• 제목/요약/키워드: Energy generation

검색결과 5,017건 처리시간 0.034초

Development of Life Test Equipment with Real Time Monitoring System for Butterfly Valves

  • Lee, Gi-Chun;Choi, Byung-Oh;Lee, Young-Bum;Park, Jong-Won;Nam, Tae-Yeon;Song, Keun-Won
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권1호
    • /
    • pp.40-46
    • /
    • 2017
  • Small valves including ball valves, gate valves and butterfly valves have been adopted in the fields of steam power generation, petrochemical industry, carriers, and oil tankers. Butterfly valves have normally been applied to fields where in narrow places installing the existing valves such as gate valves and ball valves have proven difficult due to the surrounding area and the heavier of these valves. Butterfly valves are used to control the mass flow of the piping system under low pressure by rotating the circular disk installed inside. The butterfly valve is benefitted by having simpler structure in which the flow is controlled by rotating the disc circular plate along the center axis, whereas the weight of the valve is light compared to the gate valve and ball valve above-mentioned, as there is no additional bracket supporting the valve body. The manufacturing company needs to acquire the performance and life test equipment, in the case of adopting the improving factors to detect leakage and damage on the seat of the valve disc. However, small companies, which are manufacturing the industrial valves, normally sell their products without the life test, which is the reliability test and environment test, because of financial and manpower problems. Furthermore, the failure mode analysis of the products failed in the field is likewise problematic as there is no system collecting the failure data on sites for analyzing the failures of valves. The analyzing and researching process is not arranged systematically because of the financial problem. Therefore this study firstly tried to obtain information about the failure data from the sites, analyzed the failure mode based on the field data collected from the customers, and then obtained field data using measuring equipment. Secondly, we designed and manufactured the performance and life test equipment which also have the real time monitoring system with the naked eye for the butterfly valves. The concept of this equipment can also be adopted by other valves, such as the ball valve, gate valve, and various others. It can be applied to variously sized valves, ranging from 25 mm to large sized valves exceeding 3000 mm. Finally, this study carries out the life test with square wave pressure, using performance and life test equipment. The performance found out that the failures from the real time monitoring system were good. The results of this study can be expanded to the other valves like ball valves, gate valves, and control valves to find out the failure mode using the real time monitoring system for durability and performance tests.

흐름과 파에 의한 해저지반내 간극수압의 발생과 액상화에 관한 해석적인 연구 (An Analytical Study on Generation of Pore-Water Pressures Induced by Flow and Waves in Seabed, and Resulting Liquefaction)

  • 이광호;김동욱;김도삼;배기성;전종혁
    • 한국해안·해양공학회논문집
    • /
    • 제27권5호
    • /
    • pp.324-338
    • /
    • 2015
  • 진행파 혹은 임의 반사율을 갖는 부분중복파 혹은 완전중복파-흐름-해저지반의 상호작용에 관한 해석해가 Lee et al.(2014; 2015a; 2015b; 2015c; 2015d) 및 Yamamoto et al.(1978)과 같은 다수의 연구자들에 의해 유도되었으며, 그들은 진동간극수압과 잔류간극수압을 별개로 취급하여 각 파동에 의한 지반응답을 논의하였다. 그러나, 실제 현장이나 실험에서 해저지반내 간극수압은 진동성분과 잔류성분이 별개로 나타나는 것이 아니고 그의 합 (전간극수압)으로 주어지기 때문에 전간극수압의 관점에서 반드시 검토될 필요가 있다. 따라서, 본 연구에서는 진동간극수압과 잔류간극수압뿐만 아니라 전간극수압의 측면에서 파동조건, 지반조건 및 흐름조건의 변화에 따른 지반응답의 변동특성을 논의하였으며, 더불어 이에 따른 액상화의 연직깊이에서 특성변화를 검토하였다. 이로부터 진행파와 순방향의 흐름의 공존장에서는 흐름속도가 증가할수록 무차원진동간극수압이 증가하고, 무차원잔류간극수압은 감소하여 결과적으로 무차원전간극수압이 작아지며, 무차원액상화 깊이도 감소하는 등의 지반응답특성을 확인할 수 있었다.

