• 제목/요약/키워드: Energy load variation

검색결과 305건 처리시간 0.024초

Design of QFT controller of superconductor flywheel energy storage system for load frequency control

  • Lee, J.P.;Kim, H.G.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권1호
    • /
    • pp.19-24
    • /
    • 2013
  • In this paper, the Superconductor flywheel energy storage system (SFESS) was used for the load frequency control (LFC) of an interconnected 2 area power system. The robust SFESS controller using quantitative feedback theory (QFT) was designed to improve control performance in spite of parameter uncertainty and unexpected disturbances. An overlapping decomposition method was applied to simplify SFESS controller design for the interconnected 2 area power system. The model for simulation of the interconnected 2 area power system included the reheat steam turbine, governor, boiler dynamics and nonlinearity such as governor deadband and generation rate constraint (GRC). To verify robust performance of proposed SFESS controller, dynamic simulation was performed under various disturbances and parameters variation of power system. The results showed that the proposed SFESS controller was more robust than the conventional method.

A Simple Power Management Scheme with Enhanced Stability for a Solar PV/Wind/Fuel Cell Fed Standalone Hybrid Power Supply using Embedded and Neural Network Controller

  • Thangavel, S.;Saravanan, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1454-1470
    • /
    • 2014
  • This paper propose a new power conditioner topology with intelligent power management controller that integrates multiple renewable energy sources such as solar energy, wind energy and fuel cell energy with battery backup to make best use of their operating characteristics and obtain better reliability than that could be obtained by single renewable energy based power supply. The proposed embedded controller is programmed for maintaining a constant voltage at PCC, maximum power point tracking for solar PV panel and WTG and power flow control by regulating the reference currents of the controller on instantaneous basis based on the power delivered by the sources and load demand. Instantaneous variation in reference currents of the controller enhances the controller response as it accommodates the effect of continuously varying solar insolation and wind speed in the power management. The power conditioner uses a battery bank with embedded controller based online SOC estimation and battery charging system to suitably sink or source the input power based on the load demand. The simulation results of the proposed power management system for a standalone solar/WTG/fuel cell fed hybrid power supply with real time solar radiation and wind velocity data collected from solar centre, KEC for a sporadically varying load demand is presented in this paper and the results are encouraging in reliability and stability perspective.

정적하중과 사용하중하에서 유리 섬유로 보강된 교량 바닥판의 거동특성에 대한 비교 (Behavior Characteristics Comparison of Bridge Decks Strengthened with Glass Fiber Sheets On the Static Load and Service Load)

  • 심종성;오홍섭;류승무;김영호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.59-64
    • /
    • 2001
  • The concrete bridge decks are in need of replacement and rehabilitation due to decreasing load carrying capacity. In this study, to extend life cycle of the concrete bridge decks which are reinforced with the glass fiber sheets, the concrete bridge decks are examined on the strengthen effect and the fatigue behavior. The behavior of strengthened slabs is represented by load-displacement relationship, variation of compliance and total released energy. Owing to result of that, the strengthened slabs is modified the elasticity, the compliance and represents to control the crack elongation, to elevate the total released energy, to modify the fatigue life. When the concrete bridge deck is strengthened, the crack propagation nay be controled efficiently.

  • PDF

중소형 건물 태양광발전시스템의 실증 연구 (Field Test Study of Photovoltaic Generation System for Medium and Small-Sized Buildings)

  • 김응상;김슬기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.561-565
    • /
    • 2006
  • The paper presents a method of assessing the adequate tapaclty of photovoltaic generation systems for public buildings based on analysis of load variation patterns of customers. When PV systems are installed for supplying power for the customer load, reverse power relay is required by the guideline to be installed at the point of common coupling with the power network. The suggested method analyzes daily, weekly and monthly load demand of the customer that Irishes PV system installation, and determines the appropriate rating of the PV system for preventing PV generation from exceeding the customer demand. This work is expected to support renewable energy dissemination projects of public organizations.

  • PDF

연료전지를 적용한 무정전전원장치용 3상 AC/DC 컨버터의 DC-Link 전압 리플 저감 (Reduction of DC-Link Voltage Ripple of Three-phase AC/DC Converter for Uninterruptible Power Supply by Applying Fuel Cell)

  • 박진호;김경민;이정효;원충연
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.43-51
    • /
    • 2010
  • 기존의 무정전전원장치(UPS: Uninterruptible Power Supply)는 배터리를 보조전원으로 사용함으로써 큰 부피와 수명에 제한을 받게 될 뿐만 아니라, 급격한 부하변동에 따른 배터리 전압의 변동으로 UPS 시스템 출력에 문제점을 야기한다. 본 논문에서는 보조전원으로 쓰이는 기존의 배터리 대신에 친환경 대체 에너지원인 연료전지를 무정전전원장치용 3상 AC/DC 컨버터에 적용하여 급격한 부하 변동 시 에너지를 보상하고 안정된 출력을 갖도록 하였다.

