage area (EqLA) and EqLA per floor area. As a result of this study, key air leakage points in wood houses were found to be the gaps between floor and wall, the holes for wiring and plumbing, the double glasses windows and the entrance doors. The average value of ACH50 for the houses after completion of construction work was $3.5h^{-1}$ that was similar to Europe standard ($3.0h^{-1}$). ACH50 was proportional to EqLA per floor area but inversely proportional to the internal volume, the net floor area and the area of window.

A Loss-Minimization Nonlinear Torque Control for Electrical Vehicle Induction Motors (전기자동차용 유도전동기의 에너지 손실을 최소화하는 비선형 토크 제어기 설계)

  • Jang, Jin-Su;Han, Byung-Jo;Hwang, Young-Ho;Kim, Hong-Pil;Yang, Hai-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1838-1839
    • /
    • 2006
  • In this paper, a loss-minimization nonlinear torque control for Electrical Vehicle(EV) induction motors is proposed. To improve the efficiency of the induction motors, it is important to find the optimal flux reference that minimize power losses. The proposed optimal flux reference is derived using a power loss function that is constructed with stator resistance losses, rotor resistance losses and core losses. And the time-varying load torque and the rotor resistance variation are considered in the power loss function. An algorithm that identifying the load torque is used. The rotor flux observer is used to obtain an accurate flux value regardless of the rotor resistance variation. Simulation results show a significant reduction in energy losses.

  • PDF

Effects of Rice Bran Fiber on Quality of Low-fat Tteokgalbi

  • Choi, Yun-Sang;Choi, Ji-Hun;Han, Doo-Jeong;Kim, Hack-Youn;Lee, Mi-Ai;Lee, Eui-Soo;Jeong, Jong-Youn;Paik, Hyun-Dong;Kim, Cheon-Jei
    • Food Science and Biotechnology
    • /
    • v.17 no.5
    • /
    • pp.959-964
    • /
    • 2008
  • This study evaluated the effects of dietary fiber extracted from rice bran (rice bran fiber) on the quality of low-fat tteokgalbi. The controls were formulated with 20% added fat. Test samples of tteokgalbi were produced with 5 different formulations containing 1, 2, 3, 4, and 5% rice bran fiber as a fat replacer, in addition to 10% fat. The control had the highest fat content, energy value, cooking loss, reduction in diameter, reduction in thickness, CIE $L^*$-value (lighness), and color of sensory properties. The tteokgalbi containing rice bran fiber had higher moisture, protein, ash, and carbohydrate contents than the controls. Tteokgalbi with 3% rice bran fiber had the lowest cooking loss, reduction in diameter, and reduction in thickness. Meat products containing 2 and 3% rice bran fiber had a higher overall acceptability similar to the high fat control.

A Novel Current-fed Energy Recovery Sustaining Driver for Plasma Display Panel(PDP)

  • Han, Sang-Kyoo;Moon, Gun-Woo;Youn, Myung-Joong
    • Journal of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.39-45
    • /
    • 2004
  • A novel current-fed energy-recovery sustaining driver (CFERSD) for a PDP is proposed in this paper. Its main idea is to recover the energy stored in the PDP or to inject the input source energy to the PDP by using the current source built-up in the energy recovery inductor. This method provides zero-voltage-switching (ZVS) of all main power switches, the reduction of EMI, and more improved operational voltage margins with the aid of the discharge current compensation. In addition, since the current flowing through the energy recovery inductor can compensate the plasma discharge current flowing through the conducting power switches, the current stress through all main power switches can be considerably reduced. Furthermore, it features a low conduction loss and fast transient time. Operations, features and design considerations are presented and verified experimentally on a 1020${\times}$l06mm sized PDP, 50kHz-switching frequency, and sustaining voltage 140V based prototype.