PSCAD/EMTDC를 이용한 풍력발전의 배전계통 사고특성에 관한 연구 (A Study on Fault Characteristics of DFIG in Distribution Systems Based on the PSCAD/EMTDC)

  • 손준호;김병기;전진택;노대석
    • 한국융합학회논문지
    • /
    • 제2권2호
    • /
    • pp.47-56
    • /
    • 2011
  • 2008년도 지식경제부의 전망에 의하면 신재생에너지전원 중 풍력발전의 보급전망은 2020년 37%, 2030년 42%에 달하고, 2012년부터 시행 예정인 신재생에너지 의무할당제(Renewable Portfolio Standard-RPS)의 도입으로 태양광 및 풍력 등의 신재생에너지가 향후 지속적으로 배전계통에 연계 운용될 것으로 예상된다. 현재 풍력은 배전계통에 전용선로로 연계되어 계통에 미치는 영향은 미미하지만, 3[MW] 이상의 대규모 풍력발전이 일반 배전선로로 확대 운용되면, 풍력발전 연계용 변압기 및 풍력발전기의 %임피던스에 의한 사고전류 변동으로 보호계전기(OCR, OCGR)의 오 부동작을 야기할 수 있다. 따라서 본 논문에서는 대표적인 풍력발전기인 이중여자유도발전기(Double-Fed Induction Generator-DFIG)가 고압 배전선로에 연계되어 운전되는 경우, 3상단락, 2선단락 및 1선지락의 사고특성을 분석하기 위하여, 전력계통 상용소프트웨어인 PSCAD/EMTDC를 이용하여 풍력발전기의 모델링과 시뮬레이션을 수행하고, 대칭좌표법을 통한 이론적인 수치해석의 결과치를 비교/분석하여, 제안한 수법의 유용성을 확인하였다.

Amorphous Indium-Tin-Zinc-Oxide (ITZO) Thin Film Transistors

  • 조광민;이기창;성상윤;김세윤;김정주;이준형;허영우
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.170-170
    • /
    • 2010
  • Thin-film transistors (TFT) have become the key components of electronic and optoelectronic devices. Most conventional thin-film field-effect transistors in display applications use an amorphous or polycrystal Si:H layer as the channel. This silicon layers are opaque in the visible range and severely restrict the amount of light detected by the observer due to its bandgap energy smaller than the visible light. Therefore, Si:H TFT devices reduce the efficiency of light transmittance and brightness. One method to increase the efficiency is to use the transparent oxides for the channel, electrode, and gate insulator. The development of transparent oxides for the components of thin-film field-effect transistors and the room-temperature fabrication with low voltage operations of the devices can offer the flexibility in designing the devices and contribute to the progress of next generation display technologies based on transparent displays and flexible displays. In this thesis, I report on the dc performance of transparent thin-film transistors using amorphous indium tin zinc oxides for an active layer. $SiO_2$ was employed as the gate dielectric oxide. The amorphous indium tin zinc oxides were deposited by RF magnetron sputtering. The carrier concentration of amorphous indium tin zinc oxides was controlled by oxygen pressure in the sputtering ambient. Devices are realized that display a threshold voltage of 4.17V and an on/off ration of ${\sim}10^9$ operated as an n-type enhancement mode with saturation mobility with $15.8\;cm^2/Vs$. In conclusion, the fabrication and characterization of thin-film transistors using amorphous indium tin zinc oxides for an active layer were reported. The devices were fabricated at room temperature by RF magnetron sputtering. The operation of the devices was an n-type enhancement mode with good saturation characteristics.

