• 제목/요약/키워드: Energy circulating operation

검색결과 53건 처리시간 0.028초

터널 라이닝 내부에 설치한 열교환기의 현장모니터링 연구 (Study on long-term monitoring of heat exchanger installed in the tunnel lining)

  • 이철호;박문서;최항석;손병후;정재형
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.195.1-195.1
    • /
    • 2011
  • This paper presents an experimental study on a new potential geothermal energy source obtained from tunnel structures. An "energy textile", which is a textile-type ground heat exchanger, was fabricated between a shotcrete layer and a guided drainage geotextile in the tunnel lining system. To examine the long-term thermal behavior of the energy textile, the difference in temperatures of the inlet and outlet fluid circulating through the heat exchange pipe within the energy textile was monitored using a constant-temperature water bath. Daily heat exchange rate of the energy textile during cooling operation was estimated from the measured temperatures of the inlet and outlet fluid through the energy textile. The air and ground temperature was also continuously monitored. The operation of the energy textile as a ground heat exchanger was simulated using a 3D numerical CFD model (Fluent). The thermal conductivity of shotcrete and concrete lining components and temperature variation of air in the tunnel were incorporated in the model. The numerical analysis shows a good agreement with the long-term monitoring result.

  • PDF

The Analysis of Life Cycle Cost and Cooling Water Circulating Pump Energy Saving According to Variable Speed Pressure Differential Setpoint Control Strategy

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jang, Cheol-Yong;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose : The study applied control strategy to reduce through optimal control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. The study has the purpose to review validity of control on variable speed as ESMs(Energy Saving Measures) and establish the control technology on variable speed pump. The study performed reduction analysis of building energy and economic evaluation of pump through energy effectiveness control strategy of HVAC system. Method: The study sought possible reduction through energy control strategy which can provide proper flow fitting to building load by applying control on variable speed pump. The study applied control strategy to reduce through pressure differential set-point control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. Result : The results showed that about 16-35% of pump energy could be saved by using these optimal control strategies. In the result of analysis on 10 years life cycle cost of analysis on payback period of initial investment pump, variable speed pump control showed 5.1 years.

에틸렌글리콜법을 활용한 국내 순환유동층보일러 석탄회의 Free CaO 평가 연구 (Study on the Free CaO Analysis of Coal Ash in the Domestic Circulating Fluidized Bed Combustion using ethylene glycol method)

  • 서준형;백철승;김영진;최문관;조계홍;안지환
    • 에너지공학
    • /
    • 제26권1호
    • /
    • pp.1-8
    • /
    • 2017
  • 에틸렌글리콜법을 활용하여 국내 순환유동층보일러형 발전소에서 발생되는 석탄회의 물리화학적 특성 및 Free CaO 평가를 수행하였다. 물리화학적 특성결과, 각 발전사마다 많은 CaO 함량 차이를 나타내었는데, 이는 황산화물 배출농도 규제 차이 및 보일러 제작사가 다른 발전소의 운전특성이 복합적으로 반영된 것으로 판단된다. Free CaO의 함량은, 비산재는 1.96 ~ 10.78 %, 바닥재는 0.07 ~ 4.24%로 비산재가 바닥재보다 높게 나타났으며, 원시료의 CaO 함량 이외에 입도 분포에 따라서도 크게 변화되는 것으로 확인되었다.

폐기물 고형연료(RDF)의 순환유동층 연소 및 증기생산 (Circulting Fluidized Bed Combustion of Refuse Derived Fuel and Steam Production)

  • 선도원;배달희;조성호;이승용
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.613-616
    • /
    • 2007
  • A pilot scale circulating fluidized bed for refuse derived fuel is developed and constructed in order to demonstrate efficient and safe utilization of waste fuel. The capacity of the facility is 8 steam tons per hour with the steam quality of $450^{\circ}C$ and 38atm. The quantity and the quality of the produced steam is sufficient to produce 1MWe power capacity. The test operation proved the high combustion efficiency of 99% and up. The emissions of NOx, SOx in flue gas are below 100, 60ppm respectively with out any emission control. HCl emissions were above 400ppm at the combustor exit but reduced below 10ppm after scrubber.