Aerodynamic assessment of airfoils for use in small wind turbines

  • Okita, Willian M.;Ismail, Kamal A.R.
    • Advances in Energy Research
    • /
    • v.6 no.1
    • /
    • pp.35-54
    • /
    • 2019
  • A successful blade design must satisfy some criterions which might be in conflict with maximizing annual energy yield for a specified wind speed distribution. These criterions include maximizing power output, more resistance to fatigue loads, reduction of tip deflection, avoid resonance and minimize weight and cost. These criterions can be satisfied by modifying the geometrical parameters of the blade. This study is dedicated to the aerodynamic assessment of a 20 kW horizontal axis wind turbine operating with two possible airfoils; that is $G{\ddot{o}}ttingen$ 413 and NACA 2415 airfoils (the Gottingen airfoil never been used in wind turbines). For this study parameters such as chord (constant, tapered and elliptic), twist angle (constant and linear) are varied and applied to the two airfoils independently in order to determine the most adequate blade configuration that produce the highest annual energy output. A home built numerical code based on the Blade Element Momentum (BEM) method with both Prandtl tip loss correction and Glauert correction, X-Foil and Weibull distribution is developed in Matlab and validated against available numerical and experimental data. The results of the assessment showed that the NACA 2415 airfoil section with elliptic chord and constant twist angle distributions produced the highest annual energy production.

Suppression of Dielectric Loss at High Temperature in (Bi1/2Na1/2)TiO3 Ceramic by Controlling A-site Cation Deficiency and Heat Treatment

  • Lee, Ju-Hyeon;Lee, Geon-Ju;Pham, Thuy-Linh;Lee, Jong-Sook;Jo, Wook
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.7-13
    • /
    • 2020
  • Dielectric capacitors are integral components in electronic devices that protect the electric circuit by providing modulated steady voltage. Explosive growth of the electric automobile market has resulted in an increasing demand for dielectric capacitors that can operate at temperatures as high as 400 ℃. To surpass the operation temperature limit of currently available commercial capacitors that operate in temperatures up to 125 ℃, Bi1/2Na1/2TiO3 (BNT), which has a large temperature-insensitive dielectric response with a maximum dielectric permittivity temperature of 300 ℃, was selected. By introducing an intentional A-site cation deficiency and post-heat treatment, we successfully manage to control the dielectric properties of BNT to use it for high-temperature applications. The key feature of this new BNT is remarkable reduction in dielectric loss (0.36 to 0.018) at high temperature (300 ℃). Structural, dielectric, and electrical properties of this newly developed BNT were systematically investigated to understand the underlying mechanism.

Effect of Complete Fasting on Energy Metabolites and Serum Parathyroid Hormone and Mineral Excretion in Women (여성에서 절식이 에너지 대사산물 및 혈청 PTH 수준과 무기질 배설에 미치는 영향)

  • 박현서;이은옥
    • Journal of Nutrition and Health
    • /
    • v.34 no.5
    • /
    • pp.547-553
    • /
    • 2001
  • This study was designed to observe the change of body composition and nutrient metabolites and the excretion of minerals during complete fasting for 10 days in thirty women. Average loss of body weight was 7.98kg and body fat was gradually reduced after 9 days fasting, but the loss of lean body mass was reduced after 7 days fasting. Serum glucose level was sustained at constant level, but serum levels of blood urea nitrogen, free acid and $\beta$-hydroxybutyrate were significantly increased during fasting but decreased after re-feeding. Urinary excretions of 3-methylhistidine, total creatinine, and urea were high in the beginning of fasting but gradually decreased. Serum level of parathyroid hormone was significantly reduced by fasting but regained after re-feeding. Serum level of minerals was at the constant level throughout the experimental period. The urinary excretion of minerals(Ca, K, Mg, P) was significantly increased in the early stage of fasting and then reduced from 7 days, but the excretion of Zn was continuously increased until the late stage of fasting. These results showed that amino acid fatty acid released from the breakdown of muscle protein and body fat, respectively, were utilized for energy during fasting. Body weight and BMI were reduced because of the increased muscle protein breakdown and body water excretion during early stage of fasting, but the significant body fat loss was after 9 days fasting. Therefore, it could be suggested to fast for longer than 10 days if the reduction of body fat was planned by fasting, and recommed to exercise and ingest more vitamins and minerals to replace the excreted minerals during fasting. (Korean J Nutrition 34(5) : 547~553, 2001)

  • PDF