  • PDF

가정용 연료전지시스템 계통연계형 전력변환장치의 외부사고 성능평가에 관한 연구 (A Study on the External Fault Performance Evaluation of Grid-Connected Power Conditioning System for Residential Fuel Cell System)

  • 이정운;서원석;김영규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.131-131
    • /
    • 2009
  • 최근 환경규제가 강화되면서 친환경적인 전력생산 요구 등의 외부환경 변화에 따른 우리나라의 전력구조가 기존의 중압 집중형 발전을 탈피한 분산전원 발전에 대한 관심이 증대되고 있는 실정이다. 특히, 분산전원으로서의 전력생산은 공급의 안전성, 경쟁력 및 에너지의 지속성 등이 요구되어지는데, 재생에너지가 가지고 있는 에너지 지속성의 한계 및 설치의 제약성을 탈피할 수 있는 시스템으로 현재 연료전지시스템이 가장 근접해 있는 실정이다. 즉, 도시가스 인프라가 우수하고 인구조밀 지역이 많은 우리나라의 특성상 각 가정 및 건물에 쉽게 설치하고 공급의 안전성을 갖는 건물용 연료전지는 최근 가장 각광받고 있는 분산전원 시스템 중의 하나이다. 올해부터 모니터링사업의 일환으로 수용가에 설치 될 연료전지 시스템이 얼마나 안정적으로 전기와 열을 각 가정에 공급하고 시스템의 안전성을 확보하는 가는 건물용 연료전지의 분산전원으로서의 가능성 및 국민의 수용성을 증대시키는 중요한 역할을 할 것이다. 연료전지시스템은 상용전력과 연계되어 있기 때문에 시스템의 안정성 뿐만 아니라 상용전력의 변화에 대응하여 안정적인 운전을 하는지에 대한 평가가 필수적이다. 이에 따라 본 연구에서는 가정용 연료전지시스템의 성능 및 안전성평가의 일환으로 계통연계형 전력변환장치의 성능 및 안전성을 평가 하고자 한다. 연료전지 검사를 위한 계통연계형 전력변환장치의 시험평가 항목으로는 크게 정상특성성능시험, 보호기능성능시험, 과도응답특성성능시험 및 외부사고성능시험 등으로 나뉘어진다. 본 연구에서는 외부사고 성능시험 항목들인 출력측 단락시험, 계통전압 순간정전?순간강하시험 및 부하차단 시험 등을 통하여 외부사고에 대한 성능 및 안전성을 평가하였다. 외부사고 성능시험의 주 목적은 시스템의 이상 운전이 아니라 외부의 영향에 따른 시스템의 안전성 및 전력품질을 평가한다. 출력측 단락시험을 수행하기 위해서 전력변환장치를 정격 출력 전압, 정격 출력 주파수 및 정격 출력에서 운전한 후, 교류 전원장치는 단락 전류를 검출하여, 사고 발생 후 0.3초 이내에 개방하도록 설정하였다. 여기서, 단락 저항 Rsc를 정격 전류의 10배 이상에 해당하는 부하와 같은 값으로 설정하였다. 스위치 SWSC를 폐로하여 단락 상태를 만들며, 이 때 전력변환장치의 출력전류와 차단 또는 정지 시간을 측정하였다. 실험 결과에 대한 판정기준은 단락전류를 검출하여 0.5초 이내에 개폐기 개방 또는 게이트 블록 기능이 동작하여 시스템을 안정하게 정지시키고 시스템 어떤 부위에도 손상이 없어야 한다. 실험 결과 파워컨디셔너의 출력전류 및 차단 또는 정지된시간이 40ms로 나타났고, 출력전류의 파형도 매우 안정함을 볼 수 있었다. 이와 같이 모든 실험을 수행한 결과 외부사고에 대하여 시스템이 안전하게 정지하는 등 연료전지 시스템의 안전성을 확인하였다.

  • PDF

수중 아-크 방전음원에 관한 연구 (ARC Discharge Sound Source in Underwater)

