• 제목/요약/키워드: Energy Saving Strategy

검색결과 97건 처리시간 0.034초

에너지소비 절감을 위한 열차최적운전 (Optimal Train Driving Strategy for Energy Saving)

  • 손창훈;서병설
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.888-894
    • /
    • 2011
  • This paper is a study of optimal train driving strategy to minimize the energy consumption. Optimal driving strategy can be analyzed as an optimal problem which have constraints by using Largrangian Function and Kuhn-Tucker condition. We simulate the section between Konkuk University Station and Seongsu Station which is on outer circle line of the Seoul Metro line No.2 by using MATLAB and consider the straight level track and the speed limit.

  • PDF

PSO를 이용한 물 재이용 펌프시스템의 에너지 비용 제어 (Energy Cost Saving Control of Water Reuse Pumping System Using Particle Swarm Optimization)

  • 부창진;김호찬;강민제
    • 한국산학기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.860-867
    • /
    • 2015
  • 본 논문은 PSO 알고리즘을 이용하여 물 재이용 펌프 시스템의 에너지비용을 최소화 할 수 있는 방법을 제안한다. 1시간 단위의 시간대에서 펌프제어를 위해 계시별 요금제를 기반으로 하여 최적화 구간을 설정하고 PSO알고리즘을 이용하여 에너지 비용을 절감할 수 있도록 펌프동작을 제어한다. 물 재이용 펌프시스템에서 고정된 유량을 출력하는 펌프와 입력전력을 가변할 수 있는 펌프에 대해 TOU 기반에서 에너지 비용을 최대로 줄일 수 있도록 시스템을 동작시킨다. 시뮬레이션을 통해 제안한 에너지 비용 절감 방법이 기존 수위기반의 제어방법보다 비용을 절감할 수 있음을 확인할 수 있다.

실내수영장의 에너지 소비요소별 에너지 절약효과에 관한 연구 (A Study on the Energy Conservation Effect of Each Energy Consumption Component In Indoor Swimming Pools)

  • 김영돈;권규동;여명석;김광우
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1092-1101
    • /
    • 2002
  • The objective of this study is to develop energy saving strategies for indoor swimming pools and to estimate the effect of each energy saving strategy. For this purpose, field measurements regarding pool water heating energy, domestic hot water heating energy are conducted and a base energy consumption model is implemented using the DOE-2.1E program. The results of the study reveal that 25% of the total pool water heating energy may be saved by using night time pool covers, 27% of the total domestic hot water heating energy may be saved by using a waste water heat recovery system (effic. 60%), and of the total ventilation energy may be saved using an exhaust air heat recovery system (effic. 60%).

Utility AC Frequency to High Frequency ACPower Conversion Circuit with Soft Switching PWM Strategy

  • Sugimura Hisayuki;Ahmed Nabil A.;Ahmed Tarek;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권2호
    • /
    • pp.181-188
    • /
    • 2005
  • In this paper, a DC smoothing filterless soft switching pulse modulated high frequency AC power conversion circuit connected to utility. frequency AC power source is proposed for consumer induction heating hot water producer, steamer and super heated steamer. The operating principle of DC link filterless utility frequency AC-high frequency AC (HF AC) power conversion circuit defined as high frequency cycloinverter is described, which can operate under a principle of ZVS/AVT and power regulation based on alternate asymmetrical PWM in synchronization with the utility frequency single phase AC positive or negative half wave voltage. The dual mode modulation control scheme based on high frequency PWM and commercial frequency AC voltage PDM for the proposed high frequency cycloinverter are discussed to enlarge its soft switching commutation operating range for wide HF AC power regulation. This high frequency cycloinverter is developed for high frequency IH Dual Packs Heater (DPH) type boiler used in consumer and industrial fluid pipeline systems. Based on the experiment and simulation results, this high frequency cycloinverter is proved to be suitable for the consumer use IH-DPH boiler and hot water producers. The cycloinverter power regulation and power conversion efficiency characteristics are evaluated and discussed.

에너지절감을 위한 물 재이용 펌프시스템의 최적운전 제어 (Optimal Operation Control for Energy Saving in Water Reuse Pumping System)

  • 부창진;김호찬
    • 한국산학기술학회논문지
    • /
    • 제13권5호
    • /
    • pp.2414-2419
    • /
    • 2012
  • 본 논문에서는 물 재이용 펌프 시스템의 에너지 효율적 운전 방법을 제안한다. 1시간 단위의 시간대에서 최적운전제어를 위해 예측구간 스위칭방법과 선형계획법을 적용하고 에너지 비용은 경부하, 중부하, 그리고 최대부하를 포함한 TOU 요금과 피크요금을 통해 산정하도록 한다. 물 재이용 펌프시스템에서의 최적운전은 TOU 요금과 피크요금을 포함한 에너지 비용을 최대로 줄일 수 있도록 수행한다. 시뮬레이션을 통해 제안한 최적운전방법을 적용하면 많은 전력 에너지 비용의 절감과 전력계통의 안정성 향상을 확인할 수 있다.

