• 제목/요약/키워드: Energy input-output analysis

검색결과 247건 처리시간 0.027초

Optimal Harmonic Stepped Waveform Technique for Solar Fed Cascaded Multilevel Inverter

  • Alexander, S.Albert;Thathan, Manigandan
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.261-270
    • /
    • 2015
  • In this paper, the Optimal Harmonic Stepped Waveform (OHSW) method is proposed in order to eliminate the selective harmonic orders available at the output of cascaded multilevel inverter (CMLI) fed by solar photovoltaic (SPV). This technique is used to solve the harmonic elimination equations based on stepped waveform analysis in order to obtain the optimal switching angles which in turn reduce the Total Harmonic Distortion (THD). The OHSW method considers the output voltage waveform as four equal symmetries in each half cycle. In the proposed method, a solar fed fifteen level cascaded multilevel is considered where the magnitude of six numbers of harmonic orders is reduced. A programmable pulse generator is developed to carry the switching angles directly to the semiconductor switches obtained as a result of OHSW analysis. Simulations are carried out in MATLAB/Simulink in which a separate model is developed for solar photovoltaic which serves as the input for cascaded multilevel inverter. A 3kWp solar plant with multilevel inverter system is implemented in hardware to show the effectiveness of the proposed system. Based on the observation the OHSW method provides the reduced THD thereby improving power quality in renewable energy applications.

ANALYSIS OF TMI-2 BENCHMARK PROBLEM USING MAAP4.03 CODE

  • Yoo, Jae-Sik;Suh, Kune-Yull
    • Nuclear Engineering and Technology
    • /
    • 제41권7호
    • /
    • pp.945-952
    • /
    • 2009
  • The Three Mile Island Unit 2 (TMI-2) accident provides unique full scale data, thus providing opportunities to check the capability of codes to model overall plant behavior and to perform a spectrum of sensitivity and uncertainty calculations. As part of the TMI-2 analysis benchmark exercise sponsored by the Organization for Economic Cooperation and Development Nuclear Energy Agency (OECD NEA), several member countries are continuing to improve their system analysis codes using the TMI-2 data. The Republic of Korea joined this benchmark exercise in November 2005. Seoul National University has analyzed the TMI-2 accident as well as the currently proposed alternative scenario along with a sensitivity study using the Modular Accident Analysis Program Version 4.03 (MAAP4.03) code in collaboration with the Korea Hydro and Nuclear Power Company. Two input files are required to simulate the TMI-2 accident with MAAP4: the parameter file and an input deck. The user inputs various parameters, such as volumes or masses, for each component. The parameter file contains the information on TMI-2 relevant to the plant geometry, system performance, controls, and initial conditions used to perform these benchmark calculations. The input deck defines the operator actions and boundary conditions during the course of the accident. The TMI-2 accident analysis provided good estimates of the accident output data compared with the OECD TMI-2 standard reference. The alternative scenario has proposed the initial event as a loss of main feed water and a small break on the hot leg. Analysis is in progress along with a sensitivity study concerning the break size and elevation.

태양광 발전을 위한 발전량 예측 모델 분석 (Analysis of prediction model for solar power generation)

  • 송재주;정윤수;이상호
    • 디지털융복합연구
    • /
    • 제12권3호
    • /
    • pp.243-248
    • /
    • 2014
  • 최근 태양광에너지는 실시간 태양의 위치를 추적하여 모듈경사각과 이루는 갓을 산정하여 일사량을 보정하는 부분에서 컴퓨팅과의 결합이 확대되고 있다. 태양광 발전은 태양의 위치에 따라 출력변동이 심하고 출력 예측이 어려워 효율적인 전력 생산을 위해서 신재생에너지를 전력계통에 안정적으로 연계할 수 있는 기술이 필요하다. 본 논문에서는 실증단지 내 발전단지의 실시간 기상자료 예측값을 이용하여 최종적으로 태양광 발전량 예측값을 산정하는 태양광 발전을 위한 발전량 예측 모델을 분석한다. 태양광 발전량은 태양광 발전기별 모듈특성, 온도 등을 감안하여 보정계수를 입력하고 예측 지역의 위치 경사각을 분석하여 발전량 예측 계산 알고리즘을 통해 최종 발전량을 예측한다. 또한, 제안 모델에서는 실시간 기상청 관측자료와 실시간 중기 예측 자료를 입력 자료로 사용하여 단기 예측 모델을 수행한다.