  • PDF

하이브리드 지중열교환기 적용 지열 히트펌프 시스템의 난방 성능 분석 (Heating Performance Analysis of Ground-Source Heat Pump (GSHP) System using Hybrid Ground Heat Exchanger (HGHE))

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권3호
    • /
    • pp.8-16
    • /
    • 2020
  • This paper presents the heating performance analysis results of a ground-source heat pump (GSHP) system using hybrid ground heat exchanger (HGHE). In this paper, the HGHE refers to the ground heat exchanger (GHE) using both a surface water heat exchanger (SWHE) and a vertical GHE. In order to evaluate the system performance, we installed monitoring sensors for measuring temperatures and power consumption, and then measured operation data with 4 different load burdened ratios of the HGHE. During the entire measurement period, the average heating capacity of the heat pump was 37.3 kW. In addition, the compressor of the heat pump consumed 9.4 kW of power, while the circulating pump of the HGHE used 6.7 kW of power. Therefore, the average heating coefficient of performance (COP) for the heat pump unit was 4.0, while the system including the circulating pump was 2.7. Finally, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further researches are needed to optimize the design data for various load ratios of the HGHE.

능동위상제어기를 이용한 배전선로 자율 재구성 시 순환전류 감소 기법 (Circulating Current Reduction Method during Distribution Network Dynamic Reconfiguration using Active Phase Controller)

  • 김수연;정다움;박성준;김동희
    • 전력전자학회논문지
    • /
    • 제25권1호
    • /
    • pp.6-12
    • /
    • 2020
  • In recent years, the demand for the distribution of energy resource has been increasing. However, the output power is limited by the stability of the distribution network. This study proposes an active distribution network that can reconfigure the distribution line using an active phase controller. The conventional distribution network has a fixed structure, whereas the proposed active distribution network has a variable structure. Therefore, the active distribution network can increase the output power of the distribution energy resource and reduce the overload of distribution line facilities. The active phase controller has two operation modes to minimize the circulating current during dynamic reconfiguration. In this study, the voltage and current control algorithms are proposed for the active phase controller. The proposed method for the active phase controller is simulated via PSIM simulation.

3MWth급 순환유동층 바이오매스 가스화기의 운전에서 Equivalence ratio 영향 (Effect of equivalence ratio on operation of 3MWth circulating fluidized bed for biomass gasification)

  • 박성범;이정우;송재헌;박대원
    • 한국응용과학기술학회지
    • /
    • 제34권1호
    • /
    • pp.58-65
    • /
    • 2017
  • 유동층가스화기는 경제적으로 기술적으로 입증된 기술로서 가장 상용화에 가까운 가능성을 보여주고 있다. 그러나 한국에서는 설계, 현장문제 해결뿐 아니라 파일럿 규모의 설비 운전 등이 부족하여 상용화에 이르지 못하고 있다. 본 연구에서는 바이오매스의 가스화를 위하여 3 MWth 급 순환유동층(CFB) 반응기를 개발하여 운전하였다. 유동층반응기는 순환유동층 반응기와 기포유동층 반응기로 구성되었으며 타르와 산성가스를 제거하기 위하여 세라믹필터, 급속냉각, 습식스크러버를 사용하였다. 3MWth 급 바이오매스 가스화기의 최적 운전조건을 도출하기 위하여 equivalence ratio에 따른 영향을 조사하였다

순환유동층 보일러 로내 탈황을 위한 석회석 평가 (Evaluation of Limestone for In-Situ Desulfurization in CFB Boilers)