  • 장재환;장지원
    • 수산해양기술연구
    • /
    • 제21권1호
    • /
    • pp.12-18
    • /
    • 1985
  • 고압변압기의 1차측을 제어하고 2차측에 유도된 전압을 이용한 수중방전음원의 전기음향학적 제특성을 분석.검사한 결과는 다음과 같다. 1. 방전시 2차측 전류는 초기에는 Ohm 법칙을 따르다가 전류가 최고 6.3A 흘러 절연 파괴되었으며, 그 순간 방전음이 생성되었다. 2. 전류인가점과 방전음 생성문의 시간차는 약 3ms였으며, 전압이 최고일 때 절연파괴가 일어나 방전음이 생성되었다. 3. 전극의 끝이 뾰족할수록 2차측 전압이 높을수록 음압수준은 높았다. 4. 뾰족한 형태의 전극은 전극간격이 100cm일 때도 방전이 일어났으며 전극간격이 1cm이상부터 비교적 안정된 방전음이 생성되었다. 5. 방전음의 펄스폭은 약 0.15ms인 Shock Wave였으며, 10HKz 이하의 합성저주파 성분이었다.

  • PDF

국내발전소 소방안전관리 운영실태조사 및 개선방안에 관한 연구 (A Study of the Improvement Plan and Real Condition Estimation of Fire Protection Safety Management for Power Plants in Korea)

  • 강길수;최재욱
    • 한국화재소방학회논문지
    • /
    • 제31권2호
    • /
    • pp.61-73
    • /
    • 2017
  • 2011년 후쿠시마 원전참사나 2001년 캘리포니아 정전사태 등은 전력관련 대형재난사고로 국가적인 막대한 손실을 가져온 발전소 안전관리의 중요성을 재조명하는 사례로 손꼽고 있다. 인간이 지구상에 살고 있는 한 전기가 없이 살 수 없는 상황에서 원자력, 석탄 및 가스 등 대용량의 위험물질을 연료로 전기를 생산하는 발전소가 안전관리의 소홀로 인한 화재폭발사고나 방사능누출, 최근 이슈가 되고 있는 지진 등 자연재해로부터 국민의 생명과 재산손실예방 및 안정적 경제성장을 위해서도 체계적인 소방안전관리의 강화노력은 절대적으로 필요하다. 따라서 본 연구에서는 국내 전력공급을 책임지고 있는 한국남부발전 등 5개 발전사 및 한수원의 소방안전관계자를 대상으로 발전소 소방안전관리 운영실태를 조사하여 분석을 수행하였으며, 그 결과, 체계적인 발전소 소방안전관리를 위해서는 소방안전경영시스템의 구축을 바탕으로 소방담당자를 위한 실효적인 업무매뉴얼 및 관리시스템의 개발과 소방안전교육의 내실화 및 지진에 대비한 내진설계의 강화를 개선방안으로 도출하였다.

고원변형과 열간노출에 따른 주조용 합금 738LC의 탄화물 분해거동 고찰 (Effects of High Temperature Deformation and Thermal Exposure on Carbide Reaction Cast Alloy 738LC)

  • 주동원;조창용;김두현;서성문;이영찬
    • 한국재료학회지
    • /
    • 제10권2호
    • /
    • pp.111-116
    • /
    • 2000
  • 니켈기 주조용 합금 738LC를 816$^{\circ}C$와 982$^{\circ}C$에서 크리프 파단 시험과 열간 노출시험을 통해 온도와 응력 변화에 따른 파단양상, 탄화물과 $\sigma$상의 석출 거동에 대해 조사하였다. 816$^{\circ}C$/440MPa에서는 크리프 파단양상이 전단변형에 의한 입내파괴를 나타내었으나, 982$^{\circ}C$/152MPa에서는 표면과 접하는 결정입계에서 입계산화에 의해 표면에너지의 감소로 균열이 나타나 진행되는 입계파괴가 나타났다. M(sub)23C(sub)6 탄화물이 816$^{\circ}C$에서는 주로 결정입계에서와 전단변형에 의한 입내균열을 따라 석출하였으나, 982$^{\circ}C$에서는 결정입계 뿐만 아니라 입내에서는 석출하였으며 석출양은 증가하였다. $\sigma$상은 Cr(sub)23C(sub)6 탄화물에서 핵생성 후 기지로 성장하며, 온도가 높고 응력이 주어지면 Cr(sub)23C(sub)6 탄화물의 양이 증가하여 $\sigma$상의 석출도 많아졌다.