의사결정나무와 자료포락 분석을 이용한 공공기관 유형별 환경효율성에 대한 연구 (A Study on Eco-Efficiency in Public Sector Using Decision Tree and DEA Analysis)

  • 임미선;김진화;최순재
    • 한국경영과학회지
    • /
    • 제40권1호
    • /
    • pp.91-116
    • /
    • 2015
  • This study aims to provide public sectors with eco-efficiency information. To implement the purposes of the study, environmental and economic variables of Eco-Efficiency were identified through decision tree model, then the relative Eco-Efficiencies of 243 public sectors were evaluated through input-oriented DEA (Data Envelopment Analysis) model. Specifically, the amount of public purchasing per a staff and the amount of energy use per a staff were considered as input factors. Sales per a staff was considered as output factor. The result shows that most of the public sectors (94.2%) were evaluated as "inefficient" taking into consideration of average value, 0.501 from market-based public corporations, 0.288 from local public corporations, 0.28 from quasi-market-based public corporations, 0.269 from fund-management-based quasi-governmental institutions, 0.09 from non-classified public institutions, and 0.078 from commissioned-service-based quasi-governmental institutions. Furthermore, it is possible to establish a plan for internal Eco-Efficiency improvement based on information of the reference set. In order to improve the Eco-Efficiency in the public sectors in the long term, environmental impacts of the overall public sectors' operations (e.g., energy saving, water saving, waste reduction, and purchasing of green products) needs to be properly proposed in consideration of BSC (Balanced Scorecard) indicators of public sectors.

전역 민감도 분석을 이용한 건물 에너지 성능평가의 합리적 개선 (Rational Building Energy Assessment using Global Sensitivity Analysis)

  • 유영서;이동혁;김선숙;박철수
    • 대한건축학회논문집:구조계
    • /
    • 제36권5호
    • /
    • pp.177-185
    • /
    • 2020
  • The building energy performance indicator, called Energy Performance Index (EPI), has been used for the past decades in South Korea. It has a list of design variables assigned with weighting factors (a, b). Unfortunately, the current EPI method is not performance-based but very close to a prescriptive rating. With this in mind, this study aims to propose a new performance-based EPI method. For this purpose, a global sensitivity analysis method, Sobol, is employed. The Sobol method is suitable for complex nonlinear models and can decompose all the output variance due to every input. The Sobol sensitivity index of each variable is defined as 0 to 1 (0 to 100%), and the sum of all sensitivity indices is equal to 1 (100%). In this study, an office building was modeled using EnergyPlus and then the Latin Hypercube Sampling (LHS) was conducted to generate a surrogate model to EnergyPlus. The sensitivity index was suggested to replace weight (a) in the existing EPI. In addition, the discrete weight (b) in the existing EPI was replaced by a set of continuous regression functions. Due to the introduction of the sensitivity index and the continuous regression functions, the new proposed approach can provide far more accurate outcome than the existing EPI (R2: 0.83 vs. R2: 0.01 for cooling, R2: 0.66 vs. R2: 0.01 for total energy). The new proposed approach proves to be more rational, objective and performance-based than the existing EPI method.

Secrecy Spectrum and Secrecy Energy Efficiency in Massive MIMO Enabled HetNets

  • Zhong, Zhihao;Peng, Jianhua;Huang, Kaizhi;Xia, Lu;Qi, Xiaohui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권2호
    • /
    • pp.628-649
    • /
    • 2017
  • Security and resource-saving are both demands of the fifth generation (5G) wireless networks. In this paper, we study the secrecy spectrum efficiency (SSE) and secrecy energy efficiency (SEE) of a K-tier massive multiple-input multiple-output (MIMO) enabled heterogeneous cellular network (HetNet), in which artificial noise (AN) are employed for secrecy enhancement. Assuming (i) independent Poisson point process model for the locations of base stations (BSs) of each tier as well as that of eavesdroppers, (ii) zero-forcing precoding at the macrocell BSs (MBSs), and (iii) maximum average received power-based cell selection, the tractable lower bound expressions for SSE and SEE of massive MIMO enabled HetNets are derived. Then, the influences on secrecy oriented spectrum and energy efficiency performance caused by the power allocation for AN, transmit antenna number, number of users served by each MBS, and eavesdropper density are analyzed respectively. Moreover, the analysis accuracy is verified by Monte Carlo simulations.