  • 이시훈;김동원;이종민;배용채
    • Korean Chemical Engineering Research
    • /
    • 제57권6호
    • /
    • pp.853-860
    • /
    • 2019
  • 나날이 엄격해지는 환경 규제를 만족시키기 위하여, 고체 입자를 유체처럼 이용하는 순산소 순환유동층 및 초초임계 순환유동층 발전 기술이 전세계에서 개발되고 있다. 순환유동층 발전 공정들에서 미세먼지, 산성비의 주범으로 알려진 황산화물을 저감하는 전통적인 방법은 황산화물과 반응하는 석회석을 보일러 내에 직접 주입하는 것이다. 그러나 보일러 내에 주입된 석회석은 다양한 조업 변수들(온도, 압력, 고체 순환속도, 층밀도, 체류시간 등)의 영향을 받아 탈황 성능이 지속적으로 변화하게 된다. 이에 본 연구에서는 기존에 발표된 탈황 반응 속도식과 순환유동층의 수력학적 특성식들을 결합하여 순환유동층 보일러에서 석회석과 순환유동층 운전 특성들만으로 탈황 효율을 예측하는 식을 개발하였다. 특히 다양한 국내 석회석들의 탈황 반응들로부터 얻어진 실험 결과들을 이용하여 탈황 효율 예측식을 개선하였다.

에너지 파일의 열적거동 인자분석 (Thermal Influential Factors of Energy Pile)

  • 정상섬;송진영;민혜선;이성준
    • 대한토목학회논문집
    • /
    • 제30권6C호
    • /
    • pp.231-239
    • /
    • 2010
  • 본 논문에서는 지열을 이용한 PHC, 강관, 동관말뚝 형태인 에너지 파일의 지반 조건별 내부 충진재 열전도도 효율과 겨울철 열교환기 내부 순환수의 유속별(0.3m/s, 0.6m/s, 0.9m/s) 24시간 운용(8시간 운용, 16시간 대기)시너지 파일의 열전달 거동을 ABAQUS(ver 6.10)와 FLUENT(ver 6.3.26)를 사용하여 분석하였다. 분석결과 말뚝 재료와 지반조건별 열전달 효율은 동관, 강관, PHC 말뚝순으로 열전달 효율이 좋은 것으로 나타났으며, 말뚝 중 PHC 말뚝 형태의 에너지 파일을 유속별 8시간 운용에 따른 분석결과 경계조건이 일정할 때 유속 조건 중 유입속도 0.6m/s 일 때 평균 유출온도(275.4K) 및 열교환율(103.1W/m)로 경제적인 유속으로 판단되었으며, 8시간 운용 후 초기조건과 동일하게 16시간동안 지열이 에너지파일에 공급 시 정상상태와의 온도차는 0.1K 로 열량이 충분히 충전되어 에너지 파일의 겨울철 8시간운용 - 6시간대기는 운용상 적절한 것으로 판단된다.

열량기준 50kW급 매체순환식 가스연소기의 개념설계 및 변수해석 (Conceptual Design of 50 kW thermal Chemical-Looping Combustor and Analysis of Variables)

  • 류호정;진경태
    • 에너지공학
    • /
    • 제12권4호
    • /
    • pp.289-301
    • /
    • 2003
  • 매체순환식 가스연소기의 개발을 위해 산화반응기와 환원반응기가 연계된 2탑 가압순환유동층 조건의 50kWth 매체순환식 가스연소기에 대해 물질수지와 에너지수지를 통한 개념설계를 수행하였다. 매체순환식 가스연소기의 물질수지를 통해 산화반응기는 상승관 형태의 고속유동층 조건으로, 환원반응기는 기포유동층 조건으로 반응기 형태를 결정하였다. 물질수지와 에너지수지에 의해 계산된 층내 고체량, 고체순환량 및 반응기 크기는 장치제작 및 실제조업에 적당한 범위의 값을 나타내었으며 산소공여입자의 반응속도는 만족할 만한 수준에 도달하는 것으로 확인되었다. 본 연구의 개념설계 결과에 의하면 매체순환식 가스연소기의 조업조건은 상용 순환유동층의 조업조건과 유사하였으며 실제공정에 적용하기에 무리가 없는 것으로 사료되었다. 본 연구에서 개발된 설계 tool을 이용하여 시스템의 용량, 조업압력, 산소공여입자 중의금속산화물의 함량, 수증기 주입량, 기체유속 및 고체층 높이 등의 변화에 따른 설계 값의 변화를 해석하였으며 이를 통해 조업조건 변화에 따른 시스템의 성능변화를 예측할 수 있었다.