  • PDF

CO2 배출량을 감안한 화력발전소의 생산성 변화 분석: Luenberger지수 접근법 (CO2 Emission and Productivity of Fossil-fueled Power Plants: A Luenberger Indicator Approach)

  • 권오상
    • 자원ㆍ환경경제연구
    • /
    • 제19권4호
    • /
    • pp.733-752
    • /
    • 2010
  • 본고는 한국의 화력발전소의 생산성 변화율 자체와 그 변화행태와 발전유형별 분포, 그리고 생산성 변화의 구성요소 등을 $CO_2$ 배출량을 감안하여 분석하며, 그러한 분석목적을 달성하는 데 매우 유용한 Luenberger지수를 비모수적 기법을 이용해 도출하는 방식으로 연구를 진행한다. 분석결과 $CO_2$ 배출량을 감안하지 않을 때에는 생산성 변화율이 상당한 정도 왜곡된 형태로 나타날 수 있음이 확인되었다. 특히 발전소의 경우 가동률 차이가 생산성 지표에 큰 영향을 미치게 되는데, $CO_2$ 배출량을 감안하지 않으면 주로 가동률 차이에 의한 생산량 변화가 생산성 변화율에 영향을 미치게 되고, 그 결과 생산성 변화율 계측치가 비상식적으로 높거나 낮게 되는 현상이 발견되었다. 아울러 분석기간 동안 $CO_2$의 배출량이 늘어났기 때문에 이를 반영하지 않고 생산성 증가율을 계측하면 생산성 증가율을 과대평가하게 됨도 밝혀졌다. $CO_2$를 모형에 포함하느냐의 여부는 또한 발전소 유형별로 생산성 증가율이 어떻게 다른지, 그리고 생산성 변화가 발생한 주요인은 무엇인지를 설명함에 있어서도 상당한 차이를 초래하였기 때문에 이들 내용을 확인하기 위해서도 적절한 방식으로 $CO_2$ 배출량을 반영해 주는 것이 중요하다.

  • PDF

우(牛)심근조직의 mitochondria에서 cytochrome-c-oxidase의 형성과 변화 (The Formation and Change of Cytochrome-c-oxidase in the Mitochondria of the Bovine Cardiac Muscle)

  • 김수진
    • Applied Microscopy
    • /
    • 제38권2호
    • /
    • pp.125-133
    • /
    • 2008
  • Mitochondria 내막의 cytochrome-c-oxidase는 세포의 에너지 생합성에 중요한 요소이며, 세포자멸사와 각종세포의 병리학적 현상과 밀접한 연관성이 있는 전자전달계효소로 알려져 있다. Porin 단백은 mitochondria 내막과 외막에 분포하는 효소단백으로 전자전달계효소 형성과 ATP 운반에 관여하는 것으로 알려져 있다. 따라서 면역현미경법을 사용하여 cytochrome-c-oxidase의 분포와 porin 단백과의 연관성을 확인하여 mitochondria의 cristae에 분포하는 cytochrome-c-oxidase의 형성과 변화를 알아보고자 하였다. Cardiac muscle tissue의 sarcoplasm에는 많은 수의 mitochondria가 분포하며, cytochrome-c-oxidase가 풍부한 mitochondria와 porin 단백이 풍부한 mitochondria로 구별되었다. Cytochrome-c-oxidase가 풍부한 mitochondria는 porin 단백이 빈약하고 porin 단백이 풍부한 mitochondria는 cytochrome-c-oxidase가 소량 포함되어 있는 것으로 관찰되었다. 심근조직의 부위에 따라 근형질에 분포하는 mitochondria에 cytochrome-c-oxidase가 풍부한 mitochondria와 porin 단백이 풍부한 mitochondria가 각각 상이하게 분포하였다. 이상의 결과로 미성숙 mitochondria는 많은 양의 porin 단백을 함유하여 근형질로부터 단백질 소단위를 mitochondria 막내로 운반하여 cytochrome-c-oxidase를 형성시키고 mitochondria가 성숙하면서 ATP를 운반할 최소한 양의 porin 단백만을 남기고 소멸되는 것으로 추측된다.