MIMO-aided Efficient Communication Resource Scheduling Scheme in VDES

  • Sung, Juhyoung;Cho, Sungyoon;Jeon, Wongi;Park, Kyungwon;Ahn, Sang Jung;Kwon, Kiwon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권8호
    • /
    • pp.2736-2750
    • /
    • 2022
  • As demands for the maritime communications increase, a variety of functions and information are required to exchange via elements of maritime systems, which leads communication traffic increases in maritime frequency bands, especially in VHF (Very High Frequency) band. Thus, effective resource management is crucial to the future maritime communication systems not only to the typical terrestrial communication systems. VHF data exchange system (VDES) enables to utilize more flexible configuration according to the communication condition. This paper focuses on the VDES communication system among VDES terminals such as shore stations, ship stations and aids to navigation (AtoN) to address efficient resource allocation. We propose a resource management method considering a MIMO (Multiple Input Multiple Output) technique in VDES, which has been widely used for modern terrestrial wireless networks but not for marine environments by scheduling the essential communication resources. We introduce the general channel model in marine environment and give two metrics, spectral and the energy efficiencies to examine our resource scheduling algorithm. Based on the simulation results and analysis, the proposed method provides a possibility to enhance spectral and energy efficiencies. Additionally, we present a trade-off relationship between spectral and energy efficiencies. Furthermore, we examine the resource efficiencies related to the imperfect channel estimation.

Analysis and Implementation of PS-PWAM Technique for Quasi Z-Source Multilevel Inverter

  • Seyezhai, R.;Umarani, D.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.688-698
    • /
    • 2018
  • Quasi Z-Source Multilevel Inverter (QZMLI) topology has attracted grid connected Photovoltaic (PV) systems in recent days. So there is a remarkable research thrust in switching techniques and control strategies of QZMLI. This paper presents the mathematical analysis of Phase shift- Pulse Width Amplitude Modulation (PS-PWAM) for QZMLI and emphasizes on the advantages of the technique. The proposed technique uses the maximum and minimum envelopes of the reference waves for generation of pulses and proportion of it to generate shoot-through pulses. Hence, it results in maximum utilization of input voltage, lesser switching loss, reduced Total Harmonic Distortion (THD) of the output voltage, reduced inductor current ripple and capacitor voltage ripple. Due to these qualities, the QZMLI with PS-PWAM emerges to be the best suitable for PV based grid connected applications compared to Phase shift-Pulse Width Modulation (PS-PWM). The detailed math analysis of the proposed technique has been disclosed. Simulation has been performed for the proposed technique using MATLAB/Simulink. A prototype has been built to validate the results for which the pulses were generated using FPGA /SPARTAN 3E.

Economic analysis of biomass torrefaction plants integrated with corn ethanol plants and coal-fired power plants

  • Tiffany, Douglas G.;Lee, Won Fy;Morey, Vance;Kaliyan, Nalladurai
    • Advances in Energy Research
    • /
    • 제1권2호
    • /
    • pp.127-146
    • /
    • 2013
  • Torrefaction technologies convert assorted biomass feedstocks into energy-concentrated, carbon neutral fuel that is economically transported and easily ground for blending with fossil coals at numerous power plants around the world without needs to retrofit. Utilization of torrefied biomass in conventional electric generating units may be an increasingly attractive alternative for electricity generation as aging power plants in the world need to be upgraded or improved. This paper examines the economic feasibility of torrefaction in different scenarios by modeling torrefaction plants producing 136,078 t/year (150,000 ton/year) biocoal from wood and corn stover. The utilization of biocoal blends in existing coal-fired power plants is modeled to determine the demand for this fuel in the context of emerging policies regulating emissions from coal in the U.S. setting. Opportunities to co-locate torrefaction facilities adjacent to corn ethanol plants and coal-fired power plants are explored as means to improve economics for collaborating businesses. Life cycle analysis was conducted in parallel to this economic study and was used to determine environmental impacts of converting biomass to biocoal for blending in coal-fired power plants as well as the use of substantial flows of off-gasses produced in the torrefaction process. Sensitivity analysis of the financial rates of return of the different businesses has been performed to measure impacts of different factors, whether input prices, output prices, or policy measures that render costs or rewards for the businesses.

통계적 에너지 분석법의 FRF를 이용한 충격 응답 스텍트럼(SRS)의 결정 (Determination of Shock Response Spectrum Using FRF of Statistical Energy Analysis Method)

  • 구성완;황철규;김인성
    • 한국소음진동공학회논문집
    • /
    • 제14권7호
    • /
    • pp.551-560
    • /
    • 2004
  • A method how to determine the shock response spectrum from the FRF of the statistical energy analysis( SEA ) is presented here. The system of 3 different Plates connected by bolt joints is selected simulating missile structural sections Joined together. First, the SEA model was rendered by SEA parameters which were determined from experimental SEA method. Then, the mobility power was input to the SEA model and we can verify the validity of the model in the medium to high frequency range checking the reproduction of output average velocity. And, the shock induced shock response spectrum(SRS) was obtained using SEA FRF and arbitrarily chosen experimental FRF. We have compared the thus obtained SRS with actually measured SRS and they were relatively in good agreement. In this paper, we used the measured SEA FRF and therefore we have got the SRS well agreed with actually measured SHS even in the low frequency range. If the SEA FRF of well verified SEA model is used, the good result will come out in SEA effective frequency range which is more important at SRS.