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • 국제초고층학회논문집
    • /
    • 제3권2호
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

해외 사례분석을 통한 Cool Roof의 도입 방안 (Introducing Strategy of Cool Roofs based on Comparative Evaluation of Foreign Cases)

  • 최진호;엄정섭
    • 환경영향평가
    • /
    • 제19권6호
    • /
    • pp.591-605
    • /
    • 2010
  • Cool roofs are currently being emerged as one of important mechanism to save energy in relation to the building. This paper reviews worldwide experiences (USA, Japan and EU etc) for the potential benefits cool roofs offer in relation to building energy saving for comparison purposes. It is confirmed that there is a significant potential to the energy saving by introducing the cool roof in a Korean climate because of similarity in terms of HDD (Heating Degree Day) and CDD (Cooling Degree Day) as those countries reviewed. Such a comparative study highlights that the type of measurements performed and the quantitative parameters reported from the countries should be standardized in Korean context in order to implement further comparable experiments for scientifically sound investigations. It is anticipated that this research output could be used as a valuable reference in implementing a Nation-wide cool roofing strategy in the central and local governments since a suitable technical, more objective direction has been proposed based on the measured, fully quantitative performance of the involved components of a cool roof system in the global context. From this critical review, a very important step has been made concerning the practicality of cool roof in Korean context. Ultimately, the suggestion in this paper will greatly contribute to opening new possibilities for introducing cool roof in this country, proposed as an initial aim of this paper.

STUDY OF INTERNAL RECYCLE DISTRIBUTION AND HEAT TRANSFER EFFECT FOR OPTIMAL DESIGN OF DIVIDING WALL DISTILLATION COLUMNS

  • Lee, Ki-Hong;Lee, Moon-Yong;Jeong, Seong-Oh
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2319-2324
    • /
    • 2003
  • This paper addresses the optimal design of dividing wall distillation column which is rapidly applied in a variety of chemical processes over recent several years because of its high energy saving efficiency. A general dividing wall column model which can cope with the heat transfer through the dividing wall is developed using rigorous computer simulation. Based on the simulation model, the effects of the internal recycle flow distribution around the dividing wall and the heat transfer across the dividing wall on overall system performance are investigated. An improved method is suggested to utilize the heat transfer through the wall to optimal column design. The suggested method is compared with the existing method via. simulation study and shows more improved energy saving result. Several control strategies for the divided wall column are tested and the optimal control strategy is propose

  • PDF

중앙 냉방시스템에 대한 외기보상제어의 절약 성능에 관한 실험적 연구 (Experimental Study on Energy Saving Performance of Outdoor Temperature Reset Control Strategy for Central Cooling System)

  • 김동철;송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.30-36
    • /
    • 2011
  • In this study, energy saving performance of outdoor temperature reset control strategy for central cooling system is researched by experiments. Outdoor temperature reset control is the control method to change indoor air set temperature according to outdoor air temperature change. The range of indoor air set temperature is represented by the comfort temperature range of indoor air temperature offered from ASHRAE and indoor air set temperature is programmed between $22^{\circ}C$ and $27^{\circ}C$ by outdoor air temperature $20^{\circ}C{\sim}32^{\circ}C$ in summer. As a result of applying outdoor temperature reset control to central cooling system, the suggested control method shows better performances of energy savings than the conventional method which indoor temperature maintains constantly.

DUAL DUTY CYCLE CONTROLLED SOFT-SWITCHING HIGH FREQUENCY INVERTER USING AUXILIARY REVERSE BLOCKING SWITCHED RESONANT CAPACITOR

  • Bishwajit, Saha;Suh, Ki-Young;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.129-131
    • /
    • 2006
  • This paper presents a new ZVS-PWM high frequency inverter. The ZVS operation is achieved in the whole load range by using a simple auxiliary reverse blocking switch in parallel with series resonant capacitor. The operating principle and the operating characteristics of the new high frequency circuit treated here are illustrated and evaluated on the basis of simulation results. It was examined that the complete soft switching operation can be achieved even for low power setting ranges by introducing the high frequency dual duty cycle control scheme. In the proposed high frequency inverter treated here, the dual mode pulse modulation control strategy of the asymmetrical PWM in the higher power setting ranges and the lower power setting ones, the output power of this high frequency inverter could introduce in order to extend soft switching operation ranges. Dual duty cycle is used to provide a wide range of output power regulation that is important in many high frequency inverter applications. It is more suitable for induction heating applications the operation and control principle of the proposed high frequency inverter are described and verified through simulated results.

  • PDF