A Novel Double-Loop Vector Control Strategy for PMSMs Based on Kinetic Energy Feedback

  • Wang, Anbang;Wang, Qunjing;Jiang, Weidong
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1256-1263
    • /
    • 2015
  • A novel vector control strategy for a permanent magnet synchronous motor (PMSM) based on the kinetic energy stored in the rotor is proposed in this paper. The novel strategy is composed of two closed loops, in which the current loop is the inner loop, and the kinetic energy serves as the outer loop. The theoretical basis and the design procedure of the two loops are given. The feasibility of the proposed control strategy is verified by experimental results. When compared with traditional vector control strategies, the proposed vector control strategy based on energy feedback has better dynamic performance. In addition, an effective estimation solution for the load variation is put forward.

인버터 압축기의 저속과 고속운전범위가 계절성능에 미치는 영향 (The effect on the seasonal performance of an inverter compressor with higher and lower operating range)

  • 박윤철;하도용;민만기
    • 설비공학논문집
    • /
    • 제10권2호
    • /
    • pp.173-179
    • /
    • 1998
  • An experimental study was conducted on the effect of compressor capacity control range of heat pump on the seasonal energy efficiency ratio with variation of the maximum and minimum compressor input frequencies. To obtain seasonal energy efficiency ratio, steady state test at the maximum, minimum and intermediate compressor speed and cyclic test at the minimum compressor speed should be conducted. Maximum input frequency was varied to 95Hz, 105Hz, and 115Hz, and the minimum input frequency was varied to 35Hz, 45Hz, and 55Hz. The seasonal energy efficiency ratio increased as the input frequency of the compressor decreased. The maximum input frequency had only slight effects on the SEER.

  • PDF

지하대수층을 이용한 축열시스템의 설계 (I) : 등온해석 (Design of an Aquifer Thermal Energy Storage System (I) : Isothermal Analysis)

  • 송영길;이관수;이태희;김양현
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.102-110
    • /
    • 1993
  • An isothermal analysis was conducted to develop the design tool of an aquifer thermal energy storage system. Taejeon aquifer was chosen for the analysis, and the variation of FRE(Fluid Recovery Efficiency) with respect to the aquifer natural velocity and thermal load were investigated. The analysis results were compared with those of ATESSS(Aquifer Thermal Energy Storage System Simulator) and agreed within 2% of discrepancy. It is recommended, based on the result of this study, that the system may be suitable for a large volume of hot or chill thermal energy storage system, such as for district heating or cooling.

  • PDF

풍속자료(風速資料) 분석(分析)에 의한 풍역발전(風力發電)시스템 최적(最適) 설계(設計) (Optimum Design of a Wind Power Generation System through Analysis of Wind Data)

  • 이철형;신동열
    • 태양에너지
    • /
    • 제4권2호
    • /
    • pp.3-12
    • /
    • 1984
  • In this paper, how to design the wind power generation system is presented. It is shown that the wind system optimization can be achieved by consideration of the four factors; wind statistics, efficiency of conversion of wind energy to electrical energy, average annual energy extracted and load factor. The wind is characterized by a weibull probability function. The Weibull parameter is calculated for the characterizing wind and the primary design specification of ten different sites. Some graphs are presented, which can be used to design a wind system for maximum output of a specified load factor at given site. Two different systems, $V_c=0.4V_R$ and $V_c=0.5V_R$ are discussed, as samples, for investigation of the effects on the system through the variation of cut-in speed.

  • PDF

Tank모델에 의한 영일만 유입오염부하량의 계절변동 예측 (Seasonal Variation Estimation of Inflow Pollutant Loads of Yeong-il Bay by using Tank Model)

  • 이인철
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제6권3호
    • /
    • pp.63-71
    • /
    • 2003
  • 형산강 유역의 일별 하천유량과 오염부하량을 산정하기 위한 유역유출모형(강우-유출모형)인 Tank 모델을 구축하여 영일만으로 유입하는 오염부하량의 계절별 변동특성에 대해 검토하였다. 산정된 영일만으로 유입되는 형산강의 연평균 하천유량은 878.34×10/sup 6/㎥/year로 형산강 유역면적내 연평균 총강우량의 약 73%로 나타났다. 영일만내 유입되는 연평균 오염부하량은 각각 15.11 ton-COD/year, 23.24 ton-SS/year, 10.65 ton-TN/year, 0.54 ton-Tp/year로 산정되었다 또한 계절별 변동특성으로 하천유량이 증가하는 하계 6~7월과 춘계 10월에 유입오염부하량도 증가하는 경향을 보였다. 영일만내로 유입하는 주된 오염부하원은 형산강 하구인근에 위치한 포항시와 포항공단인 것으로 밝혀졌다. 따라서 영일만의 효율적인 수질관리를 위해서는 오염부하원으로부터의 오염부하량 저감대책수립이 요구된다.

  • PDF